Sanuvox Technologies Inc, © 2020 All rights reserved. August 2020 EN v.4 Instruction Manual Photos illustrating products are non contractual. SANUVAIR ® S100 AIR PURIFICATION UNIT Commercial Model IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT. Read and follow all instructions contained in this manual before using the product. Failure to comply with these instructions may result in personal injuries or damage to the unit or system. 1. Installation and servicing of air conditioning and related equipment can be hazardous due to systems pressure and electrical components. Only trained and qualified service personnel should install, repair or service equipment. 2. Untrained personnel can perform basic maintenance functions such as replacing lamp(s) and/or filter(s). All other operations should be performed by trained service personnel. 3. When working on the unit or system, observe precautions in the literature, tags and labels attached to the unit or system, and all other safety precautions considered as best practices in the HVAC industry. 4. When applicable, local regulation may comprise more restrictive installation and/or certification requirements. The afore mentioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense. 5. Follow all the safety instructions outlined in this document and respect all local and national codes applicable. 6. Never expose eyes or skin to ultraviolet light from any source. Therefore, before installing or performing maintenance on the unit or system, TURN OFF AND DISCONNECT the unit or system from all power sources (there may be more than one switch to disconnect). CAUTION: Electrical shock may cause personal injuries or possibly death. 7. UV rays may destroy certain types of filters (polymer or plastic); please keep the unit or system light away from shining directly on plastic. 8. When installing or performing maintenance on the UV unit or system, it is recommended to wear safety glasses and gloves. In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves. 9. UV lamps contain a small quantity of mercury: if a lamp breaks, clean and dispose of with care. UV lamps can be disposed/recycled after use, as any other fluorescent lamps. Contact and follow your local and national authorities’ specific instructions. 10. Use only specified SANUVOX branded replacement UV lamps with your unit or system. Use of any other lamps will void your warranty and can result in damage to the unit, system and/or lamp(s). 11. Most UV units or systems are not waterproof. DO NOT INSTALL OUTDOORS unless specified otherwise. SAVE THESE INSTRUCTIONS Installation Date: _______________ Installed by: _________________ Installer Contact Info.: _________________________________________ REGISTER YOUR WARRANTY ONLINE AT www.sanuvox.com

Upload: others

Post on 30-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Sanuvox Technologies Inc, © 2020 All rights reserved. August 2020 EN v.4

    Instruction Manual

    Phot

    os il

    lust

    ratin

    g pr

    oduc

    ts a

    re n

    on c

    ontra

    ctua

    l.

    SANUVAIR® S100AIR PURIFICATION UNIT

    Commercial Model

    IMPORTANT SAFETY INSTRUCTIONSREAD AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.

    Read and follow all instructions contained in this manual before using the product. Failure to comply with these instructions may result in personal injuries or damage to the unit or system.

    1. Installation and servicing of air conditioning and related equipment can be hazardous due to systems pressure and electrical components. Only trained and qualified service personnel should install, repair or service equipment.

    2. Untrained personnel can perform basic maintenance functions such as replacing lamp(s) and/or filter(s). All other operations should be performed by trained service personnel.

    3. When working on the unit or system, observe precautions in the literature, tags and labels attached to the unit or system, and all other safety precautions considered as best practices in the HVAC industry.

    4. When applicable, local regulation may comprise more restrictive installation and/or certification requirements. The afore mentioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense.

    5. Follow all the safety instructions outlined in this document and respect all local and national codes applicable.

    6. Never expose eyes or skin to ultraviolet light from any source. Therefore, before installing or performing maintenance on the unit or system, TURN OFF AND DISCONNECT the unit or system from all power sources (there may be more than one switch to disconnect).

    CAUTION: Electrical shock may cause personal injuries or possibly death.

    7. UV rays may destroy certain types of filters (polymer or plastic); please keep the unit or system light away from shining directly on plastic.

    8. When installing or performing maintenance on the UV unit or system, it is recommended to wear safety glasses and gloves. In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.

    9. UV lamps contain a small quantity of mercury: if a lamp breaks, clean and dispose of with care. UV lamps can be disposed/recycled after use, as any other fluorescent lamps. Contact and follow your local and national authorities’ specific instructions.

    10. Use only specified SANUVOX branded replacement UV lamps with your unit or system. Use of any other lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

    11. Most UV units or systems are not waterproof. DO NOT INSTALL OUTDOORS unless specified otherwise.

    SAVE THESE INSTRUCTIONS

    Installation Date: _______________ Installed by: _________________Installer Contact Info.: _________________________________________

    REGISTER YOUR WARRANTY

    ONLINE AT www.sanuvox.com

  • 2

    Instruction Manual for SANUVAIR® S100

    1-888-726-8869www.sanuvox.com

    TABLE OF CONTENTS

    IMPORTANT SAFETY INSTRUCTIONS 1TABLE OF CONTENTS 2ABOUT THE PRODUCT 3COMPONENTS 3 How it Works 3SETUP & INSTALLATION 3 What you will need 3 What’s included 3 Versatile Installations 4 Step by Step Setup & Installation - Ceiling-Mounted 4 Step by Step Setup & Installation - Wall-Mounted 6OPERATION 7 How to Operate your Product 7MAINTENANCE 8 How to Replace Lamp(s) 8 Step by Step Lamp Replacement 8 How to Clean your Product 9 Step by Step Filter Cleaning 9STORAGE 10ULTRAVIOLETS: UVV & UVC 10ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE 10TROUBLESHOOTING 10 What you will need 10 Problems & Solutions Table 10 Step by Step UV Lamp Continuity Test 11WARRANTY 12CUSTOMER SERVICE 12

  • A

    BD

    FE

    G

    H

    C

    3

    Instruction Manual for SANUVAIR® S100

    1-888-726-8869www.sanuvox.com

    ABOUT THE PRODUCT

    Congratulations on the purchase of your new Sanuvox UV air purifier. Sanuvox UV air purifiers are the most advanced air purification systems available, having been proven to destroy up to 99.99% of biological and chemical contaminants that circulate throughout the air of your home or facility. Sanuvox systems have been tested by the EPA (Environmental Protection Agency), the National Homeland Security research center, medical universities and independent third party laboratories.

    For information or recommendations on how to size your specific application, please call SANUVOX at 1-888-726-8869.

    COMPONENTS

    How it WorksThe Sanuvox SANUVAIR® S100 unit is designed to destroy biological and chemical contaminants. The air purifier can be installed in a suspended celling or on a wall. An internal fan circulates air through the air purifier. The SANUVAIR® S100 is designed to treat up to 500 square feet of space (per unit).

    A. Air inlet ventB. Filter door (with mesh)C. Security switchD. FilterE. UV LampF. FanG. Unit coverH. Air outlet vent

    SETUP & INSTALLATION

    What you will needA utility knife to unpack all components, a stepladder to reach the celling or wall properly, a Phillips No.2 screwdriver, a measuring tape, a level, a marker, and a cutter or saw (if ceiling-mounted).

    CAUTION: Handle your product with care to avoid breaking parts. Make sure you have a free and safe space to unpack, install and setup your product. Confirm you have access to the necessary power source for the product requirements (see unit or system label). If you have any questions regarding the installation instructions, call SANUVOX at 1-888-726-8869.

    What’s includedThe SANUVAIR® S100, a UV lamp and a basic installation kit.

    The installation kit includes: a pair of cotton gloves, 8-32 screws (3), a transformer, a power cord (US or EUR), an elbow adapter, an angled support bracket and a near-horizontal support bracket.

  • A

    AB

    B

    4

    Instruction Manual for SANUVAIR® S100

    1-888-726-8869www.sanuvox.com

    Versatile InstallationsThe SANUVAIR® S100 unit can be installed two ways: ceiling-mounted in a 24" x 14" area of a suspended ceiling at least 8" deep OR simply wall-mounted.

    Either way, make sure there is adequate clearance (at least 2 feet) for the door to swing down for maintenance or service.

    CAUTION: The adapter cannot be installed in a dry wall ceiling. This unit cannot be approved as a medical system. Use only with adapter PSAC60M-120. Use only with lamp LMPRGXJ65.

    Step by Step Setup & Installation - Ceiling-Mounted

    1. Check installation location of the unit, so that there is at least 24" from the wall in order to have good air circulation.

    Also make sure you have access to a 110V (or 230V) input to power the unit.

    2. Prepare unit for installation: Take the unit out of its box and install the support anchors required to support the unit by screwing them directly to the unit.

    A. Sliding door side : near-horizontal support bracket. B. Beveled side (mesh) : angled support bracket.

    Then lay the unit on a flat surface with the access doors facing up.

    NOTE: Keep box in case of return under warranty.

    STEP 1

    STEP 2

    STEP 55. Install lamp: Open the unit by sliding its cover to gain access to the lamp

    location. Connect the lamp to the connector (only one way possible) and gently attach it to the lamp holder.

    NOTE: Lamp must be installed over the stopper.

    3. Prepare for UV lamp installation: remove lamp from packaging. Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve.

    4. Carefully slide the UV lamp out from the cardboard sleeve. Be sure to wear the cotton gloves (included) guaranteeing a clean lamp free from fingerprints.

    NOTE: Fingerprints on the lamp will negatively impact the UV output of the lamp.

    STEP 3

    STEP 4

    min. 24"

    Access Doors

  • 5

    Instruction Manual for SANUVAIR® S100

    1-888-726-8869www.sanuvox.com

    8. Now, prepare location for installation: Cut a 24" x 14" opening in a suspended ceiling tile to install the unit. In order to facilitate the work, remove 14" lengthwise.

    9. Connect the power supply to the adapter, and the adapter to the unit.

    NOTE: Once connected, the unit will turn on automatically. Continue with the installation while the unit is running.

    STEP 8

    STEP 9

    STEP 10

    STEP 11

    10. Make sure to position the unit so that the air outlet (open end) is at least 24" from the wall.

    Pass the unit through the ceiling (tilt it slightly to the side) and gently lean the device support anchors against the tile and the ceiling support.

    11. Replace the cut part of the suspended ceiling tile to hide the opening. Then, right up against the unit, install a 24" ‘T’ bracket.

    Your new SANUVAIR® S100 is now ready to operate so you can enjoy great air quality

    for you and your colleagues.

    6. Install Filter: While the unit cover is still open, pull on the non-mesh end to gain access to the filter location (mesh door). Take the filter out of its packaging and install it in the unit. Close the mesh door properly.

    7. Adjust the fan speed: While the unit cover is still open, you will have access to the speed controller. For best results, choose “Hi” and for quieter use, choose “Low”.

    Once the lamp and filter are installed and the fan settings are adjusted to your liking, make sure to close the unit cover properly.

    STEP 7

    STEP 6

  • 6

    Instruction Manual for SANUVAIR® S100

    1-888-726-8869www.sanuvox.com

    Step by Step Setup & Installation - Wall-Mounted

    1. Check installation location of the unit, so that there is at least 24" from the ceiling in order to have good air circulation.

    Also make sure you have access to a 110V (or 230V) input to power the unit.

    STEP 1

    2. Prepare unit for installation: Take the unit out of its box and lay the unit on a flat surface with the access doors facing up.

    NOTE: Keep box in case of return under warranty.

    STEP 2

    3. Prepare for UV lamp installation: remove lamp from packaging. Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve.

    4. Carefully slide the UV lamp out from the cardboard sleeve. Be sure to wear the cotton gloves (included) guaranteeing a clean lamp free from fingerprints.

    NOTE: Fingerprints on the lamp will negatively impact the UV output of the lamp.

    STEP 3

    STEP 4

    STEP 5

    STEP 6

    5. Install lamp: Open the unit by sliding its cover to gain access to the lamp location. Connect the lamp to the connector (only one way possible) and gently attach it to the lamp holder.

    NOTE: Lamp must be installed over the stopper.

    6. Install Filter: While the unit cover is still open, pull on the non-mesh end to gain access to the filter location (mesh door). Take the filter out of its packaging and install it in the unit. Close the mesh door properly.

    min. 24"

  • 7

    Instruction Manual for SANUVAIR® S100

    1-888-726-8869www.sanuvox.com

    8. Now, prepare location for installation: Mark wall and screw in support screw at proper height.

    Then, hang the unit on the wall on the support screw.

    STEP 8

    9. Connect the power supply to the adapter, and the adapter to the unit. For a wall installation, you will need to use the 90° adapter.

    NOTE: Once connected, the unit will turn on automatically.

    Your new SANUVAIR® S100 is now ready to operate so you can enjoy great air quality

    for you and your colleagues.

    STEP 9

    STEP 77. Adjust the fan speed: While the unit cover is still open, you will have

    access to the speed controller. For best results, choose “Hi” and for quieter use, choose “Low”.

    Once the lamp and filter are installed and the fan settings are adjusted to your liking, make sure to close the unit cover properly.

    OPERATION

    How to Operate your Product

    If wired directly to a dedicated power source, the SANUVAIR® S100 will operate continuously. If wired in parallel with other devices, such as overhead lighting, the SANUVAIR® S100 will operate only when the circuit is energized. The internal fan circulates air through the device. Room air is drawn in through the polypropylene filter and passes by the ultraviolet lamp. Then, the purified air is being exhausted. A safety switch is provided to stop operation if the cover is opened.

    Do not hold down security switch when cover is open. The ultraviolet lamp will energize, which may cause injury to eyes and exposed skin. Never expose eyes or skin to direct UV light.

    CAUTION: The suggested operating temperature range is 50°F to 115°F (10°C to 46°C). Operating the SANUVAIR® S100 outside this range will result in decreased performance.

  • 8

    Instruction Manual for SANUVAIR® S100

    1-888-726-8869www.sanuvox.com

    MAINTENANCE

    How to Replace Lamp(s)

    Replacing lamps on the SANUVAIR® S100 needs to be done periodically to maintain design specifications. The UV lamp can function for many years, but over time, the UV wavelength does decrease. For best results, the UV lamp should be replaced every two years guaranteeing the highest performance.

    CAUTION: In order to avoid reduced performance of lamp(s), do not touch lamp glass without gloves.

    Step by Step Lamp Replacement

    Example for a ceiling-mounted unit. The same step by step process applies for a wall-mounted unit.

    NOTE: The lamp can be replaced while the unit is installed on the ceiling or wall. Another option is to remove the unit from the ceiling or wall, and then replace the lamp with the unit lying on a flat surface with the access doors facing up. Besides, this option is preferable for a wall unit.

    1. Open the unit by sliding down its cover to gain access to the lamp location.

    3. Prepare the new lamp. Remove the contents from packaging. Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve.

    4. Carefully slide the new UV lamp out from the cardboard sleeve. Be sure to wear the cotton gloves (included) guaranteeing a clean lamp free from fingerprints.

    NOTE: Fingerprints on the lamp will negatively impact the UV output of the lamp.

    STEP 1

    STEP 3

    STEP 4

    2. Open the clamp. Disconnect the old UV lamp from the connector and remove the lamp from the unit.

    NOTE: UV lamps can be disposed/recycled after use, as any other fluorescent lamps. Contact and follow your local and national authorities’ specific instructions.

    6. Close the unit cover properly.

    5. Connect the lamp to the connector (only one way possible) and gently attach it into the lamp clamp.

    NOTE: Lamp must be installed over the stopper.

    STEP 2

    STEP 6

    STEP 5

  • 9

    Instruction Manual for SANUVAIR® S100

    1-888-726-8869www.sanuvox.com

    How to Clean your Product

    There is very little maintenance to be done on the SANUVAIR® S100.

    Periodic cleaning of the inlet filter may be performed. Filter media should be cleaned at least once every 6 months for optimal performance to be kept free of dust and residue deposit. Clean when necessary with mild soap or rubbing alcohol.

    To clean the unit exterior, use a damp cloth with general purpose detergent. Always spot test the cleaner to make sure it does not damage the surface.

    CAUTION: Under no circumstance should water be sprayed or splashed onto the product.

    Step by Step Filter Cleaning

    Example for a wall-mounted unit. The same step by step process applies for a ceiling-mounted unit.

    NOTE: The filter can be removed for cleaning while the unit is installed on the ceiling or wall. Another option is to remove the unit from the ceiling or wall, and then access the filter with the unit lying on a flat surface with the access doors facing up. Besides, this option is preferable for a wall unit.

    1. Open the unit by sliding down its cover and pull on the non-mesh end of the filter door to gain access to the filter location.

    CAUTION: When unit is wall-mounted, its cover may slide down

    if not properly locked on open. When you slide the unit cover up, make sure to push it up and toward the wall until it clips in place and stays up on its own.

    STEP 1

    2. Remove the filter and and clean it.

    NOTE: The filter can be washed with mild soap or rubbing alcohol.

    4. Close the filter door and the unit cover properly.

    NOTE: To unlock and slide down the unit cover when the unit is wall-mounted, pull the unit cover toward you and down. Make sure to close the unit cover for the unit to restart.

    3. When filter is dry, reinstall it in the unit.

    STEP 2

    STEP 4

    STEP 3

    The cover must clip in place inside the unit

    A. B.

  • 10

    Instruction Manual for SANUVAIR® S100

    1-888-726-8869www.sanuvox.com

    ULTRAVIOLETS: UVV & UVC

    The UVC (254 nm) and UVV (185 nm) light produced by Sanuvox UV units and systems are the same two UV wavelengths produced by the Sun. The UVC wavelength attacks the micro-organisms on a molecular level deactivating and destroying the contaminants, while the UVV wavelength degrades the chemicals and odors. Unlike conventional UV lamps on the market, Sanuvox UV units and systems use a patented process designed to deliver the maximum UV dosage to the moving air-stream or surface.

    CAUTION: Never expose eyes or skin to ultraviolet light from any source.

    STORAGE

    The SANUVAIR® S100 is a ceiling or wall-mounted unit working continuously and automatically and therefore, requires no specific storage.

    ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE

    The SANUVAIR® S100 has a power consumption of 25 Watts and requires a 12V 60Hz power source.See product label to confirm power consumption of your specific unit or system.

    NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

    TROUBLESHOOTING

    If your product is not working properly, refer to the following.

    What you will needA stepladder to reach to celling or wall properly and an ohmmeter.

    Problem Possible Cause SolutionYou cannot see the “glow" of the UV lamp through the outlet louvers

    - The lamp has failed - Check the wire connections to the ballast and lamp (plug).

    - Check lamp continuity. See UV Lamp Continuity Test instructions on page 11.

    - Replace lampThe unit has no power - Connections were not properly done - Check and verify that all wire

    connections are properly plugged- The ballast has failed - Replace ballast

    The fan is not working - Connections were not properly done - Check and verify that all wire connections are properly plugged

    - The fan has failed - Contact your contractor or Sanuvox customer service for assitance

    - The speed controller has failed - Contact your contractor or Sanuvox customer service for assitance

    The unit is making loud noise - The fan or motor has failed - Contact your contractor or Sanuvox customer service for assitance

    Contact your contractor for all your needs in terms of replacement parts: cover, ballast, UV lamp, etc.

  • 11

    Instruction Manual for SANUVAIR® S100

    1-888-726-8869www.sanuvox.com

    Step by Step UV Lamp Continuity Test

    Example for a ceiling-mounted unit. The same step by step process applies for a wall-mounted unit.

    NOTE: Its possible to access the lamp while the unit is installed on the ceiling or wall. Another option is to remove the unit from the ceiling or wall, and then access the lamp with the unit lying on a flat surface with the access doors facing up. Besides, this option is preferable for a wall unit.

    1. Open the unit by sliding down its cover to gain access to the lamp location.

    3. Using an ohmmeter place 1 probe on 1 of the 4 pins and by sensing the 3 remaining pins, one should have continuity. Make sure the 2 remaining pins also have continuity. When both sets of pins test good for continuity, it can be assumed that the lamp is good.

    STEP 1

    STEP 3

    2. Open the clamp. Disconnect the old UV lamp from the connector and remove the lamp from the unit.

    NOTE: Fingerprints on the lamp will negatively impact the UV output of the lamp. Always use cotton gloves to manipulate UV lamps.

    STEP 2

  • 12

    Instruction Manual for SANUVAIR® S100

    1-888-726-8869www.sanuvox.com

    WARRANTY

    You should first read all instructions before attempting to use this product.For this warranty to be valid, keep a copy of the proof of purchase.

    UV lamp 2 yearsBallast 3 yearsFan 1 year

    A. This limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.

    SANUVOX IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.

    Some jurisdictions do not allow the exclusion or limitation of incidential or consequential damages or limitation on how long an implied warranty last, so the above limitations or exclusions may not apply to you. This warranty gives specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

    B. At its option, SANUVOX will repair or replace this product if it is found to be defective in material or workmanship.C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.D. This warranty does not cover the filters, pre-filters or other accessories (if included), except for material or workmanship defects.

    Call us toll-free at 1-888-726-8869 or email: [email protected] be sure to specify product name.NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY. DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST. DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT.

    CUSTOMER SERVICE

    FOR ASSISTANCE WITH TROUBLESHOOTINGPLEASE CONTACT YOUR CONTRACTOR OR SANUVOX TECHNICAL SUPPORTToll-Free Phone #: 1-888-726-8869Email: [email protected]: www.sanuvox.comPlease be sure to specify product name.

    TO ORDER REPLACEMENT PARTSPLEASE CONTACT YOUR CONTRACTOR OR SANUVOX PURCHASING DEPARTMENTToll-Free Phone #: 1-888-726-8869Email: [email protected]: www.sanuvox.comPlease be sure to specify product name.

    Replacement parts for this productBST12G12 110 V ballastLMPRGXJ65 T6 dual zone 6.5" UV ‘J’ lamp

    WARNING: Use only specified SANUVOX branded replacement UV lamps with your unit or system. Use of any other lamps will void your warranty and can result in damage to the unit, system and/or lamp(s).

    REGISTER YOUR WARRANTY