Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies PHOTOMETRIC TESTING & EVALUATION Sample Tested FL3/CL75BZ50/LED Prepared for: David Nelkin Halco Lighting Technologies 2940 Pacific Drive Norcoss, GA 30071 Phone: 770-242-3609 Technical Report Number 70029116 - 3 April 8, 2015 Prepared by: Approved by: Mauricio Anderson, Project Manager Jesse Whalen, Operations Manager 6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134 Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 1 of 14

Upload: others

Post on 31-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

PHOTOMETRIC TESTING & EVALUATION

Sample Tested FL3/CL75BZ50/LED

Prepared for:

David Nelkin

Halco Lighting Technologies 2940 Pacific Drive Norcoss, GA 30071

Phone: 770-242-3609

Technical Report Number 70029116 - 3

April 8, 2015

Prepared by: Approved by: Mauricio Anderson, Project Manager Jesse Whalen, Operations Manager

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134 Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 1 of 14

Page 2: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

Program Description Photometric and electrical testing of a “FL3/CL75BZ50/LED” replacement fixture. Data referenced from report 2760415 – 1. Executive Summary Sample Tested = FL3/CL75BZ50/LED, Product Number 99903. Luminous Efficacy*

(Lumens/Watt) Luminous Flux*

(Lumens) Input Power*

(Watts) Power Factor*

80.38 5964 74.19 0.9966

CCT (K)* CRI* Stabilization Time (Light & Power)

5109 74.9 60 minutes * The above results are recorded / derived from measurements made using an Integrating Sphere

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134 Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 2 of 14

Page 3: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

TABLE OF CONTENTS

Sample..................................................................................................................................................................... 4

Test Results ............................................................................................................................................................. 5

Spectral Flux ........................................................................................................................................................... 6

Chromaticity Diagram ............................................................................................................................................ 7

Flux Distribution – Zonal Lumen Summary ........................................................................................................... 8

Illuminance Plots .................................................................................................................................................... 9

Candela Plots ........................................................................................................................................................ 10

Candela Tabulation ............................................................................................................................................... 11

Photometric Testing Information .......................................................................................................................... 12

Equipment List: ..................................................................................................................................................... 14

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134 Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 3 of 14

Page 4: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

Sample

The following sample was submitted for evaluation:

Halco Lighting Technologies: FL3/CL75BZ50/LED

FL3/CL75BZ50/LED

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 4 of 14

Page 5: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

Test Results – The following results were measured after stabilization of the sample in the Integrating Sphere (unless otherwise stated). Stability is reached when the variation of 3 readings of light output and electrical power, taken 15 minutes apart, is less than 0.50%.

Key Photometric Results Sample Reference FL3/CL75BZ50/LED

Integrating Sphere Goniophotometer Luminous Efficacy (Lumens/Watt) 80.38 80.42

Total Luminous Flux (Lumens) 5964 5967.76

Total Radiant Flux (Watts) 17.84

Correlated Color Temperature (CCT) 5109

Color Rendering Index (CRI) (Ra) 74.9

R1 thru R7 Value 74.4 73.9 70 85.9 75 62.7 85.1

R8 thru R14 Value 72.6 -7.8 34 81.6 34.4 71.8 82.8

Chromaticity (Chroma x / Chroma y) 0.3425 / 0.3561

Chromaticity (Chroma u / Chroma v) 0.2080 / 0.3243

Chromaticity (Chroma u’ / Chroma v’) 0.2080 / 0.4865

Duv Value 0.0026

Stabilization Time (Light and Power) Approx. 60 minutes

Total Run Time – Integrating Sphere 64 minutes

Total Run Time – Goniophotometer 66 minutes

Spacing Criteria 1.24 (0° – 180°) / 1.30 (90° – 270°)

Scotopic/Photopic ratio Φ(v')/Φ(v) 1.83

Electrical Input Results: Sample Reference FL3/CL75BZ50/LED

Input Power (Watts) 74.19 72.44

Input Voltage (Volts AC) 120.00 277.03

Input Current (Amps) 0.6204 0.28288

Input Frequency (Hertz) 60.0 60.0

Power Factor 0.9966 0.9243

Total Harmonic Distortion (%THD V/A) 0.09 / 7.84 0.08 / 9.79

Additional Information Sample Reference FL3/CL75BZ50/LED

Ambient Temperature 24.9°C

Integrating Sphere Detector CDS 600 Spectroradiometer

Absorption Correction used? Yes

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 5 of 14

Page 6: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

Spectral Flux The following graph shows the spectral response curve of the radiant flux for the sample:

Spectral response of the Radiant Flux (350nm to 850nm – calibrated range of the Spectroradiometer).

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 6 of 14

Page 7: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

Chromaticity Diagram The following image shows the chromaticity diagram for the sample:

Tristimulus values (from page 6): x / y = 0.3425 / 0.3561

The locations on the diagram of the tristimulus coordinates are indicated by the blue diamond.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 7 of 14

Page 8: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

Test Results – Flux Distribution – Zonal Lumen Summary The following table depicts the zonal lumen distribution for the sample:

Zone Lumens % Total 0-10 235.2 3.9% 10-20 681.0 11.4% 20-30 1,047.5 17.6% 30-40 1,215.7 20.4% 40-50 1,143.3 19.2% 50-60 962.2 16.1% 60-70 568.7 9.5% 70-80 108.2 1.8% 80-90 6.3 0.1%

Total 5968.0 LUMENS 100%

Zonal Lumen Summary Zone Lumens % Luminaire 0-30 1,963.6 32.9% 0-40 3,179.4 53.3% 0-60 5,284.8 88.6% 60-90 683.2 11.4% 0-90 5,968.0 100%

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 8 of 14

Page 9: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

Test Results – Illuminance Plots The following images depict the illuminance characteristics of the luminaire.

Beam Angle Field Angle

Illuminance Plot (Footcandles)

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 9 of 14

Page 10: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

Coefficients Of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance: 20% RCC %: 80 70 50 30 10 0 RW %: RCR: 0

1 2 3 4 5 6 7 8 9

10

70 50 30 0 1.19 1.19 1.19 1.19 1.11 1.07 1.03 1.00 1.02 .95 .89 .84 .94 .84 .77 .71 .86 .75 .67 .61 .79 .68 .59 .53 .74 .61 .53 .47 .68 .56 .47 .41 .64 .51 .43 .37 .60 .47 .39 .34 .56 .43 .36 .31

70 50 30 0 1.16 1.16 1.16 1.00 1.08 1.04 1.01 .88 .99 .93 .87 .77 .91 .83 .76 .66 .84 .74 .66 .58 .77 .66 .59 .51 .72 .60 .52 .45 .67 .55 .47 .40 .62 .50 .42 .36 .58 .46 .39 .33 .55 .43 .35 .30

50 30 20 1.11 1.11 1.11 1.00 .98 .95 .89 .85 .81 .80 .74 .69 .71 .65 .60 .64 .58 .52 .58 .51 .46 .53 .46 .41 .49 .42 .37 .45 .38 .33 .42 .35 .30

50 30 20 1.06 1.06 1.06 .96 .94 .92 .86 .82 .79 .77 .72 .68 .69 .64 .59 .62 .56 .52 .57 .50 .46 .52 .45 .41 .48 .41 .37 .44 .38 .33 .41 .35 .30

50 30 20 1.02 1.02 1.02 .93 .91 .90 .83 .80 .77 .75 .70 .67 .67 .62 .58 .61 .55 .51 .55 .50 .45 .51 .45 .40 .46 .41 .36 .43 .37 .33 .40 .34 .30

0 1.00 .88 .75 .65 .56 .49 .43 .39 .35 .31 .28

Test Results – Candela Plots The following images depict the luminous intensity distribution characteristics of the luminaire.

Isocandela Plot Polar Candela Distribution

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 10 of 14

Page 11: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

Continued……

Test Results – Candela Tabulation

The following table provides the tabulated Candela measurements: Candela Table - Type C

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 0 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478 2478

2.5 2507 2482 2481 2484 2487 2475 2475 2478 2478 2488 2471 2475 2486 2467 2464 2463 2473 2466 2497 2477 2473 2469 2482 2471 2470 2475 2476 2490 2469 2484 2488 2476 2466 2466 2481 2477 2507 5 2503 2475 2475 2483 2479 2471 2475 2471 2469 2479 2463 2463 2481 2462 2456 2459 2469 2458 2497 2476 2475 2465 2478 2469 2467 2472 2474 2486 2464 2479 2483 2473 2463 2463 2481 2476 2503

7.5 2488 2467 2465 2480 2468 2462 2470 2461 2458 2469 2454 2453 2471 2451 2441 2446 2455 2445 2483 2467 2468 2454 2466 2458 2451 2458 2461 2475 2454 2469 2475 2465 2454 2451 2473 2468 2488 10 2476 2457 2451 2470 2451 2448 2457 2449 2446 2455 2443 2436 2453 2436 2424 2431 2439 2430 2465 2454 2453 2433 2447 2449 2435 2444 2445 2463 2443 2457 2462 2452 2444 2440 2462 2458 2476

12.5 2460 2440 2436 2450 2430 2427 2442 2437 2428 2436 2428 2417 2441 2423 2405 2416 2418 2412 2445 2436 2434 2413 2430 2434 2418 2425 2429 2447 2431 2447 2444 2434 2428 2426 2447 2445 2460 15 2443 2420 2417 2428 2411 2411 2423 2418 2404 2413 2410 2397 2421 2401 2382 2397 2393 2393 2423 2413 2411 2392 2408 2409 2393 2402 2409 2425 2412 2429 2420 2409 2407 2408 2427 2429 2443

17.5 2421 2391 2397 2402 2384 2387 2393 2388 2379 2384 2385 2373 2391 2375 2355 2373 2364 2364 2396 2386 2381 2365 2382 2384 2365 2376 2383 2396 2390 2403 2394 2383 2380 2383 2400 2408 2421 20 2390 2363 2369 2371 2355 2358 2361 2355 2348 2352 2353 2344 2363 2343 2325 2344 2335 2330 2370 2353 2344 2334 2349 2350 2333 2346 2356 2362 2358 2367 2363 2353 2354 2356 2371 2381 2390

22.5 2357 2329 2327 2336 2318 2324 2326 2318 2312 2319 2319 2308 2326 2309 2292 2310 2300 2296 2337 2312 2311 2298 2312 2313 2299 2315 2319 2323 2322 2331 2328 2320 2324 2330 2346 2346 2357 25 2319 2294 2287 2302 2285 2290 2286 2280 2274 2281 2281 2272 2285 2266 2254 2268 2259 2255 2294 2274 2271 2257 2273 2269 2257 2278 2276 2284 2284 2286 2281 2279 2290 2295 2302 2306 2319

27.5 2199 2195 2233 2261 2246 2249 2241 2238 2232 2234 2235 2227 2239 2215 2209 2220 2204 2156 2210 2208 2227 2213 2228 2227 2214 2230 2229 2237 2239 2235 2236 2237 2250 2253 2261 2251 2199 30 2033 2029 2046 2186 2197 2200 2200 2192 2187 2187 2182 2175 2187 2165 2163 2156 2031 1986 2015 2014 2090 2157 2177 2183 2164 2179 2176 2185 2187 2184 2191 2193 2204 2201 2136 2056 2033

32.5 1975 1970 1967 1994 2136 2148 2145 2138 2131 2128 2126 2063 2134 2109 2108 1964 1922 1920 1949 1948 1946 2000 2120 2129 2116 2123 2121 2126 2128 2134 2141 2145 2154 2055 1978 1977 1975 35 1919 1913 1917 1918 1966 2093 2088 2047 1902 1810 1869 1875 2074 2052 1971 1871 1858 1855 1892 1892 1890 1877 1997 2065 2061 2061 2042 2036 2055 2071 2083 2093 2062 1920 1927 1921 1919

37.5 1866 1850 1864 1865 1854 2012 1987 1698 1537 1523 1527 1599 1918 1979 1818 1814 1799 1789 1833 1831 1822 1819 1826 1993 1996 1907 1664 1643 1686 1896 2018 2027 1873 1863 1869 1863 1866 40 1804 1790 1802 1810 1794 1827 1637 1483 1466 1462 1464 1451 1528 1817 1751 1745 1737 1726 1769 1763 1755 1758 1758 1847 1819 1507 1462 1466 1467 1494 1815 1919 1792 1804 1809 1802 1804

42.5 1733 1720 1728 1741 1731 1623 1428 1424 1406 1403 1404 1388 1403 1410 1678 1668 1660 1651 1695 1689 1684 1686 1686 1679 1424 1397 1401 1406 1405 1406 1425 1712 1723 1733 1742 1736 1733 45 1655 1647 1653 1664 1654 1293 1349 1360 1340 1338 1339 1326 1335 1216 1577 1595 1583 1567 1614 1606 1607 1614 1615 1365 1334 1332 1335 1338 1345 1347 1351 1339 1652 1658 1666 1663 1655

47.5 1575 1563 1573 1584 1518 1196 1214 1289 1267 1270 1267 1258 1244 1151 1265 1510 1495 1488 1525 1522 1521 1530 1531 1171 1222 1264 1261 1273 1278 1280 1272 1189 1552 1581 1590 1582 1575 50 1482 1475 1479 1501 1175 1127 1114 1217 1192 1192 1192 1186 1109 1085 1088 1417 1409 1395 1439 1425 1427 1438 1266 1102 1099 1193 1189 1207 1205 1206 1141 1125 1227 1503 1505 1498 1482

52.5 1382 1381 1384 1403 1062 1056 1042 1132 1119 1114 1112 1107 1017 1013 1007 1293 1315 1298 1341 1325 1331 1336 1027 1030 1024 1118 1115 1126 1125 1128 1035 1055 1062 1414 1411 1409 1382 55 1277 1279 1278 1257 989 980 969 1046 1031 1029 1028 1021 933 928 923 987 1210 1194 1241 1229 1231 1232 940 953 946 1035 1033 1045 1040 1045 962 979 987 1277 1310 1307 1277

57.5 1150 1156 1165 941 904 897 884 917 935 931 930 929 846 841 835 855 1097 1066 1120 1122 1118 1007 858 869 864 934 943 955 949 957 882 902 907 974 1200 1195 1150 60 939 939 976 813 806 802 792 784 840 825 828 792 750 746 743 738 911 871 923 929 972 858 767 780 779 789 846 854 852 849 797 818 822 825 1081 996 939

62.5 822 821 827 658 699 701 684 671 722 717 712 647 647 640 644 585 736 757 803 796 801 709 672 683 682 678 741 746 749 708 705 725 727 730 861 857 822 65 688 685 679 529 550 578 566 551 584 579 578 519 527 522 508 470 493 624 680 671 672 560 555 573 568 572 623 622 631 588 595 616 609 560 698 729 688

67.5 530 531 422 410 402 441 428 409 351 317 324 340 392 389 360 354 355 464 526 521 452 411 400 439 438 437 475 456 482 455 468 484 445 446 450 575 530 70 354 350 285 279 276 272 241 193 206 201 196 179 183 229 234 230 226 292 349 349 273 272 272 283 293 255 229 222 227 266 323 335 308 316 318 410 354

72.5 201 198 155 161 165 137 115 116 119 120 116 106 101 99 132 119 117 153 194 194 151 165 169 167 135 125 137 139 140 135 146 187 197 201 191 242 201 75 104 105 84 82 74 62 60 61 56 56 56 54 52 51 47 63 63 71 100 103 85 86 93 72 71 73 75 79 79 78 77 77 112 106 105 136 104

77.5 53 52 43 43 34 32 30 22 21 22 21 21 25 27 29 32 35 35 50 52 46 49 41 42 42 41 34 37 38 44 43 45 44 59 56 62 53 80 29 24 25 20 20 15 13 9 7 7 7 9 11 12 14 16 19 19 29 28 27 25 24 23 17 17 17 17 17 18 18 25 27 26 32 31 29

82.5 14 12 11 10 7 6 4 4 4 4 4 4 4 4 5 7 7 9 15 14 14 13 11 10 7 6 6 6 6 6 8 10 14 15 16 17 14 85 4 4 3 3 3 2 2 2 2 2 2 2 2 2 2 2 3 2 4 4 4 4 3 4 4 4 4 4 4 4 4 4 4 6 6 6 4

87.5 1 2 1 1 1 1 1 1 1 1 1 0 0 1 0 1 1 0 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 90 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 11 of 14

Page 12: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

Continued…..

Photometric Testing Information The sample was evaluated for photometric and electrical characteristics using an integrating sphere and a goniophotometer, each located in purpose-built, temperature and humidity-controlled, draft free environments. The integrating sphere is by Labsphere which exhibits a “4π geometry” configuration according to IES LM-79-08 and is applicable for all types of LED products (directional and non-directional light projections). Its spectroradiometer is an array-type detector manufactured and calibrated by Labsphere. The integrating sphere uses self-absorption correction to eliminate errors due to mismatches between the standard reference lamp and the test samples being measured. The auxiliary lamp used to perform this task is a halogen type lamp powered by a calibrated Lamp Power Supply manufactured and calibrated by Labsphere. Ambient temperature (for photometric analysis) is measured using a “J-Type” thermocouple located inside the integrating sphere at the same height as the sample under test and not more than 1 meter in horizontal distance away from the sample. The thermocouple is located behind the baffle of the photo detector in order to eliminate any direct optical radiation from the sample under test. Luminaire Stabilization. The sample was placed inside the integrating sphere and powered by a regulated and conditioned Voltage alternating current supply. The correlated color temperature, color rendering index, chromaticity coordinates and electrical power measurements contained in this report are the numeric averages of the three readings upon which stabilization is verified. The stabilization times shown on the results pages of this report denote the time of the 1st measurement (of the 3 consecutive readings) since this is the minimum time that the sample is assumed to have taken to reach stabilization. The integrating sphere is calibrated using a quartzline halogen lamp with the following specifications: Sphere D Sphere B & C Manufacturer: Sylvania Sylvania Model# 75Q/CL-28V 796 Voltage = 28.0 Volt 12.0 Volt Wattage = 75.0 Watts 32.0 Watts Calibration Current = 2.679 Amperes 2.600Amperes Luminous Flux = 1538.8 Lumens 554.0 Lumens Calibration Date = 8-18-2005 11-13-2013 (calibrated by Labsphere – NIST traceable).

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 12 of 14

Page 13: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

Photometric Testing Information (continued)

The goniophotometer Mayer Engineering Type C is calibrated using a frosted tungsten filament FDS/DZE lamp with the following specifications: Manufacturer: GE Part Number: DZE 88 Bulb Number: 114-A Voltage: 16.59 Volts DC reference Calibration Current: 4.810 Amperes Luminous Intensity: 154.7 Candelas Calibration Date: 7/12/12 (NIST traceable) Manufacturer: GE Part Number: DZE 88 Bulb Number: 114-B Voltage: 16.61 Volts DC reference Calibration Current: 4.819 Amperes Luminous Intensity: 150.6 Candelas Calibration Date: 7/12/12(NIST traceable) Manufacturer: GE Part Number: DZE 88 Bulb Number: 114-C Voltage: 16.66 Volts DC reference Calibration Current: 4.815 Amperes Luminous Intensity: 155.4 Candelas Calibration Date: 7/12/12 (NIST traceable) A Yokogawa WT210 Power Analyzer was used to measure all electrical characteristics of the sample.

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 13 of 14

Page 14: Sample Tested FL3/CL75BZ50/LED · 2015-04-13 · Report: 70029116 - 3 Project: 70029116 Client: Halco Lighting Technologies . Test Results – The following results were measured

Report: 70029116 - 3

Project: 70029116 Client: Halco Lighting Technologies

All equipment is calibrated to ISO / IEC 17025-2005 guidelines.

Equipment List: Goniophotometer Type C (Mirror 1)

Description Manufacturer and Model Number

CSA Instrument Reference Number

Calibration Due Date

Optometer Gigahertz Optik P9801 N/A N/A

Regulated Power Supply Chroma Instruments 61602P-80-60 DCP401 N/A

Regulated Power Supply Chroma Instruments 61602 DCP301 N/A Power Analyzer Yokogawa WT210 POA400 11/2015 Equipment List: Sphere D Equipment

Description Manufacturer and Model Number

CSA Instrument Reference Number

Calibration Due Date

Integrating Sphere 109” Labsphere LMS760 SPH400 N/A Spectroradiometer Labsphere CDS1100 N/A N/A Auxiliary Lamp PSU Labsphere LPS100 LPS100 N/A Power Analyzer Yokogawa WT210 PA118 12/2015 Regulated Power Supply Chroma Instruments 61603 N/A N/A

6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134

Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948 www.csagroup.com Page 14 of 14