2013 20232013 2014 2015 2016 2017 2018 2019 2020 2021 2022 2023
Initial Release of Premium Platform6/30/2013
Upgrade to the drive subsystem10/30/2014 End of standard warranty for current
Premium Platform
6/30/2019
End of maximum extended warranty for current Premium Platform
6/1/2023
Launch of next generation Premium Platform
6/30/2016
Honeywell and our partners are
committed to the long term support of the current premium
platform
Supportable
Simple
Scalable
Reliable
Compact
Same core value proposition is
retained
Premium Platform Refresh
Honeywell announced its intention to refresh the platform11/30/2015
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
What powers the Next Gen Platform?
Dell FX2
(Hardware)
VMware vSphere
(Hypervisor)
VMware Virtual SAN
(Network Storage)
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Parts of the FX2
Power
Supplies
PCIe Slots
IO Aggregator
Management
Module
Chassis
FD332
Storage
Block
FC630 Server
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Storage Sled
• Initial Honeywell config will be 2 SSDs and 6 regular drives per sled
• Has a capacity of 16 drives per sled
• Potential for additional future variations that will support very large
storage requirements of DVM for example
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Virtual SAN
• Software-defined storage
embedded in vSphere
• Pools HDD/flash into a
shared datastore
• High performance
through flash acceleration
• Highly resilient - zero
data loss in the event of
hardware failures
5
Virtual SAN
…
Hard disksSSD
Hard disksSSD
Hard disksSSD
Virtual SAN Shared
Datastore
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
ReliableScalable CompactSupportableSimple
12
3
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Simple
• Shared storage built
into the hypervisor
• Pre-Installed
Hypervisor and
Virtual SAN
• Pre-Configured IP
• Microsoft Datacenter
bundled
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Simple
• Next Gen Chassis
join together to form
a Next Gen Cluster
• No complicated
storage protocols or
controllers to master
• No additional
network top of rack
Next Gen Chassis
Next Gen Cluster
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Scalable
• Modular design
provides for future
expansion options
• PCIe NICs delivers
immense network
flexibility
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Scalable
Scale UPAdd more Disks
IOPSCapacity
12 TB
36 TB
Scale OUT
Add more
nodes
• Storage in each next
gen chassis is
globally accessible
• The more chassis,
the faster and larger
the storage pool.
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Traditional Premium Platform
Reducing Open Systems Churn
3-7 Years3-5 Years
Supportable
• Allows for the
more cost effective
used of long life
warranty contracts
• Longer availability
period than
standard hardware
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Supportable
12
vM
otio
n
vM
otio
n
• Non disruptive maintenance
• Rebalance hosts while VMs are
running
• Migrate from one generation of
hardware to another with zero
disruption and need to touch the
VM.
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Compact
Disk performance that is 20x faster than today
Density = Hardware Size + Performance
12 U
Essentials PlatformCurrent Premium
Platform
7 U6 U
Next Generation
Premium Platform
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Compact
PowerSpaceWeightCooling
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Reliable
• Automatically recover from a
faulty node or chassis
• Recover in minutes or
instantaneously with Fault
Tolerance
• Workloads are automatically
distributed to remaining hosts
Honeywell Confidential - © 2016 by Honeywell International Inc. All rights reserved.
Reliable
16
ESXi ESXi
Fast Checkpointing Sync
Primary Secondary
4 vCPU 4 vCPUPrimary
Instantaneous Failover
• Protect critical
applications with
fault tolerance
• No application
modifications
• Zero downtime,
Zero data loss.