saa sucs - command access€¦ · saa sucs visit our website for more details u.s. customer support...

4
SGTREXKIT-M-ED Doc # 20082_A INSTALLATION INSTRUCTIONS Visit our website for more details www.CommandAccess.com U.S. Customer Support 1-888-622-2377 Canada Customer Support 1-855-823-3002 The SGTREXKIT-M-ED is a field installable Request-to-Exit switch for SLP-UL-M-KIT, Sargent motorized latch pullback kit. The switch is SPDT (single pull, double throw). Kit Includes A. 1 -REX sticker B. 2 - Phillips head screws C. 2 - Washers D. 1 - Cable tie mount E. 1 - REX switch with 4’ Lead F. 1 - Cable tie Tools Required Phillips head screwdriver B. A. C. E. D. F.

Upload: others

Post on 08-May-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SAA SUCS - Command Access€¦ · SAA SUCS Visit our website for more details U.S. Customer Support 1-888-622-2377 Canada Customer Support 1-855-823-3002 The SGTREXKIT-M-ED is a field

SGTREXKIT-M-ED

Doc # 20082_A

I N S T A L L A T I O N I N S T R U C T I O N S

Visit our website for more detailswww.CommandAccess.com

U.S. Customer Support1-888-622-2377

Canada Customer Support1-855-823-3002

The SGTREXKIT-M-ED is a field installable Request-to-Exit switch for SLP-UL-M-KIT, Sargent motorized latch pullback kit. The switch is SPDT (single pull, double throw).

K it I nc ludesA. 1 -REX stickerB. 2 - Phillips head screwsC. 2 - WashersD. 1 - Cable tie mountE. 1 - REX switch with 4’ LeadF. 1 - Cable tie

Tools Required• Phillips head screwdriver

B.

A.

C.

E.

D.

F.

Page 2: SAA SUCS - Command Access€¦ · SAA SUCS Visit our website for more details U.S. Customer Support 1-888-622-2377 Canada Customer Support 1-855-823-3002 The SGTREXKIT-M-ED is a field

• Remove end cap and filler plate.

• Line REX switch up with activating lever

to the left & install both screws. Do not

overtighten. When device is activated

motor block will move forward & trigger

switch.

• Locate two pre-tapped holes on motor

bracket.

• Place small plastic washers (C) on screws

(B) provided.

Activating Lever

• Test make sure switch is making proper

contact depress push pad.

Page 3: SAA SUCS - Command Access€¦ · SAA SUCS Visit our website for more details U.S. Customer Support 1-888-622-2377 Canada Customer Support 1-855-823-3002 The SGTREXKIT-M-ED is a field

• Test switch to confirm proper operation.

After replace filler plate & end cap.

• Putting zip tie through cable tie mount.

Secure wires & clip off excess tie.

• While push pad is depressed check to

make sure motor block is activating

switch.

• Run wires down along the side of motor.

• Place sticky side of the cable tie mount

onto the inside of the baserail.

Page 4: SAA SUCS - Command Access€¦ · SAA SUCS Visit our website for more details U.S. Customer Support 1-888-622-2377 Canada Customer Support 1-855-823-3002 The SGTREXKIT-M-ED is a field

SGTREXKIT-M-ED

Doc # 20082_A

Visit our website for more detailswww.CommandAccess.com

U.S. Customer Support1-888-622-2377

Canada Customer Support1-855-823-3002

T E C H N I C A L I N F O R M A T I O N

Troubleshooting & Diagnostics

Specifications• Rating:

• Configuration:

5A @120VAC

Green - Common (C)

Blue - Normally Open (NO)

Gray - Normally Closed (NC)

If switch does not trigger correctly. Check activating lever arm on switch & re-adjust to make

sure it is making good contact with motor block when it moves forward.