    Thank you for purchasing our product. Before you start using your server, please read carefully the additionalnotes described below.

    December 2008FUJITSU LIMITED

    1 Setting for onboard LAN controller on Windows Server 2003 or Windows Server 2003 x64

    [IMPORTANT]When the server runs on Windows Server 2003 or Windows Server 2003 x64, the onboard LANcontroller may not work properly (*) with some applications. To avoid the symptom, make sure todisable the TCP Chimney Offload setting by following the instruction below.

    Copyright FUJITSU LIMITED 20081

    1. Start Windows Server 2003 or Windows Server 2003 x64.2. Select [Start] - [Run] and type in "cmd" to activate the command prompt.3. Enter the following command on the command prompt and press

    4. When the setting change is completed, "OK" is output.(You do not need to restart the server after this command.)

    * Example of the cases where the LAN controller does not work properly.1) When the data transfer is performed through FTP.1-1 "426 Connection Closed; transfer aborted" is displayed.1-2 The FTP connection is disconnected and the data cannot be transferred through FTP.

    2) When an application that connects to SQL Server by using TCP/IP is used, you may intermittentlyreceive one of the following error messages when the application connects to SQL Server.2-1 [Microsoft] [ODBC SQL Server Driver] [DBNETLIB] General Network error

    Refer to the network manuals in this case.2-2 [Microsoft] [SQL Native Client] Communication link failure

    2-3 System.Data.SqlClient.SqlException: A transport-level error has occurred when sending therequest to the server.

    2 Warning Messages of ServerView Remote Connector upon OS startup

    [Symptom]When all the conditions described later are met, the warning message below may berecorded on the Application Event Log upon the startup of the server.

    Type: WarningSource: ServerView Remote ConnectorEvent ID: 0Description:

    Initialization not completed timely (0 seconds)

    Note on using PRIMERGY RX300 S4

    C:> Netsh int ip set chimney DISABLED

    [Conditions]1) ServerView Agent for Windows is installed, and2) The system is highly-loaded during startup.

    [Cause]The heavy load during the system startup causes the delay in the processing to initializeServerView Remote Connector. This warning message is to report that the service startup isnot completed within the certain period of time, and not that the service startup has failed.

    [Remedy]

    Even if the message is recorded due to the delay in the processing to initialize theServerView Remote Connector service, the processing continues. The service isautomatically started after the completion of the initialization, so no special action is required.

    * The ServerView Remote Connector service is used with the following ServerView functions. Even if

  • 7/30/2019 Rx300 S4

    2/5

    this service is not active, no other functions are affected.- Performance Manager- Power Monitor

    Supplementary Information: How to ConfirmFollow either of the procedures below to confirm whether the ServerView Remote Connector service isrunning normally.1) When Performance Manager is used

    Start the Performance Manager from the ServerView S2.

    Select the server for which you want to confirm the ServerView Remote Connector service

    operation from the left side frame.

    Select the [Report View] tab.

    Select any report, and click on the [Show >>] button.

    If the graph is displayed, the ServerView Remote Connector service is running normally and nochange is required. When the service is not running normally, the following dialog is displayed.

    Note: It is necessary to make the report setting beforehand.For the usage of Performance Manager, refer to "ServerView User's Guide".

    2) When Power Monitor is used

    Start the Power Monitor from the ServerView S2.

    Select the server for which you want to confirm the ServerView Remote Connector service

    operation from the left side frame.

    Select the [Data] tab.If the graph is displayed, the ServerView Remote Connector service is running normally and nochange is required. When the service is not running normally, the following dialogs are displayed.

    A) The following dialog box is displayed and left open.

    B) After the dialog in (A), the following window is displayed.

    Note: For the usage of Power Monitor, refer to "ServerView User's Guide".

    When the ServerView Remote Connector is not running normally, restart the service by following theprocedure below. (There is no need to reboot the system.)

    [Control Panel] - [Administrative Tools] - [Services] - [ServerView Remote Connector]Select

    3. About the latest ServerView

    ServerView in "PRIMERGY StartUp Disc" attached to this product does not support BIOS1.09/iRMC 3.32A.

  • 7/30/2019 Rx300 S4

    3/5

    Please download and use ServerView from the following URL when you use BIOS 1.09/iRMC3.32A.

    http://www.fujitsu.com/global/services/computing/server/ia/driver/

    *The number of version of BIOS is displayed in the first line on the POST screen.

    A part surrounded with a frame is the number of the version of the BIOS.

    PhoenixBIOS Version 4.06 Rev. 1.01 . 2529

    You could confirm the iRMC firmware version in the following steps.

    - BIOS SetupTurn on the server and press F2 key to go to BIOS setup window. Then open "Info" window by pressing F1 keyto check the iRMC firmware version.

    example) iRMC Firmware 001.66A

    4 Updates for "PRIMERGY RX300 S4 User's Guide" (B7FH-5171-01EN)

    Chapter 6 "6.4.2 Installable Memory Board/Memory Modules, and Notes" (Page 128)

    How to identify a memory module

    CorrectionThere is an incorrect description under the "How to identify a memory module ".

    Incorrect:

    Identification label

    Correct:

    Identification label A Identification label B Identification label C

    1

    Addition

    Add the "Identification label patterns" table below.

    Identification label patterns

    When a memory module is placed with the circled corner in the above figure shown on the lower left

    side, the identification labels are applied in one of the following patterns.

    Table: Identification Label Patterns

    Pattern Label A Label B Label C

    1 - - -

    2 Applied - -

    3 - Applied -

    4 - - Applied

    5 Applied Applied -

    6 Applied - Applied

    7 - Applied Applied

    8 Applied Applied Applied

    Chapter 6 "6.6.1 Installation Locations of Internal Hard Disk Units" (Page 146)

    Installation order

    Update

    Copyright FUJITSU LIMITED 20083

    Installation order of internal hard disk units changed from this product.

    http://www.fujitsu.com/global/services/computing/server/ia/driver/http://www.fujitsu.com/global/services/computing/server/ia/driver/
  • 7/30/2019 Rx300 S4

    4/5

    table: Installation order of internal hard disk units

    Status of the 3.5-inch storage

    bay

    Installation order

    Standard installation Bay 4Bay 5Bay 6Bay 1Bay 2Bay 3

    When an internal backup device

    is installed (using bays 2 and 3)

    Bay 4Bay 5Bay 6Bay 1

    Chapter 7 "7.2 BIOS Setup Utility"7.2.6 Peripheral Configuration Submenu (Page 174)

    Correction

    Incorrect:

    Item Setting Description

    P_ATA Maps To Secondary (Unchangeable) Sets the Parallel ATA mode.

    Correct:

    Item Setting Description

    P_ATA Maps To DisabledSecondary (Initial value)

    Sets the Parallel ATA Controller mode.When VMware is used, set this item to"Disabled".

    7.2.8 Advanced System Configuration Submenu (Page 177)Addition

    Add the following item under the "Memory Redundancy" in the "Items on the Advanced SystemConfiguration Submenu" table.

    Item Setting Description

    High Bandwidth Enabled (Unchangeable) Configures FSB (Front Side Bus).

    7.2.8 Advanced System Configuration Submenu" (Page 177)

    Correction

    Incorrect

    Table: Advanced System Configuration submenu

    Item Setting Description

    Enhanced Speed Step Disabled(Unchangeable) Sets whether or not to use the power savingfunction. This item may not be displayed dependingon CPU.

    Correct

    Table: Advanced System Configuration submenu

    Item Setting Description

    Enhanced Speed Step DisabledInitial value

    Enabled

    Sets whether or not to use the power savingfunction. This item may not be displayed dependingon CPU.Note:This item is changeable only when Windows systemis installed.

    7.2.11 Security Menu (Page 181)

    Addition

    Add the following item under the "Flash Write" in the "Items on the Security Menu" table.

    table: Items on the Security MenuItem Setting Description

    TPM (Security Chip)Setting

    Configures the TPM (Security Chip) settings.Press the [Enter] key to display the "TPM (Security CHip) Setting" submenu.

    Add the following table under the above "Items on the Security Menu" table.

    talbe: Items on the TPM (Security Chip) Setting Submenu

    Item Setting Description

    Security Chip Disabled (Initial value)Enabled

    Sets whether to enable or disable Security Chip.

    Current TPM State Displays the current state of the TPM.

    Change TPM State No Change (Initial

    value)

    Enable & Activate

    Changes the state of the Security Chip. (*)

  • 7/30/2019 Rx300 S4

    5/5

    Disable & Deactivate

    Clear

    *: If rebooted after changing the TPM state, the BIOS Setup Utility may start upon completion of thePOST.

    In that case, click [Execute] when the following "Physical Presence operations" submenu isdisplayed,

    and the changed setting will be on.

    Appendix "A Server Specifications" (Page 220)

    Addition

    Add the items below to the "Server Specifications" table.

    table: Server Specifications

    Item Functions and Specifications

    Product ID PGUR3041A3CPU CPU Conversion kit Intel Xeon Processor X5260 (3.33GHz/6MB)

    Intel Xeon Processor X5270 (3.50GHz/6MB)Intel Xeon Processor E5405 (2GHz/12MB)

    Intel Xeon Processor E5420 (2.50GHz/12MB)Intel Xeon Processor X5460 (3.16GHz/12MB)Intel Xeon Processor X5470 (3.33GHz/12MB)

    Security Chip TCG 1.2 compliant (*)

    * This function is only available for Windows Server 2008.

    For the latest information on Windows Server 2008 support, refer to the "Support Matrix" at:

    http://www.fujitsu.com/downloads/PRMRGY/support-matrix.pdf

    5.Correction of "PRIMERGY RX300 S4 Contents List" (CA92276-8047-01)

    Attachment items:

    Deletion

    Delete the following item from the list.

    Tag Label

    Copyright FUJITSU LIMITED 20085