sample tested ln160-a30 led high bay
TRANSCRIPT
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 1 of 15
PHOTOMETRIC TESTING & EVALUATION TO IES LM-79-08
Sample Tested
LN160-A30
LED HIGH BAY
Prepared for:
Janie Chung
KMW Inc.
183-6 Youngcheon-ro, Dongtan-myun
Hwasung-si, Gyeonggi-do
Korea 445-813
Phone: 253-826-7636
Technical Report Number 2594747
March 7, 2013
Prepared by: Approved by:
James E. Berkeley, Program Manager Wensheng Xu, Technical Advisor
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 2 of 15
Program Description
Photometric and electrical testing of a “LN160-A30 LED HIGH BAY ” replacement luminaire to IES LM-79-08.
Executive Summary
Sample Tested = LN160-A30 LED HIGH BAY Sample #1, S/N 12120001S
Luminous Efficacy*
(Lumens/Watt)
Luminous Flux*
(Lumens)
Input Power*
(Watts) Power Factor*
100.24 15700 156.62 0.996
CCT (K)* CRI* Stabilization Time
(Light & Power)
3042.2 83.2 60 minutes
* The above results are recorded / derived from measurements made using an Integrating Sphere
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 3 of 15
TABLE OF CONTENTS
Sample..................................................................................................................................................................... 4
Test Results ............................................................................................................................................................. 5
Spectral Flux ........................................................................................................................................................... 6
Chromaticity Diagram ............................................................................................................................................ 7
Flux Distribution – Zonal Lumen Summary ........................................................................................................... 8
Illuminance Plots .................................................................................................................................................... 9
Candela Plots ........................................................................................................................................................ 10
Candela Tabulation ............................................................................................................................................... 11
In Situ Measurement: ............................................................................................................................................ 12
Photometric Testing Information .......................................................................................................................... 13
Equipment List: ..................................................................................................................................................... 15
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 4 of 15
Sample
The following sample was submitted for evaluation:
KMW Inc.: LN160-A30 LED HIGH BAY
LN160-A30 LED HIGH BAY
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 5 of 15
Test Results –
The following results were measured after stabilization of the sample in the Integrating Sphere (unless
otherwise stated). Stability is reached when the variation of 3 readings of light output and electrical power,
taken 15 minutes apart, is less than 0.50% (in accordance with IES LM-79-08).
Key Photometric Results Sample Reference
LN160-A30 LED HIGH BAY
Integrating Sphere Goniophotometer
Luminous Efficacy (Lumens/Watt) 100.24 99.62
Total Luminous Flux (Lumens) 15700 15728.9
Total Radiant Flux (Watts) 50.13
Correlated Color Temperature (CCT) 3042.2
Color Rendering Index (CRI) (Ra) 83.2
R9 Value 14.4
Chromaticity (Chroma x / Chroma y) 0.4347 / 0.4047
Chromaticity (Chroma u / Chroma v) 0.2488 / 0.3475
Chromaticity (Chroma u’ / Chroma v’) 0.2488 / 0.5213
Duv Value 0.00059
Stabilization Time (Light and Power) Approx. 60 minutes
Total Run Time – Integrating Sphere 64 minutes
Total Run Time – Goniophotometer 129 minutes
Spacing Criteria 0.98 (0° – 180°) / 1.00 (90° – 270°)
Electrical Input Results: Sample Reference
LN160-A30 LED HIGH BAY
Integrating Sphere Goniophotometer
Input Power (Watts) 156.62 (152.80) 157.89
Input Voltage (Volts AC) 120.0 (277.0) 120.0
Input Current (Amps) 1.310 (0.576) 1.310
Input Frequency (Hertz) 60 60
Power Factor 0.996 (0.956) 0.996
Total Harmonic Distortion (%THD V/A) 0.11 / 5.31 (0.11 / 15.78)
Additional Information Sample Reference
LN160-A30 LED HIGH BAY
Ambient Temperature 24.8°C
Integrating Sphere Detector CDS 600 Spectroradiometer
Absorption Correction used? Yes
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 6 of 15
Spectral Flux
The following graph shows the spectral response curve of the radiant flux for the sample:
Spectral response of the Radiant Flux
(350nm to 850nm – calibrated range of the Spectroradiometer).
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 7 of 15
Chromaticity Diagram
The following image shows the chromaticity diagram for the sample:
Tristimulus values (from page 6):
x / y = 0.4347 / 0.4047
The locations on the diagram of the tristimulus coordinates are indicated by the blue diamond.
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 8 of 15
Test Results – Flux Distribution – Zonal Lumen Summary
The following table depicts the zonal lumen distribution for the sample:
Zone Lumens % Total 0 - 10 1,472.60 9.40%
10 - 20 4,476.40 28.50%
20 - 30 5,129.10 32.60%
30 - 40 3,054.10 19.40%
40 - 50 1,210.20 7.70%
50 - 60 302.5 1.90%
60 - 70 51.6 0.30%
70 - 80 21 0.10%
80 - 90 11.4 0.10%
90 - 100 0 0%
100 - 110 0 0%
110 - 120 0 0%
120 - 130 0 0%
130 - 140 0 0%
140 - 150 0 0%
150 - 160 0 0%
160 - 170 0 0%
170 - 180 0 0%
Total 15728.9 Lumens 100%
Zonal Lumen Summary
Zone Lumens % Lamp / Luminaire 0-30 11,078.10 70.40%
0-40 14,132.20 89.80%
0-60 15,644.90 99.50%
60-90 84 0.50%
0-90 15,728.90 100%
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 9 of 15
Test Results – Illuminance Plots
The following images depict the illuminance characteristics of the luminaire.
Beam Angle Field Angle
Illuminance Plot (Footcandles)
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 10 of 15
Coefficients Of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance: 20% RCC %: 80 70 50 30 10 0 RW %: RCR: 0
1 2 3
4 5 6
7 8
9 10
70 50 30 0
1.19 1.19 1.19 1.19 1.13 1.11 1.08 1.06 1.08 1.03 .99 .95
1.02 .96 .91 .87 .97 .89 .84 .79 .92 .83 .77 .73
.87 .78 .72 .68
.83 .73 .67 .63
.79 .69 .63 .59
.75 .65 .59 .55
.71 .61 .56 .52
70 50 30 0
1.16 1.16 1.16 1.00 1.11 1.08 1.06 .94 1.05 1.01 .97 .87
1.00 .94 .90 .81 .95 .88 .83 .76 .90 .82 .77 .70
.86 .77 .72 .66
.81 .73 .67 .62
.77 .68 .63 .58
.74 .65 .59 .54
.70 .61 .55 .51
50 30 20
1.11 1.11 1.11 1.04 1.03 1.01 .98 .95 .92
.92 .88 .84
.86 .81 .78
.81 .76 .72
.76 .71 .67
.71 .66 .62
.67 .62 .58
.64 .58 .55
.60 .55 .51
50 30 20
1.06 1.06 1.06 1.01 .99 .98 .95 .92 .90
.89 .86 .83
.84 .80 .77
.79 .75 .71
.74 .70 .66
.70 .66 .62
.66 .62 .58
.63 .58 .55
.59 .55 .51
50 30 20
1.02 1.02 1.02 .97 .96 .95 .92 .90 .88
.87 .84 .82
.82 .79 .76
.77 .74 .71
.73 .69 .66
.69 .65 .62
.65 .61 .58
.62 .57 .54
.59 .54 .51
0
1.00 .93 .87
.80
.75
.69
.65
.60
.56
.53
.50
Test Results – Candela Plots
The following images depict the luminous intensity distribution characteristics of the luminaire.
Isocandela Plot Polar Candela Distribution
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 11 of 15
Test Results – Candela Tabulation
The following table provides the tabulated Candela measurements: Candela Table - Type C
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360
0 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944 14944
2.5 14957 15052 15025 14989 15106 15017 14990 14975 15026 14996 14972 15009 15061 15013 14988 15024 15002 14964 14931 14938 14923 14890 14916 14934 14930 14910 14937 14940 14908 14935 14963 14928 14923 14939 14931 14913 14957
5 15157 15311 15213 15195 15266 15185 15178 15167 15183 15157 15212 15252 15252 15223 15181 15163 15088 15108 14948 14961 14980 14968 14974 14976 14985 14989 15042 15061 15046 15057 15024 15005 15032 15042 15032 15027 15157
7.5 15605 15763 15707 15610 15657 15614 15540 15599 15651 15574 15606 15723 15595 15588 15640 15618 15508 15479 15227 15199 15193 15239 15187 15259 15304 15314 15319 15333 15364 15349 15299 15337 15353 15412 15349 15327 15605
10 16240 16302 16280 16159 16285 16183 16090 16246 16260 16237 16228 16333 16175 16126 16254 16177 16084 16030 15673 15658 15672 15710 15698 15711 15770 15818 15786 15750 15816 15948 15914 15868 15901 16002 15919 15890 16240
12.5 16474 16595 16778 16606 16446 16705 16666 16464 16571 16720 16634 16532 16615 16780 16468 16511 16579 16470 16187 16116 16079 15963 16028 16170 16126 16013 16241 16276 16231 16111 16332 16347 16214 16267 16407 16363 16474
15 16144 16327 16475 16416 16231 16519 16553 16240 16405 16603 16497 16304 16634 16669 16303 16300 16440 16196 15911 16199 16151 15816 15995 16147 16002 15708 16041 16248 16025 15855 16237 16322 16042 16091 16486 16421 16144
17.5 15413 15562 15834 15699 15521 15895 15854 15457 15677 15964 15797 15615 16009 16060 15604 15553 15697 15525 15355 15671 15656 15286 15353 15568 15307 15113 15410 15593 15300 15290 15691 15737 15327 15430 15823 15787 15413
20 14240 14400 14750 14505 14429 14797 14753 14363 14537 14932 14646 14561 14888 14935 14562 14525 14680 14360 14440 14700 14658 14316 14365 14562 14309 14096 14311 14580 14282 14211 14548 14613 14411 14438 14727 14794 14240
22.5 12745 13036 13304 13059 12901 13323 13316 12888 12857 13468 13301 13113 13512 13433 13056 13052 13193 12973 13032 13438 13366 12943 12987 13260 13022 12705 13021 13219 12863 12730 13091 13147 12896 13006 13407 13412 12745
25 11083 11300 11378 11378 11371 11621 11656 11508 11178 11716 11659 11551 11743 11683 11448 11470 11394 11257 11555 11812 11730 11418 11455 11508 11459 11189 11399 11418 11320 11198 11464 11376 11305 11469 11640 11811 11083
27.5 9155 9302 9207 9492 9499 9540 9572 9555 9498 9572 9692 9557 9753 9605 9450 9524 9263 9286 9893 9971 9835 9693 9633 9549 9554 9349 9518 9372 9417 9351 9521 9480 9496 9582 9735 9828 9155
30 7200 7441 7460 7532 7536 7690 7720 7679 7818 7767 7843 7741 7844 7739 7581 7626 7565 7515 8012 8046 7828 7754 7774 7673 7737 7524 7603 7529 7547 7518 7577 7610 7614 7704 7842 7993 7200
32.5 5653 5934 5947 5987 5946 6153 6216 6033 6237 6244 6249 6144 6320 6209 6035 6104 6381 5954 6343 6461 6367 6189 6198 6160 6166 5912 6092 5973 6054 5910 6076 6065 6023 6146 6224 6429 5653
35 4496 4546 4676 4653 4747 4745 4781 4830 4807 4890 4870 4841 4882 4806 4783 4741 5399 4631 4992 4984 4982 4876 4828 4812 4748 4709 4689 4741 4680 4677 4717 4743 4748 4807 4881 4870 4496
37.5 3511 3492 3618 3584 3676 3642 3643 3752 3711 3819 3754 3809 3731 3692 3718 3662 4417 3546 3916 3813 3803 3756 3732 3711 3630 3679 3583 3650 3564 3612 3551 3612 3669 3657 3771 3716 3511
40 2663 2635 2702 2706 2808 2747 2762 2854 2815 2869 2858 2933 2823 2800 2855 2780 3435 2666 3014 2878 2890 2860 2821 2817 2720 2809 2715 2740 2704 2787 2699 2733 2827 2817 2869 2837 2663
42.5 1924 1976 2006 1992 2041 2069 2065 2092 2088 2113 2132 2144 2116 2104 2118 2076 2453 1987 2237 2170 2143 2156 2116 2085 2054 2059 2032 2006 2011 2049 2026 2048 2109 2207 2116 2116 1924
45 1352 1414 1451 1420 1434 1468 1497 1447 1501 1537 1554 1500 1508 1504 1474 1480 1487 1443 1572 1569 1579 1537 1509 1530 1482 1436 1478 1484 1456 1409 1458 1490 1484 1798 1574 1548 1352
47.5 916 968 996 967 987 1013 1029 1006 1025 1066 1052 1040 1037 1035 1005 1012 1014 985 1095 1100 1091 1045 1039 1050 1024 979 1007 1012 985 980 1000 1026 1012 1389 1086 1082 916
50 654 660 666 675 678 681 701 691 710 713 730 715 709 695 684 690 676 674 747 757 725 711 708 698 710 689 698 686 683 674 675 693 690 980 723 748 654
52.5 459 423 434 458 482 436 436 491 478 474 484 505 459 446 477 471 439 437 537 492 475 502 495 456 450 490 453 448 452 476 442 445 488 571 464 483 459
55 275 300 307 307 300 318 322 310 317 332 321 316 326 320 301 301 313 307 361 335 334 325 321 323 313 308 315 319 302 303 306 312 305 309 331 335 275
57.5 160 158 194 169 180 192 193 188 179 207 183 179 193 193 178 166 197 167 212 222 232 194 189 210 190 178 166 201 168 171 184 203 179 181 218 206 160
60 88 87 83 93 92 94 100 98 96 93 92 100 98 98 95 90 87 87 120 106 106 104 102 93 95 97 90 89 87 97 96 96 98 96 100 102 88
62.5 53 65 60 65 57 66 67 58 66 64 65 60 65 66 60 63 62 63 66 66 66 65 62 63 65 57 63 66 63 58 63 64 64 64 65 67 53
65 45 47 43 48 46 47 49 46 48 48 47 47 46 44 47 46 45 47 47 52 49 48 46 47 48 45 47 45 46 46 45 44 48 46 46 51 45
67.5 37 37 34 35 37 37 38 38 37 37 35 38 38 37 37 34 35 37 43 39 36 36 36 37 37 39 35 35 34 39 37 38 37 36 38 39 37
70 29 31 27 28 28 33 31 30 31 29 29 28 34 33 28 28 28 30 31 32 31 28 27 34 32 29 28 28 28 28 34 33 28 29 33 32 29
72.5 23 23 22 22 23 24 23 25 25 23 23 23 25 24 23 23 22 23 26 27 24 23 23 24 25 23 22 22 22 23 25 24 22 23 24 26 23
75 19 18 18 18 19 18 19 19 18 19 18 19 19 19 19 18 18 18 20 19 19 18 19 18 18 19 17 18 18 19 18 18 18 18 19 19 19
77.5 16 16 15 16 16 16 16 16 16 15 16 16 16 16 16 16 15 16 17 17 16 16 16 16 16 16 15 14 15 15 15 15 16 16 16 17 16
80 13 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 15 14 15 14 15 14 14 14 14 14 13 14 13 14 13 13 13 14 15 14 13
82.5 12 12 12 12 12 13 12 11 12 13 12 11 13 12 12 12 13 12 12 13 13 12 12 12 12 11 11 12 11 11 12 12 11 12 13 12 12
85 10 10 11 11 11 10 11 10 10 11 10 10 10 10 11 10 11 11 11 11 11 11 10 10 10 10 10 10 10 9 10 10 10 10 11 11 10
87.5 9 9 8 9 9 8 9 10 9 8 9 9 9 9 9 9 8 9 10 10 9 10 9 9 9 9 8 8 8 9 8 8 9 9 8 10 9
90 7 7 7 7 8 7 7 8 7 7 7 8 7 7 8 8 7 7 9 8 7 8 8 7 7 7 7 6 6 7 6 6 7 7 7 7 7
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 12 of 15
Thermocouple Location Temperature Measured (°C)
LED Array Center / Driver 45.3 / 39.2
Ambient 25.0
All equipment is calibrated to ISO / IEC 17025-2005 guidelines.
TC Location on LED TC Location on Driver
In Situ Temperature Measurement:
Test Overview
The sample was tested in the CSA Atlanta, GA lighting laboratory at a regulated and controlled ambient
temperature of 25°C ± 1°C
Data was taken on a Fluke 54II calibrated to ISO 17025
The sample was powered continuously from a conditioned 120.0V AC Source (60 Hertz).
Temperature data was recorded after 7 hours of operation (stabilization).
Tc was monitored using a J-Type thermocouple on the manufacturers designated temperature
measurement location as shown in the photographs above:
Equipment List: In Situ Temperature
Description Manufacturer and
Model Number
CSA Instrument
Reference Number Calibration Due Date
Temperature Indicator Fluke 54II TH109 8/2013
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 13 of 15
Continued…..
Photometric Testing Information
The sample was evaluated for photometric and electrical characteristics using an integrating sphere and a
goniophotometer, each located in purpose-built, temperature and humidity-controlled, draft free environments.
The integrating sphere is by Labsphere which exhibits a “4π geometry” configuration according to IES LM-79-
08 and is applicable for all types of LED products (directional and non-directional light projections). Its
spectroradiometer is an array-type detector manufactured and calibrated by Labsphere.
The integrating sphere uses self-absorption correction to eliminate errors due to mismatches between the
standard reference lamp and the test samples being measured. The auxiliary lamp used to perform this task is a
halogen type lamp powered by a calibrated Lamp Power Supply manufactured and calibrated by Labsphere.
Ambient temperature (for photometric analysis) is measured using a “J-Type” thermocouple located inside the
integrating sphere at the same height as the sample under test and not more than 1 meter in horizontal distance
away from the sample. The thermocouple is located behind the baffle of the photo detector in order to eliminate
any direct optical radiation from the sample under test.
Luminaire Stabilization.
The sample was placed inside the integrating sphere and powered by a regulated and conditioned Voltage
alternating current supply. The correlated color temperature, color rendering index, chromaticity coordinates
and electrical power measurements contained in this report are the numeric averages of the three readings upon
which stabilization is verified. The stabilization times shown on the results pages of this report denote the time
of the 1st measurement (of the 3 consecutive readings) since this is the minimum time that the sample is
assumed to have taken to reach stabilization.
The integrating sphere is calibrated using a quartzline halogen lamp with the following specifications:
Manufacturer: Sylvania
Model# 75Q/CL-28V
Voltage = 28.0 Volt
Wattage = 75.0 Watts
Calibration Current = 2.679 Amperes
Luminous Flux = 1538.8 Lumens
Calibration Date = 8-18-2005 (calibrated by Labsphere – NIST traceable).
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 14 of 15
Photometric Testing Information (continued)
The goniophotometer Mayer Engineering Type C is calibrated using a clear tungsten filament FDS/DZE lamp
with the following specifications:
Manufacturer: GE
Part Number: DZE 88
Bulb Number: 114-A
Voltage: 16.59 Volts DC reference
Calibration Current: 4.810 Amperes
Luminous Intensity: 154.7 Candelas
Calibration Date: 7/12/12 (NIST traceable)
Manufacturer: GE
Part Number: DZE 88
Bulb Number: 114-B
Voltage: 16.61 Volts DC reference
Calibration Current: 4.819 Amperes
Luminous Intensity: 150.6 Candelas
Calibration Date: 7/12/12(NIST traceable)
Manufacturer: GE
Part Number: DZE 88
Bulb Number: 114-C
Voltage: 16.66 Volts DC reference
Calibration Current: 4.815 Amperes
Luminous Intensity: 155.4 Candelas
Calibration Date: 7/12/12 (NIST traceable)
A Yokogawa WT210 Power Analyzer was used to measure all electrical characteristics of the sample.
CSA is an accredited Test Laboratory (TL-430)
to IESNA LM79-08 by IAS
(International Accreditation Service)
Report: 2594747
Project: 2594747
Client: Orb Optronix
6215 Shiloh Crossing This report shall not be reproduced, except in full, Telephone: 678-992-0134
Alpharetta, Georgia 30005 without the approval of CSA Group Fax: 770-500-3948
www.csagroup.com Page 15 of 15
All equipment is calibrated to ISO / IEC 17025-2005 guidelines.
Equipment List: Goniophotometer Type C (Mirror 1)
Description Manufacturer and
Model Number
CSA Instrument
Reference Number
Calibration Due
Date
Optometer Gigahertz Optik P9801 N/A N/A
Regulated Power Supply Chroma Instruments 61602P-
80-60 N/A N/A
Regulated Power Supply Chroma Instruments 61602 N/A N/A
Power Analyzer Yokogawa WT210 POA400 11/2013
Equipment List: Sphere C Equipment
Description Manufacturer and
Model Number
CSA Instrument
Reference Number
Calibration Due
Date
Integrating Sphere 76” Labsphere LMS760 SPH300 N/A
Spectroradiometer Labsphere CDS1100 CDS600C N/A
Auxiliary Lamp PSU Labsphere LPS100 LPS100 N/A
Power Analyzer Yokogawa WT210 PA112 1/2014
Regulated Power Supply Chroma Instruments 61603 AC302 N/A
Equipment List: In Situ Temperature
Thermometer
(Thermocouple) Fluke 54II TH109 8/2013