sanepar curitiba – brazil

34
SANEPAR Curitiba – Brazil Presented by: Erik Marnung Sales Manager Industry [email protected]

Upload: tavon

Post on 25-Feb-2016

48 views

Category:

Documents


0 download

DESCRIPTION

SANEPAR Curitiba – Brazil . Presented by: Erik Marnung Sales Manager Industry [email protected]. Content. 1. About Primozone 2. Ozone for filamentous sludge treatment 3 . Ozone for reduction of pharmaceutical residues . About Primozone. Founded in 2000, Sweden - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: SANEPAR  Curitiba – Brazil

SANEPAR Curitiba – Brazil

Presented by: Erik Marnung Sales Manager Industry

[email protected]

Page 2: SANEPAR  Curitiba – Brazil

Content

1. About Primozone

2. Ozone for filamentous sludge treatment

3. Ozone for reduction of pharmaceutical residues

Page 3: SANEPAR  Curitiba – Brazil

About PrimozoneFounded in 2000, SwedenIndustrial owner Westfal-Larsen Technology, NorwayFirst ozone installation in 2006 - now in 25+ countries on 5 continentsExperienced ozone provider – designs complete ozone solutionsR&D and production in-houseISO 9001 & 14001 certified

Page 4: SANEPAR  Curitiba – Brazil

A: Lund University, Water & Environmental TechnologyB: Primozone Production ABC: NSVAD: Aalborg University, Biotechnology

Filip NilssonA,B, Marinette HagmanC, Artur Tomasz MielczarekD

Per Halkjær NielsenD & Karin JönssonA

Application of Ozone in Full-Scale to Reduce Filamentous Bulking Sludge at Öresundsverket WWTP

Page 5: SANEPAR  Curitiba – Brazil

Bulking sludge is very common at WWTPs using activated sludge.Usual culprits in municipal WWTPs: Microthrix parvicella, Curvibacter and phyla TM7.Can cause:• Reduced settling• Decreased capacity• Reduced solids retention• Increased costs

Introduction

Page 6: SANEPAR  Curitiba – Brazil

Possible to remedy with:• Changing process parameters• Non-specific methods such as Ozone or PAX

However, care must be taken to safeguard the biological processes with either approach

Introduction

Page 7: SANEPAR  Curitiba – Brazil

Öresundsverket WWTP

• Commissioned in 1974, Helsingborg, Sweden

• Not uncommon with DSVI > 200 ml/g

• Designed for 220 000 PE (150 000 PE in 2012)

• Flow 70 000 m3/day or 1.85 MGD

• Largest Bio-P (EBPR) plant in Sweden

Page 8: SANEPAR  Curitiba – Brazil
Page 9: SANEPAR  Curitiba – Brazil
Page 10: SANEPAR  Curitiba – Brazil

Courtesy of: Salar Haghighatafshar, Lund University, SVU Report

• UCT Process, EBPR

Page 11: SANEPAR  Curitiba – Brazil

Anaerobic

Page 12: SANEPAR  Curitiba – Brazil

Aerobic

Page 13: SANEPAR  Curitiba – Brazil

Aim

Reduce the DSVI down to manageable levels with ozone in full-scale

Gain information on the bacterial population subjected to ozone treatment

Observe the Bio-P and nitrification processes during ozonation

Page 14: SANEPAR  Curitiba – Brazil

Full-Scale Ozone System

Page 15: SANEPAR  Curitiba – Brazil
Page 16: SANEPAR  Curitiba – Brazil
Page 17: SANEPAR  Curitiba – Brazil

Sampling

Operating parameters:• DSVI• VSS• Nitrification rate• Biological phosphorus release rate

Samples for Q-FISH and light microscopyAdditional samples:

• NH4-N• NO3-N• Total N• Total P

Page 18: SANEPAR  Curitiba – Brazil

Key Figures

• In operation for 45 days

• Ozone production 900 g O3 / hr

• Ozone concentration 200 g O3/Nm3 (13% wt)

• Ozone dose 2.8-5.0 g O3/kg SS

• 42 m3 return sludge / hr, ~5% (185 GPM)• ~11 minutes HRT @ 1.1-1.2 bar• 8 days production stop

Page 19: SANEPAR  Curitiba – Brazil

DSVI

-40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 5080

100

120

140

160

180

200

220Reference lineOzone line

Days into the study

DSV

I (m

l/g)

Page 20: SANEPAR  Curitiba – Brazil

Anaerobic

Page 21: SANEPAR  Curitiba – Brazil

Aerobic

Page 22: SANEPAR  Curitiba – Brazil
Page 23: SANEPAR  Curitiba – Brazil

0 5 10 15 20 25 30 35 40 45 501

1.5

2

2.5

3

3.5

4

4.5

5

Reference lineOzone line

Days into the study

Nitr

ifica

tion

rate

(mg

NH

4-N

/g V

SS*h

)Nitrification Rate

Page 24: SANEPAR  Curitiba – Brazil

0 5 10 15 20 25 30 35 40 45 500

2

4

6

8

10

12

0

2

4

6

8

10

12

14

16

18

Reference lineOzone lineTemp

Days into the study

Phos

phor

us re

leas

e ra

te (m

g PO

4-P/

g VS

S*h)

⁰C

Bio-P

Page 25: SANEPAR  Curitiba – Brazil

Conclusions

• The application of 2.8-5.0 g O3/kg SS in the return sludge can significantly reduce the DSVI of activated sludge.

• No adverse effect on neither Bio-P nor nitrification rate could be discerned.

Page 26: SANEPAR  Curitiba – Brazil

2. Ozone for reduction of pharmaceutical residues

Where do pharmaceuticals come from?Why is it a problem?Ozone and pharmaceuticalsPilot-scale results

Page 27: SANEPAR  Curitiba – Brazil

Pharmaceuticals found in wastewater

Type ExamplesPainkillers Codeine, Tramadol,

DiclofenacAnti-convulsant Carbamazepine

Anti depressants Citalopram, Bupropion

Anxiety repression Oxazepam

Heart disease Metoprolol, Irbesartran

Antibiotics Trimetoprim, Sulfomethoxazole

Estrogen Levonorgestrel

Page 28: SANEPAR  Curitiba – Brazil

Where do they come from?A large portion of the pharmaceuticals used in society ends up at wastewater treatment plants (WWTP).

•Individuals•Hospitals•Manufacturing•And others

Most of those are not removed at the WWTP and ends up in the discharge.From there it´s only a matter of time before they end up in the waterways.

Page 29: SANEPAR  Curitiba – Brazil

Why is it a problem?

Stable compounds (lingers in the water)Interactions with wildlifeCombinatory effects (pharmaceutical cocktail)Eventually they end up in the human biosphere again.

Page 30: SANEPAR  Curitiba – Brazil

Ozone and Pharmaceuticals

Ozone attacks electronegative areas and breaks up the molecule into smaller pieces.

The resulting compounds are much more biodegradable in sand filters and the like.

Page 31: SANEPAR  Curitiba – Brazil

Pilot-scale experiment

Lundåkraverket WWTP 2012, Landskrona, Sweden

Page 32: SANEPAR  Curitiba – Brazil

Pilot-scale experiment

Page 33: SANEPAR  Curitiba – Brazil

Results of pilot-scale test

Ozone dose (g/m3)

Reduction (%)

Ozone before filter 10µm

Ozone after filter 10µm

2 10% 48%

5 80% 95%

9 88% 97%

• 24/46 compounds were found consistently

Page 34: SANEPAR  Curitiba – Brazil

Thank you!