sas-sistem de control
DESCRIPTION
Sistem de control digital pentru aplicatii electrice-PacisTRANSCRIPT
![Page 1: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/1.jpg)
![Page 2: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/2.jpg)
Digital Control System for Electrical applicationPACiS
Alain Roux
Sibiu, May 2009
South Europe Sales ManagerBogdan Ianculescu
Commercial Manager Romania
![Page 3: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/3.jpg)
PACiS Application markets
UTILITIESSUBSTATIONS
INDUSTRIALPLANTS
> PACiS short EN – 20/05/08- Issue H3 3
DISTRIBUTEDGENERATION INFRA-
STRUCTURES
![Page 4: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/4.jpg)
PACiS : First IEC61850 Solution
2002 PACiS projects
More than 509 PACiS since 2002
2003 PACiS projects 2007 PACiS projects
2006 PACiS projects
2005 PACiS projects
2004 PACiS projects 2008 PACiS projects
> PACiS short EN – 20/05/08- Issue H4 4
![Page 5: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/5.jpg)
PACiS Application Areas
�
300 V upto 800 kV
GREEN FIELD & RETROFIT
FAST LOAD SHEDDING,VOLTAGE REGULATION,
SYNCHRO-CHECK
> PACiS short EN – 20/05/08- Issue H5 5
AIS & GIS
INDOOR & OUTDOOR
�AREVA TURNKEY
& LOOSE DELIVERY
![Page 6: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/6.jpg)
Introducing PACiS: Concepts
SCALABLE SOLUTIONScope, Functions, Architecture, Engineering
> PACiS short EN – 20/05/08- Issue H6 6
HIGH STANDARDIZATIONLEVEL
Communication, Bay/Substation, Services
DEDICATED TO POWER AUTOMATION
Security, Topological automation, Smooth evolutions, Outage optimization
![Page 7: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/7.jpg)
PACiS: A scalable solution
�Network
�Site
�Substation
� M + C + P +
Power
Management
SCOPE FUNCTIONS
> PACiS short EN – 20/05/08- Issue H7 7
�Substation
�Voltage level
�Busbar
�Bay
� M + C +
Protection
� M + Control
� Monitoring
![Page 8: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/8.jpg)
High standardization level
�Communications� IEC 61850, IEC60870-5-101,103, 104,
DNP3 & DNP3/IP, MODBUS
�Automation Schemes
> PACiS short EN – 20/05/08- Issue H8 8
�Automation Schemes� IEC 61131-3
�Engineering & Service
Lifetime Cost & Lead Time optimization
![Page 9: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/9.jpg)
Introducing PACiS: Components
IEDsProtections, Computers, Measurement
> PACiS short EN – 20/05/08- Issue H9 9
SOFTWAREEngineering tools, SCADA
COMMUNICATIONSwitches, Gateways
![Page 10: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/10.jpg)
AN UNRIVALED IEDs BASIS
MiCOM C264/C264P: Bay Computer, RTU,Feeder Protection, Automatic Voltage Regulator
MiCOM A300 : Solid State PC
> PACiS short EN – 20/05/08- Issue H10 10
Feeder Protection, Automatic Voltage Regulator
MiCOM Mxxx: Measurement & DisturbanceRecorders
MiCOM Hxxx: Manageable Ethernet Switchs
MiCOM Pxxx: Protection Relays
MiCOM Txxx: Telecoms units
![Page 11: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/11.jpg)
MiCOM A300 : PACiS GATEWAYS
Ensure data exchange with the EMS� Serial and Ethernet ports
� Integrated Ethernet switch
� Hot stand-by redundancy
� Fully configured within PACiS SCE
> PACiS short EN – 20/05/08- Issue H11 11
� Fully configured within PACiS SCE
� PC base solutionwithout rotating part (XPe)
� Fully compliant with Electricalinstallation constraints(IEC 60255 & IEC 1004)
Give the right information to the process
![Page 12: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/12.jpg)
MiCOM Hxx MANAGEABLE ETHERNET SWITCHES
Complete MiCOM H range � All Ethernet network architecture
� Star, � Redundant ring� Dual attachment
� SNMP management features� Single and multi-mode 10/100 Mbps
> PACiS short EN – 20/05/08- Issue H12 12
� Single and multi-mode 10/100 Mbps� DIN- rail case with redundant
power supply 24/48/60/110/220 Vcc �Fully compliant with Electrical
installation constraints (IEC 60255 & IEC 1004)
�Also as a PCI board (PC integration) or board for C264
Benefit from the protection relay world reliability
![Page 13: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/13.jpg)
MiCOM C264: The Bay Computer
� Bay controller� IEDs gateway� RTU/Gateway� Data Concentrator� PLC� MV Feeder Protection� SER Events recorder
> PACiS short EN – 20/05/08- Issue H13 13
MiCOM C264 modular bay computer hasthe same design as the MiCOM relay series.
� SER Events recorder� Waveform/Disturbance
recorder� Automatic Voltage
Regulator� Ethernet switch
![Page 14: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/14.jpg)
MiCOM C264 Communications
� Up to 6 Ethernet Ports FX or TX
� Single star
� Redundant ring
� Dual star (double attachment)
� SCADA communication :IEC 61850 Server, IEC 60870-5-104, DNP3.0 Level 3/TCP, MODBUS RTU/TCP
� IED communication :IEC 61850 Client
> PACiS short EN – 20/05/08- Issue H14 14
� Up to 4 Serial Communication Ports (Master or Slave Selectable)
� SCADA communication :IEC 60870-5-101, DNP3.0 Level 3, MODBUS RTU, HNZ
� IED legacy communication :IEC 60870-5-103, Modbus RTU, IEC 60870-5-101, DNP3.0 Level 2
� Local Event printer
![Page 15: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/15.jpg)
MiCOM C264P : MV Feeder protection
�IEC 61850 MV Feeder OBS�1 ms time tagging�Dedicated Protection CPU�IED Data Concentrator�PLC IEC61131-3
Busbar
Trip
Earth CT
Phase CTs
1 Phase BB VT
67N
81O
MiCOM C264-P
Logic outputs
Logic inputs
59N
81U
37
50
79
50N51N67
52
Analog inputs
> PACiS short EN – 20/05/08- Issue H15 15
�PLC IEC61131-3�SER Events recorder�Disturbance
recorder�Embedded Ethernet switch
Earth CT
Legacy comm.
67N
2732NRS 485/RS232/RS42250
51
50BF
IEC61850
81R
46
59
Analog outputs
3 PhasesVTs
MiCOM C264P MV OBS has the same IOs boardsas the MiCOM C264
![Page 16: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/16.jpg)
�70 series: M871, M872 (modular) M571, M572 (compact)
Network monitoring solution
Recording � Disturbance
� Trend
� Power Quality
� Measures
� Transducer
� SCADA interface
> PACiS short EN – 20/05/08- Issue H16 16
�Analysis and management softwareDatabase records management, record analysis, report generation.
� SCADA interface
![Page 17: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/17.jpg)
� Measurement Centres. M2x3 Range
�MiCOM M233 – Basic Measurement centre
Measurement Centres
� Measures
� Tariff registers
� Digital display
MMC
> PACiS short EN – 20/05/08- Issue H17 17
�MiCOM M243 and M253 : Measurement Centre with embedded limited recording functions.
MMC
� Measures
� Tariff register
� Recording
� Digital and graphic display
![Page 18: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/18.jpg)
MiCOM P portfolioP900 Frequency Protection Relay
P800 Autoreclose Relays
P700 Busbar Protection Relays
P600 Transformer Protection
P500 Line Differential Relays
P400 Distance Protection Relays
> PACiS short EN – 20/05/08- Issue H18 18
P100 Feeder Management Relays
P400 Distance Protection Relays
P300 Generator Protection Relay
P200 Universal Motor Protection
Generation Transmission Distribution Indep.producer
![Page 19: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/19.jpg)
MiCOM Relays
P630
Generation
Transmission
Industry
P220P120
P240
P140
P340P940 P920
P540 P140P440
P630
P340
P139
P740
> PACiS short EN – 20/05/08- Issue H19 19
MiCOM realys cover all areas of the power system
Low Voltage
Distribution
Home
P120
P140
P630
P130
P210
P110
![Page 20: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/20.jpg)
MiCOM Relays Hardware & Software Platform
Feeder Feeder Motor Motor GeneratorGenerator FreqFreqDistanceDistance IIDiff.Diff.
Transf. Transf. Diff.Diff.
B.B.B.B.Diff.Diff.
CBF CBF
61850 61850 61850 61850
> PACiS short EN – 20/05/08- Issue H20 20
P 14x P 24x
P 22x
P 94x
P 13x
P 34x
P 12x P 92xP 22x
P 44x
P 43x
P 54x
Px20
P 63x
P 52x
P 74x
P 82x
P 64x
P 72x
P 84x
61850 61850 61850
61850 6185061850
![Page 21: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/21.jpg)
MiCOM Telecom Solutions
RTUdistance protection
Differential protection
RTUdistance protection
Differential protectionTeleprotection TeleprotectionPLC T390
Ethernet Subs bus
Ethernet Subs bus
� Universal Power Line carrier MiCOM T390
� Multiplexers, Tele-protections DCX5000, DIP 5000
� Telecom Management system
> PACiS short EN – 20/05/08- Issue H21 21
SDH
Telecom Management MUX MUX
![Page 22: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/22.jpg)
Introducing PACiS: Components
IEDsProtections, Computers, Measurement
> PACiS short EN – 20/05/08- Issue H22 22
SOFTWAREEngineering tools, SCADA
COMMUNICATIONSwitches, Gateways
![Page 23: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/23.jpg)
PACiS software
�Local Human Machine Interface :
� PACiS OI single or redundant servers
� Up to 8 PACiS OI local or remote clients
> PACiS short EN – 20/05/08- Issue H23 23
�Engineering tools :
� System Configurator Editor : PACiS SCE
� System Maintenance Tools : PACiS SMT
� MiCOM C264 Remote Maintenance – C264 WEB Server
� MiCOM S1 – C264P Protection parameters
![Page 24: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/24.jpg)
PACiS HMI :Advanced SCADA features
Substation screens� Control & Command
Primary equipments� Alarm & Event viewer� Measurements� Trend viewer� Video inclusion
> PACiS short EN – 20/05/08- Issue H24 24
Alarm windows� Most recent
alarms� Nature, Status,
Severity, Timestamping 1 ms
� Up to 6 differentAlarm levels
� Up to 8 independent PACiS users� WEB access for remote control� Complete redundancy
![Page 25: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/25.jpg)
PACiS HMI : Alarm/State/Event browsers
Event list� 1ms datation � Customisable� Colors indication
Event sorter� Logic
condition
> PACiS short EN – 20/05/08- Issue H25 25
Events browser� Tree
presentation� Event per
device � Icon
identification
condition� Name� Date or time� Device� Bay� Voltage level
![Page 26: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/26.jpg)
PACiS Engineering tools
� System Configurator Editor - PACiS SCE
� System Management Tool - PACiS SMT
� C264 Remote Maintenance – C264 WEB Server
> PACiS short EN – 20/05/08- Issue H26 26
� C264 Remote Maintenance – C264 WEB Server
� MiCOM S1 – C264P Protection parameters
Simplify and Secure Customer engineering
![Page 27: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/27.jpg)
PACiS System Configurator Editor Objectives
� DATA CONSITENCY: � between domains (communication, HMI, graphical, automation, etc.)
� between devices (HMI, gateway, bay computer, protections, etc)
� LARGE DATA FLOWS:
� More data than with legacy communication protocols
� More flows (client/servers, peer-to-peer), not only master slave
> PACiS short EN – 20/05/08- Issue H27 27
An essential tool for modern Substation Automation Systems
� LIFE CYCLE APPROACH
� Manage evolutions during the system life
� Handle legacy devices
� EASE OF USE
� Implicit processing (data, logic)
� No need to be an IEC 61850 expert
![Page 28: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/28.jpg)
PACiS SCE : Data consistency
4 Domains in 1 Tool
Electrical Part
System Part
EDITORSObject oriented with hierarchical domain approach in line with IEC 61850 hierarchy
Key features
Create/Delete Relations (bindings) between domains
Template management (per
> PACiS short EN – 20/05/08- Issue H28 28
A single tool
System Part
Graphical Part
Automation Part
Template management (per domain and composite)
Check per editor and global(completion, consistency)
![Page 29: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/29.jpg)
PACiS SCE : Large volume of data handling
Graphical template example
Instances
CB1CB2
CB3
Automatic
CB1CB2
CB3
Evolution
TEMPLATES
A template can be made ofGraphical, Electrical, System and
Automation domains. It might be imported (typ. An IED)
> PACiS short EN – 20/05/08- Issue H29 29
Industrial approach
QUERIES
Database onMultiple criteria
![Page 30: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/30.jpg)
PACiS System Management Tool
� Management Configuration database downloadto PACiS equipment (HMI, IEDs)
� Ensure coherency between the ConfigurationDatabases
System Management Tool functions:
> PACiS short EN – 20/05/08- Issue H30 30
Databases
� Store the Configuration Database versions
� Allows upload of Waveform/Disturbance records
![Page 31: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/31.jpg)
MiCOM C264 – Maintenance Web Server
� Access from Internet Browser (Mozilla Fox or IE) with user + password
� Visualisation of Bay Maintenance data :
> PACiS short EN – 20/05/08- Issue H31 31
�MiCOM C264 Hard & Soft Status,
� I/O status,
�Sequence of 2 000 Time stamped stored Events,
� Instantaneous reports (Measures, Counters, Binary Inputs, Status list)
�Legacy IEDs status
![Page 32: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/32.jpg)
MiCOM S1 - MiCOM Protection setting software
� Upload and download of MiCOM C & P protection parameters
� On-line and Off-line modification of the models
� Connectionvia the Ethernet network
> PACiS short EN – 20/05/08- Issue H32 32
� Available in various languages:
�English,
�French,
�Spanish
�German
![Page 33: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/33.jpg)
PACiS Automation schemes
� Pre-designed automation schemes� MiCOM C264 level
� Automatic Voltage Regulator� Synchro-check� Autorecloser
� PACiS application level � Fast Load shedding for Large industry and Oil & Gaz
> PACiS short EN – 20/05/08- Issue H33 33
� Fast Load shedding for Large industry and Oil & Gaz� Interlocking
� Personnalized automation schemes � Using the IEC61850 GOOSE peer-to-peer fast data
transfert capabilities� Programmable Scheme Logic� IEC61131-3 automatism language (ISAGRAF)
![Page 34: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/34.jpg)
MiCOM C264 – Built-In Automation PLC applications - Build in sequences
� Built-in Functions : embedded and validated� Autorecloser
� For feeder control
� up to 4 cycles , 1PH + 3PH, with Interlock checks
� parameters adaptable on the local LCD screen
� Synchronised CB Management (Synchro-Check)
� for Generator connection, or between 2 networks
> PACiS short EN – 20/05/08- Issue H34 34
� Customised criterias : Phase Angle, Frequency, magnitude
� parameters adaptable on the local LCD screen
� Automatic Voltage Regulation
� up to 4 transfos in // , manage up to 7 transfos
� Tap changer - Raise / Lower
� In association with others C264 interfaced on the station Bus -IEC61850
� Compounding – line drop compensation
� Circulating Current minimisation
� // Master/Follower
![Page 35: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/35.jpg)
MiCOM C264 – Customised Automation
� For various applications :
�Switching sequences,
�Busbar transfer,
�Load management, (slow)
�GIS pressure supervision
�Capacitor Bank management
� IEC61131-3 languages
PLC applications
> PACiS short EN – 20/05/08- Issue H35 35
� IEC61131-3 languages
� Structured Text (ST)
� SFC (Grafcet)
� Large capability to evaluate
�Analog values
�Digital values
� In complement of the fast PSL facilities (Programming Scheme Logic)
![Page 36: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/36.jpg)
PACiS Fast Load Shedding
� The Fast load shedding has it own dedicated network connected to the main PMS application
� Permanently recalculate the shedding priorities based on the real topology, power available and necessary loads
� Take in account the network constraints
� Transformer capabilities
�
OVERALLPROCESS CONTROL
> PACiS short EN – 20/05/08- Issue H36 36
� Generator spinning reserve
� In case of a sudden generator fault or grid weakness
� Trip directly the less prior elements
� Recalculate the total network availability
� Load sharing (active and reactive) between generators
� Islanding and reconnection (including synchronization)
Generation Load
![Page 37: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/37.jpg)
Ring Network Automatic reconfiguration
M
M
DELIVERY SUBSTATION
FEEDER 1 FEEDER 2
1 : THE FAULT IS SEEN :
2 : TRIPPING OF :
4 : RECLOSING OF THE INCOMING FEEDER
> PACiS short EN – 20/05/08- Issue H37 37
MM
M
MM
M
SUBSTATION A
SUBSTATION B
SUBSTATION D
SUBSTATION C
STANDARD OPEN POINT OF THE RING
FAULT
3 : ISOLATION OF THE FAULTY SECTION BY OPENING:
5 : RECLOSING OF THE OPEN POINT OF THE RING
![Page 38: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/38.jpg)
Introducing PACiS: Components
IEDsProtections, Computers, Measurement
> PACiS short EN – 20/05/08- Issue H38 38
SOFTWAREEngineering tools, SCADA
COMMUNICATIONSwitches, Gateways
![Page 39: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/39.jpg)
Ethernet Architecture : Redundant ring
Up to 4 TX links
MiCOM H152 PCI board located in one PC
Substation Level
PACiS GATEWAYSPACiS OI
> PACiS short EN – 20/05/08- Issue H39 39
Bay Type 4
Ethernet - up to 6 links
Bay Type 5
Ethernet - up to 4 links
MiCOM H352Din Case
![Page 40: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/40.jpg)
Ethernet Architecture : Large Dual physical star
Substation Level
PACiS GATEWAYS
MiCOM H600Optical star switch
PACiS OI
> PACiS short EN – 20/05/08- Issue H40 40
Bay level Type 1
Ethernetup to 6 links
C264C
MiCOM M
Ethernet up to 4 links
MiCOM H36xDin Case C264C
Bay level Type 2
Bay level Type 3
C264
RS485-upto 4 links
![Page 41: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/41.jpg)
Ethernet Architecture : Multi-rings
SCADA GATEWAYS
GATEWAYIEC/IEC
Ring A
PACiS OIPACiS OIPACiS OI
PACiS OIPACiS OI
> PACiS short EN – 20/05/08- Issue H41 41
H352 C264+ SWR
H352C264
+ SWR
Ring B Ring C
![Page 42: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/42.jpg)
Multi-ring architecture – Customer requirements
� DCS for complex substations (high number of bays / cells)
� High number of IEC 61850 equipments – BCU, Protection relays
� Segregation of voltage levels – signalization, command, maintenance
� Simple and compact system
> PACiS short EN – 20/05/08- Issue H42 42
� Simple and compact system
� Flexibility in outage & commissioning program
� Increased reliability
� Unique point of control
![Page 43: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/43.jpg)
Complex substations solutions
� Subsystem for each voltage level� Own Operator Interface Server and Workstations
� Own Database storage for events and measurements
� General view for single line diagram and system
� Detailed views for cells – status, commands, measurements
� Supervision of all protection relays in the subsystem
� Own dual optical fiber redundant ring
� Own Gateway (T101)
� System bus network traffic decrease
> PACiS short EN – 20/05/08- Issue H43 43
� Main (top) Subsystem� General single line diagram and system view for entire substation
� Unique point of command for entire substation
� Receive only necessary information from subsystems – positions, some measurements
� Can perform only a limited (predefined) number of commands – switching equipment commands
� Provides the main communication channel to upper level of SCADA (Dispatch center)
� Low network traffic on the main system bus
![Page 44: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/44.jpg)
…� Increased reliability and security
� Distributed DB – double storage if required� Multiple redundant optical rings� Redundant IEC/IEC Gateway� Lower network traffic on each ring� An eventual failure of a subsystem component or even an entire subsystem will not
affect the functionality of the other subsystems� Subsystem based user access rights. Same user can have different access right on
different subsystems� Dedicated IEC/IEC gateways – no rotating components
� Distribution of processing
> PACiS short EN – 20/05/08- Issue H44 44
� Distribution of processing� All logics run in the own subsystem – only intersystem inputs/outputs are crossing
through IEC/IEC Gateway� Detailed information available and stored only in the origin subsystem� Relay parameterization network for each subsystem� Smaller event database
� Easy installation and commissioning� Each subsystem can act like an stand-alone system and it can be commissioned
without interfering with other running subsystems� Any maintenance activity on one subsystem will not affect the other subsystems� An eventual configuration upgrade will affect only the destination subsystem� Easy to maintain smaller configuration database
![Page 45: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/45.jpg)
PACiS GTW : the SCADA interface
� Direct interface through serial and Ethernet connections� Integrated MiCOM H Ethernet switch boards
� Redundancy capabilities� Physical support (RS or Ethernet)� Global GTW
�Serial protocols� IEC 60870-5-101 (KEMA certified)� MODBUS
> PACiS short EN – 20/05/08- Issue H45 45
� MODBUS� DNP3� GI74� HNZ
� Ethernet protocols� IEC60870-5-104� OPC� IEC61850 (Reports only)� MODBUS over IP� DNP3 over IP
![Page 46: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/46.jpg)
Project examples
> PACiS short EN – 20/05/08- Issue H46 46
![Page 47: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/47.jpg)
Transmission Utility Application
Imprimante CDE N°1
Poste Opérateur N°1
Tranche Générale redondée
Passerelle redondée
raccordement au SCADA
FEDA
Poste Opérateur N°2(redondant)
Imprimante CDE N°2(redondée)
Switch N°1 Switch N°2
Poste Ingéniérie
Imprimante
220 kV susbtation for FEDA (ANDORRA)
> PACiS short EN – 20/05/08- Issue H47 47
Ligne RANSOL Ligne MARGINEDA 1 Ligne CENTRALELigne MARGINEDA 2 Ligne GRAU ROIG COUPLAGE Contrôle BARRE
IRIGB clock
Anneau Optique Ethernet redondant
IEC 61850
Imprimante graphique
![Page 48: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/48.jpg)
Distribution Utility Application
132/11 kV susbtations for DEWA (DUBAI – UAE)
> PACiS short EN – 20/05/08- Issue H48 48
![Page 49: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/49.jpg)
Oil & Gaz Application
Dolphin site with Fast Load shedding (< 80 ms)
TO ICSS TO ICSSITR0 / SS0
MS1
7 C264C 3 C264C
Ethernet TCP/IP 100Mb/s
Fast Load Sheeding
3 BM9100 PMS serverTO RTDB
OPC OPCIEC-60870-101 1 BM9200
To Bay Computers in
SS40GPS Clock
TeleProtection
To SS40
Hardwire DO
1 BM9200
+ 4 C264 + 5 BM9200
TO KAHRAMAA
OPC
SYSTEM MAINTENANCE AND ENGINEER’S ROOM
CENTRAL CONTROL ROOM
HUB HUB
> PACiS short EN – 20/05/08- Issue H49 49
SS40+ 4 C264C1 C264
SS2 SS21
SS11 SS14 SS24
SS30
SS1
SS12
3 C2642 BM9200 2 BM9200
2 BM9200 2 BM9200
2 BM9200
3 C264C2 BM9200
SS221 C264 4 C264
2 C264+ 5 C264C
4 C264
+ 6 C264C
Master FLS
2 BM9200 2 BM9200
FO From MS1
TeleProtection
Hardwire DO
+ 4 C264C
2 C264C+ 5 C264C
2 C264
3 C264SS3B
2 BM92003 C264C
+ 3 C264C
SS3A2 BM9200
+ 2 C264C
3 C264C
2 BM9200
FO From MS1
HUB HUB
+ 1 C264 + 3 C264C
![Page 50: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/50.jpg)
Railway Application
Metro substations for RATP (Metro of PARIS – FRANCE)
> PACiS short EN – 20/05/08- Issue H50 50
![Page 51: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/51.jpg)
Industrial Application
Georges Besse II for AREVA (Nuclear factory – FRANCE)
> PACiS short EN – 20/05/08- Issue H51 51
![Page 52: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/52.jpg)
Sensitive building Application
Tour Granite with Load Management (PARIS – FRANCE)
> PACiS short EN – 20/05/08- Issue H52 52
![Page 53: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/53.jpg)
Automation Romania portofolio
Distribution – Electrica
�110/20 kV Sibiu Aeroport substation with PACiS system� Operator interface server and client in substation� Remote client at Electrica Sibiu� Redundant optical fiber ring to connect system elements� GPS synchronization� Upper scada interface with Helios system via T101 protocol� 5 HV bays – « H » type substation
> PACiS short EN – 20/05/08- Issue H53 53
� 30 + 20 MV cells in substation + PA� LV internal services monitoring
� 110/20 kV Dumbrava Sibiu substation with PACiS system� Similar with Sibiu Aeroport� In final commissioning stage
![Page 54: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/54.jpg)
Automation Romania portofolio
Transport – Transelectrica
�« 11 Substations » pure automation project with PACiS system
� 220/110/20 kV substations : Targoviste, Cluj Floresti, Turnu Magurele, Stuparei, Isalnita, FAI, Baia Mare, Pestis, Arefu, Hasdat, Raureni� Project was started in 2005 and it’s still running until December 2010.
> PACiS short EN – 20/05/08- Issue H54 54
2010.
�220/110 kV Paroseni substation – turn-key project with Pacis system – finalized 2007
� 400 kV Moldova Axis – turn-key project with Pacis system –� Including Bacau Sud, Roman Nord, Suceava substations� finalized 2009
![Page 55: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/55.jpg)
Automation Romania portofolio
… Transport – Transelectrica
�400/220/110/20 kV Lacu Sarat – turn-key project with Pacis system – in progress
� 110kV Gutinas – turn-key project with Pacis system – in progress
� 400/110kV Tariverde – turn-key project with Pacis system –
> PACiS short EN – 20/05/08- Issue H55 55
� 400/110kV Tariverde – turn-key project with Pacis system –in progress
Railways – CFR
�Campina – Predeal traction substations – automation project with Pacis system – in progress
![Page 56: Sas-Sistem de control](https://reader033.vdocument.in/reader033/viewer/2022050709/563db7d4550346aa9a8e5e3e/html5/thumbnails/56.jpg)
www.areva-td.com