KaedraMultipole splitter blocks40 to 125 A stepped splitter blocks
Can be used in all types of enclosures, for distribution:b from the incoming switchboard unit to setsb from the incoming switchboard unit to devicesb from an incoming set to devices
Stepped splitter blocks are designed to distribute current in Pragma C12, D18 and F24 modular enclosures, in Prisma functional enclosures and in all types of enclosures.
installation on DIN or Multifi x rail; they can also be screwed onto a mounting plate or enclosure back
delivered with cover and insulating backinter-insulated barsdelivered with open screws (Posidrive recess + slot screws)incoming cable connection holes: staggered from bar to barpossibility of attaching Telemecanique markers on the bars’ insulator for circuit
identifi cation.
b
bbbbb
2-poleElectrical data
conform to standard EN 60947-7-1degree of pollution: 3nominal current: 40, 100 and 125 Apermissible rated peak current Îpk: 20 kÂrated short-time withstand current lcw: 3.5 kA rms/1 sinsulation voltage Ui: 500 V AC
bbbbbb
3-pole
E74
320
E74
203
40 to 125 A stepped splitter blocksType Number/diameter (mm) of holes per phase: Width in
mod. of 9 mm
Dimensions
Ø 4.4 Ø 5.5 Ø 7 Ø 8.5 W (mm) H (mm)2-pole
100 A 7 holes 3 3 1 7 62 40125 A 13 holes 5 5 2 1 12 107 404-pole
40 A 13 holes 11 2 10 89 812-pole 4-pole 100 A 7 holes 3 3 1 7 62 81
125 A 13 holes 5 5 2 1 12 107 81125 A 17 holes 7 7 2 1 15 134 81Min/max connection capacity per hole
Cable type Ø 4.4 Ø 5.5 Ø 7 Ø 8.5Rigid or semi-rigid 1.5.... 10 mm2 2.5.... 16 mm2 4.... 25 mm2 16.... 35 mm2
Flexible without end 1.5.... 6 mm2 4.... 10 mm2 6.... 16 mm2 25 mm2
Flexible with end 1.5.... 6 mm2 1.5.... 10 mm2 2.5.... 16 mm2 10.... 25 mm2
Nota : ends to be crimped: refer to the Telemecanique offers AZ5, DZ5, etc.
DB
1088
46
Neutral barTo increase the number of neutral terminals, an additional neutral bar can be attached to the 4-pole terminal blocks without increasing terminal block volume. This bar is clipped on without tools; cut-outs need to be made in the cover in order to connect the cables (only from the top).
E74
200
Catalogue numbers
100 to 125 A stepped 2-pole splitter block100 A (2 x 7 holes) 13506125 A (2 x 13 holes) 1350740 to 125 A stepped 4-pole splitter block
40 A (4 x 13 holes) 13508100 A (4 x 7 holes) 13510125 A (4 x 13 holes) 13512
DB
1088
47
125 A (4 x 17 holes) 13514Additional neutral bar
40 A (for splitter block 13508) 13516100 A (for splitter block 13510) 13515125 A (for splitter block 13512) 13517125 A (for splitter block 13514) 13518
L
H
50 L
H
50 L50
H
L50
H
Understand and choose
version: 2.2 93060E.indd 2
KaedraMultipole splitter blocksApplications
4-pole incoming switchboard unit
DB
1088
48
4-pole incoming set
DB
1088
49
2-pole incoming switchboard unit
DB
1088
50
N
55 88ØØ
N
55 88ØØ
N
55 88ØØ
N
55 88ØØ
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
O-OFF
Understand and choose
version: 2.2 93060E.indd 3
KaedraMultipole splitter blocksDimensions
40 to 125 A stepped splitter blocks2-pole
E74
204
E742
05
E74
206 A B
100 A (7 holes) 62 37125 A (13 holes) 107 82
4-pole
E74
207
E74
208
E74
209
A B40 A (13 holes) 89 63100 A (7 holes) 62 37125 A (13 holes) 107 82125 A (17 holes) 134 109
B
A
29
B
A
2953
44
50
4053
44
50
40
5050
B
A
47
B
A
47
93
43
50
81 93
43
50
81
5050
Understand and choose
version: 2.2 93060E.indd 4