SafidAir Terminals

PageType

265

286

273

255

235

PageType

Contents

IIIIIIII.IIIIII_IIIII 234

II

Page 2: Safid

III

SafidAir TerminalsVAV Air Terminal UnitsSingle Duct, Pressure-Independent

SVT 500 Series

Right to alterations reserved.~ 4....<I)l..c. ~I!lIS a leglstered tlade mark

~ y •• ., ~L..... - ,u,r"-""'-4 j~1~ tLJ if) copyright SAFID 2009 - All R,ghts Reserved

Standard Construction

235

Option 1: Code SFSlide on Flange connections for discharge side.Option 2: Code PAir Terminal with galvanized perforated sheet behindthe acoustic lining.Option 3: Code SAAir Terminal with Factory mounted Sound Attenuator onthe discharge side of Air Terminal Casing.Option 4: Code OPAir Terminal with Factory mounted mUltiple outletplenum.Option 5: Code EHAir Terminal with Electric heater Factory mounted onthe discharge side of the Air Terminal casing,Option 6: Code HWAir Terminal with Hot water coil Factory mounted on thedischarge side of the Air Terminal casingOption 7: Code FCAir Terminal with flexible connector mounted on the inletcollar of the Air Terminal casing.Option 8: Code MAir Terminal with Selimo actuator/controller.Option 9: Code CSAir Terminal with control boxOption 10: Code TCWith digital room temperature controller.

SAFID SVT 500 Series VAV air terminals are designedto achieve variable air volume supply of conditionedair to a room in single duct air distribution systemsThe SVT air terminals are equipped with air flowsensor in the unit's inlet to allow pressure-independentcontrol of air flow on the basis of a control signal andfitted with Belimo controller/actuator. The Belimoactuator/controller is linearized with the SVT 500 Seriesin order to achieve a high standard performance of theVAV air terminals. They have a wide range of sizes withcapacities from 150CFM to 7850CFM. The SVT 500Series will work equally well in Variable Air Volume(VAV) and Constant Air Volume (CAV) systems. The airvolume supplied to the room varies in direct responseof actuator to signals from the room thermostat tomaintain the room designed temperature while the airflow controller maintain the maximum and minimumamount of designed air flows to be supplied to theroom The SVT air terminals are available with a varietyof accessories. They can be specified with SoundAttenuator, Electric Heater. Hot Water Coil, multipleoutlet plenum and other optional accessories. Theaccessories (except the multiple outlet plenums) areshipped factory attached to SVT air terminals and havea standard slip & drive connections.

Description

Options:

SlipDriveand

Casing:Air Terminal casing, Inlet & Damper are built of 22gauge galvanized steel sheet, conform to ASTM A653.LFQ, G90 zinc coating.

Insulation:25mm thk. Acoustic lining with a strong anddimensionally stable Woven Glass Fiber Fabric (WGF)facing. 48kg/M3 density. complies with therequirements of NFPA 90A.

Air Flow Sensor:Aluminum multiple averaging flow probe that offers anexcellent air flow sensing capability.

Controls:The SVT Air terminals can be specified with electriccontrols. Standard control are BelimoActuator/controller modulating type

Standard Connections: S-slipconnection for discharge side.

SVT 500IIII

I

IeI

III1_

IIIIIII

Page 3: Safid

Right to alterations reserved.~ <L4)U. ~«Iis a registered trade mark

r'" ,C\ ~L-. - 4..b~ j,...t.J.1~ ~ (l copyright SAFID 2009 All Rights Reserved

Note:The minimum straight portion before the VAV must be equal to 2 times the diameter of the inlet size of VAV tomaintain the integrity of airflow sensor's performance.

CONTAOLBOX(OPTIONAL)

STEp· DOWN TRANSFORMERL AND TERMINAL BLOCK

( OPTIONAL)

SVT 500 Series

60L1

_ICONTROL SOX ---..J \

( OPTIONAL I ~ SLIP & DRIVECONNECTION

SIDE VIEW

120

lINLET SIZE W

~ , I\.\...'--r-~-...,.--.-'.~

AIR FLOW

120 LI

AIR FLOW I lINLET SIZE --- ----J n-- ~,

SPIGOT INLET1.--

J355

SELIMO ACTUATORiCONTROLLER(OPTIONAL.

160 rI

w

AlA FLOW SENSOR

TOP VIEW

ACOUSTIC LINEA25mm THICK ,48kglm3 DENSITY

FRONT VIEW

r 0 IH 300

LL.------r-;---°~l CONTROL BOX

(OPTIONAL)

MODELUNIT SIZE INLET SIZE CASING SIZE ( mm )

( inches) (mm) W H L L1

SVT 506 6 152 300 300 425 155

SVT 508 8 200 350 300 425 155

SVT 510 10 250 400 325 450 180

SVT 512 12 305 450 375 475 205

SVT 514 14 350 500 420 495 225

SVT 516 16 400 550 470 520 250

SVT 518 18 450 600 520 545 275

SVT 520 20 500 650 570 570 300

SVT 524 24 600 750 670 670 350

SVT 500: Basic Air Terminals

SVT 500: Dimensions

SVT 500: Dimensions

VAV Air Terminal UnitsSingle Duct, Pressure-Independent

SafidAir Terminals

IIIIIIIIIII.mIIIIIII 236

II

Page 4: Safid

III

SafidAir TerminalsVAV Air Terminal UnitsSingle Duct, Pressure-Independent

~®~

SVT 500 Series

II

SVT SOO-SA: Air Terminals with Downstream Sound Attenuator

SVT SOO-SA: Dimensions

ATIEUATOA WIDTH(WI

t-

ATTENUATOA HEIGHT(H)

---1- _

SIDE VIEW

CONTROL BOX~I OPTIONAL)

______ SVT 500-SA ~

(L)SOUND ATIENUATOA

(L.900 )

CONTROL BOX(OPTIONAL)

STEP-DOWN TRANSFORMERAND TERMINAL BLOCK(OPTIONAL)

______ SVT 500-SA ....,

I L ISOUND ATIENUATOAr- (L"900)

lilA FLOW

~ CONTROL BOX(OPTIONAL I

1 '60 r

ACOUSTIC LINER SPIGOT INLET

25mm THICK 4~l<otm3DENSITY l:-:---i 355• BELIMO ACTUATOR/CONTROLLER ,

SOUND AITENUATOR'S ( OPTIONAL) -SIDE SPUITER

AlA Fl.OW SENSOR

TOP VIEW

FRONT VIEW

II

IIIIII

SVT SOO-SA: Dimensions

IIIII

UNIT SIZE INLET SIZE SVT 500-SA SOUND ATTENUATOR (SA)MODEL

( inches) (mm) W H L W H L

SVT 506-SA 6 152 300 300 1325 300 300 900

SVT 508-SA 8 200 350 300 1325 300 350 900

SVT 510-SA 10 250 400 325 1350 325 400 900

SVT 512-SA 12 305 450 375 1375 375 450 900

SVT 514-SA 14 350 500 420 1395 420 500 900

SVT 516-SA 16 400 550 470 1420 470 550 900

SVT 518-SA 18 450 600 520 1445 520 600 900

SVT 520-SA 20 500 650 570 1470 570 650 900

SVT 524-SA 24 600 750 670 1570 750 670 900

IRight to alterations reserved.~ <L....oL ~<8lIS a registered trade mark

t'l' •• " ~L... - .i...b~ jt-DI~ ~ e copyright SAFID 2009 - All Rights Reserved 237

II

Page 5: Safid

II1

SafidAir TerminalsVAV Air Terminal UnitsSingle Duct, Pressure-Independent

SVT 500 Series

w

S,OSLIP II DRIVE

CON ECTION

CONTROLCOMPARTMENT

---510

100LI -----+---- G'O -------1

HECIRIC HEA1E

r----L!--

STEP-DOWN TRANSFORMERAND TERMINAL BLOCK --~

tOPtlONAL,

CONTROL ao --'IOPTIO ilL)

END POINT OF ACOUSTIC LININGWITH INSULATION GUilflD

AIR FLOW---j-

INLET SllE

SPIGOT INLET ---.. ,120 ~

\

SIDE VIEW

I 120

J\.\........-----.---~-.,---------r-,ICONTROL

BEUMO IICTUATORtCONTROLLER _ -<=----.....---J COMPAR"rMENT(OPTIONAL I l--- 355 -i---~

CONTROLCOMPIIRTM NT

CONTROL BOXl OPTlor,IIL \

I HEA riNG ",LEM T

IIIR FLOW SENSOR

TO, V I I·. ViI

ACOUS-I IC LINEA25m~1 THICK. 6~gl""3 DENSITY

FRONT' VTEW

I('f ~

~ SVT500 EHo~ L 1

SVT 500-EH: Air Terminals with Downstream Electric Heater

SVT 500-EHO: Dimensions with Open Coil

II

I

II

I

I

I~

I

I1-I1II

SVT 500-EHO: Dimensions

UNIT SIZE INLET SIZESVT 500-EHO

MODEL W H L L1( inches) (mm) (mm) (mm) (mm) (mm)

SVT 506·EHO 6 152 300 300 1135 525SVT 508·EHO 8 200 350 300 1135 525SVT 510·EHO 10 250 400 325 1160 550SVT 512·EHO 12 305 450 375 1185 575SVT 514-EHO 14 350 500 420 1205 595SVT 516·EHO 16 400 550 470 1230 620SVT 518·EHO 18 450 600 520 1255 645SVT 520·EHO 20 500 650 570 1280 670SVT 524·EHO 24 600 750 670 1380 770

Notes:1. The minimum straight portion before the VAV must be equal to 2 times the diameter of the inlet size of VAV tomaintain the integrity of airflow sensor's performance.2. The straight portion after the electric heater up to elbow or any fittings that will change the airflow's direction mustbe equal to minimum length of 610mm.3. Contact SAFID for electric heater details.

IRight to alterations reserved.~ <i...A:.L....;_ ~®IS a registered trade mark

,.. 'f •• ~ ~L..... - J..L.9-"--"'-'<l j~1 ~ ldLJ © copyright SI\FID 2009 - All Rights Reserved 239

II

Page 6: Safid

III

SafidAir TerminalsVAV Air Terminal UnitsSingle Duct, Pressure-Independent

SVT 500 Series

IIIIIIIIIIIIIIII 242

II

Performance Data

Table 1

Rated Inlet Min. S.P. Discharge Sound Power Level (dB)Inlet Air Flows Velocity (in. w.G.) @ 1 in. W.G. S.P. @ 2 in. W.G. S.P. @ 3 in. W.G. S.P.

Size Inlet NC Octave Band NC Octave Band NC Octave Band NC

CFM m3 /s FPM S.P. 2 3 4 5 6 7 2 3 4 5 6 7 2 3 4 5 6 7

150 0.071 764 0.020 <20 61 56 49 38 36 39 <20 62 58 62 46 45 47 20 62 62 61 52 50 49 23250 0.118 1273 0.Q36 <20 64 62 55 45 41 43 24 66 64 61 48 46 48 27 68 67 63 53 51 51 30

6 350 0.165 1783 0.080 <20 68 67 61 51 45 46 25 73 69 60 49 47 50 29 74 72 66 54 52 53 33450 0.212 2292 0.120 <20 70 67 62 51 45 47 27 73 71 63 49 47 50 31 74 74 66 54 52 54 35550 0.260 2801 0.220 <20 72 69 62 51 45 47 29 74 72 65 48 46 50 33 74 76 66 55 53 54 37200 0.094 573 0.026 <20 60 53 48 39 40 41 <20 62 57 55 47 46 49 22 64 60 58 52 50 52 25400 0.189 1146 0.036 <20 65 57 50 41 41 41 <20 68 65 58 50 48 49 24 71 67 63 56 52 52 27

8 600 0.283 1719 0.076 <2C 70 60 53 44 41 41 23 74 70 62 54 50 49 30 77 73 67 59 55 53 33800 0.378 2292 0.136 <2C 73 64 57 47 45 43 24 79 71 64 55 51 50 32 80 76 69 61 56 54 351000 0,472 2865 0.200 <2C 75 67 60 51 48 45 27 83 73 66 57 53 51 37 83 78 71 62 58 55 37400 0.189 733 0.Q28 <2C 64 57 49 42 43 43 <2C 70 63 57 51 50 50 23 71 64 60 56 53 53 24700 0.330 1283 0.036 <2C 68 61 55 47 47 46 20 74 67 59 53 51 51 28 76 70 64 58 55 55 31

10 1000 0,472 1833 0.076 <20 73 66 61 52 51 50 24 78 70 61 54 53 52 30 79 74 67 59 57 56 331300 0.613 2383 0.116 <20 75 68 63 54 53 52 27 79 72 63 56 54 53 32 81 75 67 60 57 57 351600 0.755 2934 0.172 <2C 77 70 65 56 55 55 30 81 73 65 57 55 54 35 83 76 68 60 58 57 37700 0.330 891 0.027 <2C 63 55 48 45 45 42 <20 73 68 57 53 51 50 28 73 72 65 59 55 54 331050 0,495 1337 0032 <2C 66 56 50 46 46 44 <20 77 73 59 55 52 52 30 78 75 65 60 56 55 34

12 1400 0.661 1783 0.040 <2C 67 57 52 47 46 45 <20 79 71 60 55 53 52 32 82 74 65 60 57 56 361750 0.826 2228 0.072 <2C 68 60 55 49 47 46 <20 80 73 63 57 55 54 33 83 75 66 61 59 57 372100 0.991 2674 0.120 <2C 71 62 58 50 47 46 20 82 76 65 60 57 56 36 84 77 67 62 60 58 39800 0.378 748 0.019 <2C 57 51 48 45 44 42 <20 72 66 56 52 51 51 23 73 72 62 58 55 55 301350 0.637 1263 0.032 <2C 61 54 50 47 46 44 <20 74 66 58 54 52 53 26 77 74 63 59 57 57 33

14 1900 0.897 1777 0.048 <20 65 57 53 49 48 47 <20 76 66 60 56 54 55 28 81 74 64 61 59 59 352450 1.156 2292 0.076 <20 70 60 57 51 49 48 20 77 68 62 57 55 55 30 82 75 66 62 59 59 363000 1.416 2806 0.116 <20 72 64 61 54 51 49 22 79 70 64 59 56 56 32 84 75 67 63 60 60 391000 0.472 716 0.015 <20 66 53 48 47 47 46 <20 76 68 56 55 53 53 28 78 70 64 60 57 56 311750 0.826 1253 0.028 <20 68 56 52 50 49 47 <20 78 69 59 57 54 54 31 80 71 66 61 59 58 33

16 2500 1.180 1790 0.Q36 <20 70 59 56 52 50 48 20 80 70 61 59 56 55 33 82 72 67 62 60 59 363250 1.534 2328 0.056 <20 72 62 60 54 51 49 23 81 71 64 61 57 56 35 83 73 68 64 62 60 374000 1.888 2865 0.084 <20 74 65 64 57 53 50 26 83 72 66 62 59 57 37 85 74 69 65 63 61 401300 0.613 736 0.015 <20 65 54 51 49 48 48 <20 74 68 58 57 57 58 26 74 73 64 63 61 61 312225 1.050 1259 0.026 <20 68 56 52 50 49 48 <20 76 69 60 58 58 58 28 79 73 65 63 61 62 32

18 3150 1.486 1783 0.032 <20 69 58 52 51 50 48 <20 78 69 62 59 59 58 31 81 73 65 64 61 62 354075 1.923 2306 0.042 <20 72 61 59 54 52 49 23 80 70 63 60 59 58 33 83 74 67 64 62 62 375000 2.360 2829 0.055 <2C 75 65 66 56 54 51 27 82 70 65 61 60 58 36 85 74 68 65 64 62 401600 0.755 733 0.019 <20 64 52 50 49 49 46 <20 73 63 58 57 57 56 24 75 70 64 63 63 61 292950 1.392 1352 0.025 <2( 68 56 50 50 50 49 <2C 75 63 59 57 57 56 27 78 70 64 64 63 61 31

20 4300 2.029 1971 0.032 <2( 77 62 54 51 51 49 30 80 67 60 58 57 57 33 84 72 65 64 64 62 395150 2.430 2361 0.045 <2( 80 66 58 53 52 50 33 84 71 62 60 58 58 39 87 75 66 64 64 63 436000 2.831 2750 0.061 <2( 84 70 62 56 54 52 39 88 74 65 61 59 59 44 90 77 68 65 65 64 462250 1.062 739 0.020 <2( 65 53 50 49 49 46 <2C 74 63 58 57 57 56 25 76 70 64 63 63 61 283600 1.699 1183 0.023 <2C 67 55 50 50 50 48 <20 75 63 59 57 57 56 26 n 70 64 64 63 61 30

24 4950 2..336 1626 0.028 <2C 72 59 52 51 51 49 23 77 65 60 58 57 57 30 81 71 65 64 64 62 356400 3.020 2103 0.036 <2C 78 64 56 52 52 50 31 82 69 61 59 58 58 36 85 73 66 64 64 63 407850 3.704 2579 0.054 <2C 82 69 61 55 53 51 36 87 73 64 61 59 59 42 88 76 67 64 64 63 43

Notes:1. The performance data shown is based on tests conducted in accordance with ARI Standard 880-98 and ASHRAE Standard 130.2. Measurement of Sound Power Levels is in accordance with International Standard ISO 3741 comparison method3. The Noise Criteria (NC) calculation is based on ARI Standard 885-98. See Table 4 for sound attenuation calculation

Right to alterations reserved.~ <L..oo'i....c. ~is a. registered trade mark

fY •• 1\ ~l...- - 4...b~ ,;~I ~ ~ () copynght SAFID 2009 - All Rights Reserved

Page 7: Safid

III

SafidAir TerminalsVAV Air Terminal UnitsSingle Duct, Pressure-Independent

~®~

SVT 500 Series

IIIIIIIIIIIIIIIIII

Performance Data

Table 2

Rated Inlet Min. S.P. Radiated Sound Power Level (dB)

Inlet Air Flows Velocity (in. w.G.) @ 1 in. W.G. S.P. @ 2 in. W.G. S.P. @ 3 in. W.G. S.P.

Size Inlet NC Octave Band NC Octave Band NC Octave Band NC

CFM m'ts FPM S.P. 2 3 4 5 6 7 2 3 4 5 6 7 2 3 4 5 6 7

150 0.071 764 0,020 <20 48 41 31 17 12 12 <20 46 43 43 25 20 20 <2C 49 46 43 31 26 22 <20250 0.118 1273 0.036 <20 52 46 37 23 16 15 <20 54 51 43 26 22 21 <20 55 53 45 32 27 24 21

6 350 0.165 1783 0.080 <20 55 51 42 29 20 19 <20 61 54 42 28 23 22 23 62 56 47 33 27 26 24450 0.212 2292 0.120 <20 58 52 42 29 20 19 <20 61 56 44 28 23 23 24 62 59 47 33 28 27 28550 0.260 2801 0.220 <20 60 54 44 30 21 20 22 62 57 46 29 24 23 25 63 61 48 34 29 28 30200 0,094 573 0.026 <2<: 48 38 30 17 15 14 <2C 50 42 36 25 22 22 <20 52 44 40 31 26 24 <2C400 0.189 1146 0.Q36 <20 53 41 32 20 16 14 <20 56 50 40 29 24 22 <20 58 52 44 34 28 25 <2C

8 600 0.283 1719 0.076 <20 58 45 35 22 17 15 <20 62 54 44 33 26 22 24 65 57 49 38 30 26 28800 0.378 2292 0.136 <20 60 48 38 26 20 16 22 66 56 46 34 27 23 30 68 61 51 39 32 27 321000 0.472 2865 0.200 <20 63 52 42 29 24 18 26 70 58 48 36 29 24 35 71 62 52 41 33 28 36400 0.189 733 0.028 <20 52 42 30 21 19 15 <20 58 48 38 30 26 23 <20 59 49 42 34 29 26 20700 0.330 1283 0.036 <20 56 46 37 26 23 19 <2C 62 51 41 31 27 24 24 63 55 45 36 31 27 26

10 1000 0.472 1833 0.076 <20 60 50 43 31 26 23 22 65 55 43 33 28 25 28 67 59 49 38 33 29 311300 0.613 2383 0.116 <20 63 52 45 33 29 25 26 67 57 45 34 30 26 31 69 60 49 39 33 29 331600 0.755 2934 0.172 <20 65 55 47 35 31 27 28 69 58 47 36 31 27 33 71 61 50 39 34 30 36700 0.330 891 0.027 <20 51 39 29 24 21 15 <20 61 53 39 32 26 23 23 61 57 46 38 31 26 251050 0.495 1337 0.032 <20 54 41 32 25 21 17 <20 64 57 41 33 28 24 27 65 60 47 38 32 28 29

12 1400 0.661 1783 0.040 <20 55 42 34 26 22 18 <20 67 55 42 34 29 25 31 70 59 47 38 33 29 351750 0.826 2228 0.072 <20 56 44 37 27 22 18 <20 68 58 44 36 30 27 32 71 60 48 40 34 30 362100 0.991 2674 0.120 <20 58 47 39 29 23 18 <20 70 60 47 38 32 29 35 72 62 49 41 36 31 37800 0.378 748 0.019 <20 45 35 30 23 20 15 <20 60 50 37 31 26 24 22 60 57 44 37 31 27 251350 0.637 1263 0.032 <20 49 39 32 26 22 17 <20 62 50 39 33 28 26 24 64 62 45 38 33 29 31

14 1900 0.897 1777 0.048 <20 53 42 34 28 23 19 <20 64 50 41 35 29 27 27 69 62 46 39 34 31 332450 1 156 2292 0.076 <20 57 45 38 30 25 20 <20 65 52 43 36 31 28 28 70 63 48 40 35 32 353000 1.416 2806 0.116 <20 59 48 42 32 27 21 20 67 55 46 37 32 28 31 71 63 49 41 36 32 361000 0.472 716 0.015 <20 54 38 30 26 23 19 <20 63 53 38 34 29 26 26 66 55 46 38 33 29 301750 0,826 1253 0.028 <20 56 41 34 28 24 20 <20 66 54 40 36 30 27 30 68 56 47 40 35 30 32

16 2500 1.180 1790 0.036 <2C 58 44 38 31 26 21 <20 68 55 43 37 32 28 32 69 57 48 41 36 32 333250 1.534 2328 0.056 <2C 60 46 42 33 27 22 22 69 56 45 39 33 29 33 70 58 49 42 37 33 354000 1.888 2865 0.084 <2C 62 49 45 35 28 23 24 71 57 48 41 34 30 36 73 59 51 44 39 34 391300 0.613 736 0.015 <2C 53 38 33 28 24 21 <2C 62 53 39 36 33 31 24 62 58 56 40 36 35 272225 1.050 1259 0,026 <2C 56 40 33 29 25 21 <2C 64 53 41 37 34 31 27 67 57 46 41 36 34 31

18 3150 1.486 1783 0,032 <20 57 43 34 30 26 21 <2C 66 54 43 38 34 31 30 69 56 47 42 37 34 334075 1.923 2306 0,042 <20 60 46 41 32 28 22 22 68 54 45 39 35 32 32 71 58 48 43 38 34 365000 2.360 2829 0.055 <20 63 49 48 35 29 23 26 70 55 47 40 35 33 35 73 59 50 44 40 35 391600 0.755 733 0.019 <20 52 37 29 28 24 19 <2C 60 48 38 35 33 29 22 63 55 45 40 39 33 262950 1.392 1352 0.025 <20 56 41 32 29 25 21 <2C 62 48 39 36 33 29 24 66 56 46 41 39 33 30

20 4300 2.029 1971 0.032 <20 65 47 35 30 27 22 28 68 52 41 37 33 29 32 72 57 46 42 40 34 375150 2.430 2361 0.045 <20 68 51 39 32 28 23 32 72 56 44 39 34 31 37 75 60 47 43 41 36 416000 2.831 2750 0.061 <20 71 55 44 34 30 25 36 76 59 47 40 35 31 43 78 62 50 45 42 37 452250 1.062 739 0.020 <2t 54 39 29 28 24 19 <2C 61 48 38 35 33 29 23 64 55 45 40 39 33 273600 1.699 1183 0.023 <20 56 42 32 29 25 21 <20 62 48 39 36 33 29 25 66 56 46 41 39 33 30

24 4950 2.336 1626 0.028 <20 64 45 34 30 26 22 27 65 51 40 37 33 29 28 70 57 46 42 40 34 356400 3.020 2103 0.036 <20 66 49 35 31 28 23 30 70 54 42 38 34 30 35 73 58 47 43 41 35 387850 3.704 2579 0.054 <20 70 54 43 34 30 25 35 75 58 46 40 35 31 41 77 62 49 45 42 37 43

Notes:1. The performance data shown is based on tests conducted in accordance with ARI Standard 880-98 and ASHRAE Standard 130.2, Measurement of Sound Power Levels is in accordance with International Standard ISO 3741 comparison method,3, The Noise Criteria (NC) calculation is based on ARI Standard 885-98. See Table 4 for sound attenuation calculation

Right to alterations reserved,~ oLA)L.L ~iIIIS <I registered trade mark

,.y •• 'l\ ~~ - ~~ ,;~I ~ ~ ()copYrightSAFID 2009- All Rlghls Reserved

III

243

Page 8: Safid

Table 3: Static Pressure and Insertion Loss of Sound Attenuator

Right to alterations reserved.~<L....ol~ ~IS a registered trade mark

I"y •• ~ ~L..... - 4..b~ ;,..u.1~ ~ © copynght SAFID 2009 - All Rights Reserved

SVT SOO-SA: Air Terminal with Downstream Sound Attenuator

SVT 500 SeriesVAV Air Terminal UnitsSingle Duct, Pressure-Independent

SafidAir Terminals

Air Terminal Rated Air Flows Downstream Sound Attenuator

With Atlenuator Static Attenuator Attenuator Insertion Loss (dB)

Model CFM m'/s Pressure Model Size (mm) Octave Band Center Frequency, Hz

(in. w.G.) ( WxHxL) 125 250 500 1kHz 2kHz 4kHzl:>U U.UIl U.UL

250 0.118 0.04SVT 506-SA 350 0.165 0.06 SA20-100 300x300x900 12 22 37 50 46 36

450 0.212 0.10550 0.260 0.14LUU U.U94 U.UL

400 0.189 0.06SVT 508-SA 600 0.283 0.12 SA20-100 300x350x900 12 22 37 50 46 36

800 0378 0.221000 0.472 0.34400 0.189 0.02700 0.330 0.06

SVT 510-SA 1000 0.472 0.14 SA20-125 325x400x900 12 21 37 48 41 311300 0.613 0.241600 0.755 0.34(UU U.elelU U.UL

1050 0495 0.04SVT 512-SA 1400 0661 0.08 SA20-175 375x450x900 12 19 35 41 29 25

1750 0.826 0.142100 0.991 0.20tlUU U.el(tl U.UL

1350 0.637 0.04SVT 514-SA 1900 0.897 0.10 SA22-200 420x500x900 12 18 30 33 26 23

2450 1.156 0.163000 1.416 0.22lUUU U.4(L U.UL

1750 0.826 0.06SVT 516-SA 2500 1.180 0.12 SA27-200 470x550x900 12 18 30 33 26 23

3250 1.534 0.224000 1.888 0.34DUO 0.613 0.022225 1.050 0.08

SVT 518-SA 3150 1.486 0.18 SA32-200 520x600x900 12 18 30 33 26 234075 1.923 0285000 2.360 0441tiUU UJ:>:> U.U42950 1.392 0.12

SVT 520-SA 4300 2.029 0.28 SA37-200 570x650x900 12 18 30 33 26 235150 2,430 0406000 2.831 0.54LL:>U 1.UtiL U.Uel3600 1.699 0.07

SVT 524-SA 4950 2.336 0.12 SA20-175 750x670x900 13 19 35 41 29 256400 3.020 0.197850 3.704 0.29

Notes:1 Static Pressure on the above table is for sound attenuator only.2. If SVT 500 Series with downstream sound attenuator will be used, the pUblished NC levels on the Discharge Performance Datawill be reduced by 15dB. Proper size of sound attenuator shall be selected beacause it can be also a source of noise due to flow selfgenerated noise.3.To obtain the Static Pressure of SVT 500 Series with integral downstream sound attenuator. the Static Pressure of soundattenuator from the above table shall be added to the Static Pressure of the SVT 500 Series Air Terminal.4 Refer to Table 1 and Table 2 for NC levels and Static Pressure of SVT-500 Series Air Terminal

IIIIIIIIIII.mIIIIIII 244

II

Page 9: Safid

III

SafidAir TerminalsVAV Air Terminal UnitsSingle Duct, Pressure-Independent

SVT 500 Series

IIIIIIIIIIIIIIIII

Noise Criteria (NC) CalculationTable 4: Sound Attenuation Calculation as per ARI 885-98

Table 4A DISCHARGE SOUND

AR1885-98 ATTENUATION ASSUMPTION

DISCHARGE <300 CFM Octave Band Center Frequency, Hz125 250 500 1kHz 2kHz 4kHz

1. Environmental effect 2 1 0 0 0 02. Duct lining 1" thk, 15" x 15" x 5ft 2 3 9 18 17 83. Flexible duct 5ft, 0 8" 6 10 18 20 21 124. End reflection 9 5 2 0 0 05.Sound Power division ( 1 space supplied) 0 0 0 0 0 06. Space effect 5 6 7 8 9 10

Total Attenuation ( dB ) 24 25 36 46 47 30

Table 4B DISCHARGE SOUND

AR1885-98 ATTENUATION ASSUMPTION

DISCHARGE 300 - 700 CFM Octave Band Center Frequency. Hz125 250 500 1kHz 2kHz 4kHz

1. Environmental effect 2 1 0 0 0 02. Duct lining 1" thk. 15" x 15" x 5ft 2 3 9 18 17 83. Flexible duct 5ft, 0 8" 6 10 18 20 21 124. End reflection 9 5 2 0 0 05.Sound Power division ( 2 spaces supplied) 3 3 3 3 3 36. Space effect 5 6 7 8 9 10

Total Attenuation ( dB ) 27 28 39 49 50 33

Table 4C DISCHARGE SOUND

AR1885-98 ATTENUATION ASSUMPTION

DISCHARGE >700 CFM Octave Band Center Frequency, Hz125 250 500 1kHz 2kHz 4kHz

1. Environmental effect 2 1 0 0 0 02. Duct lining 1" thk, 15" x 15" x 5ft 2 3 9 18 17 83. Flexible duct 5ft, 0 8" 6 10 18 20 21 124. End reflection 9 5 2 0 0 05.Sound Power division (3 spaces supplied) 5 5 5 5 5 56. Space effect 5 6 7 8 9 10

Total Attenuation ( dB ) 29 30 41 51 52 35

Table 4D RADIATED SOUND

AR1885-98 ATTENUATION ASSUMPTION

RADIATED Octave Band Center Frequency, Hz125 250 500 1kHz 2kHz 4kHz

1. Environmental effect 2 1 0 0 0 02. Mineral tile. Space/Ceiling effect 16 18 20 26 31 36

Total Attenuation ( dB ) 18 19 20 26 31 36

Note:1. If split air flows will be supplied to the same conditioned space, the Sound Power division outlined on the abovetable has no effect. Therefore the value of Sound Power division in all frequencies from 2 to 7 (125Hz to 4kHz) isequal to zero, then the total attenuation will be less than the above calculation. Noise Criteria can be recalculatedusing the above calculation to apply the actual site conditions.

Right to alterations reserved.oi.......L..... 4......tl~ ~IS 3 registered trade mark

f"(' • , ~L..,. - .i....I.:.~ j~l~ ~ () copyright SAFID 2009 - All Rights Reserved 245

Page 10: Safid

Right to alterations reserved.~ oL...QL. ~C!lis a registered trade markf" .. C\ ~L...... - &..b~ ;,...u.1~ ~ () copynght SAFID 2009 - All Rights Reserved

The above tabular representaion of NC curves can be used to determine the new NC level whenever recalculation ofdischarge or radiated NC level is required

Octave Band Center Frequency, Hz

NC 2 3 4 5 6 7(125 ) (250 ) (500 ) (1 kHz) (2 kHz) (4 kHz)

15 36 29 22 17 14 12

20 40 33 26 22 19 17

25 44 37 31 27 24 22

30 48 41 35 31 29 28

35 52 45 40 36 34 33

40 56 50 45 41 39 38

45 60 54 49 46 44 43

50 64 58 54 51 49 48

55 67 62 58 56 54 53

60 71 67 63 61 59 58

65 75 71 68 66 64 63

SVT 500 Series

Note:

Noise Criteria (NC) Calculation

Table 5: Tabular Representation of NC Curves, dB

VAV Air Terminal UnitsSingle Duct, Pressure-Independent

SafidAir TerminalsIIIIIIIIIII.­IIIIIII 246

II

Page 11: Safid

IIII

SafidAir TerminalsVAV Air Terminal UnitsSingle Duct, Pressure-Independent

Flow Calibration Chart

SVT 500 Series

IIIIIIIIIIIIIIIII

SArlO 'SVT50o- FLOIN PROBE [FM vis PRESSURE GRAPH

Ie

lODO 10188

388~

7 7(28---l~ ~.'0 :.-- 6012 <I:

~..... z

....... .......v ~I--- ~4638 ~

-"0~ V -- V:'--

Vl

..... 3526

JOO1l1---:.--

2888 :r:

'""' ~V~ v ~ u

L .....~ I--- ' . ~v -- I--- ~L..- 2000

I~ ~u .......- ~ I--- -- 1689 W~

I~OO

[:::: .....~~V

z

~:.--

j....--vi-- 0

:3 ..... I--- Ill)lllD @J

0 a-' :L

L..- 1>00 ~q~L

--- -- ~ --- ~ uCL: Sao<[ --- .,'~........ --~

..... ,--"I--- --'00~ ",~,~.....~

20.2no -- ..... :.--l..-V.......IDa

~8060

"20lOa

~ ~...

:il ;; ~...

~ ~ ~ -D 0 Q

FLOIN PROBE DIFFERENT[AL PRESSURE (L".P) IN ING

Airflow Range

MODEL UNIT SIZE INLET SIZE K Inlet Area Airflow Range (CFM)( inhces ) DrA (mm) Factor fP Min Heating Max

SVT 506 6 152 1.79 0.20 60 138 550SVT 508 8 200 1.58 0.35 110 250 1000SVT 510 10 250 1.70 0.55 170 400 1600SVT 512 12 305 1.20 0.79 290 525 2100SVT 514 14 350 1.48 1.07 352 750 3000SVT 516 16 400 1.46 1.40 464 1000 4000SVT 518 18 450 1.39 1.77 600 1250 5000SVT 520 20 500 1.50 2.18 710 1500 6000SVT 524 24 600 1.52 3.14 1020 1950 7850

Note:Maximum Airflow is based on 3000 FPM inlet velocity.At Heat mode minimum 0.03"WG discharge pressure is required to energize flow switch.

Right to alterations reserved..L...L......... <L-o)I....L ~«lIS a registered trade mark

f Y •• '\ ~L.... - 4...Jo~ j,...LJ.1~ ~ e copyright SAFID 2009 - All Rights Reserved 247

Page 12: Safid

III

SafidAir TerminalsVAV Air Terminal UnitsSingle Duct, Pressure-Independent

SVT 500 Series

IIIIIIIIIIIIIIIIII

SVT 500-EH: Air Terminals with Downstream Electric Heater

Optional Electric Heaters

OPTION NO.2 - Open Coil:

Construction:The open coil type heating element is made from a high grade resistance wire. Each heating coil elementis designed to the customer's wattage specification. A gauge heavier than a normal gauge wire is used,giving a longer coil to maintain the required resistance for a given wattage.

The casing is made from galvanized steel sheet as standard. Optional casing can be made fromaluminized or stainless steel.

Basic Electric Heater, Code EHO:1. The basic electric heater have no built-in temperature regulation controller.2. In case of thermal over load, it has two built-in over heating protections, one is automatic reset and theother one is to be manually reset.3. The basic electric heater have a built-in air flow switch to detect the presence of air flow passingthrough the electric heater. The power supply to the electric heater must be interrupted if the supply fan orair flow stopped.4. The number of kW steps is available from 1 to 3 steps.5. The power supply available is 230V/1 PH/60HZ or 440V/3PH/60HZ.6. The maximum kW rating is 200kW.

Electric Heater with built-in solid state proportional controller, Code EHOS1. The heating element is controlled simultaneously with the built-in solid state controller. The built-incontroller is made for an external 0-10 VDC control signal from BMS.2. It has also a built-in automatic and manual reset over heating protection and air flow switch to detect thepresence of air flow passing through the electric heater.3. The power supply available is 230V/1 PH/60HZ or 440V/3PH/60HZ.4. The maximum kW rating is 200kW.

Note: For more details, please see Duct Heater catalog on chapter 11.

Right to alterations reserved.~ .........~ ~I!lIS a regIstered trade mark

f' Y •• " ~L... - .u::,~ j,..oJ.1~ ~ (l copyright SAFID 2009 - All Rights Reserved

m

249

Page 13: Safid

Right to alterations reserved..L...L..........i.-..4L. ~C1IS a registered !fade mark

~ I •• ~...,..L.. - .u,~ J,.ul~ ~ © copyright SAFID 2009 - All Righls Reserved

Heating Mode:During winter, the room thermostat signals the damper actuator to regulate the damper position atminimum air flow. lNhen the room temperature continuous to fall below the temperature set-point, theroom thermostat will energize the electric heater while the damper position will be at minimum air flow.

~®~

Air FlowCoolng

__+1- MaxiMuM

SVT 500 Series

CODLING

---:-------1- Mi n iM UM

f--Heo. tingI Set-pointI

CoolingSet-pain -----7

\\

\\

\\

ROOM TeMpero.ture

\\

\\

\

HEAT[ G

Air FlowHeo. ting

o

Cool

MiniMUM

MaxiMUM -

Cooling Mode:During summer, the room thermostat signals the damper actuator to regulate the damper position. Thecooling set-point decide the room temperature. lNhen the room temperature rises above the cooling set­point, the damper will be modulated to maximum air flow. lNhen the room temperature fall below thecooling set-point, the damper will be modulated to minimum air flow.

Controls Sequence

VAV Air Terminal UnitsSingle Duct, Pressure-Independent

SafidAir TerminalsIIIIIIIIIII.1lIIIIIIII 252

II

Page 14: Safid

IIIII

SafidAir TerminalsVAV Air Terminal UnitsSingle Duct, Pressure-Independent

Selection of Air Terminal Size

Selection Procedure:

Example No.1:

SVT 500 Series

IIIIIIIIIIIIIIII

Customer requirements:

1. Space (room) supplied = 3 spaces2. Cooling only application3. Maximum cooling air flow (Vnom) = 1750 CFM4. Inlet static pressure at fully open damper (minimum S.P.) = 0.1 in. W.G.5. Maximum system static pressure setting =2 in. W.G.6. Maximum NC level = NC 35

From Performance Data, Table 1:

1. Select Inlet Size 12 from Table 1 which has a minimum static pressure of 0.072 in. W.G. at 1750 CFM.The value of the selected minimum static pressure shall not exceed the required minimum static pressureof 0.1 in. W.G.2. The NC levels in Table 1 were calculated using Table-4C as per ARI 885-98 where above 700 CFM,the sound power division supplied 3 spaces. The discharge NC level from Table 1 at 2 in. W.G. S.P. isNC 33 and the radiated NC level from Table 2 is NC 32.

SVT 512 ( Inlet Size 12) will meet the required pressure drop (less than 0.1 in W.G.) and NC level (NC 35)for this example.

Example No.2:

Customer requirements:

1. Space (room) supplied = 1 space2. Cooling only application3. Maximum cooling air flow (Vnom) =1750 CFM4. Inlet static pressure at fully open damper (minimum S.P.) =0.1 in. W.G.5. Maximum system static pressure setting = 2 in. W.G.6. Maximum NC Level = NC 35

From Performance Data Table 1:

Since the published NC levels for Inlet Size 12 at 1750 CFM were calculated as supplied 3 spaces whilethe actual customer requirement is to be supplied 1 space only, recalculation of Noise Criteria (NC) usingTable 4A is required.

1. Selecting Inlet Size 14 from Table 1, the minimum static pressure at 1750 CFM by interpolation is 0.044in. w.G.2. By interpolation and recalculation using Table 4A, the discharge NC level at 1750 CFM is NC 35 and theradiated NC level from Table 2 is NC 27.

SVT 514 (Inlet Size 14) will meet the required pressure drop (less than 0.1 in W.G.) and NC level (NC 35)for this example.

Right to alterations reserved.4.......L...... ~':.l...c. ~I!lIS a registered trade mark

~Y •• ., ~L... - Lb~ j,..u.1~ ~ () copynght SAFID 2009 - All Rights Reserved 253

Page 15: Safid

Right to alterations reserved.~ oLAL. ~(!lis a registered trade mark

r'" ., ~L... - 4...L~ j~1~ ~ tV copyright SAFID 2009 - All Rights Reserved

Order Code: SVT ~~ l>~f~ ~~ ~e ff .Q 9 1111 ji ." kk II !!1..m~ ""'

Model No:

506:: Inlet Size NO.6508:: Inlet Size No.8510:: Inlet Size No. 10512:: Inlet Size No. 12514 =Inlet Size No. 14516 =Inlet Size No. 16518 =Inlet Size No. 18520:: Inlet Size No. 20

Options:

SA =With discharge sound attenuatorOP :: With multiple outlet plenumEHT :: With stainless steel tube coil electric heaterEHTR ::With stainless steel tube coil electric heater and -

built-in temperature regulation controller powered byexternal 0-10V control signal from a BMS or similar.

EHO :: With open coil electric heaterEHOS :: With open coil electric heater and built-in

solid state proportional controller powered by external0-10V control signal from a BMS or similar.

HW =With discharge hot water coilkW:: Power rating of electric heater1, 2, 3 :: Required number of stepsM :: With Belimo actuator/controllerTC :: With digital room temperature controllerT:: With step-down transformer from 220V to 24V for actuator/controller -TB :: With terminal block for transformerCB :: With control boxP :: With perforated sheet behind acoustic liningSF:: With slide on flange on discharge sideFC :: With flexible connector

Air Flow Setting:

CFM = Vmax ( % maximum airflow setting of Vnom )CFM :: Vmin ( % airflow setting based on Vmax )

NOTES:1. If the discharge side connection is not specified. slip & drive is the standard connection.2. If the actuator/controller, transformer, terminal block and control box is not specified, the standard

supply is with extended shaft only for actuator/controller connection.

IIIIIIIIIII.mIIIIIII 254

II

SafidAir TerminalsVAV Air Terminal UnitsSingle Duct, Pressure-Independent

Order Details

SVT 500 Series

Page 16: Safid

IIII

SafidAir TerminalsVAV Air Terminal UnitsSingle Duct, Pressure-Independent

Order Example

SVT 500 Series

IIIIIIIIIIIIIIIII

Example NO.1 :

Requirements :Variable Air Volume Air Terminal, Pressure-Independent capable of delivering 1750 CFM (Vnom) at 0.05in. W.G. minimum static pressure at fully open damper blade and with maximum discharge NC 35 at 2 in.W.G. maximum system static pressure setting. Maximum air flow (Vmax) is 100% of Vnom and minimumair flow (Vmin of Vmax) is 30%. Air Terminal should be with Belimo actuator/controller and control box.The space supplied is one room only.

Selected Model: SVT 514 - By interpolation and recalculation using Table 4A, SVT 514 will meet therequired 0.05 in. w.G. pressure drop and the discharge NC 35 at 2 in. W.GStatic Pressure.

Ordering:Make : SAFIDType : SVT 514 - M - CB - 1750CFM - 525CFMQty. : 1 pc

Example NO.2 :

Requirements:Same as Example NO.1 but with discharge Sound Attenuator at Inlet & Attenuator static pressure of 0.15in. w.G.

Selected Model: SVT 514

Ordering:Make : SAFIDType : SVT 514 - SA - M - CB -1750CFM - 525CFMQty. : 1 pc

Example NO.3 :

Requirements:

Same as Example NO.1 but with open coil electric heater, 3kW, 1 step.

Selected Model: SVT 514

Ordering:Make : SAFIDType : SVT 514 - EHO - 3kW - 1 - M - CB - 1750CFM - 525CFMQty. : 1 pc

Example NO.4 :

Requirements:Same as Example No.1 but with open coil electric heater, 6kW, 2 steps with digital room temperaturecontroller.

Selected Model: SVT 514

Ordering:Make : SAFID

Type : SVT 514 - EHO - 6kW - 2 - M - TC- CB - 1750CFM - 525CFMQty. : 1 pc

Right to alterations reserved.~ <l....cl)l....(. ~IS a registered trade mark

f"(' • ., yL... _.i...b~ .;,..u.1~ ~ () copyright SAFID 2009 - All Rights Reserved 255

Page 17: Safid

Duct Heaters III--

IIIIIIII,IIIIIt9IIIIIII

Air Devices & Terminals

Right to alterations reserved."~.L...>".l...L ~lJI)IS a registered trade mark

I" 'Y •• "l -'-!jL.., - ......bt--4--.......cl j,...,a-.tl~ l4:j © copyright SAFID 2009 - All Rights Reserved 289

Page 18: Safid

SafidDuct HeatersIIIIIII

..IIIII~

IIII

Contents

Type Page

1£. EHOEHT 292EHFT

Type Page

I 290

II

Right to alterations reserved.~~)l....c. ~l!IIS a registered trade mark

~ "( •• ., ->...;-~L..... - .i.L~ j,....,..J.1~ ~ © copyrIght SAFID 2009 . All Rights Reserved

Page 19: Safid

IIIIIII

I­IIIII

--IIIIIII

SafidDuct Heaters IZrElectric Duct Heaters EHO, EHT & EHFT Series

General Information

SAFID Electric Duct Heaters series "EHO", "EHT" & "EHFT" are designed for a trouble free operation at acompetitive price We designed these heaters for easy installation into a duct either in Slip-in Insert Type or inFlanged Type as to meet with the project requirements Safid can manufacture the Duct Heaters with any size,capacity, power supply and optional controls / accessories as per the project requirement and according to thespecifications here under Most of our products are custom designed, so that you can meet these products with yourproject specification with a competitive price and trusted years of operation

Description

Duct heaters are primarily use as a source for space heating Duct heaters are self contained and designed to installin a duct system either in a horizontal or vertical duct It can be installed as a stand alone or combined with anysource of heating and cooling systems SAFID Heaters can be use as for primary heating, secondary heating,auxiliary heating, reheat and humidity control or multi zone with VAV systems to meet the maximum comfortconditions SAFID duct heaters are custom engineered and designed with the help of our newly developed ComputerSoftware packages which will specify the element size, sheet metal, support racks with Insulators, controls,configuration and all optional accessories This software will allow us to prepare an immediate custom design orquotation and it will help to any design changes or modification of controls without any delay

As standard, SAFID Duct Heaters are manufacturing with the following specifications and components You canselect the optional controls in accordance with the project specifications and requirements Please contact SAFID formore information you may required

1 1mm thick galvanized steel casing with NEMA-1 type control panel2 De-energizing type magnetic contactor per each steps3 Class-II type Step down Control Transformer4 Auto reset thermal cut-out (Disc Type)5 Manual reset thermal cut-out (Disc Type)6 Differential Airflow SWitch7. Teminal blocks for power & Controls cable termination8. Type - A, 80/20 Nickel/Chromium alloy wireg Stainless steel tube for "EHT" series.

1O. Stainless steel tube & Fins for "EHFT" series,

In addition of the above standard package a variety of optional controls and designs are available to choose for thesuitable one to you Please refer the attached for the type of optional controls and designs available in SAFID

Right to alterations reserved..L...L........,.. .... <L..... L ~I!lIS a registered trade mark

t ~ .. "I ......~L ... - 4..bt-.:a_~ J,....J.I~ ~ © cop'frlght SAFID 2009 - All Rights Reserved 291

Page 20: Safid

DescriptionOpen Coil Series "EHO"

SafidDuct Heaters 1Zl®EHO, EHT & EHFT SeriesElectric Duct Heaters

II

II

IIIIeIII Tubular Coil Series "EHT"

SAFID Electric Duct Heaters "EHO" series Open Coilduct heaters are very rugged and efficient ductmounting type air heaters They are designed to heatlarge volume of air in ducts based on capacity "EHO"series Open coil duct heaters are designed with verylow air pressure drops across the heaters This willallow to select and install smaller and more economicalblowers due to duct heaters low pressure drop and itwill be more effcient

The open frame duct heaters have a long history oftrouble free operation in field. The inherent efficiency ofthe "EHO" series design assures that exessivetemperatures don't built up in the heater to shorten itslife Since the heater is so open, it does not obstruct ortax the overall air delivery system These heaters areessentially very competent, since the circuits are opendirectly to the airflow This case the heat transfer fromwire to air is direct and immediate As a result theseheaters give their heat read illy to the air and remaincool themselves which offer long life for heaterelements Fast warm up and cool down times areinherent advantage of this construction

Description

I Finned Tubular Coil Series "EHFT"

SAFID ElectriC Duct Heater "EHT" series duct heatersare with Tubular Heater elements The heat resistancecoils are passing through a Magnesium filled StamlessSteel Tube and Coil ends are fitted with hightemperature rated ceramics

Description

IIII 292

SAFID Electric Duct Heater "EHFT" senes duct heatersare With Finned Tubular Heater elements The heatresistance Calls are passing through a Magnesium filledStainless Steel Tube and coil ends are fitted with hightemperature rated ceramics Tubes are fitted withStainless steel fins

Right to alterations reserved..i~ .l-I>'x...... ~l!lIS a registered trade 11ark

r'''' . 'l, ..>..,...,ll_ - ~~_'-"ol .n....-~I ~~ I~..!!!l €I cooyflght SAFID 2009· 1\11 Rights Reserved

II

Page 21: Safid

III

SafidDuct Heaters IZI®Electric Duct Heaters EHO, EHT & EHFT Series

II

Construction Details

1. Slip-in Insert Type

These are most commonly used type due to its simple installation It can be inserted in to a duct from the side bycutting an opening to match with the heater size and fastened by mettallic screws thru inside the control panel. In thistype of installation, the heater height is overlapped by 25mm than the element enclosure. so the panel will cover allrough opening in duct.

II

~.III

INSERT TYPE

, CONTROL PANEL

FASfENTNGSCREWS

INSERT TYPE INSTALLATION

2. Flanged Type

>

CONTROL PANEL

DUCT

II1-II

This type of installation provides maximum duct rigidity. Heater has to be installed in between two ducts by means ofjoining the flanges in ducts and heater Element enclosures inside dimensions are same as the opening size ofducts. 25mm flanges are provided in heater as standard unless otherwise specified All flanges are to be joined withproper bolts & nuts to secure the heater in between the duct and fastened by metallic screws through the controlpanel

II

FLANGED TYPE FLANGEDTYPE INSTALLATION

IRight to alterations reserved.~ .......,'L. ~~IS a registered trade mark

f'''' .. ~ ~L..., - o1.k~ jo.....>.-ll~ ~ © copyright SAFID 2009 All Rights Reserved 293

II

Page 22: Safid

IIIIIII

I-IIIII

I'IIIII 294

II

SafidDuct Heaters IZrElectric Duct Heaters EHO, EHT & EHFT Series

Construction Details

3. Recessed Type

W= Duct WidthH= Duct HeightK= 2 Times Insulation Thicknessp= Insulation Thickness

RECESSED TYPE

This type of installation is suitable for internally insulated ducts where other obstructions restrict the full duct facearea The recessed panel is designed to project beyond the insulation, so that the element termination and thermalcut-out surfaces are exposed in airflow The depth of the recessed panel will be depends the internal insulationthickness.

4. Bottom Terminal Box

TERMINAi_ BDX

This type of designs are allow the heater installation by bottom where the space restriction is for side mounting Thiswill provide maximum ease of serviceability in limited space Element termination and thermal limits cut-outs areinstalled in side terminal box and remaining controls except Mercury Contactors, SCR Controls and Power Fusing arebuilt in bottom control panel SCR Controller, Mercury Controller and Power Fusing are to be installed in separateremote control panel

Right to alterations reserved.~ 4,.Jl)LL ~~IS. a registered trC\de marl<

t" .. '\ ~L.." - 4.bT"-~ ~t--l-ll ~ ~ © copyright SAFID 2009 - All RIghts Reserved

Page 23: Safid

III

SafidDuct Heaters IZI®Electric Duct Heaters EHO, EHT & EHFT Series

I Heater Element Design

III

As standard all 8AFID open coil heaters "EHO" series are built with Type - A. 80% Nickel I 20% Chromium hightemperature alloy resistance heating elements These elements are designed to operate with maximum 55 watts persquare inch and below than the maximum allowable operating temperature recommended by the alloy manufacturerThis unique design eliminates most problems with hot spots and red color caused by poor airflow pattern It will alsoincrease the life of heating elements and guaranteed a trouble free operation

These elements are passing through high quality anti thermal shock. moisture resistant steatite cylindrical bushingceramics Ceramics are free floating within wire support and eliminating any binding Ceramics and heating elementsare supported by corrosion resistant heavy gauge steel rod construction and rods are welded or bolted in betweenand with the control panel This design allows for free flow of air around the ceramics and reducing the pressure dropthrough element and supports

-­I

8AFID Tubular Duct Heaters series "EHT" are manufactured with stainless steel tube heater elements Type - A80/20 Nichrome wire precisely centered in a Magnesium filled 88316 tube and element is welded to a 10-32 88 pinterminal for field electric termination

8AFID Finned Tubular Duct Heaters series "EHFT" are manufactured with stainless steel tube & fins heaterelements. Type - A 80/20 Nichrome wire precisely centered in a Magnesium filled 88316 tube and element is weldedto a 10-32 88 pin terminal for field electric termination Tubes are wounded with 88304 hellical fins for maximumheat transfer

I

Finned Tubular HeaterTubular HeaterOpen Coil Heater

II

II'IIIII 296

Right to alterations reserved.<l..~ <L.e'.L.L ~l!lIS a registered trade mark

r' Y •• ., ~L..... - <l..b~ -,~I t-- l~ © copyright SAFIO 2009 - All Rights Reser....ed

II

Page 24: Safid

Electric Duct Heaters

IIIIIIIIeIIIII~

IIIIIII

SafidDuct Heaters IZI®EHO, EHT & EHFT Series

Engineering Informations

UL & NEe Requirements

The design and installation of electric duct heater must conform all Local and National Standards and regulations inaddition to the below requirements The below listed informations are offered as a guideline for electric duct heatersand it is based on UL & NEC space heating standards

1 Over Temperature Protection: UL & NEC requires the manufacturer to provide two types of over temperatureprotection As standard all SAFID duct heaters are supplied with one Primary and one Secondary thermal cut-outs tocomply with this requirement Disc type Auto reset thermal limit sWitch de-energize the heater control circuit in theevent of an over temperature occur and work as a primary protection Disc type Manual reset cut-out will work assecondary protection incase of failure primary limit sWitch and It IS rated for higher temperature than primary cut-out

2 Over Current Protection: UL & NEC require that a heater in excess of total 48 ampere must be subdivided intonumber of circuits having less than 48 ampere and protected by built in Fuses or Circuit breakers and this overcurrent protection must be rated for 125% of the circuit load SAFID comply this requirements with fuses when andrequired Fuses and Circuit breakers are optional for all duct heaters except the above conditions

3 loss of Airflow Protection: UL & NEC require that a method to be provided to prevent the duct heater elementfrom being energized unless the fan circuit IS on and airflow is available in duct To comply this all SAFID ductheaters are equipped with built in deferential airflow switch as standard In addition we can provide optional faninterlock relay or volt free contacts for fan connection to meet thiS requirement

4 Transformer Protection: Control transformers are required for heater operation unless an external controlvoltage source IS available and the heater supply voltage is dfferent from the control voltage This transformer shouldbe with primary over current protection Generally Class-II transformers are with built in over current protection andothers have to protect with separate fusing Secondary protection is available as an option and it is not necessary byUL

5 Contactors: UL require that built in contactor is reqUired to on-off the circuits in each heaters SAFID provide de­energizing type magnetic contactors as standard for all our duct heaters to comply with this requirementDisconnecting Type and Mercury Contactors are optional

6 Disconnect Means: As per NEC, an equipment disconnect switch to be Installed as built in or within the sight ofthe heater, SAFID offer an optional door interlock or non interlock type of disconnect switch as built In or separate forfield installation to meet this

7 Grounding Lugs: UL requires a built in grounding lug to be installed for field winng terminations All SAFIDheaters built in grounding lugs to comply this requirement

Right to alteratIOns reserved,~<l,,~~ ~@IS a registered frade marK.

f>"" • ~ .........aL..... - ..J...,~......... j!'...d l ~ ....." I~~ © copyright SAFID 2009 All Rights Reserved

III

297

Page 25: Safid

The minimum airflow across the electricheater is directly related to the inlet airtemperature Consideration must be givento both airflow across the electric heaterand the inlet air temperature

To calculate the watts per square foot(watts/sq ft) of duct area, divide the totalrequired watts by the duct cross sectionalarea

The velocity across the electric heatershould never be lower than the determinedvelocity from the chart

To determine the minimum air velocityacross the electric heater. draw a horizontalline from the required watts/sq ft up to thedesigned inlet air temperature line Fromthis point of intersection on the inlettemperature line. draw a vertical line toestablish the air velocity

The air velocity across the electric heatermust be minimum 1.5 mls to give a surfacetemperature of the heating elements ofabout 300-350 degrees Celsius.

--+------

1-1-1­

1-+-.....

I-f-t-

. ,-+-1-1-+ I­

-1-1­I-

I-

l--+:-;:::r

,-f-

:-r-I­-I-

t I--f-

200 400 600 800 1000 1200 1400

AIR VELOCITY - FPM

Finned Tubular ElementsUn Finned Tubular Elements

T I- ..J-..-+- I­P-,-l-l--

o 200 400 600 800 1000 1200 1400

AIR VELOCITY - FPM

o

2

----- BELOW 78°F INLET AIR7B"'F TO gO°F INL.ET AIR

91"'.= TO 100"F tNLE.rAIR

2

16

18

Right to alterations reserved.~ J.....c'}L, ~«lIS a registered trade mark

~ y •• l\ ........ L..... - ....L~ .,~I ~ ~ © copyright SA~ID 2009 - All Rights Reserved

4

14I­lU~ 12lUoc~ 10oenoc 8wa.~ 6

l.UCL

= 6

4 l---l.--r1--,- 'r-r

Minimum Air Velocity For Electric Duct Heate,r

Minimum Air Velocities For Open Coil Terminal . --:~1

Minumum Air Velocities For Finned & Unfinned Coil Heater

SafidDuct Heaters IZrElectric Duct Heaters EHO, EHT & EHFT Series

IIIIIII

--IIIII

-IIIII 298

II

Page 26: Safid

Electric Duct Heaters

III

SafidDuct Heaters ~rEHO, EHT & EHFT Series

II

Temperature Rise Chart & Pressure Drop

Temperature Rise Chart

... .' ~' v

I:~

/ / /'

+/ :/ /'

'1-,.",1.«

, "A

~I ' -> /'-/-,1 <§' /'I '

--~.-.' I 'f ~.;).; 1/

"

-/, ..~ ..,.y. /

'i / A Y ---- ---.}-/... / /'1.U• ~

~.

/ -- /I /:/ ,

/' ~~

~A / -' .v-~-

,I--r-t-r. ../;/ y ---VII .% ::-1-' --/J'I/ '/ ,- _c l---'"

I~~....-r .".f'''~~\S

'-1=+-; I-~ ---'",1'/' ----

II

-­II

2S24

23

2221

2019\K

17,.t- 15

tt: l4.... 13

~ 12

~ IIg 10

'" 9wD. K

~ 7(0

54

J2I

J 00 300 500 700 1000 \200 1500 1700 200

Temperature rise of a duct heater is animportant factor in the selection of ductheater. By this chart you can calculate theapproximate temperature rise if you knowthe airflow and heater capacity used

Draw a line vertically up from the requiredair velocity on the bottom scale up to thedesign temperature rise line From thatpoint, draw a horizontal line to the left sidescale to know the required heater capacityper square feet of duct area to maintain therequired temperature rise at design airvelocity

IAIR VELOCITY IN FPM

Pressure Drop Across Open Coil Heater

Notes:1 G) C~ @ C4) - are the number of rows of heater elements2 The pressure drop that can be selected from the above graph is for the electric heater only

y - p'.\Al v LD

The pressure drop across the electricn1(, heater depends on the air velocity and the

CL U 14 number of rows of heating coils.

-U12~ <;- If the number of rows of heating coils is

c ):( 10 unknown, assume 4 rows for the selection

u.J "-cr. 0 :J 08~v') (/)

ODE,if, L.."W I~ LJ 004:J_ Z

002

I

-I

IIIII

Right to alterations reserved.d-L.....~ ..\......Q'lLL rf!@IS a registered trade mark

~.,. •• 'i ~L..., - ~T"'---'--4 j~_-ll~... ~ © copynght SAFID 2009· All Rights Reselved 299

II

Page 27: Safid

III

SafidDuct Heaters IZI@Electric Duct Heaters EHO, EHT & EHFT Series

Pressure Drop

Pressure Drop For Tubular Coil HeaterIIII

-­II

"0 ---,-.y-

028

026 ....-+--.,

;.>" - +

r.-i'

'J 20, i

I

I~I

OIlS -,-014

012 f-lO

BJ.

( .~

.:~~,....

t- +- ,-""'vi'"

"" ~ '" g g '" c- o<:> <:;) "" -

The pressure drop across the electricheater depends on the air velocity and thenumber of installed heating coils of theheater

The Pressure drop shown is for 2 rows ofelements

Very low pressure drop Fast heat transferring More heater capacity per area Quick responsetime, Quick manufacturing & fast delivery

Open Coil:

Tubular Coil:

Disadvantages: Not suitable for dusty & high humidity environments due to direct contact with air Chance todamage the coils during maintanance or service period

Advantages:

Major Advantages and Disadvantages Of CoilsIII

--I

Advantages: Compare to open coil, less sensitive to dust & humidity environments Elements are enclosed type.Excellent mechanical resistance Shock proof construction Can be replace easily More strongerthan open coils

IDisadvantages: Pressure drop is higher than open coil, Slow response Manufacturing time is more compare to

open coil Less heater capacity per area

Finned Tubular Coil:

Disadvantages: Pressure drop is higher. Slow response Manufacturing time is more compare to open coil Lessheater capacity per area.

II

Advantages: Compare to open coil less sensitive to dust & humidity environments Elements are enclosed typeExcellent mechanical resistance. Shock proof construction Can be replace easily More strongerthan open coils Good controllability.

I 300Right to alteraUons reserved,~~'.LL ~IS a registered trade marK

~.,. , . ., yl...... ....b:,l--"-~ ~~I ~<'-> ~ © copyright SAF"ID 2009 All RlgllLs Rcsel'led

II

Page 28: Safid

III

SafidDuct Heaters lZ]®Electric Duct Heaters EHO, EHT & EHFT Series

I Contactor Wiring Configurations

ITYPICAL CONTACTOR POWER CIRCUITRY

DE-ENERGIZING CONTACTOR DISCONNECTING CONTACTOR

SINGLE PHASE - SINGLE LINE BREAK

THREE PHASE - TWO LINE BREAK

CONTACTOR

Heater is de-energized by breaking only one powerline through the action of single contact. By openingthe contactor contacts the undergrounded line wouldbe disconnected from single phase power supply

THREE 0---- j,1 i-'---G-v'V'v'v~/1PHASE o----L-l---O-NNv-~--« ~SUPPLY , I ~,'1.t-, S

0----+-:1 ~j_--~~.':\QWYE DELTA

III

HEATINGELEMENTS

CONTACTOR

>------<>--1~.j..--- -<;>

I-----~-----

FOUR WIRE "WYE" [OPTIONAL)CONTACTOR

=---1<>- ~-==-~;--.--- +=---; t->-I-~

THREE PHASE-THREE LINE BREAKCONTACTOR

>- -----+-1~, I -J"- - --,.0- I ,c....oL--

-+r-J :.J--~I

SINGLEPHASESUPPLY

Heater power supply is completely disconnected byopening all side of the contactor contacts Allundergrounded power conductors are disconnected

WYE DELTA

Heater power supply is completely disconnected byopening both side of the contactor contacts Allundergrounded power conductors are disconnected

SINGLE PHASE - TWO LINE BREAK

THREEPHASESUPPLYFOURWIRENEUTRAL

In this configuration, each element may be operatedindependently through individual contacts A threepole Disconnecting contactor must be used to openall elements from power supply

THREEPHASESUPPLY

HEATINGELEMENTS

CONTACTOR

o---'--+~-Q'-- :';

----..-...----l

Above shown is for a two line break which willde-energize the heater Heating elements those usedin three phase balanced configurations are factorywired as manufacturers standard in two basicconfigurations either in Delta or in Wye Generalstandard is Delta connection

SINGLEPHASESUPPLY

II

-­IIIII

--IIII

HEATING ELEMENT WIRING CONFIGURATIONS AND PROPERTIESSINGLE PHASE THREE PHASE

L1~ _L1----__

111

L2~.---'J~LI

I 386v/~~lSbv

j L2 -I380V I· 1 ..(

3SQV '12 J V I 3SpV nov i38rV lltDV

I I r Z20V j

J LJ I

u-' ! ! :. !L2LJ

Element Vol1aye 220V I= Element Vollage = Line Voltage Element Vollage = Line Vollage .. -- , . I

Line Vollage1.73

Elemenl Vollage =Line Voltage

Heater Current :::; WATTS Heater Currenl :::; WATTS 1.731.73 x VOLTS 1.73 x VOLTS

Healer Current = WATTS

Heater CUHont ::: Voltage between any two Vol1age between any two 1.73 x VOLTS

WATTS power leg is equel 10 3 power leg is equel to 3 Vallage between any power lug andVOLTS Phase Line Vollage Phase Line Vallage Neulral (N) = Line Voltage I 1.73

IRight to alterations reserved.~ -..:.'L..::. ~<!IIS a registered trade mark

t" , . ~ ~l. .... - ili9-11 --"-" j,....J1 t-4-> ~ © copyright SAFIO 2009 . All Rights Reserved 301

II

Page 29: Safid

IIIIIIIIeIIIII

--IIIII 306

II

SafidDuct Heaters IZI®Electric Duct Heaters EHO, EHT & EHFT Series

BTU/h - KW I Ampere Chart

BTU/h KW 120 208 220 240 277 380 415 440 460 480 KW10 10 30 10 30 10 30 10 30 30 30 30 30

3413 1 83 4.8 28 4.5 26 42 2.4 3.6 15 14 1.3 1.3 12 1

6826 2 16.7 96 55 91 52 83 4.8 72 30 28 26 25 2.4 2

10239 3 250 144 83 136 79 12.5 72 108 46 42 39 3.8 3.6 3

13652 4 33.3 192 111 18.2 10.5 166 9.6 144 61 5.6 5.2 5.0 48 4

17065 5 417 240 139 227 131 208 120 181 76 70 6.6 63 60 5

204'78 6 500 28.9 16.6 27.2 15.7 250 144 21.7 9.1 83 79 75 72 6

23891 7 583 337 194 318 183 291 168 253 106 97 92 88 84 7

27304 8 666 38.5 222 363 210 333 192 28.9 122 11 1 10.5 100 96 8

30717 9 750 433 249 409 236 374 216 325 137 12.5 11.8 113 10.8 9

34130 10 833 48.1 27.7 454 262 416 24.0 361 152 139 131 125 12.0 10

37543 11 91.6 52.9 305 499 288 45.8 26.4 397 167 153 144 138 132 11

40956 12 1000 577 332 545 314 499 288 433 182 167 157 15.0 144 12

44369 13 1083 625 360 590 341 541 31 2 469 198 181 170 163 156 13

47782 14 1166 67.3 38.8 636 367 582 336 505 21.3 19.5 183 175 168 14

51195 15 1250 72.1 416 681 393 624 360 542 228 209 197 186 180 15

54608 16 1333 769 44.3 726 41.9 666 384 578 243 223 210 200 192 16

58021 17 1416 818 47.1 772 44.5 707 40.8 614 258 237 223 21.3 20.4 17

61434 18 1500 86.5 499 817 472 749 43.2 650 273 25.0 23.6 225 216 18

64847 19 1583 914 526 86.3 498 790 456 686 28.8 264 249 23.8 228 19

68260 20 1666 962 554 908 524 832 480 722 304 278 262 250 240 20

71673 21 1749 1010 58.2 953 550 874 504 758 319 292 275 26.3 252 21

75086 22 183.3 1058 60.9 99.9 576 91.5 52.8 794 33.4 30.6 28.8 27.5 264 22

78499 23 1916 110.6 637 104.4 603 957 552 830 349 320 301 288 276 23

81912 24 200.0 1154 665 1090 629 998 576 866 365 33.4 314 30.0 288 24

85325 25 2083 1202 69.3 1135 655 1040 600 903 38.0 34.8 328 313 300 25

88738 26 2186 1251 720 118.0 68.1 108.2 624 939 39.5 36.2 341 32.5 312 26

92151 27 2250 1299 748 1226 707 1123 648 975 410 376 354 338 324· 27

95564 28 233.3 1347 776 1271 734 1165 672 101 1 42.5 390 36.7 35.0 336 28

98977 29 2416 1395 803 1317 760 1206 696 1047 441 40.3 380 363 348 29

102390 30 2500 144.3 83.1 136.2 78.6 1248 720 1083 45.6 41.7 39.3 37.5 36.0 30

105803 31 2583 1491 85.9 1407 812 1290 744 1119 471 431 406 388 372 31

109216 32 2666 153.9 88.6 145.3 838 1331 768 1155 486 44.5 419 40.0 38.4 32

112629 33 2750 1587 914 1498 865 1373 792 1191 501 459 432 41.3 39.6 33

116042 34 283.3 163.5 94.2 154.4 89.1 1414 816 1227 517 47.3 44.5 425 40.8 34

119455 35 2917 1684 970 1590 917 1456 840 1264 532 487 459 438 420 35

122868 36 3000 1732 99.7 163.4 943 149.8 86.4 1300 547 50.1 472 45.2 43.2 36

126281 37 3083 1780 1025 1680 969 1539 888 1336 562 515 48.5 46.3 444 37

129694 38 316.7 182.8 105.3 172.5 99.6 1581 912 1372 577 52.9 49.8 47.5 45.6 38

133107 39 3250 1876 1080 1771 1022 1622 936 1408 593 54.3 51 1 488 468 39

136520 40 3333 192.4 110.8 1816 1048 1664 960 144 4 608 55.6 524 50.0 48.0 40

139993 41 3417 1972 1136 1861 1074 1706 984 1480 62.3 570 537 513 49.2 41

143346 42 350.0 202.0 1163 1907 1100 1747 100.8 151.6 63.8 58.4 550 52.5 50.4 42

146759 43 3583 2068 1191 1952 1127 1789 1032 1552 653 598 563 538 516 43

150172 44 3667 211.7 121 9 199.8 1153 1830 105.6 158.8 669 61.2 576 550 52.8 44

153585 45 3750 2165 1247 2043 1179 1872 1080 1625 684 626 59.0 56.3 540 45

156998 46 383.3 221.3 127.4 208.8 1205 1914 110.4 1661 69.9 64.0 603 575 55.2 46

160411 47 3917 2261 1302 2134 1231 1955 1128 1697 71 4 65.4 616 588 564 47

163824 48 4000 230,9 1330 217 9 1258 1997 115.2 1733 729 668 629 60.0 57.6 48

167237 49 4083 2357 1357 2225 1284 2038 117 6 176.9 74.4 68.2 642 613 58.8 49

170650 50 4166 240,5 1385 2270 1310 2080 120.0 1805 760 696 655 625 600 50

Right to alterations reserved.~.i.-'l~" ~l!lIS a registered trade mark

t" .. '\ ~I~ - ......Lc.'l--'"---.........:I j,.....,..,J1 ~•.o-> ~ © copyright SAFID 2009 - All Rights ReservEd

Page 30: Safid

IIIIIIIIeIIIII

--

SafidDuct Heaters IZI®Electric Duct Heaters EHO, EHT & EHFT Series

Installation Instructions

Before proceeding heater installation, inspect all heater assembly for any damage during transportation or sitemishandling Check physically all ceramic insulators for breakage and chek coils that none have been damaged

2 The duct which the duct heater to be installed should be constructed In accordance with the standards of theNational Fire Protection Association (NFPA-90A & 90B) for the installation of Air-Conditioning and VentilationSystems

3. Heaters should be installed in the duct with atleast 4 feet downstream from an Air Handler Unit This will allow anychange In direction of airflow to ensure even airflow over the entire heater area

4 Install heaters with at least 4 feet away from the heat pumps or central air conditioners

5 All Cooling Coils, Dampers, Air Filters or Humidifiers must be installed at least 4 feet length away from theheater.

6. Provide 4 feet length between heater and any canvas duct connector or transition sections and provide 2 feetlength between heater and an elbow or turn

7The minimum air velocity is required for the satisfactory operation of heaters Please refer the attached requiredminimum velocity chart Entering air temperature IS limited to 100°F

8For Insert type installation, cut a hole in the side of the duct. 3mm larger than the element metal enclosureportion Insert the heater into this opening and attach control panel to the side of the duct by means of sheetmetal screws For bottom mount type heaters follow the same procedure except. making hole in bottom sideinstead of side If duct is internally insulated, use a recessed type construction to cover the insulation

9. For Flanged type Installation, the flange portion of the heater to be matched with the out turned flanges of theduct. No duct flange in the control panel side as shown below. Join both heater and duct flanges by means ofmetal screws or bolts & nuts. Fasten control panel to duct with sheet metal screws

10Follow the air flow direction arrow in heater control panel and position the heater to match with duct air flow

11Heater control panel should not be covered by any insulation

12Provide enough space to open the door and ease access for maintanance and service

/'l)Ur.l

Follow the schematic wiring diagram pasted inside the heater to make proper power cable and control cabletermination Minimum wire size, fuse sizes are shown in the wiring diagram All electrical connections, wire sizesand type of conduit sizes are according to National Electric Codes (NEC) and local codes

2 All incoming power cables must be rated for 125% of the total load that handle and rated for minimum 75°C

If heater is supplied with Fan Interlock Relay, connect the circuit with fan circuit to energize the heater afterenergize the fan

3 Provide disconnect switch near heater as per NEC. if not supplied with built In heater

4 Do not bundle or tie the power cables

5 Over current protection (power fuse or circuit breaker) must be provided at site if not supplied with heater

6 Provide enough space for air circulation in heat sink if heater supplied with SCR controls

IIII

INSERT TYPE INSTALLATION FLANGED TYPE INSTALLATION

III

Right to alterations reserved.~~~ F'~l!lIS a registered trade mark

I" 'I' •• ~ ",,--,1...... - ..L..:.....:.~ j~1 ~ ~ © copyright SArlO 2009 All Rights Reserved 307

Page 31: Safid

IIIIIII

-­IIIII

--IIIII 308

II

SafidDuct Heaters IZI®Electric Duct Heaters EHO, EHT & EHFT Series

Operation & Maintenance

Operation

Check installation instructions and wiring diagram to make sure that the heater was wired andinstalled properly.

Before proceeding heater operation, make sure that all electrical terminations are tight as these may have looseduring transportation, installation or improper site handling It is recommended to retighten all connection aftercomplete the installation process

2. Clean all dirts, dust and moisture from heater Check for any missing insulation on cables that terminated insidethe heater.

3 Check all fuses and circuit breakers are in position and rating are adequate

4 Check all control circuit wiring and power supply to the controller are match with their requirement.

5 Turn the heater power to on and measure the supply voltage and compare with rated name plate.

6 Power on the control circuit or select the thermostat to heat mode Check the steps are energizing step by stepwith a time delay. Don't allow to energize all steps together of entire heater battery if load is more Use proper timedelay between stages to energize the heater

7 Measure heater ampere to record, either total or step by step for multi step heater Measure airflow and inlet andoutlet temperature to record.

Maintenance & Service

Always shut down the Power supply before doing any work on duct heater.

1. All SAFID Duct Heaters are manufactured with little or no maintenance requirement We propose followingperiodic service to maintain the long life of heater

2 Check for any loose contacts, and retighten all screws if necessary

3 Clean for any dust inside the panel, specially in magnetic contactors

If heater is not operating, check the following, these are the general problems for duct heaters.

1 Power supply to Heater.2 Check for any loose contacts or connections3 Power fuses blow or not4 Check for Control Supply and transformer5 Thermostat is working or not.6 Check fan is operating and maintain the airflow to sense the air pressure for airflow switch7. Check hi-temperature cut-outs (Auto & Manual) are close8 Check airflow switch is closed

Right to alterations reserved.....-L'-__ ""-'C~.L- ~C!lIS a registered trade mark

~.,. •• "\ ........ L... - oU:.:-"--""",, ~,.......JI ~ ~ © copyright SAFID 2009 - All Rights Reserved

/

Page 32: Safid

III

SafidDuct Heaters rzrElectric Duct Heaters EHO, EHT & EHFT Series

I Typical Wiring Diagrams

Se

:-StE'D. J-Phose

rr" ..,.,., ...c., .......... ~"llI'. "'11

~ f'ID ....... ('

__ ractory.,"'-PlJ_-_-_IJ.........:

-,... . ~

-_'." _1 .. • ...-_ -,

r.=~.~----

(l ......n~s$10" 0'- Il,,\t::

I-Step

J-Ste;::l J-Pno":'i'"'vI.tn St'?:::, C0'"1-:: .... 0IL(..•

r.-, ... 1";.-,,_ raCh..-,. ...,. 2-SteD "l-PnosE"

"-,. I"",·'

r,•• 01 .__ r~,o," (.

"Q.JO"1 U"Jt

_._ ~ FoPld ...... to.,. __ rO(tory.rf'O

Pt, • t

IIIIeI

II

II

--IIIII

Right to alterations reserved.~.........,',LL ~IS a registered trade mark

.. "" • q, ~L... - ..Ll.:.,.---.....l j01~ ~ © copyright SAFID 2009 - All Rights Reserved 309

II

Page 33: Safid

- - ---------------

SafidDuct Heaters IZI®Electric Duct Heaters EHO, EHT & EHFT Series

=>

::

"IL

W

C

U

ID

~

:I:

~

5BQ.

'"UjJ~..Q.

E~

LL

Ci>

N:I:

.J:11.

~'0>Q.

'"til~~

i-0

'"N.Ii)U~

c

ClIIIt-

oZ

~I~ow(9zq:--ll.L

Right to alterations reserved.~.i.....4~ ~ClJI$ a registered traae mark

~.,. •• ~ ~L....... - oib:r-........o j~1 G-"'-"" ~ © copyright SAFID 2009 . All Rights Reserved

//~\)~

w0...QZf >-

/~l-I-

I0::

/;wCf)z

~jZ

~\,

0...--..J

--v-- Cf)

r:::0

Gi OJ ".;::"t' l1S- 0 U

l1S 0C ~ -J

0Zc ~

0 41.~ E ...l1S 0 U- - 410 III

.....,:::I :::I 0...0 u c..

+Jo::JC

Duct Heater Submittal

IIIIIII

-­IIIII

-­IIIII 310

II

Page 34: Safid

IIIIIII

-­IIIIItt

III

SafidDuct Heaters 1Z1®Electric Duct Heaters EHO, EHT & EHFT Series

Accessories

Standard Built-In Accessories

1 De-Energizing Magnetic Contactor2 Airflow Switch3 Power and Control Terminal Blocks4 Disc Type Auto and Manual Thermal Cut-Outs5 NEMA-1 Type Control Panel6 1mm Thick Galvanized Steel Construction7 Grounding LugsB. Class-II Control Transformer

Optional Accessories

1. Disconnecting Contactor2. Mercury Contactors3. Transformer Secondary Fusing4 Power Fusing5 Door Interlocking Disconnect Switch (Non-Fused)6 Door Interlocking Disconnect Switch (Fused)7 Disconnect SwitchB. Circuit Breaker9 Modulating SCR (Thyristor) Controller10 Step Controller11. Room Thermostat12. Fan Interlock Relay13. Pilot Light Indications14. Volt Free Contacts for Remote Monitoring15 Remote Control Panel16. Recessed Control Panel17 Bottom Mount Control Panel18 Dust Proof Control Panel19 Stainless Steel Construction20. Aluminized Steel Construction21 Weather Proof Control Panel22. Derated Element Below 35 Watts per Square Inch23 Powder I Epoxy Coating24 SCR with Venier System

Right to alteratIOns reserved.~<i....<:l~ ~IS a registered trade mark

f'" .. "' .......... L.... - ~~ j,..J1~ ~ © copyright SAFID 2009 - All Rights Reserved 311

Page 35: Safid

Electric Duct Heaters

IIIIIII

litIIIII

--IIIII 312

II

SafidDuct Heaters 1Zl®EHO, EHT & EHFT Series

Duct Heater Specification Guide

Sample Specification for Open Coil

Electric duct heaters shall be Open Coil type series "EHO" as manufactured by SAFID Co

2 Capacity, power supply, voltage, phase. duct size. no of steps & controls to be as per project requirement

3 All heaters shall meet the requirement of UL & NEC specifications

4 Heaters shall be either Slip-In Insert type or Flanged type as per project requirement

5 Heating element shall be Type-A, high grade Nickel (80%) Chromium (20%) alloy resistance.

6 Heater frames and Control panel shall be constructed of 20 gauge galvanized steel sheet.

7 Heater element insulators mounting shall be suitable for free floating type and allowing expansion of the insulatorsunder high temperature conditions without cracking or breaking

8 All heaters shall have its load divided into equal steps to a maximum of 48A per steps Fuses and necessarycontrols shall be provided in heaters if total current is more than 48A and subdivide all the steps to limit the loadwithin 48A per steps.

9. All heaters shall be with built in Primary & Secondary over temperature protections, Airflow Switch and necessarymagnetic contactors per each steps

10 All safety devices shall be servicable through the control panel without removing the heater from the duct

11 As built wiring diagram showing wire size, fuse size and complete control and power termination shall be pastedin door of each heater

Sample Specification for Finned or Unfinned Tubular Heater

Electric duct heaters shall be Finned or Unfinned type series "EHFT" / "EHT" as manufactured by SAFID Co.

2 Capacity, power supply, voltage, phase, duct size, no of steps & controls to be as per project requirement

3 All heaters shall meet the requirement of UL & NEC specifications

4 Heaters shall be either Slip-In Insert type or Flanged type as per project requirement

5 Heating element shall be Type-A, high grade Nickel (80%) Chromium (20%) alloy resistance

6 Heater frames and Control panel shall be constructed of 20 gauge galvanized steel sheet

7 Heater element shall be covered with Stainless Steel Tube (for "EHT") & rounded with Stainless Steel Fins (for"EHFT" series) and annealed after assembly

8. All Ileaters shall have its load divided into equal steps to a maximum of 48A per steps. Fuses and necessarycontrols shall be provided in heaters if total current is more than 48A and subdivide all the steps to limit the loadwithin 48A per steps

9 All heaters shall be with built in Primary & Secondary over temperature protections. Airflow Switch and necessarymagnetic contactors per each steps

10 All safety devices shall be servicable through the control panel without removing the heater from the duct

11 As built wiring diagram showing wire size, fuse size and complete control and power termination shall be pastedin door of each heater

Right to alterations reserved."'----~.Lo~ ff1<!lls a regls.tered trade rnark

... ~ , , III ~L .. - ...b,~-...<l j~ll ~ I~J © copyright SAFIO 7.009 All Rights Reserved

Page 36: Safid

IIIIIII

-­IIIIIttIIIIIII

SafidDuct Heaters IZI®Electric Duct Heaters EHO, EHT & EHFT Series

Order Details

Order Code: SEH- ~a~ !!!!: E.~ f!.c!: ~~ !f,: g~ Nt: ii

Model:

o ::: Open Coil ElementT ::: Tubular ElementFT ::: Finned Tubular Element

I::: Slip-In Inser TypeF ::: Flanged Type

S ::: Standard Controls & Constructiono ::: Optional Controls or Construction

K ::: Heater Capacity

S ::: No. of Steps

V::: Power Supply

P ::: No. of Phase

H ::: Frequency

D ::: Duct Size (W x H)

Order Example

Requirements:

Open Coil Heater,slip-in insert type with standard controls and construction, 5 kilowatts, 2 step, 380volts, 3 phase, 60Hz, suitable for 500mm width x 300mm height duct.

Ordering:Make : SAFIDType : SEH - 0 - I - S - 5 - 2 - 380 - 3 - 60 - 500 x 300Qty. : 1 pc

Notes:Refer to accessories page for standard / optional controls & constructions.