elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | Å +49 (0) 75 61 97 00 Æ +49 (0) 75 61 97 01 00 | www.elobau.com Technical data and content subject to change without notice. Page 1 of 8 471 EFR... - Ver. 1.3 ® The controller unit evaluates the signals of machine safety applications in machines and plants. With the arbitrarily configurable structure, the inputs can be used for a wide range of functions, for example as protective door monitoring, emergency stop, or to connect light curtains. A 2-hand control can also be implemented. + SIL 2 or 3 (EN IEC 61508) SIL CL 2 or 3 (EN IEC 62061), PL d or e (EN ISO 13849-1) and ETL approval + for sensors with 2 N.O. contacts and also suitable for N.O./N.C. contacts + sensor inputs also suitable for OSSD (Output Signal Switching Device) (e.g. light curtains) + up to four independently switching safety outputs + time and cost savings through pre-configured and validated units, which also facilitates easy integration + unique identification of the configuration via permanently assigned part number + emergency stop function Use Options Safety controller unit eloFlex 471EFR... flexible configuration of the inputs and outputs The internal logic combination of the safety inputs and outputs with AND, OR, NAND, NOR, XOR, XNOR permits a high adaptability to the application. The safety outputs can be switched on and off with a delay of 0.1 to 99.9 s (resolution 0.1 s). Motor contactor auxiliary contacts or an additional start button can be used for external monitoring. The control outputs of the eloFlex unit can also be configured. The SIL CL 3 / PL e option can be offered at very reasonable cost due to the number of the safety outputs. PI_471EFR_Auswerteeinheit_Endversion_1_3_EN.indd 1 30.03.11 13:56

Upload: others

Post on 23-Jul-2020

17 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Safety controller unit - Tritecnica · Connection terminal 0.2 - 2.5 mm² Double terminal (optional) 0.2 - 1.5 mm² Screw terminal (optional) 0.2 - 2.5 mm² The pluggable terminals

elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | Å +49 (0) 75 61 97 00 Æ +49 (0) 75 61 97 01 00 | www.elobau.com

Technical data and content subject to change without notice.

Page 1 of 8471 EFR... - Ver. 1.3

®

The controller unit evaluates the signals of machine safety applications in machines and plants.

With the arbitrarily configurable structure, the inputs can be used for a wide range of functions,

for example as protective door monitoring, emergency stop, or to connect light curtains. A 2-hand

control can also be implemented.

+ SIL 2 or 3 (EN IEC 61508) SILCL 2 or 3 (EN IEC 62061), PL d or e (EN ISO 13849-1) and ETL approval

+ for sensors with 2 N.O. contacts and also suitable for N.O./N.C. contacts

+ sensor inputs also suitable for OSSD (Output Signal Switching Device) (e.g. light curtains)

+ up to four independently switching safety outputs

+ time and cost savings through pre-configured and validated units, which also facilitates easy integration

+ unique identification of the configuration via permanently assigned part number + emergency stop function

Use

Options

Safety controller unit eloFlex 471EFR... flexible configuration of the inputs and outputs

The internal logic combination of the safety inputs and outputs with AND, OR, NAND, NOR, XOR,

XNOR permits a high adaptability to the application. The safety outputs can be switched on and off

with a delay of 0.1 to 99.9 s (resolution 0.1 s). Motor contactor auxiliary contacts or an additional

start button can be used for external monitoring. The control outputs of the eloFlex unit can also

be configured. The SILCL 3 / PL e option can be offered at very reasonable cost due to the number

of the safety outputs.

PI_471EFR_Auswerteeinheit_Endversion_1_3_EN.indd 1 30.03.11 13:56

Page 2: Safety controller unit - Tritecnica · Connection terminal 0.2 - 2.5 mm² Double terminal (optional) 0.2 - 1.5 mm² Screw terminal (optional) 0.2 - 2.5 mm² The pluggable terminals

elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | Å +49 (0) 75 61 97 00 Æ +49 (0) 75 61 97 01 00 | www.elobau.com

Technical data and content subject to change without notice.

Page 2 of 8471 EFR... - Ver. 1.3

®

Mechanical assembly

Installation dimensions

Key mechanical data

Housing 120 x 100 x 45 mm (without terminals)

120 x 130 x 45 mm (with terminals)

Installation on DIN rail TH35 acc. to DIN EN 60715

Technology confi gurable safety controller unit

Material PA (polyamide), PC (polycarbonate)

Weight up to about 400 g (depending on the version)

Working temperature range 0°C to +55°C (+32°F to 131°F)

Storage temperature range -25°C to +85°C (-13°F to +185°F)

Protection class IP30 DIN EN 60529

Color black

Sensors 2-hand control

Operating time 3 s 0.5 s

PI_471EFR_Auswerteeinheit_Endversion_1_3_EN.indd 2 30.03.11 13:56

Page 3: Safety controller unit - Tritecnica · Connection terminal 0.2 - 2.5 mm² Double terminal (optional) 0.2 - 1.5 mm² Screw terminal (optional) 0.2 - 2.5 mm² The pluggable terminals

elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | Å +49 (0) 75 61 97 00 Æ +49 (0) 75 61 97 01 00 | www.elobau.com

Technical data and content subject to change without notice.

Page 3 of 8471 EFR... - Ver. 1.3

®

Key electrical data

Approvals and safety-relevant technical specifications

Safety-relevant technical specifications SIL 2 or 3 (EN IEC 61508)

SILCL 2 or 3 (EN IEC 62061)

PL d or e (EN ISO 13849-1)

category 3 or 4 (EN 954-1 / EN ISO 13849-1)

Operating life 20 years

Approvals ETL CAN/ESA C22.2#14, ANSI/UL 508

Operating voltage 24 V DC ±10%

Current consumption max. 400 mA

Status indication 10x LED

Safety outputs (1-4) Control outputs (1-4)

Switching voltage 30 V DC / 250 V AC 24 V DC

Switching current 3 A AC/DC 100 mA

Switching power 90 W / 750 VA 2.4 W

Wiring

Input Logic Output

&

≥ 1

= 1

13

15

16

12

9

10

25

1

26

2

27

3

28

4

19

20

eloFlex

K3 K4

K1 +

-

14

(-)

(+)

(-)

(+)

(-)

(+)

(-)

(+)

K2

5

7

8

6

21

23

24

22

29

31

32

30

Sensor1

Sensor2

Sensor3

Sensor4

Power UB

Fault

Safety 4

Safety 1

24 V DC

K3 K4

Control Sensor 1

Control Sensor 2

Control Sensor 3

Control Sensor 4

+UB

PLC

11K1 K2

external contactor /

Start 1

external contactor /

Start 2

Schaltbilddarstellung in spannungslosem Zustand. Sensor nicht betätigt.

Ready

18

17

Safety 2

Safety 3

Diagram of circuit in not energised condition.Sensor is not activated.

PI_471EFR_Auswerteeinheit_Endversion_1_3_EN.indd 3 30.03.11 13:56

Page 4: Safety controller unit - Tritecnica · Connection terminal 0.2 - 2.5 mm² Double terminal (optional) 0.2 - 1.5 mm² Screw terminal (optional) 0.2 - 2.5 mm² The pluggable terminals

elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | Å +49 (0) 75 61 97 00 Æ +49 (0) 75 61 97 01 00 | www.elobau.com

Technical data and content subject to change without notice.

Page 4 of 8471 EFR... - Ver. 1.3

®

Connection type

Connection terminals

Sensor input 1 - sensors with 2 normally open contacts- sensors with normally open/normally closed contacts- emergency stop button- 2-hand control- light curtain (OSSD)- electronic sensors (PNP outputs)

Sensor input 2

Sensor input 3

Sensor input 4

Connection terminal 0.2 - 2.5 mm²

Double terminal (optional) 0.2 - 1.5 mm²

Screw terminal (optional) 0.2 - 2.5 mm²

The pluggable terminals can be coded via pins. Optional double or screw terminals are also available.

Illustration with double terminal

* Automatic: connect control contact from the external contactor or bridge the input Manual: release on leading edge Monitored: release on trailing edge

Connection terminals

- dependent on the logic operation, switching from sensor input 1 - 4

- switch-on/switch-off delays

Safety output 1

Safety output 2

Safety output 3

Safety output 4

External contactor (automatic*) or start button (manual or monitored*)

External contactor 1 + 2

Supply voltage Power UB

Connection terminals

Control output 1 - dependent on the logic operation, switching from sensor input 1 - 4

- switch-on/switch-off delays- BTR / error: no input assignment possible if this function is used

Control output 2

Control output 3

Control output 4

PI_471EFR_Auswerteeinheit_Endversion_1_3_EN.indd 4 30.03.11 13:56

Page 5: Safety controller unit - Tritecnica · Connection terminal 0.2 - 2.5 mm² Double terminal (optional) 0.2 - 1.5 mm² Screw terminal (optional) 0.2 - 2.5 mm² The pluggable terminals

elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | Å +49 (0) 75 61 97 00 Æ +49 (0) 75 61 97 01 00 | www.elobau.com

Technical data and content subject to change without notice.

Page 5 of 8471 EFR... - Ver. 1.3

The input/output state can be determined from the following LEDs.

LED 1 readiness for operation LED 6 sensor 4

LED 2 error LED 7 safety output 1

LED 3 sensor 1 LED 8 safety output 2

LED 4 sensor 2 LED 9 safety output 3

LED 5 sensor 3 LED 10 safety output 4

®

LED distribution

Four safety sensors can be connected directly to the safety control unit. When using the following elobau interfaces, the monitoring can be extended to up to 32 safety sensors. Please take note that when using interfaces, the SILCL or PL level is reduced in some applications. Contact elobau for assistance in making the proper selection:

363V98/363098 363V97/363096K30

Extensions

PI_471EFR_Auswerteeinheit_Endversion_1_3_EN.indd 5 30.03.11 13:56

Page 6: Safety controller unit - Tritecnica · Connection terminal 0.2 - 2.5 mm² Double terminal (optional) 0.2 - 1.5 mm² Screw terminal (optional) 0.2 - 2.5 mm² The pluggable terminals

elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | Å +49 (0) 75 61 97 00 Æ +49 (0) 75 61 97 01 00 | www.elobau.com

Technical data and content subject to change without notice.

Page 6 of 8471 EFR... - Ver. 1.3

®

Specification

To configure the eloFlex system, connect the individual building blocks and check the appropriate logic box below. If you want to implement a switch-on and/or switch-off delay, please specify this (0...99.9s - resolution 0.1s):

Safety output 1

Input LogicSwitch-on/switch-off delay in s

External monitoring

safety input 1

AND

tON

, s

-tOFF

, s

contactor / start 1

safety input 2

ORcontactor / start 2

safety input 3

NAND

safety input 4

NOR

XOR

XNOR

NOT

2-hand control 1 + 2

2-hand control 3 + 4

Safety output 2

Input LogicSwitch-on/switch-off delay in s

External monitoring

safety input 1

AND

tON

, s

-tOFF

, s

contactor / start 1

safety input 2

ORcontactor / start 2

safety input 3

NAND

safety input 4

NOR

XOR

XNOR

NOT

2-hand control 1 + 2

2-hand control 3 + 4

Safety output 3

Input LogicSwitch-on/switch-off delay in s

External monitoring

safety input 1

AND

tON

, s

-tOFF

, s

contactor / start 1

safety input 2

ORcontactor / start 2

safety input 3

NAND

safety input 4

NOR

XOR

XNOR

NOT

2-hand control 1 + 2

2-hand control 3 + 4

Safety output 4

Input LogicSwitch-on/switch-off delay in s

External monitoring

safety input 1

AND

tON

, s

-tOFF

, s

contactor / start 1

safety input 2

ORcontactor / start 2

safety input 3

NAND

safety input 4

NOR

XOR

XNOR

NOT

2-hand control 1 + 2

2-hand control 3 + 4

Safety input 1

N.O./N.O.

N.O./N.C.

N.C./N.C.

OSSD

Safety input 2

N.O./N.O.

N.O./N.C.

N.C./N.C.

OSSD

2-hand control (operating time 0.5 s)

Safety input 3

N.O./N.O.

N.O./N.C.

N.C./N.C.

OSSD

Safety input 4

N.O./N.O.

N.O./N.C.

N.C./N.C.

OSSD

2-hand control (operating time 0.5 s)

External contactor 1

automatic

manual

monitored

External contactor 2

automatic

manual

monitored

Fax: +49 (0) 7561 970 100

E-mail: [email protected]

PI_471EFR_Auswerteeinheit_Endversion_1_3_EN.indd 6 30.03.11 13:56

Page 7: Safety controller unit - Tritecnica · Connection terminal 0.2 - 2.5 mm² Double terminal (optional) 0.2 - 1.5 mm² Screw terminal (optional) 0.2 - 2.5 mm² The pluggable terminals

elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | Å +49 (0) 75 61 97 00 Æ +49 (0) 75 61 97 01 00 | www.elobau.com

Technical data and content subject to change without notice.

Page 7 of 8471 EFR... - Ver. 1.3

®

Remarks:Safety inputs:N.O./N.O. or N.O./N.C. = e.g. protective doorN.C./N.C. = e.g. emergency stop buttonOSSD = e.g. light curtain with two PNP outputs

External contactor:Only one external contactor monitoring can be assigned to each safety outputautomatic = elobau standardmanual = release on leading edgemonitored = release on trailing edge

Safety and control outputs:An input assignment is impossible only when BTR, Error or safety output are selected. Only one logic per control output and safety output possible!

Specification Control output 1

Input LogicSwitch-on/

switch-off delay in s

safety input 1

AND

tON

, s

-tOFF

, s

safety input 2

OR

safety input 3

NAND

safety input 4

NOR

XOR

XNOR

NOT

BTR

ERROR

as safety output 1

as safety output 2

as safety output 3

as safety output 4

Control output 2

Input LogicSwitch-on/

switch-off delay in s

safety input 1

AND

tON

, s

-tOFF

, s

safety input 2

OR

safety input 3

NAND

safety input 4

NOR

XOR

XNOR

NOT

BTR

ERROR

as safety output 1

as safety output 2

as safety output 3

as safety output 4

Control output 3

Input LogicSwitch-on/

switch-off delay in s

safety input 1

AND

tON

, s

-tOFF

, s

safety input 2

OR

safety input 3

NAND

safety input 4

NOR

XOR

XNOR

NOT

BTR

ERROR

as safety output 1

as safety output 2

as safety output 3

as safety output 4

Control output 4

Input LogicSwitch-on/

switch-off delay in s

safety input 1

AND

tON

, s

-tOFF

, s

safety input 2

OR

safety input 3

NAND

safety input 4

NOR

XOR

XNOR

NOT

BTR

ERROR

as safety output 1

as safety output 2

as safety output 3

as safety output 4

Fax: +49 (0) 7561 970 100

E-mail: [email protected]

PI_471EFR_Auswerteeinheit_Endversion_1_3_EN.indd 7 30.03.11 13:56

Page 8: Safety controller unit - Tritecnica · Connection terminal 0.2 - 2.5 mm² Double terminal (optional) 0.2 - 1.5 mm² Screw terminal (optional) 0.2 - 2.5 mm² The pluggable terminals

elobau GmbH & CO. KG | Zeppelinstr. 44 | 88299 Leutkirch | Germany | Å +49 (0) 75 61 97 00 Æ +49 (0) 75 61 97 01 00 | www.elobau.com

Technical data and content subject to change without notice.

Page 8 of 8471 EFR... - Ver. 1.3

®

Name/fi rst name _________________________________________________________________

Company _________________________________________________________________

Address _________________________________________________________________

Postal code/town _________________________________________________________________

Country _________________________________________________________________

Å _________________________________________________________________

Æ _________________________________________________________________

E-mail _________________________________________________________________

Notes, questions, other

Your product enquiry

Quantity ____________________ Batch size ___________________

Fax: +49 (0) 7561 970 100

E-mail: [email protected]

PI_471EFR_Auswerteeinheit_Endversion_1_3_EN.indd 8 30.03.11 13:56