schneider a9f73202
DESCRIPTION
Schneider A9F73202 datasheetTRANSCRIPT
![Page 1: Schneider A9F73202](https://reader036.vdocument.in/reader036/viewer/2022081803/5695d0c51a28ab9b0293cb8e/html5/thumbnails/1.jpg)
The
info
rmat
ion
prov
ided
in th
is d
ocum
enta
tion
cont
ains
gen
eral
des
crip
tions
and
/or t
echn
ical
cha
ract
eris
tics
of th
e pe
rform
ance
of t
he p
rodu
cts
cont
aine
d he
rein
.Th
is d
ocum
enta
tion
is n
ot in
tend
ed a
s a
subs
titut
e fo
r and
is n
ot to
be
used
for d
eter
min
ing
suita
bilit
y or
relia
bilit
y of
thes
e pr
oduc
ts fo
r spe
cific
use
r app
licat
ions
.It
is th
e du
ty o
f any
suc
h us
er o
r int
egra
tor t
o pe
rform
the
appr
opria
te a
nd c
ompl
ete
risk
anal
ysis
, eva
luat
ion
and
test
ing
of th
e pr
oduc
ts w
ith re
spec
t to
the
rele
vant
spe
cific
app
licat
ion
or u
se th
ereo
f.N
eith
er S
chne
ider
Ele
ctric
Indu
strie
s SA
S no
r any
of i
ts a
ffilia
tes
or s
ubsi
diar
ies
shal
l be
resp
onsi
ble
or li
able
for m
isus
e of
the
info
rmat
ion
cont
aine
d he
rein
.
Sep 10, 20141
Product data sheetCharacteristics
A9F73202iC60N - miniature circuit breaker - 2P - 2A - Bcurve
MainCommercial Status CommercialisedCircuit breaker applica-tion
Distribution
Product or componenttype
Circuit breaker
Device short name IC60NPoles description 2PNumber of protectedpoles
2
[In] rated current 2 ANetwork type AC
DCTrip unit technology Thermal-magneticCurve code BBreaking capacity 10 kA Icu conforming to IEC 60947-2 - 72...125 V
DC10 kA Icu conforming to EN 60947-2 - 72...125 V DC50 kA Icu conforming to EN 60947-2 - 12...133 V AC50/60 Hz50 kA Icu conforming to IEC 60947-2 - 12...133 VAC 50/60 Hz25 kA Icu conforming to IEC 60947-2 - 440 V AC50/60 Hz25 kA Icu conforming to EN 60947-2 - 440 V AC50/60 Hz6000 A Icn conforming to IEC 60898-1 - 400 V AC50/60 Hz6000 A Icn conforming to EN 60898-1 - 400 V AC50/60 Hz50 kA Icu conforming to IEC 60947-2 - 380...415 VAC 50/60 Hz50 kA Icu conforming to IEC 60947-2 - 220...240 VAC 50/60 Hz50 kA Icu conforming to EN 60947-2 - 380...415 VAC 50/60 Hz50 kA Icu conforming to EN 60947-2 - 220...240 VAC 50/60 Hz
Utilisation category Category A conforming to IEC 60947-2Category A conforming to EN 60947-2
Suitability for isolation Yes conforming to IEC 60947-2Yes conforming to IEC 60898-1Yes conforming to EN 60947-2Yes conforming to EN 60898-1
![Page 2: Schneider A9F73202](https://reader036.vdocument.in/reader036/viewer/2022081803/5695d0c51a28ab9b0293cb8e/html5/thumbnails/2.jpg)
2
ComplementaryNetwork frequency 50/60 HzMagnetic tripping limit 4 x In +/- 20 %[Ics] rated service breaking capacity 10 kA 100 % x Icu conforming to EN 60947-2 - 72...125 V DC
10 kA 100 % x Icu conforming to IEC 60947-2 - 72...125 V DC6000 A 100 % x Icu conforming to IEC 60898-1 - 400 V AC 50/60 Hz6000 A 100 % x Icu conforming to EN 60898-1 - 400 V AC 50/60 Hz50 kA 100 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz50 kA 100 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz25 kA 100 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz50 kA 100 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz25 kA 100 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz50 kA 100 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz50 kA 100 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz50 kA 100 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
Limitation class 3 conforming to IEC 60898-13 conforming to EN 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2500 V AC 50/60 Hz conforming to EN 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-26 kV conforming to EN 60947-2
Contact position indicator YesControl type ToggleLocal signalling Trip indicatorMounting mode FixedMounting support DIN railComb busbar distribution block compatibility YES top or bottom9 mm pitches 4Height 85 mmWidth 36 mmDepth 78.5 mmProduct weight 0.25 kgColour WhiteMechanical durability 20000 cyclesElectrical durability 10000 cyclesConnections - terminals Single terminal, top or bottom flexible wire(s) 1...16 mm² max
Single terminal, top or bottom rigid wire(s) 1...25 mm² maxWire stripping length 14 mm top or bottomTightening torque 2 N.m top or bottomEarth-leakage protection Separate block
EnvironmentStandards EN 60898-1
EN 60947-2IEC 60898-1IEC 60947-2
IP degree of protection IP20 conforming to EN 60529IP20 conforming to IEC 60529
Pollution degree 3 conforming to IEC 60947-23 conforming to EN 60947-2
Overvoltage category IVTropicalisation 2 conforming to IEC 60068-1Relative humidity 95 % ( 55 °C )Operating altitude 0...2000 mAmbient air temperature for operation -35...70 °CAmbient air temperature for storage -40...85 °C
![Page 3: Schneider A9F73202](https://reader036.vdocument.in/reader036/viewer/2022081803/5695d0c51a28ab9b0293cb8e/html5/thumbnails/3.jpg)
3
Offer SustainabilitySustainable offer status Green Premium productRoHS Compliant - since 1001 - Schneider Electric declaration of conformityREACh Reference not containing SVHC above the thresholdProduct environmental profile Available Download Product EnvironmentalProduct end of life instructions Need no specific recycling operations