sciam sales presentation rm 5.17.2012

17
Sciam Worldwide designs, patents and manufactures the DM3 Density Meter, a Non-Nuclear density sensor and mass flow system. The DM3 measures, transmits and displays wet density or sg and % dry solids of slurries.

Upload: czapata12

Post on 19-Jul-2015

311 views

Category:

Technology


0 download

TRANSCRIPT

  • Sciam Worldwide designs, patents and manufactures the DM3 Density Meter, a Non-Nuclear density sensor and mass flow system. The DM3 measures, transmits and displays wet density or sg and % dry solids of slurries.

  • Primary Industries

  • DM3 Measurement System

  • DM3 Density Meter

    Density Transducer Housing

    2-40

    Obstruction Free Chamber

    Low Natural Frequency To Absorb External Vibration

    Large Representative Sample

  • DM3 Transmitter

    Three Second Push Button Calibration & Revalidation

    Available With Class 1 Div 2 Explosion Proof Enclosure

    4-20 mA / RS232 / Ethernet Standard

    Uniquely Traceable to International Standards

    Digital I/O

  • Mass Flow Meters

    Calculates Wet or Dry Mass Flow Rate and Totals

    Typical Mass Flow System Accuracy (0.52 0.22) = 0.54% At Full Scale

    Various options of mass flow meters compatible with DM3 system.

  • Processor & Recorder

    Allows for Customized Calculations, Paperless Recording, Data Logging and Alarm Triggers

    4-20 mA Input From DM3 Transmitter and Magnetic Flow Meter

  • 110 Measurements Per Second

    45 Milliseconds Response Time

  • Repeatable to 0.1% full scale< 0.5% Full Scale Accuracy

  • DIRECT International Traceable Measurement of Mass Per Unit Volume

  • Tolerates 20 Tilt or Roll With < 0.2% Error

  • Pink Noise

    Average of Pink Noise

    The DM3 system Calculates the Average of the Average of Pink Noise

    at 110 Times Per Second

    True Density

    Unique Media & Industrial Pink Noise Compensation

  • Competitor ComparisonsSciam DM3Ultrasonic MicrowaveNuclear

    0.5% Full ScaleLarge45 millisecondsNoneAccountedExtremely SimpleExtremely SimpleMany

    1% Full ScaleSmall0.5 - 5 minutesNoneUnaccountedComplexComplexFew

    1% Full ScaleSmall0.5 - 5 minutesNoneUnaccountedComplexComplexFew

    1% Full ScaleSmall1-10 MinutesUnknownUnaccountedExtremely Complex

    Extremely Complex

    Many

    Average Accuracy Sample Size Response Time

    Safety Hazards Velocity Coefficient Error

    Installation Process Maintenence Applications

  • Savings Example - Mining

    Purchase PriceFlow tubeOn Site SupervisionMeter TransportComplianceSource Transport/Disposal

    $12,000$5,000$2,000$2,000$5,000$5,000

    $32,000IncludedIncluded

    $1,000$0$0

    Savings-$20,000

    $5,000$2,000$1,000$5,000$5,000

    InaccuracyCertification TrainingSpecialist StaffAdditional InsuranceReportingAdditional Error Cost

    $25,000$12,000$5,000$3,000$5,000

    $355,000

    $0$0$0$0$0$0

    $25,000$12,000$5,000$3,000$5,000

    $355,000

    Total Savings $33,000 $436,000 $403,000

    Per 18 Meter - Typical 1 Year

    Initia

    l Cos

    tsRu

    nning

    Cos

    ts

  • Savings Example - DredgingA comprehensive survey was done on dredgers operating on the Hudson River in USA (Reference: Baier, J.L., Douglas, W.S., Gimello, R.J., Lodge, J.). The various costs of dredging are comprehensively provided in this reference, a typical example is provided below.

    Average cost of dredgingAverage dredged volume per dayAverage dredged volume per 360 day yearCost per yearNuclear density meter typical overall accuracyCost of AmbiguitySciam Density Meter typical overall accuracyCost of Ambiguity

    $50 / yard per dredger8500 yard per dredger

    3.06 million yard per dredger$150 million per year per dredger

    2%$3.0 million per year

    0.285%$427,500

    Savings realized with Sciam DM3 $2,572,500

    Breakdown of Costs

    Per DredgerPer Year

  • How We Ensure AccuracyExternally Induced Plant Media Vibration: < 0.1%

    Temperature Coefficient Error 0.0014% per C over 30C: 0.04 / CTwo Plane Tilt: 20 Results In < 0.2%

    Load Cell & Transmitter Accuracy: < 0.1%

    Pressure Error Coefficient: Negligable

    Flow Tube Wear: < 0.1%

    Overall Error: < 0.285% Of Full Scale