Page 1: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING
Page 2: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

i

SAFETY INSTRUCTIONS

WARNING

Wear a safety belt and hardhat when working on the scanner unit.

Serious injury or death canresult if someone falls fromthe radar scanner mast.

Turn off the power at the mains switch-board before beginning the installation.

Fire, electrical shock or serious injury canresult if the power is left on or is appliedwhile the equipment is being installed.

Do not open the equipmentunless totally familiar withelectrical circuits andservice manual.

Only qualified personnel should work inside the equipment.

WARNING

Radiatortype

Distance to10 W/mpoint

2

Distance to100 W/m

point

2

XN12A(4')

XN13A(6')

Nil

1.2 m

1.1 m

Radio FrequencyRadiation Hazard

The radar scanner emits electromagneticradio frequency (RF) energy which can beharmful, particularly to your eyes. Neverlook directly into the scanner aperture froma close distance while the radar is inoperation or expose yourself to the trans-mitting scanner at a close distance.

Distances at which RF radiation levels of100 and 10 W/m exist are given in thetable below.

Note: If the scanner unit is installed at aclose distance in front of the wheel house, your administration may require halt oftransmission within a certain sector ofscanner revolution. This is possible - Askyour FURUNO representative or dealer toprovide this feature.

2

ELECTRICALSHOCK

HAZARD

Construct a suitable service platformfrom which to install the scanner unit.

Serious injury or death can result if some-one falls from the radar scanner mast.

Do not install the display unit where itmay get wet from rain or water splash.

Water in the display unit can result in fire,electrical shock or equipment damage.

Page 3: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

ii

CAUTION

Observe the following compass safedistances to prevent deviation of amagnetic compass:

Ground the equipment toprevent electrical shock andmutual interference.

Displayunit

Scannerunit

Standard Steering

1.10 m 0.80 m

1.00 m 0.75 m

HIGH TENSION WARNING

WARNINGBe sure that the power supply iscompatible with the voltage rating ofthe equipment.

Connection of an incorrect power supplycan cause fire or equipment damage. Thevoltage rating of the equipment appearson the label above the power connector.

Use only the specified power cable.

Fire or equipment damage can result if adifferent cable is used.

DANGERElectrical shock hazard.Do not touch parts in -side this cover.

Name: Warning Label Type: 14-055-4202-1Code No.: 100-245-221

Page 4: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

iii

TABLE OF CONTENTS

EQUIPMENT LISTS ..................................................................................................... ivSYSTEM CONFIGURATION ................................................................................... vi

SCANNER UNITMounting Considerations, Precautions ..................................................................................... 1Mounting Methods ................................................................................................................... 1Fixing Holes in Mounting Platform.......................................................................................... 1Fastening the Radiator to the Radiator Bracket ........................................................................ 2Mounting the Scanner Unit ....................................................................................................... 2Outside fixing holes .................................................................................................................. 2Fixing holes inside scanner unit ............................................................................................... 3Connecting the Signal Cable .................................................................................................... 4

DISPLAY UNITMounting Considerations ......................................................................................................... 6Tabletop Mounting.................................................................................................................... 6Bulkhead, Overhead Mounting................................................................................................. 7

WIRING ............................................................................................................................... 8

ADJUSTMENTS, INITIAL SETTINGSAdjustments, Initial Settings

1. Displaying the Installation Setup menu............................................................................. 92. Selecting a navaid .............................................................................................................. 93. Selecting a heading sensor................................................................................................. 94. Adjusting tuning, video amplifier input level .................................................................... 95. Aligning heading ............................................................................................................. 106. Adjusting sweep timing ................................................................................................... 107. Adjusting MBS (Main Bang Suppression) ...................................................................... 118. Entering scanner height ................................................................................................... 119. Selecting STC curve ........................................................................................................ 1110. Setting a dead sector ...................................................................................................... 1211. Checking magnetron heater voltage .............................................................................. 12

ARP-10 INSTALLATIONNecessary Parts ....................................................................................................................... 13Installation .............................................................................................................................. 13Adjustments ............................................................................................................................ 14

INSTALLATION MATERIALS, ACCESSORIES, SPARE PARTS ......A-1OUTLINE DRAWINGS ..............................................................................................D-1INTERCONNECTION DIAGRAM ........................................................................ S-1

Page 5: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

iv

EQUIPMENT LISTS

Standard Supply

emaN epyT .oNedoC ytQ skrameR

rennacStinU

950-0700-BSR-A21NX -

1

mm0521,mpr42

950-0700-BSR-A21NX - mm0081,mpr42

950-0700-BSR-A21NX - mm0521,mpr84

tinUyalpsiD 221-PDR - 1

straPerapS 00201-30PS 296-580-000 1 tsilgnikcapeeS

noitallatsnIslairetaM

00481-30PC 298-680-000

1

,10481-30PC,elbacrewoP

elbaclangism01

See

packing

lists

01481-30PC 398-680-000,10481-30PC,elbacrewoP

elbaclangism51

02481-30PC 498-680-000,10481-30PC,elbacrewoP

elbaclangism02

03481-30PC 598-680-000,10481-30PC,elbacrewoP

elbaclangism03

straPerapS 01350-30PF 757-580-000 1

01920-30PF

01340-30PF

02920-30PF

Page 6: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

v

Optional Supply

emaN epyT .oNedoC skrameR

rezzuBlanretxE 12-30PO 790-030-000

reifitceR 3243-UR 344-030-000

.yssAelbaC

001-7000FPS6A-JM 732-521-000 P6/wm01,rosnesgnidaehroFthgiarts,sdnehtobtarotcennoc

050-2100FPS6A-JM 424-431-000m5,rednuosoediv,diavanroF

,sdnehtobtarotcennocP6/wssorc

001-2100FPS6A-JM 718-331-00001,rednuosoediv,diavanroF

htobtarotcennocP6/wmssorc,sdne

001-9000FPS6A-JM 632-521-000,rednuosoediv,diavanroFP6/wm01,rosnesgnidaeh

dneenotarotcennoc

elbaClangiS 050-3000FPS6A-JM 306-711-000 enonorotcennocP6/w,m5dne

retliFIME 00550-30PF 099-654-800

revoCtsuD 1009-830-30 628-108-000

sneL/wdooH 021-30PO 088-144-800

retliF 02920-30PF 067-422-800

rettolPotuA 01-PRA 258-680-000 rennacsmpr42htiwelbaesUtinu

rettolPradaR 011-PR -

yalpsiDevalS118-DMF - DCL

0108-DMF -

yalpsiDetomeR 0081-DMF - retrevnoCDVC/w

.yssAelbaC 500-6000FPL42B-JM 834-041-000 rotcennocretrevnocelbaC

Page 7: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

vi

SYSTEM CONFIGURATION

Signal Cable MJ-B24LPF0005(10 m, 15 m, 20 m,30 m, 10 m standard)

DISPLAY UNITRDP-122

Gyro Converter

AD-100Gyrocompass

Video SounderIEC 1162*

NavigatorIEC 1162*

RectifierRU-3423

12/24/32 VDC

ExternalBuzzer

OP03-21

Auto PlotterARP-10

03S9235-1

Broken lines denote optional equipment.* Equivalent to NMEA 0183

SCANNER UNITXN12A-RSB-0070-059 XN13A-RSB-0070-059XN12A-RSB-0073-059

(built indisplay unit)

Heading SensorC-2000

PG-2000IEC 1162*

Slave DisplayFMD-811

FMD-8010

Radar PlotterRP-110

100/110/115/220/230 VAC, 1∅, 50/60 Hz

Remote DisplayFMD-1800

CVD ConverterRP-6065B

Page 8: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

1

SCANNER UNIT

Mounting Considerations,Precautions

• The scanner unit is generally installed ei-ther on top of the wheelhouse or on the ra-dar mast on a suitable platform. Locate thescanner unit where there is a good all-roundview. Any obstruction will cause shadowand blind sectors. A mast for instance, witha diameter considerably less than the widthof the radiator, will cause only a small blindsector, but a horizontal spreader orcrosstrees in the same horizontal plane asthe scanner unit would be a much moreserious obstruction; you would need toplace the scanner unit well above or belowit.

• It is rarely possible to place the scanner unitwhere a completely clear view in all direc-tions is available. Thus, you should deter-mine the angular width and relative bearingof any shadow sectors for their influenceon the radar at the first opportunity afterfitting.

• If you have a radio direction finder on yourboat, locate its scanner clear of the scan-ner unit to prevent interference to the di-rection finder. A separation of more thantwo meters is recommended.

• To lessen the chance of picking up electri-cal interference, avoid where possible rout-ing the signal cable near other onboardelectrical equipment. Also avoid runningthe cable in parallel with power cables.

• A magnetic compass will be affected ifplaced too close to the scanner unit. Ob-serve the following compass safe distancesto prevent deviation of a magnetic com-pass: Standard compass, 1.00 m, Steeringcompass, 0.75 m.

• Do not paint the radiator aperture, to en-sure proper emission of the radar waves.

• When this radar is to be installed on largervessels, consider the following points:

• The signal cable run between the scan-ner and the display comes in lengths of10 m (standard), 15 m, 20 m and 30 m.Whatever length is used it must be un-broken; namely, no splicing allowed.

• Deposits and fumes from a funnel orother exhaust vent can adversely affectthe aerial performance and hot gasesmay distort the radiator portion. Thescanner unit must not be mounted wherethe temperature is more than 70°C.

Mounting Methods

As shown in the figure below, the scanner unitmay be installed on the bridge, on a commonmast or on a dedicated mast.

(a) On bridge (b) Common mast (c) Dedicated mast

Figure 1 Scanner unit mounting methods

Fixing Holes in MountingPlatform

Referring to the outline drawing on page D-1, drill five holes in the mounting platform:four holes of 15 mm diameter for fixing thescanner unit and one hole of 25-30 mm diam-eter for the signal cable.

Page 9: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

2

Fastening the Radiator to theRadiator Bracket

For your reference, scanner installation ma-terials list appears on page A-8.

1. Remove the radiator cap from the radiatorbracket.

2. Coat contacting surface between scannerradiator and radiator bracket with anticor-rosive sealant as shown below.

RADIATOR BRACKET(top view)

Coat hatched area withanticorrosive sealant.

10mm

Figure 2 Coating scanner bracket withanticorrosive sealant

3. Coat threaded holes on the scanner radia-tor with anticorrosive sealant.

4. Grease the O-ring and set it to the radiatorbracket.

5. Lay the scanner radiator on the radiatorbracket.

6. Coat the radiator fixing bolts (4 pcs.) withanticorrosive sealant. Fasten the scannerradiator to the radiator bracket with theradiator fixing bolts, flat washers andspring washers.

Flat washerSpring washerHex head bolt(M8 x 30)

Radiator bracket

Coat bolts withanticorrosivesealant.

Scannerradiator

O-ring

Coat threadedholes with anti-corrosivesealant.

Figure 3 Fastening the radiator bracket tothe scanner unit chassis

Mounting the Scanner Unit

The scanner unit can be mounted using thefixing holes on the outside (200 x 200 mm)or inside (140 x 150 mm) the scanner unit.

Ship's Bow Ship's Bow

Figure 4 Mounting of Scanner Unit

Outside fixing holes

Use the hex. bolt (supplied) to mount the scan-ner unit as below.

1. Lay the corrosion-proof rubber mat (sup-plied) on the mounting platform.

Groundterminal

Rubbermat

Bow mark

Figure 5 Location of rubber mat

2. Lay the scanner unit on the mounting plat-form, orienting it as shown in Figure 6.

STERN

BOW

Figure 6 Scanner unit

Page 10: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

3

CAUTIONDo not lift the antenna unit by theradiator; lift it by the housing.

The radiator may be damaged.

3. Insert four hex bolts and seal washers fromthe top of the scanner housing. Insert theseal washers with the larger diameter nextto the bolt heads. Be sure the seal washer,not other washers, is next to bolt head.

Hex bolt

Seal washer

Flat washerSpring washer

Nut

Figure 7 Fixing the scanner unit chassis

4. Pass flat washers, spring washers and nutsonto hex bolts. Fasten by tightening nuts.Do not fasten by tightening the hex bolts;seal washers may be damaged.

ScannerunitMountingplatform

Siliconesealant

Flat washer

Rubber mat

Seal washer

Figure 8 How to fasten scanner unit tomounting platform

5. Coat flat washers, spring washers, nuts andexposed parts of bolts with silicone seal-ant.

6. Prepare ground point in mounting platform(within 300 mm of ground terminal onscannere unit) using M6 x 25 bolt, nut andflat washer.

7. Run the ground wire (RW-4747, 340 mm)between the ground terminal and groundpoint.

8. Coat ground terminal and ground pointwith silicone sealant as shown in Figure9.

Groundterminal

Hex boltFlat washer

Spring washerFlat washer

Hex nutSiliconesealant

Hex nut

Weld here.

Siliconesealant

Groundwire

Scannerunit

OR

Flat washerSpring washer

Groundwire

GROUNDTERMINAL

GROUNDPOINT

Hex nut

Figure 9 How to coat ground point andground terminal with silicone sealant

Fixing holes inside scannerunit

This method requires removal of the RF unitin the scanner unit to access inside fixingholes. Use hex. bolts, flat washers, springwashers and nuts (local supply) to mount thescanner unit, confirming length of bolts.

Page 11: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

4

1. Loosen four scanner bolts to open thescanner unit.Refer to Figure 11 for location.

RF unit

Hex. boltM10X20 SUS4 pcs.

Hex. boltM8X25 SUS 2 pcs.

Spring WasherM10 SUS 4 pcs.

Cover

Pan head screwM3X8 4 pcs.

Upper chassis

Square bushing

Lower chassis

Figure 10 Scanner unit chassis, upperchassis separated

2. Unplug connector connected between up-per and lower chassis.

3. Separate upper chassis from lower chas-sis by removing two hex. bolts.

4. Remove cover by unfastening four panhead screws.

5. Remove connector from RF unit.

6. Remove RF unit by unfastening four hex.bolts.

7. Lay the corrosion-proof rubber mat (sup-plied) on the mounting platform.

8. Fasten the lower chassis to the mountingplatform with hex. bolts, spring washers,flat washers and nuts (local supply), andthen coat flat washers, spring washers, nutsand exposed parts of bolts with siliconesealant.

Cut a slit in rubber bushing to insert bolts.Seal washers are not required.

9. Reassemble RF unit, cover and upperchassis.

10.Set four knob caps (supplied) into outsidefixing holes.

11. Do steps 6-8 in “Outside fixing holes”.

Connecting the Signal Cable

Only the signal cable runs from the displayunit to the scanner unit. In order to minimizethe chance of picking up electrical interfer-ence, avoid where possible routing the signalcable near other onboard electrical equipment.Also, avoid running the cable in parallel withpower cables. Pass the cable through the holeand apply sealing compound around the holefor waterproofing.

1. Open the scanner cover by loosening fourscanner bolts, and then fix the stay.

Stay

Cable gland

ScannerBolt

Figure 11 Scanner unit chassis,cover opened

2. Fabricate the signal cable as shown below.

About210 mm

Tubing

Vinylsheath

About 370 mm

Figure 12 Fabrication of signal cable

3. Unfasten the cable gland assembly (plate,gasket, flat washer).

4. Pass the signal cable w/connector throughthe bottom of the scanner unit chassis. Passthe cable through the gland assembly asshown below.

Page 12: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

5

Plate

Bolt

4-M4 X 16

Gasket

Flatwasher

Figure 13 Passing the signal cable throughthe cable gland assembly

5. Fasten the crimp-on lug on the shield toone of the fixing bolts of the cable glandassembly.

6. Position the signal cable so that no morethan 4 cm of the sheath is exposed asshown in the figure below. Tighten fixingbolts.

Sheath

CABLE GLAND

Plate

GasketFlatwasher

BoltWithin 4 cm

Tubing

Shield

Figure 14 How to fix signalcable in cable gland

7. Unfasten four screws shown in the figurebelow.

Four screws

Figure 15 Scanner unit chassis,cover opened

8. Pass the signal cable through the cableprotector.

Cableprotector

Figure 16 Scanner unit chassis,cover opened

9. Connect the signal cable to the RTB Board(03P9249), referring to the interconnectiondiagram and the figure below.

10.Attach three EMI cores to the signal cableas shown below.

Route cable along here.

Lead incable here.

J821 VH9P

J824 NH13P

J823 VH4P

EMI coreRFC-13

Clamp

Figure 17 Scanner unit chassis,cover opened

11. Fix the signal cable with the cable clamp.

12.Release the stay and close the cover.Loosely fasten the cover fixing screws;you will have to make some adjustmentsinside after completion of wiring.

Note: When closing the cover, set the gasketsto grooves in the bottom chassis, then tightenbolts.

BOTTOM CHASSIS

GASKET

GROOVE

SCANNER BOLT

Torque : 9.8 ± 0.1N m

Page 13: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

6

DISPLAY UNIT

Mounting Considerations

The display unit can be mounted on a table-top, a bulkhead or on the overhead. When se-lecting a mounting location, keep in mind thefollowing points:

• Select a location where the display unit canbe viewed and operated conveniently andwhere the screen can be viewed while fac-ing towards the bow.

• Locate the equipment away from placessubject to water splash and rain.

• The display unit weighs 13 kg. Be sure themounting location is strong enough to sup-port the weight of the unit under the con-tinued vibration which is normallyexperienced on the ship. If necessary rein-force the mounting location.

• Leave sufficient space on the sides and rearof the unit to facilitate maintenance. Also,leave a foot or so of “service loop” in cablesbehind the unit so it can be pulled forwardfor servicing or easy removal of connec-tors.

• A magnetic compass will be affected ifplaced too close to the display unit. Ob-serve the following compass safe distancesto prevent deviation of a magnetic com-pass: Standard compass, 1.0 m, Steeringcompass, 0.8 m.

Tabletop Mounting

1. Unfasten the two bolts at the front of thedisplay unit to dismount the mountingbase.

2. Using the mounting base as a templatemark fixing holes in the mounting loca-tion.

3. Fasten the mounting base to the tabletopwith M10 bolts or coach screws.

4. Set the display unit to the mounting baseand fasten it with the bolts removed at step1.

120

100160

DISPLAYUNIT

M10 boltsor coachscrewsM8 x 40 hex bolt

Cap

Mounting base

Figure 17 Tabletop mounting ofdisplay unit

Page 14: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

7

Bulkhead, Overhead Mounting

The display unit is shipped ready for mounting on a tabletop. However, it may also be mountedon a bulkhead or on the overhead, following the illustration below.

M10 hex bolt,spring washer,flat washer

M6 x 16 hexbolts (4 pcs.)

DISPLAYUNIT

M4 x 10cosmetic screws(4 pcs.)

Cover

Mountingbase

Fixingplate

M8 x 40 hex bolt (2 pcs.)

Figure 18 Bulkhead, overhead mounting

Page 15: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

8

WIRING

All wiring are terminated at the rear of the display unit. Connect the scanner unit, power supplyand external equipment, referring to the drawing below for connector location. Be sure to groundthe display unit.

CAUTIONUse the power cable supplied with theradar.

Ground the equipment toprevent electrical shock andmutual interference.

External equipment connector(Slave display, Remote display)

DJ connector(Scanner)

Gyrocompassconnector

NMEA I/O connector(Navigator, see below)

NMEA connector(Video Sounder,see below)

Earth terminal Powerconnector Power fuse F1351*

10A: 24/32 VDC15A: 12 VDC

* The display unit is shippedfor connection to a 12 Vship’s mains, and a 15A fuseis inserted in the fuse holder.For 24/32 V ship’s mains, re-place the 15A fuse with the10A fuse (supplied).

INT Board SPU Board

Navigator(Plotter)

(RSD, TLL)

(L/L, WP...)

Depth, watertemperature

VideoSounder

Figure 19 Display unit, rear view

Page 16: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

9

ADJUSTMENTS, INITIAL SETTINGS

Adjustments, Initial Settings1. Displaying the Installation Setup menu

Most adjustments and initial settings may becompleted on the Installation Setup menu, andyou can display this menu as follows:

1. Press the HM OFF control while turningon the power. Release the control whenyou hear a beep.

2. Press the [MENU] key. The MAIN menuappears.

SSel by T-ball & press ENT.S

RINGS INDEX LINE

DISP DATA

ARP-10MENU

Change brillfrom 3 to max.

INTREJECT

OTHERSMENU

Figure 20 Main menu

3. Select OTHERS menu with the trackballand press the [ACQ/ENTER] key.

4. Select 23. Installation Setup menu with thetrackball and press the [ACQ/ENTER]key.

Low Mid Hig

GPSfa˚FGyroOnStop

Std

Slave

Allm˚CMagnetOffRotate180˚~180˚

Sharp

Master000001.5H000000.0H

Gntl

LCft

[Installation Setup]Select item by T-balland press ENT key.

1. Nav Talker 2. Depth Unit 3. Temp Unit 4. Hdg Sensor 5. Key Beep 6. Ant on Tx 7. Dead Sector 8. Tune/Video Auto Adjustment 9. Heading Alignment10. Sweep Timing Adjustment 11. MBS Adjustment12. Ant Height13. STC Curve14. Oper Mode15. Hours in Use16. Tx Hours

Figure 21 Installation Setup menu

5. Select menu item with the trackball andpress the [ACQ/ENTER] key.

6. Select menu option with the trackball andpress the [ACQ/ENTER] key to register.

2. Selecting a navaid

1. Select 1. Nav Talker on the InstallationSetup menu and press the [ACQ/ENTER]key.

2. Select type of navaid connected to the ra-dar; All, GPS or LC (Loran C). “All” dis-plays GPS and Loran C position dataalternately.

3. Press the [ACQ/ENTER] key.

3. Selecting a heading sensor

1. Select 4. Hdg Sensor on the InstallationSetup menu and press the [ACQ/ENTER]key.

2. Select type of heading sensor connectedto the radar; magnetic compass (for ex-ample, C-2000, PG-1000) or gyrocompass(requires AD-10 Gyro Converter).

3. Press the [ACQ/ENTER] key.

4. Adjusting tuning, video amplifier input level

Do the following to automatically adjust tun-ing and video amplifier level input.

1. Press the [STBY/TX] key to transmit.

2. Select 8. Tune/Video Adjustment on theInstallation Setup menu and press the[ACQ/ENTER] key. The unit automati-cally adjusts tuning and video amplifierinput level, displaying the following mes-sage:

Page 17: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

10

[Tune/Video Auto Adjustment]

Now under correction.

Return to installation setupmenu after the correction.

Figure 22 Tune/video autoadjustment message

3. When adjustment is completed, the mes-sage disappears.

5. Aligning heading

You have mounted the scanner unit facingstraight ahead in the direction of the bow.Therefore, a small but conspicuous target deadahead visually should appear on the headingmarker (zero degrees).

In practice, you will probably observe somesmall bearing error on the display because ofthe difficulty in achieving accurate initial po-sitioning of the scanner unit. The followingadjustment will compensate for this error.

1. Identify a suitable target (for example, shipor buoy) at a range between 0.125 to 0.25nautical miles, preferably near the head-ing marker. To lessen error, keep echoesin the outer half of the picture by chang-ing the range. Also, be sure the zoom andoff center functions are off.

2. Select 9. Heading Alignment on the Instal-lation Setup menu and press the [ACQ/ENTER] key. The following message ap-pears:

[Heading Alignment]Set EBL1 to center of target

dead ahead and press ENTER.

Correction 0.0°

<Press MENU for inst setup>

Figure 23 Heading alignment message

3. Operate the trackball to bisect target se-lected at step 1 with the heading marker.

4. Press the [ACQ/ENTER] key.

5. As a final test, move the boat towards asmall buoy and confirm that the buoyshows up dead ahead on the radar when itis visually dead ahead.

6. Adjusting sweep timing

This adjustment ensures proper radar perfor-mance, especially on short ranges. The radarmeasures the time required for a transmittedecho to travel to the target and return to thesource. The received echo appears on the dis-play based on this time. Thus, at the instantthe transmitter is fired, the sweep should startfrom the center of the display (sometimescalled sweep origin).

A trigger pulse generated in the display unitgoes to the scanner unit through the signalcable to trigger the transmitter (magnetron).The time taken by the signal to travel up tothe scanner unit varies, depending largely onthe length of the signal cable. During this pe-riod the display unit should wait before start-ing the sweep. When the display unit is notadjusted correctly, the echoes from a straightlocal object (for example, a harbor wall orstraight pier) will not appear with straightedges – they will be seen as “pushed out” or“pulled in” near the picture center. The rangeof objects will also be incorrectly shown.

(1) Correct (2) Target pushedinward

(3) Target pushedoutward

Figure 24 Examples of improper andcorrect sweep timing

1. Transmit on the shortest range and con-firm that the [GAIN] and [A/C SEA] con-trols are properly adjusted.

2. Visually select a target which forms astraight line (for example, harbor wall,straight pier).

3. Select 10. Sweep Timing Adjustment onthe Installation Setup menu and press the[ACQ/ENTER] key. The following mes-sage appears:

Page 18: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

11

[Sweep Timing Adjustment]Use T-ball to straighten

target and press ENTER key.

Correction 0.000 nm

<Press MENU for inst setup>

Figure 25 Sweep timing adjustment message

4. Operate the trackball to straighten the tar-get selected at step 2, and then press the[ACQ/ENTER] key.

7. Adjusting MBS (Main Bang Suppression)

Main bang, a large filled circle which appearsat the display center on short ranges, can besuppressed as follows:

1. Transmit on long range about 10 minutes.

2. Adjust the gain to show a small amount ofnoise on the display.

3. Change to the 0.125 nautical mile rangeand adjust the [A/C SEA] control.

4. Select 11. MBS Adjustment on the Instal-lation Setup menu and press the [ACQ/ENTER] key. The following message ap-pears:

[MBS Adjustment]Set value by T-ball

and press ENTER key.

Correction 000

<Press MENU for inst setup>

Figure 26 MBS adjustment message

5. Operate the trackball to suppress mainbang (adjustment range: 000 to 025).

6. Press the [ACQ/ENTER] key.

8. Entering scanner height

The STC effect changes with respect to scan-ner height above the waterline. Enter scannerheight above the waterline to optimize theSTC effect.

1. Select 12. Ant Height on the InstallationSetup menu and press the [ACQ/ENTER]key.

2. Select scanner height above the waterline;Low (3 m or less), Mid (3 to 6 m) or High(6 to 10 m).

3. Press the [ACQ/ENTER] key.

9. Selecting STC curve

The STC effect changes with respect to thescanner height above the waterline. The de-fault STC curve can be maintained in mostcases. If necessary the STC curve can bechanged as follows:

1. Select 13. STC Curve on the InstallationSetup menu and press the [ACQ/ENTER]key.

2. Select STC curve desired;Sharp: The effective range of the [A/CSEA] control is relatively short.Std: Between Sharp and Gentle.Gntl (Gentle): The effective range ofthe [A/C SEA] control is relatively long.

3. Press the [ACQ/ENTER] key.

Page 19: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

12

10. Setting a dead sector

When the scanner is installed at a close dis-tance in front of the wheelhouse, the radarshould be set not to transmit within that area,to prevent microwave hazard.

1. Select 7. Dead Sector on the InstallationSetup menu and press the [ACQ/ENTER]key.

2. Operate the trackball to enter starting pointof sector (in figures).

3. Press the [ACQ/ENTER] key.

4. Operate the trackball to enter ending pointof sector (in figures).

5. Press the [ACQ/ENTER] key.

Note: The dead sector graphic can be turnedon/off on the OTHERS menu. For further de-tails, see the Operator’s Manual.

Deadsector

Figure 27 Dead sector

11. Checking magnetron heater voltage

Magnetron heater voltage is formed on theMD Board (03P9235) of the scanner unit, andis preadjusted at the factory for use with anylength of signal cable. Therefore no adjust-ment is required. However, check magnetronheater voltage as follows:

1. Turn on the radar and leave it in stand-by.

2. Open the scanner cover.

3. Unfasten four screws to remove the RFsection cover.

DANGERELECTRICAL SHOCK HAZARD

This check is done with thepower on — DO NOT touchthe magnetron.

Four screws

Magnetron

Figure 28 Scanner unit, cover opened

4. Connect a multimeter, set to 10 VDCrange, between test point J825#4 andJ825#6(GND) on the RTB Board(03P9249).

Measure voltageat this connector(J825).

Figure 29 Scanner unit, cover removed

5. Confirm the meter reads 7.6 V ±0.1 V.

6. Close the scanner cover and tighten thecover fixing screws.

Page 20: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

13

ARP-10 INSTALLATION

Necessary Parts

The Auto Plotter ARP-10 is an optional cir-cuit board which is accommodated in the dis-play unit of the FR-7062 to provide manualor automatic acquisition of 10 radar targets.

ARP-10 Installation Kit (000-086-852)

traP epyT .oNedoC ytQ

01-PRAdraoB 7009P81 039-674-800 1

recapS 02-QS 056-108-000 3

gnirpSrehsaW

3MW1915C 402-468-000 3

daeHnaPwercS

8X3MW0072C 404-188-000 3

daeHnaPwercS

rehsaw/w

8X301MRWS 477-508-000 3

Note: Spacers, spring washers and pan headscrews are not used.

In addition to the ARP-10 Board, a headingsensor which outputs heading data in AD for-mat in 25 msec intervals (for example,FURUNO PG-1000) is required.

Installation

1. Unfasten six screws to remove the displayunit cover.

2. Mate connector J107 on the SPU Boardwith connector P107 on the ARP-10Board.

3. Fix the ARP-10 Board with three pan headscrews (supplied).

Pan HeadScrew w/washer3 x 83 pcs.

J107

P107

SPU BoardSPU9211B

ARP-10 Board18P9007

FRONT

REAR

Figure 30 How to install the ARP-10

Page 21: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

14

Adjustments

1. Turn on heading and speed sensors. Turnon the radar and transmit.

2. Press the [MENU] key and select OTH-ERS menu.

3. Select 22. Self Test and press the [ACQ/ENTER] key. Confirm that the ARP-10test results show OK for SPEED,COURSE, TRIGGER, VIDEO, BP andHP.

[ Self Test ]

Program No. : 0359146-1XXROM : OKRAM : OKHours in use : 000006.9HTx hours : 000001.1H

<Press MENU for OTHERS menu.>

Key test: Press each key and check on-screen indication lights.

ARP-10 TESTROM OK 18590271xxRAM OK SPEED OK NAV 0.0KTCOURSE OK 167.6°TRIGGER OKVIDEO OKBP OKHP OKMIN-HIT 0003SCAN-TIME 0854MAN-ACQ 00AUTO-ACQ 00FE-DATA1 0000FE-DATA2 0000

Figure 31 Self test display

4. Adjust the GAIN, A/C and A/C RAIN con-trols so FE-DATA1 and FE-DATA2 indi-cations on the ARP-10 TEST show lessthan 1,000. Also, raise/lower the gainwhile watching the FE-DATA1 and FE-DATA2 indications. Confirm that the FE-DATA1 and FE-DATA2 indications rise/lower according to GAIN control adjust-ment.

Page 22: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING
Page 23: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING
Page 24: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

CODE NO.

TYPE

略  図

OUTLINE

名  称

NAME

数量

Q'TY用途/備考

REMARKS

番 号

NO.

型名/規格

DESCRIPTIONS

1/1

-2

INSTALLATION MATERIALS

工事材料表

03FR-X-9402

FR-7062

ケーブル組品MJ

CABLE ASSY.

MJ-B24LPF0005-100

1

選択 TO BE SELECTED

000-140-434

1

CODE NO.

ケーブル組品MJ

CABLE ASSY.

MJ-B24LPF0005-150

1

選択 TO BE SELECTED

000-140-435

2

CODE NO.

ケーブル組品MJ

CABLE ASSY.

MJ-B24LPF0005-200

1

選択 TO BE SELECTED

000-140-436

3

CODE NO.

ケーブル組品MJ

CABLE ASSY.

MJ-B24LPF0005-300

1

選択 TO BE SELECTED

000-140-437

4

CODE NO.

(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

FURUNO ELECTRIC CO .,LTD.

miyosi
テキストボックス
A-3
Page 25: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING
miyosi
テキストボックス
A-4
Page 26: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING
miyosi
テキストボックス
A-5
Page 27: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING
miyosi
テキストボックス
A-6
Page 28: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

PACKING LIST 19AK-X-9856 -5

XN10A,XN12A,XN13A

N A M E O U T L I N E DESCRIPTION/CODE № Q'TY

1/1

ユニット UNIT

アンテナ

ANTENNA

XN10A/12A/13A

008-390-960

1

**

アンテナ工材 ANTENNA INSTALLATION MATERIALS

Oリング

O-RING

JB1AG-80

000-851-313

1

ケミシール

SILICON RUBBER

S-8400W アルミチューブ50G

000-158-483

1

六角ボルト スリワリ

HEX.BOLT

M8X30 SUS304

000-862-151

4

ミガキ平座金

FLAT WASHER

M8 SUS304

000-864-130

4

バネ座金

SPRING WASHER

M8 SUS304

000-864-262

4

コ-ド番号末尾の[**]は、選択品の代表コードを表します。

CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL.

(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)

C3500-Z01-E

miyosi
テキストボックス
A-7
Page 29: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING
三好 悦子
Page 30: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING
yhatai
テキストボックス
Y. Hatai
miyosi
テキストボックス
D-2
Page 31: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

12V

-32VDC

J1351

321

GND

(-)

(+)

(VV-S

2.0x2C)

03S9235,5m,φ

10

BLK

WHT

シロ

クロ

12/24/32VDC

SHIP'SMAINS

船内

電源

6521

-+

(OPTION)

RU-3423

整流器

100/110/220/

RECTIFIER

230VAC,1φ

24V

*4 DPYC-2.5

NJC-203-PF

*1

指示部

DISPLAYUNIT

RDP-122

RSB-0073(48RPM)

RSB-0070(24RPM)

空中線

部ANTENNAUNIT

TUNING-CONT

TUNING-IND.

VH9P

VH4P

NH13P

*5

*5 *3*5VH2P

U2B6+12

-12

B2P-VH

J822VIDEO

4321

GND

SPARE

MBS-L

SPARE

SPARE

J824

B139_SHF_1AA_K

B4P-VH

J823 MOTOR(-)

HD.MOTOR(+)

B.P.

987654321

NC

P/L-B

P/L-A

TX-TRIG.

-12V

-12V

GND

+12V

+12V

B9P-VH

*1

J821

1 2 3 4 5 6 7 8 9 10111213 1 2

*2

5171978215

14

20

11

10 43 12

13616

21

24

19

22

18

RED(B)

ダイ

(太

)ミド

(太

ダイ

シロ

/ア

ムラ

アカ

シロ

/チ

シロ/

ダイ 2C2VYEL

GRN(B)

ORG(B)

WHT/ORG

ORG

REDWHT/RED

PPLWHT/BRN

PPL(B)

BLK

BLU(B)

WHT

ムラ(

太)

クロ

アオ(

太)

シロ

GRN

BLU

BRN

BRN(B)

WHT(B)

BLK(B)

YEL(B)

ミド

アオ

チャ

チャ

(太

)シロ

(太

)アカ

(太

)クロ

(太

)キ(

太)

DJ-1

*1(RW-6537,21C+2C2V,30mMAX.)

MJ-B24LPF0005,10/15/20/30m,φ

11

*4IV-2SQ.

CVDCONV.

信号変換器

FMD-811他

REMOTEDISPLAY

副指示器

RP-6065B

見張警報

外付ブザー

RP-110

RADARPLOTTER

レーダープロッタ

5/10/15/20/30m,φ

8

GND

V-SYNC

VIDEO

CRT12V

H-SYNC

GND

EXT-BUZZER

GND

+12V

B6P_SHF_1AA_K

1 32 1 65432

切換器

(FORRP-110)

SWITCHBOX

B5P_SHF_1AA_K

B3P_SHF_1AA_K

54321

GND

V-SYNC

VIDEO

H-SYNC

GND

J106

J109

J102

NH-4P

NH-3P

NH-5P

RW-4864,0.6m,φ

9.5

CO-0.2x1P,1m,

87654321

OP-VIDEO

GND

OP-TRIG.

GND

GP-BP

GND

TRU-HD

GND

RW-4864,0.6m,φ

9.5

B8P_SHF_1AA_K

J105

NH-8P

OP03-21

EXT.BUZZER

03S9334

OROTHERS

3C-2V,

30m

MAX.

FMD-1800

REM.DISPLAY

副指示器

SPU-9211B

U1B3

CRT

NMEA1I/O

GND

NCRX1-C

RX1-H

TX1-C

TX1-H

654321

J1352

*1

ミド

GRN

YEL

BLK

WHT

MJ-A6SPF

キクロ

シロ

(NMEA0183)

航法装置

NAVAID

MJ-A6SPF0012,5/10m,φ

6.5

HDG

AD-100

A-D

CONVERTER

ジャ

イロ

1

GND

NCCLK-C

CLK-H

DATA-C

DATA-H

65432

J1353

*1

MJ-A6SPF

ミド

キクロ

シロ

GRN

YEL

BLK

WHT

GYRO

A-Dコ

ンバータ

選択

φ6.5

MJ-A6SPF0003,5m

MJ-A6SPF0007,10m

MJ-A6SPF0009,10m

PG-1000

HEADINGSENSOR

方位指示器

NMEA2IN

(NMEA0183)

ECHOSOUNDER

魚群探知機

GND

NCRX2-C

RX2-H

TX2-C

TX2-H

654321

J1354

*1

MJ-A6SPF

ミド

キクロ

シロ

GRN

YEL

BLK

WHT

MJ-A6SPF0009,10m,φ

6.5

MJ-A6SPF0012,5/10m,φ6.5

03P9249

SELECT

RW-4747

A B C

12

34

kg

名称

NAME

TITLE

MASS

DWG.No.

SCALE

APPROVED

CHECKED

DRAWN

FR-7062

MARINE

RADAR

INTERCONNECTIONDIAGRAM

Dec.15

'03T.YAMASAKI

C3459-C01-

E

Dec.15

'03T.MATS

UGUC

HI船舶

用レーダ

相互結線図

注記

1)工場にて取付済み。

2)コネクタのクランプでアースする。

3)空中線部のシールドは完全にアースする。

NOTE

1.FITTED

ATFACTORY.

2.GROUND

THRUCONNECTORCLAMP.

4.SHIPYARDSUPPLY.

4)造船所手配。

5)信号ケーブルにEMIコア(3個)を取り付ける。

5.ATTACH

EMICORES(3PCS)TOSIGNALCABLES.

3.GROUND

EFFECTIVELYATANTENNAUNIT.

IV-8SQ.

*4

MATSUGUCHI
Dec. 19 '03
MATSUGUCHI
三好 悦子
S-1
Page 32: SAFETY INSTRUCTIONS - furunousa.com · SAFETY INSTRUCTIONS WARNING Wear a safety belt and hard ... service manual. Only qualified personnel should work inside the equipment. WARNING

The paper used in this manual

is elemental chlorine free.

FURUNO Authorized Distributor/DealerFURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho,9-52 Ashihara-cho,Nishinomiya 662-8580, JAPANNishinomiya 662-8580, JAPAN

Telephone :Telephone : 0798-65-21110798-65-2111FaxFax 0798-65-42000798-65-4200::

FIRST EDITION :FIRST EDITION : APR.APR. 19981998Printed in JapanPrinted in JapanAll rights reserved.All rights reserved.H3H3 :: JAN.JAN. 19, 200619, 2006

Pub. No.Pub. No. IME-34590-H3IME-34590-H3*00080820010**00080820010**00080820010**00080820010*(( YOSHYOSH )) FR-7062FR-7062

* 0 0 0 8 0 8 2 0 0 1 0 ** 0 0 0 8 0 8 2 0 0 1 0 *

*IME34590H30**IME34590H30**IME34590H30**IME34590H30*

* I M E 3 4 5 9 0 H 3 0 ** I M E 3 4 5 9 0 H 3 0 *