  • 8/18/2019 Same Band Combiner Kathrein 9364032

    1/2

       9   3   6 .   4

       0   3   2

       S  u   b   j  e  c   t   t  o

      a   l   t  e  r  a   t   i  o  n .

    KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494

    www.kathrein.de 782 10936 Page 1 of 2

    Pass bandBTS 1 (GSM900 / Operator 1) Rx1/Rx2 = 880 – 890 MHz, Tx1/Tx2 = 925 – 935 MHzBTS 2 (GSM900 / Operator 2) Rx3/Rx4 = 902.5 – 915 MHz, Tx3/Tx4 = 947.5 – 960 MHz

    Insertion lossPort 1 Port 3 / Port 4 Port 6 < 0.5 dB, typically 0.3 dB (880 – 890 MHz) / < 0.7 dB, typically 0.4 dB (925 – 935 MHz)Port 2 Port 3 / Port 5 Port 6 < 0.7 dB, typically 0.5 dB (902.5 – 915 MHz) / < 0.5 dB, typically 0.3 dB (947.5 – 960 MHz)

    IsolationPort 1 Port 2 / Port 4 Port 5 > 30 dB (880 – 890 / 902.5 – 915 / 925 – 935 / 947.5 – 960 MHz)

    VSWR < 1.2 (pass bands)

    Impedance 50 Ω

    Input powerTx1 / Tx2 / Tx3 / Tx4 < 100 W / < 100 W / < 100 W / < 100 W

    Intermodulation products < –160 dBc (3rd order; with 2 x 20 W)

    Temperature range –40 … +60 °C

    Connectors 7-16 female (long neck)

    Application Indoor or outdoor (IP66)

    DC/AISG transparencyPort 1 Port 3 / Port 4 Port 6 StopPort 2 Port 3 / Port 5 Port 6 By-pass (max. 2500 mA)

    Lightning protection 3 kA, 10/350 μs pulse

    Mounting Wall mounting: With 4 screws (max. 8 mm diameter) / Mast mounting: With additional clamp set

    Weight 6.9 kg

    Dimensions (w x h x d) 275 x 176 x 140 mm (without connectors, without mounting brackets)

    Type No. 782 10936

    Technical Data

    • Enables antenna and feeder sharing for two basestations in the same frequency band

    • Suitable for two operators with frequency allocationswithin the same frequency band

    • Very low Tx/Rx insertion loss compared to standardhybrid combiners

    • Double unit for XPol antennas

    • Suitable for indoor or outdoor applications

    • DC/AISG by-pass for DTMA supply

    Same-Band Combiner

    880 – 890 / 925 – 935 MHzGSM900 (10 MHz Bandwidth)

    902.5 – 915 / 947.5 – 960 MHzGSM900 (12.5 MHz Bandwidth)

    Block Diagram

    Tuning Diagram

    Port 1Port 5

    Port 2

    Port 4

    Port 3

    Port 6

  • 8/18/2019 Same Band Combiner Kathrein 9364032

    2/2

       9   3   6 .   4

       0   3   2

       S  u   b   j  e  c   t   t  o

      a   l   t  e  r  a   t   i  o  n .

    KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494

    www.kathrein.dePage 2 of 2 782 10936

    Accessories (order separately)

    734 360 34 – 60 mm

    734 361 60 – 80 mm

    734 362 80 – 100 mm

    734 363 100 – 120 mm

    734 364 120 – 140 mm

    734 365 45 – 125 mm

    Clamp set

    Type No. suitable for mastdiameter of

    Clamp Set

    Typical Attenuation Curves

    BTS 1 (GSM900) BTS 2 (GSM900)

    Diagram I (Port 1 Port 3 / Port 4 Port 6) Diagram III (Port 2 Port 3 / Port 5 Port 6)

    Diagram II (Port 1 Port 3 / Port 4 Port 6) Diagram IV (Port 2 Port 3 / Port 5 Port 6)

    Type No. Description

    784 10367 50-Ohm load

    50-Ohm load

    Same-Band Combiner

    880 – 890 / 925 – 935 MHzGSM900 (10 MHz Bandwidth)

    902.5 – 915 / 947.5 – 960 MHzGSM900 (12.5 MHz Bandwidth)

    As a result of more stringent legal regulations and judgements regardingproduct liability, we are obliged to point out certain risks that may arisewhen products are used under extraordinary operating conditions.

    Extraordinary operating conditions, such as heavy icing or exceptional dynamicstress (e.g. strain caused by oscillating support structures), may result inthe breakage of a mast mounted device or even cause it to fall to the ground.

    These facts must be considered during the site planning process.

    The Same-band Combiner is designed to operate under the environmentalconditions as described in ETS 300 019-1-4 class 4.1 E and have passedenvironmental tests as recommended in ETS 300 019-2-4.

    The installation team must be properly qualified and also be familiar withthe relevant national safety regulations.

    The details given in our data sheets have to be followed carefully wheninstalling the combiners and accessories.

    The limits for the coupling torque of RF connectors,recommended by the connector manufacturersmust be obeyed.

    Terminate unused inputs with a suitable 50-Ohm load,e.g. 784 10367.

    Any previous datasheet issues have now becomeinvalid.

    Please note: