rt 12180
TRANSCRIPT
-
7/21/2019 Rt 12180
1/2
RT 12180RT 12180 is a general purpose batte ry with 5 yearsfloating design life , meet with IEC, JIS standard .Withheavy duty grid, thickness plates , special additives, RTseries battery have long and reliable standby service life.
Specification
Cells Per Unit
Voltage Per Unit
Normal Operating Temperature Range
Capacity
Weight
Max. Discharge Current
Internal Resistance
Operating Temperature Range
6
12o
18Ah@20hr-rate to 1.75V per cell @25 C
Approx . 5.0 Kg
180 A (5 sec)
Approx . 14 m
Discharge : -20 ~60o o
Charge: 0 C~50 Co o
Storage: -20 C~60 C
o oC C
o o25 C5 C
Float charging Voltage
Recommended Maximum Charging
Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Constainer Material
Faston F3/F13
A.B.S. (UL94-HB) , F lammabil it y resistance of UL94-V2can be available upon request.
Dimensions
(12V18Ah)
o13.7 to 13.9 VDC/unit Average at 25 C
5.4 A
o14.6 to 14.8 VDC/unit Average at 25 C
Unit: mm
Al l ment ioned values are average values.
oConstant Current Discharge Characteristics : A(25 C)
oConstant Power Discharge Characteristics : W(25 C)
F.V/Time
5MIN
10MIN 15MI N 30MI N 2H R 3HR 4HR 5HR 8HR 10HR 20HR1H R
F.V/Time 10MIN 15MIN 30MIN 2HR 3HR 4HR 5HR 8HR 10HR 20HR1HR
5MIN
Dimension: 181(L) (W) 167(H)77
Teminal F3 Terminal F13
RITAR Valve Regulated Lead Acid (VRLA) batteries can be storedo
for more than 6 months at 25 C. Self-dischar ge ratio less than 3%o
per month at 25 C. Please charge batteries before using.
9.60 V 73.19 4 7.99 37 .61 21 .11 12.5 5 7.22 6 4.910 3 .929 3. 263 2.0 78 1.7 99 1.01 0
10.0 V 70.55 4 6.79 36 .41 20 .84 12.2 0 7.08 0 4.820 3 .875 3. 208 2.0 70 1.7 81 0.97 3
10.2 V 66.40 4 4.47 35 .40 20 .53 12.0 9 7.00 5 4.777 3 .837 3. 173 2.0 51 1.7 54 0.95 5
10.5 V 59.69 4 1.58 33 .39 19 .96 11.8 5 6.91 4 4.734 3 .800 3. 135 2.0 33 1.7 45 0.92 7
10.8 V 53.48 3 8.78 31 .50 19 .30 11.6 4 6.85 7 4.679 3 .781 3. 102 2.0 25 1.7 16 0.87 3
11.1 V 46.79 3 5.55 29 .06 18 .57 11.3 2 6.58 1 4.587 3 .748 3. 070 2.0 09 1.6 89 0.85 8
9.60 V 770.0 5 10.4 40 2.7 24 1.7 145 .7 84.3 0 57.40 4 6.50 38 .63 24 .89 21. 56 12.1 0
10.0 V 749.9 4 99.8 39 6.9 23 9.2 143 .5 83.5 8 57.28 4 6.39 38 .43 24 .79 21. 35 11.6 7
10.2 V 713.3 4 80.0 39 1.7 23 7.1 142 .5 83.0 5 57.07 4 6.01 38 .06 24 .60 21. 15 11.4 6
10.5 V 651.0 4 60.2 37 1.3 23 2.3 140 .6 82.3 8 56.83 4 5.59 37 .61 24 .40 20. 93 11.1 3
10.8 V 587.4 4 30.5 35 0.8 22 6.8 138 .3 81.7 0 56.17 4 5.42 37 .22 24 .29 20. 61 10.4 9
11.1 V 518.0 4 00.8 33 0.4 22 0.6 135 .7 78.8 8 55.07 4 4.96 36 .86 24 .12 20. 31 10.3 2
-
7/21/2019 Rt 12180
2/2
12V18Ah
Storage characteristic
Charge characteristic Curve for standby use
Discharge characteristic Curve
Discharge Time
0.6
min
1.2 3 6 12 30 51 2
Hr
10 20 24
1C
13
12
11
10
9
6.5
6.0
5.5
5.0
4.5
4.3
4.0
3.7
3.3
3.0
TerminalVoltage
(V)
3C
0.16C
0.62C
0.35C
0.093C0.05C
15
14
13
12
11
10
9
7.5
7.0
6.5
6.0
5.5
5.0
4.5
5.0
4.7
4.3
4.0
3.7
3.3
3.0
0.24
0.20
0.16
0.12
0.08
0.04
0
120
100
80
60
40
20
0
0 42 86 28
Charge Timeh
1210 1614 2018 24
ChargeVoltageV
Chcrge Voltage
Discharge
100%0.05CA20h
50%0.05CA10h
Charge Chcrge Voltage2.275V/C
Charge Current0.1CA
Temperature 25
Charge Current
Chcrge Volume
ChargeCurrent(CA)
ChargeVolume
(%)
Supplementary charge required(Carry out supplementary chargebefore use if 100% capacity is
requires)
Supplementary charge requiredbefore use.This supplementary charge will helpto recover the capacity and shouldbe made as early as possible.
Supplementary charge may oftenfail to recover the capacity.The battery should never be leftstanding till this state is reached
RT 12180
0.2C A1.0C
Final DischargeVoltage V/cell
DischargeCurrent (A)
A0.2C
1.60V
A1.0C
1.75V 1.70V
Discharge Current VS. Discharge Voltage
Supplementary charge and storageguidelines
-0.2Cx2h+0.1CAx12h
Constant Voltage
Fast
Charge the batteries at least once every six months,o
if they are stored at 25 C.
Charging Method:
Constant Current
-0.2Cx2h+0.3CAx4.0h
SHENZHEN RITAR POWER CO. LTD.
URL:www.ritarpower.com
10
LifeExpectancy(years)
0 10
Battery Temperature
4020 30 50
8
6
4
2
30
Storage Time (months)
20
0
Capacity
(%)
40
60
100
80
40
10
0
2 4 6 8 10 12 14 16 18 20 22 24
20
Float Se rvice:
Every month, recommend inspect ion every battery voltage.
Every three months, recommend equalization charge for one time.
Equalization charge method:
Discharge: 100% rate capacity discharge.
Charge: Max. c urrent 0.3CA, constant voltage 2.4-2.45V/Cell charge 24h.
Effect of temperature on float charge voltage: -3mV//Cell.
Length of service life will be directly affected by the number of discharge
. cyc les, depth of discharge, ambient temperature and charging voltage.
Maintenance & Cautions
Address: Rm405 Tower C H uahan Buil ding Langshan Rd16 Nanshan D istrict ShenZhen 518057 China
Tel: 86-755-3 3981668 F ax:86-75 5-8347- 5180
2010 - Version
-0.2Cx2h+2.4~2.45V/Cellx24h,Max. Current 0.3CA
-20 -10 0 5 10 20 25 30 40 45
6V&12V 50% 70% 83% 85% 90% 98% 100% 102% 104% 105%
2V 60% 75% 85% 88% 92% 99% 100% 103% 105% 106%
6V&12V 46% 66% 76% 83% 90% 98% 100% 103% 107% 109%
2V 55% 70% 80% 85% 92% 99% 100% 104% 108% 110%
AG MBattery
Capacity Factors With Different Temperature
Battery Type
GE LBattery