rx10lft-is flush mount scissor lift rack spec sheet (site ... · specifications (refer to 6199-t...

2
SPECIFICATIONS RX10LFT-IS Flush Mount Lift Rack Site Specifications Substructure Requirements Refer to 6199-T for full details Power Requirements 208-230 VAC, single phase power, 26 Amp Air Supply Requirements 90-150 PSI (6.2-10.3 bar) Jacks require 125 PSI (8.6 bar) for full capacity Minimum Concrete Spec. 3 in. (76 mm) thick, 3000 PSI (20,700 kPA) rating Maximum Floor Slope 2 in. (51mm) over 126 in. (3200 mm) Product Specifications Max. Vehicle Weight 10,000 lbs. (4536 kg) Max. Wheelbase General Service 180 in. (4572 mm) Two-Wheel Alignment 175 in. (4445 mm) Four-Wheel Alignment 158 in. (4013 mm) Alignment Height All lock positions Min. Four-Wheel Alignment 88 in. (2235 mm) Lifting Speed 55 seconds Lowering Speed 25 seconds Form 6497-T, 06-15 Supersedes Form 6497-T, 12-12a Copyright © 2015, Hunter Engineering Company For lift rack information visit: www.hunter.com/lift-racks For local contact visit: www.hunter.com/contact-hunter For general inquiries visit: www.hunter.com or call 800-448-6848 MODEL FEATURES / DIMENSIONS Feature FT-IS 6000-lb Swing Air Jacks (2) Two-Speed Lowering Continued on Page 2 RX10LFT-IS Shown W1 H1 H2 L Dimension Outside Width (W1) 88.5 in. 2248 mm Inside Width (W2) 40 in. 1016 mm Length (L) 228.375 in. 5801 mm Runway Width (R) 24 in. 610 mm Raised Height (H1) 72 in 1829 mm Depth (H2) 9.25 to 10.25 in. 235 mm to 260 mm W2 R

Upload: vuongnguyet

Post on 10-Nov-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

SPECIFICATIONS

RX10LFT-ISFlush Mount Lift Rack

Site Specifications

Substructure Requirements Refer to 6199-T for full details

Power Requirements 208-230 VAC, single phase power, 26 Amp

Air Supply Requirements 90-150 PSI (6.2-10.3 bar)Jacks require 125 PSI (8.6 bar) for full capacity

Minimum Concrete Spec. 3 in. (76 mm) thick, 3000 PSI (20,700 kPA) ratingMaximum Floor Slope 2 in. (51mm) over 126 in. (3200 mm)

Product SpecificationsMax. Vehicle Weight 10,000 lbs. (4536 kg)

Max. Wheelbase General Service 180 in. (4572 mm) Two-Wheel Alignment 175 in. (4445 mm) Four-Wheel Alignment 158 in. (4013 mm)Alignment Height All lock positionsMin. Four-Wheel Alignment 88 in. (2235 mm)Lifting Speed 55 secondsLowering Speed 25 seconds

Form 6497-T, 06-15Supersedes Form 6497-T, 12-12a

Copyright © 2015, Hunter Engineering Company

For lift rack information visit:www.hunter.com/lift-racks

For local contact visit:www.hunter.com/contact-hunter

For general inquiries visit:www.hunter.com

or call800-448-6848

MODEL FEATURES / DIMENSIONS

Feature FT-IS

6000-lb Swing Air Jacks (2)

Two-Speed Lowering

Continued on Page 2

RX10LFT-IS Shown

W1

H1

H2

L

Dimension

Outside Width (W1) 88.5 in.2248 mm

Inside Width (W2) 40 in.1016 mm

Length (L) 228.375 in.5801 mm

Runway Width (R) 24 in. 610 mm

Raised Height (H1) 72 in1829 mm

Depth (H2) 9.25 to 10.25 in.235 mm to 260 mm

W2 R

SPECIFICATIONS (Refer to 6199-T for substructure construction requirements)

RX10LFT-ISFlush Mount Lift Rack

Form 6497-T, 06-15Supersedes Form 6497-T, 12-12a

Copyright © 2015, Hunter Engineering Company

Dimensions shown are for finished pits. Tile thickness (if applicable) must be considered before pouring pit.

*Non-standard positioning of control console is limited to a maximum space between console and rack of 6 feet (1829 mm) at the approach ramp end and 18 feet (5486 mm) at the turnplate end. Additional threshold and perhaps hydraulic hoses will be required (refer to Installation Instruction for details).

! WARNING

!WARNING

!WARNING

!WARNING

DRAINLOCATED

INCENTEROF PIT

SLOPEPIT

FLOORTOWARD

DRAIN(1/2")

CONSOLE CONDUIT DETAIL

92 1/2"(2350 mm)

! WARNINGSTAY BEHINDYELLOW LINE

WHEN THELIFT MOVES.

128-978-2

DECAL 128-978-2

OPTIONAL CONSOLE LOCATION

(4 places on edging and 2 places on lift)

41 3/8"(1051 mm)

141 3/4"(3600 mm)

14"(356 mm)

APPROX. 2"(51 mm) TYPICAL

14"(356 mm)

5"(127 mm)

5"(127 mm)

14" X 5"CUTOUT(4 places)

ANGLE AROUND PIT PERIMETER:- not around

- painted safety yellow- not supplied by Hunter

14" X 5"cutouts

16"(406mm)

22"(559 mm)

6" MIN.*152 mm( )

OPTIONAL 1 1/2" DIA. CONDUITFOR COMMUNICATION CABLE

TO ALIGNMENT CONSOLE

HAWKEYE SERIES SENSORSAND PRONTO SYSTEMS HAVE

SPACE REQUIREMENTS INFRONT OF LIFT THAT MUST BEMET, REFER TO APPROPRIATE

SITE REQUIREMENTS.

ENTIRE PIT(BOTTOM AND WALLS)

MUST BE HARDTROWEL FINISH

FILLER PLATE51-2308-1(4 places)

(placed over14" X 5"cutout)

34 3/4"(883 mm) EXTENDER

PLATES51-2464-1-PPP

ANDRAMPS

147-141-1-PPP

RAMPS147-141-1-PPP

66 3/4"(1695 mm)

228 3/8"(5801 mm)

30 3/4"(781 mm)

BAY DOOR BAY DOOR

45

6" MIN.RADIUS CONDUIT

EXIT FLUSHWITH

PIT FLOOR

ROUTE 4" MIN DIAMETERCONDUIT OR EQUIVALENTCLOSED CHANNEL FROMPIT FLOOR TO BASE OF

CONSOLE

VEHICLE APPROACH

* LONGER VEHICLES WILL NEED TO BE SERVICED WITH BAY DOOR OPEN. TOACCOMMODATE MOST VEHICLES, INCREASE SPACE BEHIND PIT TO ( ) ORGREATER.

39" 991 mm** SITES WITH D.R.W. TRUCKTRAFFIC SHOULD USE 20" MIN.CONSOLE TO PIT DISTANCE.

**15" TO 41"

(381 TO 1041 mm)