s12

38
R OPS BSC SMP SCP MD SPP Other NEs Management Center SCE International Gateway VOD IMM ADSI Analog CLASS ISDN RSU Business Communication BTS BTS Toll/SDH SDH+ATM Evolution RSU RSU RSU JSSA ATOM Toll RTSU Local MSC DCN ALMA SSP STP Local תתתתתתתSYSTEM 12

Upload: iitzik

Post on 28-Nov-2014

77 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: S12

1RR

OPS

BSC

SMP

SCP

MD

SPP

Other NEs

ManagementCenter

SCE

InternationalGateway

VOD

IMM

ADSI

AnalogCLASS

ISDN

RSU

Business Communication

BTS

BTS

Toll/SDHSDH+ATM

Evolution

RSURSURSU

JSSA

ATOM

Toll

RTSU

Local

MSC

DCN

ALMA

SSP STP

Local

עקרונות SYSTEM 12

עקרונות SYSTEM 12

Page 2: S12

2RR

ISDN

Analogue Exchange

ISDN

Remote Unit

NSC

TAX CENTER

PABX

Public Switched Telephone NetworkPublic Switched Telephone NetworkPublic Switched Telephone NetworkPublic Switched Telephone Network

ISDN

Network ServiceCenter (NSC)

Page 3: S12

3RR

ושימושים ושימושים גדלים ושימושים S.12 S.12 גדלים ושימושים גדלים S.12 S.12 גדלים

.100מעל • מנויים אלף

.60מעל • עורקים אלף

•. קצה מרכזות

•. מעבר מרכזות

•. שונים לשירותים שער מרכזות

•. בינלאומיות מרכזות

לעמדות )• (.166, 144, 188מרכזות

• / , מעבר ) / מעבר מקומיות משולבות מרכזות

בינלאומיות(.

Page 4: S12

4RR

כלליים כלליים מאפיינים כלליים S.12S.12מאפיינים כלליים מאפיינים S.12S.12מאפיינים

.LOAD SHARING, ACTIVE/STANDBY

.HOT STANDBY, CROSSOVER

רשת מיתוג ספרתית בלתי חסימה.•

(.29 מספר מינימלי של סוגי כרטיסים )כ - •

מודולים יחודיים לפונקציות שונות.•

גידול מודולרי של הרשת.•

מגוון סוגי ציוד היקפי.•

שיטות שונות של חלוקת עומס וטכניקות גיבוי: •

Page 5: S12

5RR

Fully Digital

Full Range

Fully Distributed

Fail Safe

Future Safe

The S.12 ConceptThe S.12 ConceptThe S.12 ConceptThe S.12 Concept

Page 6: S12

6RR

SYSTEM 12SYSTEM 12טכנולוגי טכנולוגי קידום קידום

SYSTEM 12SYSTEM 12טכנולוגי טכנולוגי קידום קידום

Technology Bipolar + 5 µM NMOS

Power 35 KW

PBA Types 47

# PBA 3694 # Racks 34

Technology BCD + 1,2/0,8 µM CMOS

Power 9 KW

PBA Types 29

# PBA 1282

# Racks 9

Technology Bimos + 3 µM NMOS

Power 24.2 KW

# PBA 3383

# Racks 20

PBA Types 43

10,000 Line Exchange

# Racks 34

# Racks 20

# Racks 9

ALIC : Advanced Line Circuit

ELC : Evolutionary Line Circuit

NGLC : New Generation Line Circuit

ALIC 1983ALIC 1983

ELC 1986ELC 1986

NGLC 1991NGLC 1991

Page 7: S12

7RR

A1000 S.12 RACKA1000 S.12 RACKA1000 S.12 RACKA1000 S.12 RACK

Page 8: S12

8RR

DOOR DOOR

AIR BAFFLELOCATION

(IF PROVIDED)

TYPICAL SUBRACK(SINGLE SHELF)

THE S.12 RACK PARTSTHE S.12 RACK PARTSTHE S.12 RACK PARTSTHE S.12 RACK PARTS

Page 9: S12

9RR

מרכיבים - ציבורית מרכיבים - מכרזת ציבורית מכרזתעיקרייםעיקריים

מרכיבים - ציבורית מרכיבים - מכרזת ציבורית מכרזתעיקרייםעיקריים

רשתמיתוגרשתמיתוג

עיבודנתוניםעיבודנתונים

קישוראחרות למרכזות

קישוראחרות למרכזות

סנכרוןשעון והפצת

סנכרוןשעון והפצת

קישורבמנויים ותמיכה

קישורבמנויים ותמיכה

ציודאיתותציוד

איתות

ציודהקפיציודהקפי

ניהולותחזוקה

ניהולותחזוקה

Page 10: S12

10RR

עיקריות עיקריות יחידות עיקריות SYSTEM 12SYSTEM 12יחידות עיקריות יחידות SYSTEM 12SYSTEM 12יחידות

DSNDSN

AUXILIARYCONTROLELEMENT

AUXILIARYCONTROLELEMENT

DIGITALTRUNK

MODULE

DIGITALTRUNK

MODULE

CLOCK &TONE

MODULE

CLOCK &TONE

MODULE

ANALOGSUBSCRIBER

MODULE

ANALOGSUBSCRIBER

MODULE

SERVICECIRCUITMODULE

SERVICECIRCUITMODULE

MAINTENACE&

PERIPHERAL

MAINTENACE&

PERIPHERAL

Page 11: S12

11RR

SPIDER DIAGRAMSPIDER DIAGRAMSPIDER DIAGRAMSPIDER DIAGRAM

CE

DigitalSwitchingNetwork

M & PCE

C & TCE

LTCE CE

TTCE CE

SYSTEMTCE

CE

n

n

n

n

n

1

12

1

1

1

1

Page 12: S12

12RR

SYSTEM 12SYSTEM 12SPIDER DIAGRAMSPIDER DIAGRAM

SYSTEM 12SYSTEM 12SPIDER DIAGRAMSPIDER DIAGRAM

ASM : Analog Subscriber Module

ISM : ISDN Subscriber Module

IRIM : Remote Interface Module

IPTM : ISDN Packet Trunk Module

DTUA : Digital Trunk Module

DECM : Digital Echo Canceller Module

MIM : Mobile Interface Module

SCM : Service Circuit Module

DIAM : Digital Announcement Module

TTM : Trunk test Module

C&T : Clock and Tone Module

P&L : Peripheral and Load Module

ACE : Aux. Control Element

CE : Control Element

DLM : Data Link Module

CECE

CECE

CECE

ASM ASM CECE

ISM ISM CECE

IRIM IRIM CECE

IPTM IPTM CECE

DTUA DTUA CECE

DECM DECM CECE

MIM MIM CECE

P&L P&L

C&T C&T

TTMTTM

DIAM DIAM CECE

SCMSCMCECE

DSN DSN

CE

ACE

CECE DLMDLM

CE

DEF

2X

2X

Page 13: S12

13RR

CLUSTERCLUSTER

LOCAL CALLLOCAL CALLLOCAL CALLLOCAL CALL

DSNDSNDSNDSNCECE CECE CLUSTERCLUSTER

CECE

CECE CLUSTERCLUSTER

USER SW

CS

DB

PROCESSOR

TO DSNTOCLUSTER

TERMINALINTERFACE

ACE

ASMASM

SCM

Page 14: S12

14RR

ACCESS SWITCH CONNECTIONSACCESS SWITCH CONNECTIONSACCESS SWITCH CONNECTIONSACCESS SWITCH CONNECTIONS

Page 15: S12

15RR

Network Structure with four PlanesNetwork Structure with four PlanesNetwork Structure with four PlanesNetwork Structure with four Planes

Page 16: S12

16RR

1536 ANALOG LINES

240 TRUNK CHANNELS

LINE RACKLINE RACKLINE RACKLINE RACK

Page 17: S12

17RR

Subscriber Module - ASMSubscriber Module - ASMSubscriber Module - ASMSubscriber Module - ASM

MCUBMCUB

ALCN - 1ALCN - 1 ALCN - 2ALCN - 2 ALCN - 7ALCN - 7 ALCN - 8ALCN - 8

TAUCTAUC RNGFRNGF

DC / DCDC / DC1 ALCB = 8 SUBSCRIBERS1 ALCN= 16 SUBSCRIBERS

EC7 1 TAUC PER 4 MODULESEC5 1 TAUC PER 8 MODULES

Page 18: S12

18RR

Analog Subscriber Module structureAnalog Subscriber Module structureAnalog Subscriber Module structureAnalog Subscriber Module structure

ALCNA

B

0

16

1

4

ALCNA

B

0

16

1

4

ALCNA

B

0

16

1

4

ALCNA

B

0

16

1

4

16x4=6464x2=128 LINES

16x4=6464x2=128 LINES

1 2

3 4

TO DSN

MCUA

1 2

3 4

TO DSN

MCUA

ASM `A`

ASM `B`

PCM LINKS4 Mb/S

RNGF

RNGF TAUC/RLMC

Page 19: S12

19RR

DTUADTUA DSNTrunk

DTUA (DTM-L)DTUA (DTM-L)DTUA (DTM-L)DTUA (DTM-L)

Page 20: S12

20RR

ASMASMDTMDTM

DTM-LDTM-LHCCMHCCM

SCMSCM

DTM-HDTM-H

DSNDSNDSNDSN

ISMISM

DTMDTM

DSNDSNDSNDSN

PCM LINK

EXCHANGE BEXCHANGE A

Switch Connection Via DTMSwitch Connection Via DTMSwitch Connection Via DTMSwitch Connection Via DTM

Page 21: S12

21RR

• HDB3 / BIN

• RETIMING

• FRAME ALIGN.

• CRC-4

• ALARMS

• 8 / 16 BITS

R

T

R

T

R

T

R

T

PACKETRAM

FIFO

REGISTERS

ACCESS CIRCUITTO TRUNK (TRAC)

PHYSICAL INTERFACEWITH THE LINE

8086

EXTERNAL RECOVERED

CLOCK (2 Mb/s)PROM, RAM

PROCESSOR

TO C&TMODULE

2 Mb/s

DTUA

TI PART

DTUA block diagramDTUA block diagramDTUA block diagramDTUA block diagram

R

Page 22: S12

22RR

DTRIDTRI MCUBMCUB DSNTrunk

IPTM = Integrated Packet Trunk ModuleIPTM = Integrated Packet Trunk ModuleDTM-highDTM-high

IPTM = Integrated Packet Trunk ModuleIPTM = Integrated Packet Trunk ModuleDTM-highDTM-high

Page 23: S12

23RR

DTUA

MCUA

SLTA

channel anyone withsignalling message

ch 16

1

2

8

High-performance Common Channel Module (HCCM)High-performance Common Channel Module (HCCM)High-performance Common Channel Module (HCCM)High-performance Common Channel Module (HCCM)

OBCI

2 1

3

4

OBC(80186)

RAM

DOUBLEPORT

MEMORY

SIGNALCONTRL

(80186)

RAM

FLAG

ILC

Routing&d

level 2process

4.116120 page 81

Page 24: S12

24RR

P&L = Peripheral P&L = Peripheral andand

Load ModuleLoad Module

P&L = Peripheral P&L = Peripheral andand

Load ModuleLoad Module

MAG. TAPE

ACT

URG CLMA non-URG

Ext. Alarm (16)

Rem. Alarm (2)

Lamp. Drive (20)

RLMC64 Alarms input

Lamp. Drive (4)

DMCA

MMC ITF.

MMCA

MMC ITF.

MCUB DSN

HARD (System)DISK

BOOT

OPTICALDISK

BUILD/BACKUP

FORMATTERMAG. TAPE

MULTIMASTERBUS

Peripheral Bus

To othet P&L DF

ClusterLink

ADAP

SCSI BUS (Max 8 periph.)

Page 25: S12

25RR

DSGACLTD

CLTD

CLTD

MCUA

RCLA

Tone Distribution Tone Distribution Tone Distribution Tone Distribution

Row Lead Rack Any Rack in the same row

Clock1

6

RCLA

Clock

1

6

TI

5

MCUB

TI

1

20

1

20

1

20DSGACLTD

MCUB

TI

1

20

C&T Modules

ClockRegeneration

Page 26: S12

26RR

Active

CCLA RCCB CLTD

Hot Stand By

CCLA RCCB CLTD

CLTD

CLTD

8 MHz

RCLA

RCLA

A

B

B

A

Switch orCE PABs

Clock Distribution SchemeClock Distribution SchemeClock Distribution SchemeClock Distribution Scheme

Row Lead Rack Any Rack in the same row

Page 27: S12

27RR

ISDNSubscriber

Mudule

TA

TA

NT

a

b

Four wiresS

Interface

4

2 2

Subscriber loop(two copper wires)

A1000 S12 Exchange

B B D

B B 4

PC

Basic access diagramBasic access diagramBasic access diagramBasic access diagram

Page 28: S12

28RR

• SW MODULES

– Black box

– O.S.

– Messages

SOFTWARESOFTWARESOFTWARESOFTWARE

• DATA BASE

– Relational

– Distributed

– Full accessible

Page 29: S12

29RR

SOFTWARE MODULESOFTWARE MODULESOFTWARE MODULESOFTWARE MODULE

Black BoxBlack Box

Massage

Massage

Massage

Massage

Massage

Data from relations

Page 30: S12

30RR

DISTRIBUTED DATABASEDISTRIBUTED DATABASEDISTRIBUTED DATABASEDISTRIBUTED DATABASE

DigitalSwitchingNetwork

DigitalSwitchingNetwork

CECE

DBDB

LTCELTCE CECE

DBDB

TTCETTCE CECE

DBDB

M & PM & PCECEDBDB

C & TC & TCECE

DBDB

SYSTEMTCE

SYSTEMTCE

CECE

DBDB

Page 31: S12

31RR

SYSTEM 12 SOFTWARESYSTEM 12 SOFTWARESYSTEM 12 SOFTWARESYSTEM 12 SOFTWARE

DATABASE

SWMODULE

SWMODULE

OS

CE 1

DATABASE

SWMODULE

SWMODULE

OS

CE 2

DSNDSN

MASSAGES

Page 32: S12

32RR

SOFTWARE BUILDING BLOCKSSOFTWARE BUILDING BLOCKSSOFTWARE BUILDING BLOCKSSOFTWARE BUILDING BLOCKS

P&L control

ASM control

SCM control

control CTM

control DTM

control

DSN

control

spare ACE

system ACE

Operating System

Database

Telephonic Support

Call Handing

Administration

Maintenance

5.1

Page 33: S12

33RR

. איתות בין מרכזתי ברשתות טלפוניה.1

.ISDN. איתות בין מרכזתי ברשתות 2

. העברה הודעות בין המרכזות למרכזי פיקוח, תחזוקה וניהול 3

הרשת.

. העברת נתוני מנייה למרכז ענ”א.4

.IN. תשתית לרשת נבונה 5

. העברת נתוני מנייה למרכז ענ”א.6

.IN. תשתית לרשת נבונה 7

77שיטת איתות מס’ שיטת איתות מס’ 77שיטת איתות מס’ שיטת איתות מס’

Page 34: S12

34RR

).ISDN 256 מנויים או 512 מנויים (ימ”ר - 488קישור עד •

מתן כל השירותים והתכונות ע”י מרכזת האם.•

תחזוקה מלאה של קוי המנויים ממרכזת האם.•

תחזוקה של מרכזת האם גם מיחדת רחק.•

מרכיבי חומרה סטנדרטיים.•

•Stand Alone Mode.במצב חרום -

.7קשר עם מרכזת האם בשיטת איתות מס’ •

ובאמצעותה לכל הרשת.•

RSURSU תכונות עיקריות - תכונות עיקריות - RSURSU תכונות עיקריות - תכונות עיקריות -

Page 35: S12

35RR

RSURSUשילוב מערכתי - שילוב מערכתי - RSURSUשילוב מערכתי - שילוב מערכתי -

SYSTEM 12HOST EXCHANGE

SYSTEM 12HOST EXCHANGE

RIM

RSURSU

RIM

PCM LINK

OR RADIO

Page 36: S12

36RR

IRSU IRIMPCMLINES

A1000 S12

IRSU point to point configurationIRSU point to point configurationIRSU point to point configurationIRSU point to point configuration

Page 37: S12

37RR

IRSU / IRIM with DTRFIRSU / IRIM with DTRFIRSU / IRIM with DTRFIRSU / IRIM with DTRF

END

Page 38: S12

38RR

Slides ListSlides List Slides ListSlides List

2. P S T N

S.12 גדלים ושימושים .3

4. S12 - מאפיינים כלליים

5. The S.12 Concept

6. SYSTEM 12 קידום טכנולוגי

7. A1000 S.12 RACK

8. THE S.12 RACK PARTS

מכרזת ציבורית - מרכיבים 9עיקריים .

10. SYSTEM 12 יחידותעיקריות11. SPIDER DIAGRAM

12. Full SPIDER DIAGRAM

13. LOCAL CALL

14. A S CONNECTIONS

15. DSN with four Planes

16. LINE RACK

17. ASM

18. ASM Structure

19. DTUA (DTM-L)

20. DTM Connection

21. DTUA block diagram

22. IPTM

23. HCCM

24. P&L

25. Tone Distribution

26.Clock Distribution

27.Basic Access

28.SOFTWARE

29.SOFTWARE MODULE

30. DISTRIBUTED DB

31. SYSTEM 12 SOFTWARE

32. SW BLOCKS

33. No. 7

34. RSU תכונות

35. RSU - שילוב מערכתי

36. IRSU PTP config.

37. IRSU / IRIM with DTRF