2 Safety System CES-AZ Subject to technical modifications; no responsibility is accepted for the accuracy of this information. 7 97,1 10 57,5 Ø 5,2 (2x) R4 M5 3,3 8,3 5 R3 18,1 Read head CES-A-LSP-... Dimension drawing Read head CES-A-LSP-... M5 plug connector, 3-pin or hard-wire encapsulated cable Active face Optimized for aluminum profile mounting LED for the indication of the door position Y 15 20 25 30 5 Z X 5 15 20 25 30 -20 -25 -30 -45 -50 -55 -60 -65 -40 -35 -15 -10 -5 25 30 15 10 45 50 55 60 65 35 5 20 10 40 10 Typical operating distance Installed in aluminum profile 45 x 45 mm Terminal assignment H11 H12 SH1 BN WH 1 3 4 Screen Read head CES-A-LSP CES-AZ... Connection cable see page 72 For possible combinations see page 24 Attention: The operating distance may vary de- pending on the background material and installation situation. Important: Actuators must be ordered sepa- rately! See page 42. Ordering table Series Cable type/connection type/version Cable length [m]/description Order no. / item CES-A-LSP-... V PVC cable 5 1049 CES-A-LSP-05V-104966 10 10497 CES-A-LSP-10V-104967 15 10271 CES-A-LSP-15V-106271 20 10272 CES-A-LSP-20V-106272 25 10498 CES-A-LSP-25V-104968 SB M5 plug connector - 10499 CES-A-LSP-SB-104969 Installation material for CES-A-LSP-... For Bosch profiles with 8 mm groove 2 screws and 2 clamping pieces 10 Installation material 8-groove Bosch For Bosch profiles with 10 mm groove 2 screws and 2 clamping pieces 104 Installation material 10-groove Bosch For ITEM profiles with 8 mm groove 2 screws and 2 clamping pieces 105 Installation material 8-groove ITEM With M5 plug connector With connection cable Mounting distance CES-A-LSP-... 10 5 20 LED

Upload: vudien

Post on 26-Feb-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

�2

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

7

97,1

1057

,5Ø 5,2 (2x)

R4

M5

3,3

8,3

5

R3

18,1

ReadheadCES-A-LSP-...

Dimensiondrawing

ReadheadCES-A-LSP-...M5 plug connector, 3-pin or hard-wire encapsulated cable

Active face

OptimizedforaluminumprofilemountingLEDfortheindicationofthedoorposition

Y

1520

2530

5

ZX

5

1520

2530

-20

-25

-30

-45

-50

-55-60

-65

-40

-35

-15

-10

-5

25

30

15

10

45

50

55

60

65

35

5

20

10

40

10

TypicaloperatingdistanceInstalled in aluminum profile 45 x 45 mm

Terminalassignment

H11 H12 SH1

BNWH

13

4

ScreenRead headCES-A-LSP

CES-AZ...

Connection cable see page 72

For possible combinations see page 24

Attention:The operating distance may vary de-pending on the background material and installation situation.

Important:Actuators must be ordered sepa-rately! See page 42.

Orderingtable

Series Cabletype/connectiontype/version Cablelength[m]/description Orderno./item

CES-A-LSP-...

VPVC cable

5 1049��CES-A-LSP-05V-104966

10 1049�7CES-A-LSP-10V-104967

15 10�271CES-A-LSP-15V-106271

20 10�272CES-A-LSP-20V-106272

25 1049�8CES-A-LSP-25V-104968

SBM5 plug connector - 1049�9

CES-A-LSP-SB-104969

InstallationmaterialforCES-A-LSP-...

For Bosch profiles with 8 mm groove 2 screws and 2 clamping pieces 10����Installation material 8-groove Bosch

For Bosch profiles with 10 mm groove 2 screws and 2 clamping pieces 10���4Installation material 10-groove Bosch

For ITEM profiles with 8 mm groove 2 screws and 2 clamping pieces 10���5Installation material 8-groove ITEM

With M5 plug connector

With connection cable

Mounting distanceCES-A-LSP-...

≤105

≤20

LED

��

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

CES

-AZ

TechnicaldatareadheadCES-A-LSP-...

Parameter Value Unit

min. typ. max.

Housing material Reinforced thermoplastic, fully encapsulated

Weight (without connection cable) 0.02 kg

Ambient temperature -25 - +70 °C

Degree of protection IP67

Installation position Any

Method of operation Inductive

Power supply Via evaluation unit

Connection M5 plug connector, 3-pin

LED indicator White, valid actuator detected

IncombinationwithactuatorCES-A-BSP-104970

Operating distance for center offset m = 0 1)

mm

with vertical approach direction (x direction)

- Assured switch-off distance Sar - - 45

Cable length l = 0 to 25 m

- Switch-on distance - 20 -

- Assured switch-on distance Sao 10 - -

- Switching hysteresis 1 4 -

Cable length - - 25 m

1) These values apply for the installation of the read head and the actuator in an aluminum profile 45 x 45 mm.

�4

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

25

42 ±0,

1

52,7

5,4

8

9

4,1

5,3

12

4,5

4,1 19

,4

4,6

32

ReadheadCES-A-LNN-...

Dimensiondrawing

ReadheadCES-A-LNN-...M8 plug connector, 3-pin or hard-wire encapsulated cable

Active face

Rectangulardesign42x25mmAttachmentcompatiblewithseriesCES-A-LNA/LCALEDfortheindicationofthedoorposition

Z

-25-30

X

105

1520

-20

-25

-30

-40

-35

-15

-10

-5

-10

20

25

30

15

10

40

35

5

Y

1015

2025

5-5

-15

-20

30

TypicaloperatingdistanceTerminalassignment

H11 H12 SH1

BNWH

14

3

Screen

Read head

CES-AZ...

For connection cable see page 69

For possible combinations see page 24

Attention:The operating distance may vary de-pending on the background material and installation situation.

Important:Actuators must be ordered sepa-rately! See page 43.

Orderingtable

Series Cabletype/connectiontype Cablelength[m] Orderno./item

CES-A-LNN-...

VPVC cable 5 10��02

CES-A-LNN-05V-106602

SCM8 plug connector - 10��01

CES-A-LNN-SC-106601

With M8 plug connector

With connection cable

Approachdirections

LEDActive face

Active face

For a side approach direction for the actuator and read head, a minimum distance of s = 6 mm must be maintained so that the

operating distance of the side lobes is not entered.

2 safety screws M4x14 included

�5

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

CES

-AZ

TechnicaldatareadheadCES-A-LNN-...

Parameter Value Unit

min. typ. max.

Housing material Reinforced thermoplastic (PBT), fully encapsulated

Dimensions 42 x 25 x 12 mm

Weight (without connection cable) 0.025 kg

Ambient temperature -25 - +70 °C

Degree of protection IP67

Installation position Any

Method of operation Inductive

Power supply Via evaluation unit

Connection M8 plug connector, 3-pin or connection cable

LED indicator White, valid actuator detected

IncombinationwithactuatorCES-A-BBN-10��00

Operating distance for center offset m = 0 1)

mm

- Assured switch-off distance Sar in x/z direction - - 50

in y direction - - 80

Cable length l = 0 to 25 m

- Switch-on distance - 20 -

- Assured switch-on distance Sao 10 - -

- Switching hysteresis 1 4 -

IncombinationwithactuatorCES-A-BDN-0�-1047�0

Operating distance for center offset m = 0

mm

- Assured switch-off distance Sar in x/z direction - - 80

in y direction - - 50

Cable length l = 0 to 25 m

- Switch-on distance - 19 -

- Assured switch-on distance Sao 14 - -

- Switching hysteresis - 4 -

Cable length - - 25 m

1) These values apply for the surface installation of the read head and the actuator.

��

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

ReadheadCES-A-LC.../CES-A-LN...Rectangulardesign42x25mm

CES-

A-L

XXXX

XX

25

∅8

∅4,5

42

32±

0,1

12

4,6

"l"

ReadheadCES-A-LNA... (Fortron)Hard-wired encapsulated cable

Active face

Active face

5,5

∅10

6,8

∅8

∅4,5

4,6

12

25

min

.38

32±

0,1

4232

,6

A0

CES-

A-L

0777

15

3 41

ReadheadCES-A-LNA-SC (Fortron)M8 plug, 3-pin

Activeface

Active face

Orderingtable

Series Cabletype/connectiontype Cablelength[m] Version Orderno./item

CES-A-LCA-... VPVC cable 10 Housing material PE-HD 2) 088785

CES-A-LCA-10V

CES-A-LNA-...

VPVC cable

5 071845CES-A-LNA-05V

10 07184�CES-A-LNA-10V

15 071847CES-A-LNA-15V

25 071975CES-A-LNA-25V

PCable PUR

5 07780�CES-A-LNA-05P

10 077807CES-A-LNA-10P

15 084�82CES-A-LNA-15P

SCM8 plug connector - 077715 3)

CES-A-LNA-SC

CES-A-LNA-SC-EX SCM8 plug connector - ATEX 1) 09815� 1) 3)

CES-A-LNA-SC-EX

1) EX II 3G Ex nL IIC T70°C (zone 2 gases)2) Suitable for use in aggressive media (e. g. acids, alkalis)3) Plug connector suitable for snap-action and screw terminals

1)

TypicaloperatingdistanceTerminalassignment

32

4248

25

31

l

1214

4,6 ∅8

∅4,5

± 0

,1

Dimensiondrawing

ReadheadCES-A-LCA... (PE-HD)Hard-wired encapsulated cable

Active face

Activeface

Seal

X20

1510

5

2015

105

5

10

15

20

Y

Z

For a side approach direction for the actuator and read head, a minimum distance of s = 3 mm must be maintained so that the

operating distance of the side lobes is not entered.

H11 H12 SH1

BNWH

14

3

Screen

Read head

CES-AZ...

For connection cable see page 69

2 safety screws M4x14 included

2 safety screws M4x14 included

2 safety screws M4x14 included

For possible combinations see page 24

Attention:The operating distance may vary de-pending on the background material and installation situation.

Important:Actuators must be ordered sepa-rately! See page 45 and 47.

�7

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

CES

-AZ

Parameter Value Unit

min. typ. max.

Housing material- CES-A-LNA-... Fortron, reinforced thermoplastic, fully encapsulated

- CES-A-LCA-... Plastic PE-HD without reinforcement, fully encapsulated

Flat seal material (CES-A-LCA-... only) Fluororubber 75 FPM 4100

Dimensions 42 x 25 x 12 mm

Weight (incl. 10 m cable) 0.3 kg

Ambient temperature

°C- CES-A-LCA-... -25 - +50

- CES-A-LNA-.../CES-A-LNA-SC-EX -25 - +70

Degree of protection

- CES-A-LCA-... IP67

- CES-A-LNA-.../CES-A-LNA-SC-EX IP67/IP69K

Installation position Any

Method of operation Inductive

Power supply Via evaluation unit

IncombinationwithactuatorCES-A-BBA

Operating distance for center offset m = 0 1)

mm

- Assured switch-off distance Sar - - 26

Cable length l = 0 to 25 m

- Switch-on distance - 15 -

- Assured switch-on distance Sao 10 - -

- Switching hysteresis 0.5 2 -

Connection cable- CES-A-LCA-.../CES-A-LNA-...- CES-A-LNA-...

Hard-wired encapsulated connection cable, with crimped ferrulesPVC, ∅ 4.6 mm

PUR, ∅ 4.8 mm, suitable for drag chain

- CES-A-LNA-SC M8 plug connector (snap-action and screw terminals), 3-pin

Cable length See ordering table 25 m1) These values apply for surface installation of the read head and the actuator.

TechnicaldatareadheadCES-A-LC.../CES-A-LN...

�8

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

40 ±0,15

50 0,250

M8

40±

0,15

500,

250

20

7

6

20,2

Ø4,

5

-

x1

-

ReadheadCES-A-LQA-SC

Dimensiondrawing

ReadheadCES-A-LQA-SCM8 plug, 3-pin

Active face

Rectangulardesign50x50mmM8plugconnector(snap-actionandscrewterminals)

Orderingtable

Series Connection Comment Orderno./item

CES-A-LQA-SC SCM8 plug connector

2 safety screws M4 x 14 are supplied

095�50CES-A-LQA-SC

TypicaloperatingdistanceTerminalassignment

H11 H12 SH1

BNWH

14

3

Screen

Read head

CES-AZ...

For connection cable see page 69

For possible combinations see page 24

Attention:The operating distance may vary de-pending on the background material and installation situation.

Important:Actuators must be ordered sepa-rately! See page 46.

10

-30

2030

Z

Y

10

20

30

-30

30

20

10

X

With actuator CES-A-BBA or CES-A-BCA on evaluation unit CES-AZ

1020

30

Y

10

20

30

20

10

X 30Z

With actuator CES-A-BQA on evaluation unit CES-AZ

�9

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

CES

-AZ

TechnicaldatareadheadCES-A-LQA-SC

Parameter Value Unit

min. typ. max.

Housing material Fortron, reinforced thermoplastic, fully encapsulated

Dimensions 50 x 50 x 20.2 mm

Weight 0.08 kg

Ambient temperature -25 - +70 °C

Degree of protection IP67

Installation position Any

Method of operation Inductive

Power supply Via evaluation unit

IncombinationwithactuatorCES-A-BBAorCES-A-BCAonevaluationunitCES-AZ

Operating distance for center offset m = 0 1)

mm

- Assured switch-off distance Sar - - 47

Cable length l = 0 to 25 m

- Switch-on distance - 15 -

- Assured switch-on distance Sao 10 - -

- Switching hysteresis 2 3 -

IncombinationwithactuatorCES-A-BQAonevaluationunitCES-AZ

Operating distance for center offset m = 0 1)

mm

Cable length l = 0 to 25 m

- Assured switch-off distance Sar - - 60

For vertical approach direction

- Switch-on distance - 23 -

- Assured switch-on distance Sao 16 - -

- Switching hysteresis 2 3 -

For side approach direction

- Switch-on distance - 28 -

- Assured switch-on distance Sao 24 - -

- Switching hysteresis 1 1.3 -

Cable length - - 25 m

1) These values apply for surface installation of the read head and the actuator.

40

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

17

5

32 19,7

Read distance s

Cent

er o

ffset

m

connected 35

4

830

M12

x1

M8x

1

37

1)

1)

ReadheadCES-A-LMN-SC

Dimensiondrawing

ReadheadCES-A-LMN-SCM8 plug, 3-pin

Active face

CylindricaldesignM12M8plugconnector(snap-actionandscrewterminals)

Orderingtable

Series Connection Version Orderno./item

CES-A-LMN-SC SCM8 plug connector Housing M12 077790

CES-A-LMN-SC

CES-A-LMN-SC-EX SCM8 plug connector ATEX 1) 098157 1)

CES-A-LMN-SC-EX

1) EX II 3G Ex nL IIC T70°C (zone 2 gases)

TypicaloperatingdistanceTerminalassignment

H11 H12 SH1

BNWH

14

3

Screen

Read head

CES-AZ...

1) Clear zone (area of the active face without metal housing)For connection cable see page 69

For possible combinations see page 24

Attention:The operating distance may vary de-pending on the background material and installation situation.

Important:Actuators must be ordered sepa-rately! See page 48.

1)

A minimum distance of s = 1.2 mm must be maintained.

2

4

6

6

8

8

X8

64

22

46

8

86

Y

Z

41

Safety System CES-AZ

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

CES

-AZ

Parameter Value Unit

min. typ. max.

Housing material Nickel-plated CuZn housing sleevePlastic PBT GF20 cap

Dimensions M12 x 1, length 38 mm

Weight 0.2 kg

Ambient temperature

°C- CES-A-LMN-SC -20 - +70

- CES-A-LMN-SC-EX -20 - +60

Ambient pressure(only of active face in installed condition) - - 10 bar

Degree of protection IP67

Installation position Any

Method of operation Inductive

Power supply Via evaluation unit

IncombinationwithactuatorCES-A-BMB

Operating distance for center offset m = 0 1)

mm

- Assured switch-off distance Sar - - 10

Cable length l = 0 to 15 m

- Switch-on distance - 5 -

- Assured switch-on distance Sao 3.5 - -

- Switching hysteresis 0.1 0.3 -

Connection M8 plug connector (snap-action and screw terminals), 3-pin

Cable length - - 15 m1) These values apply for surface installation of the read head in steel.

TechnicaldatareadheadCES-A-LMN-SC