rt - weld evaluation comparison chart.xls
DESCRIPTION
RT- EvaluationTRANSCRIPT
WELD DISCONTINUITY EVALUATION GUIDE
1None Allowed. (QW-191.2.2)
2None Allowed. (QW-191.2.2)
3None Allowed. (QW-191.2.2)
4None Allowed. (QW-191.2.2)
5None Allowed. (QW-191.2.2)
6 _
7 _
8None Allowed. (QW-191.2.1)
SCOPE: THIS STANDARD IS A WELD DEFECT COMPARISON GUIDE. IT COMPARES THE REGULATONS WHICH SEVERAL CODES APPLY FOR EXAMINATION OF DEFECTS IN RADIOGRAPHIC FILMS.
ASME SEC-IX
API-650REFINERY PIPING API-1104PRESSURE VESSELS
Not covered (see undercut)
SPOT RADIOGRAPHYPIPING CODE 1104 - 1999
EDITION STORAGE TANK STD 650
NOV-1980 EDITION
ANSI PIPING CODE B31.3 - 1999 EDITION
SPOT RADIOGRAPHY
ASME SEC VIII DIV 1 - 1986 EDITION
100% RADIOGRAPHY
None Allowed (UW 51.b.1)
None Allowed (UW 51.b.1)
SERIAL NOTYPE OF
DISCONTINUITY
None Allowed (UW 51.b.1)
None Allowed (UW 51.b.1)
100% RADIOGRAPHY
CRACKS
INCOMPLETE PENETRATION @root pass (without high low)
INCOMPLETE FUSION @root pass
INCOMPLETE FUSION @side wall or between
beads (cold lap)
Smoothly contoured suck-up permitted if equal weld
reinforcement is provided. (UW-35.d)
The weld must be free of coarse ripples, grooves, overlaps abrubt ridges or
valleys. Any thickness reduction due to welding
shall not exceed the lesser of 1/32" or 10% of adjoining
wall thickness. (UW-35.a)
BURN - THROUGH
INTERNAL CONCAVITY
UNDERCUT @root pass or cap pass
None Allowed (UW 52.c.1)
None Allowed (UW 52.c.1)
None Allowed (UW 52.c.1)
None Allowed (UW 52.c.1)
None Allowed (UW 52.c.1)
Not covered (see undercut)
Smoothly contoured suck-up permitted if equal weld
reinforcement is provided. (UW-35.d)
The weld must be free of coarse ripples, grooves, overlaps abrubt ridges or valleys. Any thickness
reduction due to welding shall not exceed the lesser of 1/32" or 10%
of adjoining wall thickness. (UW-35.a)
None Allowed (Table341.3.2A)
None Allowed (Table341.3.2A)
None Allowed (Table341.3.2A)
None Allowed (Table341.3.2A)
None Allowed (Table341.3.2A)
Not covered (see Incomplete penetration)
Shall not reduced the total thickness of the joint, including reinforcement, to less than the
thickness of the thinner of component being welded.
None Allowed (Table341.3.2A)
None Allowed (Table341.3.2A)
Maximum depth of 1/32" or 20% of wall thickness. Whichever is smaller. Maximum length of 1-1/2" in 6" weld
SAME AS ROOT PASS (Table341.3.2A)
None Allowed (Table341.3.2A)
See ASME SECTION VIII DIV1 para UW-51(b), (6.1.5)
None allowed except on horizontal butt joints the maximum depth is 1/32".
Maximum depth of vertical joint is 1/64". (5.2.1.4)
INCOMPLETE PENETRATION (due
to high low)
None Allowed (UW 51.b.1)
The length of an individual indication of IF exceeds
2"(50mm). (9.3.5)
The maximum dimension of BT exceeds 1/4" (6mm). 9.3.7.1 /
9.3.7.2 & 9.3.7.3
None Allowed (Table341.3.2A)
Not covered (see Incomplete penetration)
Shall not reduced the total thickness of the joint, including reinforcement, to less than the
thickness of the thinner of component being welded.
Minimum depth of 1/32" or 25% of wall thickness. Whichever is
smaller. None allowed for longitudinal butt welds.
None Allowed (SEC VIII Div 1, UW-51(b)
Maximum of 1" in length in 12" of weld or 8% of weld length if the weld length is 300mm. (9.3.1)
The length of an individual indication of IP exceeds
2"(50mm). (9.3.2)
The length of an individual indication of IF exceeds
1"(25mm). (9.3.4)
None Allowed (9.3.10)
None Allowed (5.3.2.1)
None Allowed (5.3.2.1)
None Allowed (5.3.2.1)
None Allowed (5.3.2.1)
Any length of internal concavity is acceptable. (9.3.6 & 9.3.7)
The aggregate length of indications of cover pass (EU)
and root pass (IU) in any compination, in any continuous
12" (300mm) length of weld exceeds 2"(50mm) . see 9.7 and 9.3.11
Not covered (see undercut)
Compiled by: Mahesh Chandran. Zirku Island - UAE based on QGPC source document.
WELD DISCONTINUITY EVALUATION GUIDE
ASME SEC-IX
API-650REFINERY PIPING API-1104PRESSURE VESSELS
SPOT RADIOGRAPHYPIPING CODE 1104 - 1999
EDITION STORAGE TANK STD 650
NOV-1980 EDITION
ANSI PIPING CODE B31.3 - 1999 EDITION
SPOT RADIOGRAPHY
ASME SEC VIII DIV 1 - 1986 EDITION
100% RADIOGRAPHYSERIAL NO
TYPE OF DISCONTINUITY
100% RADIOGRAPHY
9Ref:
(QW-191.2.1)
10 _
11 _
12 _
Not covered.
Not covered.
ACCUMULATION OF DISCONTINUITIES
Not covered. Not covered. Not covered. Not covered.
Inside weld reinforcement shall not be raised above parent
material by more than(2mm) and (3mm) for outside reinforcement.
POROSITY
Maximum size for any indications shall be lesser of
1/4T or 5/32". An isolated indication seperated by
atleast 1" is the lesser of 1/3T or 1/4". For T>2" the maximum acceptable size
is3/8". (UA-65), (appendix 5)
Rounded indications are not a factor in the acceptability of welds
not required to be fully radiographed. (UW-52)
Maximum size for any indication shall be the lesser of 1/4T or
5/32". Isolated indications seperated by atleast 1" is the
lesser of 1/3T or 1/4T for T>2" . The maximum acceptable size is
3/8". No surface porosity is allowed.
EXCESSIVE ROOT PENETRATION
For T<1/4" reqirements the same as for 100% radiography. For
T>1/4" requirements are 1.5times those for 100% radiography. No
surface porosity is allowed.
The size of an individual pore exceeds 1/8" (3mm). The
size of an individual pore exceeds 25% of thinner of the nominal wall thickness joined. Reference:(9.3.9.1 / 9.3.9.2 /
9.3.9.9 & 9.3.9.4)
Excluding of Incomplete penetration due to high-low and undercutting, any accumulation of imperfections (AI) shall be considered a defect should any of the following conditions exist: 1. The aggregate length of indications in any continuous 12" length of weld exceeds 2". 2. The aggregate length of indications exceeds 8% of the weld length. (9.3.1.2)
Not covered.
Longitudinal butt weld: same as 100% X-ray, except as noted.
Rights of rejection since NDT methods give indications. The company may reject any weld which appears to meet these
standards of acceptability. If in its opinion. The depth of
discontinuity may be detrimental to the weld.
General UW-35, d
Same as weld reinforcement. (UW-35, d).
Same as weld reinforcement. (UW-35, d).
See ASME SECTION VIII DIV1 para UW-51(b), (6.1.5)
Same as weld reinforcement (Table 341.3.2A)
Same as weld reinforcement (Table 341.3.2A)
Compiled by: Mahesh Chandran. Zirku Island - UAE based on QGPC source document.
WELD DISCONTINUITY EVALUATION GUIDE
ASME SEC-IX
API-650REFINERY PIPING API-1104PRESSURE VESSELS
SPOT RADIOGRAPHYPIPING CODE 1104 - 1999
EDITION STORAGE TANK STD 650
NOV-1980 EDITION
ANSI PIPING CODE B31.3 - 1999 EDITION
SPOT RADIOGRAPHY
ASME SEC VIII DIV 1 - 1986 EDITION
100% RADIOGRAPHYSERIAL NO
TYPE OF DISCONTINUITY
100% RADIOGRAPHY
PLATE THICK
MAX. REINFORCEMENT
THICK
_
VERTICALHORIZONT
AL
<1/2" 3/32" 1/8"
1/2 TO 1" 1/8" 3/16"
WELD REINFORCEMENT
13
MATERIAL THICKNESS MAXIMUM HEIGHTTHINNER MATERIAL
THICKNESS: T,MAXIMUM HEIGHT
1" TO 2"
2" TO 3"
3" TO 4"
1 / 16" TO 3 / 32"
3/32" TO 3/16"
4" TO 5"
>5"
3/16" TO 1"
5/32"
7/32"
1/4"
1 / 32"
1/16"
3/32"
5/16"
1/8"
<1/4"
>1/4" TO 1/2"
>1/2" TO 1"
OVER 1"
<1/4"
>1/4" TO 1/2"
>1/2" TO 1"
OVER 1" >1" 3/16" 1/4"
MATERIAL THICKNESS
LONG. MAX: CIR. MAX:
Inside diameter of the component at ends to be joined must be
aligned within engineering design and welding procedure. If the external surfaces of the two
components are not aligned the weld shall be tapered between
the two surfaces.
Inside diameter of the component at ends to be joined must be
aligned within engineering design and welding procedure. If the external surfaces of the two
components are not aligned the weld shall be tapered between
the two surfaces.
The alignment of a butting ends shall minimize the offset between
surfaces. For pipe ends of the same nominal thickness, the
offset should not exceed 1/8"(3mm) larger variations are
permissible provided the variation is caused by variations of the
pipe end dimensions with in the pipe purchase specification
tolerances, and such variations have been distributed essentially uniformly around circumference of the pipe. Hammering of the pipe to obtain proper line up
should be kept minimum. (7.2)
NOT COVERED
1/4"t
>1/2" to 3/4" 1/8" 1/4"t
3/16"
1-1/2" to 2" 1/8" 1/8"t
14 MISALIGNMENT
3/4"t to 1-1/2" 1/8"
<1/2" 1/4"t
>2" lesser of (UW-33A)
1/16t or 3/8" 1/8t or 3/4"
Vertical misalignment <10% of 1/16". Whichever larger
(5.2.3.1). Horizontal misalignment <20% of upper
plate, with 1/8" maximum. (5.2.3.2). 1/16" misalignment is
allowed for plates less than 5/16" thick. (5.2.3.2).
_
Compiled by: Mahesh Chandran. Zirku Island - UAE based on QGPC source document.
WELD DISCONTINUITY EVALUATION GUIDE
ASME SEC-IX
API-650REFINERY PIPING API-1104PRESSURE VESSELS
SPOT RADIOGRAPHYPIPING CODE 1104 - 1999
EDITION STORAGE TANK STD 650
NOV-1980 EDITION
ANSI PIPING CODE B31.3 - 1999 EDITION
SPOT RADIOGRAPHY
ASME SEC VIII DIV 1 - 1986 EDITION
100% RADIOGRAPHYSERIAL NO
TYPE OF DISCONTINUITY
100% RADIOGRAPHY
MATERIAL THICKNESS
MAX. LENGTH
<3/4" 1/4"
3/4" TO 2-1/4" 1/3t
>2-1/4"Max. total leng. 12t
Ref: (QW-191.2.1)
Maximum length of 1/3T, maximum total length T in 12T of weld. Maximum width of 3/32" or
1/3T. T=wall thickness. (Table
341.3.2A).
Maximum length 2T, maximum width of 1/8" or 1/2T. Maximum total length 1/4T in 6" of weld
length. T=wall thickness. (Table 341.3.2A)
The length of an ESI indications exceeds 2". The aggregate length of indications in any
continuous 12" length of weld exceeds 2". (9.3.8.1, 9.3.8.2 &
9.3.8.3). ESI - Elongated Slag Inclusions
Welds examined by radiography shall be judged according to ASME SEC VIII DIV 1. PARA
UW-51(B), (6.1.5)
FOR >2-3/8" OD PIPE. FOR SMALLER
DIAMETER SEE 6.512 NAD 6.522.
15SLAG INCLUSIONS
ELONGATED EXCEPT AS NOTED
RADIOGRAPHIC FILMS ONLY SHOW DEFECTS IN TWO
DIMENSIONS, DEPTH OF DISCONTINUITIES CANNOT BE
DETECTED.
100% RADIOGRAPHY AND SPOT ARE QUALITY LEVEL DESIGNATIONS USED BY
THE ASME PRESSUER VESSEL AND ANSI PIPING CODES, AND CAN BE USED
TO EVALUATE OTHER METHODS OF NDT.
t=weld thickness
Maximum length of 2/3T, where T is thickness of material with 3/4"
maximum. Maximum total lengths of T in 6T weld length.
(UW-52.C.2)
REFERENCES : CODES AND REGULATIONS:
1 ASME BOILER AND PRESSURE VESSEL CODE, SECTION VIII DIV 1.
2 ANSI B 31.3, CHEMICAL PLANT AND PETROLEUM REFINERY PIPING.
5 ASME BOILER AND PRESSURE VESSEL CODE, SECTION 1 POWER BOILERS.
3 API 650 WELDED STEEL TANKS FOR OIL STORAGE TANKS.
4 API 1104, STANDARD FOR WELDING PIPE LINES AND RELATED FACILITIES.
Compiled by: Mahesh Chandran. Zirku Island - UAE based on QGPC source document.