LABORATORY TESTS iTEKT has conducted several laboratory tests to confirm the ITEKT Windshield product’s durability and resistance towards scratches, shattering, and UV light. In-sum, by comparing the average of millinewton (mN) of both samples required for the scratch at Region 1, there is an increase in resistance of the ITEKT treated sample by 25.61%. ASTM D523 - Specular Gloss ASTM D2244 - Calculation of Color Tolerances and Color Differences After 2,000 hours of UV exposure, the ITEKT treated sample: Did not show yellowing or color change since the measurements on the a* axis and b* axis did not change significantly. Its transparency got better since the L* axis measurements got closer to the white reference plate (93.0). The gloss measurements increased more than the untreated sample by 4% 71N pressure with a point of a diamond Xenon Arc emission lamp equipment used Scratch test - ASTM international (E2546/ISO 14577) Accelerated UV Light Aging test - ASTM international (D523- D2244) Detail results- Scratch Region 1 (mN) Untreated sample ITEKT treated sample 1 90.48 115.4 2 90.61 115.6 3 94.75 115.5 Average 91.95 115.5 Sample Initials values ASTM G155 L* a* b* Gloss 60º Untreated sample 82.9 -2.3 0.8 99.9 ITEKT treated sample 81.7 -2.3 0.7 96.5 White reference plate 93.0 -0.2 1.0 NA Sample 2,000 hours ASTM G155 L* a* b* Gloss % L* a* b* Gloss 60º Untreated sample 86.8 -2.4 1.1 104.4 3.9 -0.1 0.2 4 ITEKT treated sample 86.8 -2.4 1.0 104.9 4.9 -0.1 0.2 7

Upload: others

Post on 06-Feb-2021

14 views

Category:

Documents


0 download

TRANSCRIPT

  • LABORATORY TESTSiTEKT has conducted several laboratory tests to confirm the ITEKT Windshield product’s durability and resistance towards scratches, shattering, and UV light.

    In-sum, by comparing the average of millinewton (mN) of both samples required for the scratch at Region 1, there is an increase in resistance of the ITEKT treated sample by 25.61%.

    ASTM D523 - Specular GlossASTM D2244 - Calculation of Color Tolerances and Color Differences

    After 2,000 hours of UV exposure, the ITEKT treated sample:

    • Did not show yellowing or color change since the measurements on the a* axis and b* axis did not change significantly.

    • Its transparency got better since the L* axis measurements got closer to the white reference plate (93.0).

    • The gloss measurements increased more than the untreated sample by 4%

    71N pressure with a point of a diamond

    Xenon Arc emissionlamp equipment used

    Scratch test - ASTM international (E2546/ISO 14577)

    Accelerated UV Light Aging test - ASTM international (D523- D2244)

    Detail results- Scratch Region 1 (mN)

    Untreated sample ITEKT treated sample

    1 90.48 115.4

    2 90.61 115.6

    3 94.75 115.5

    Average 91.95 115.5

    SampleInitials values ASTM G155

    L* a* b* Gloss 60º

    Untreated sample 82.9 -2.3 0.8 99.9

    ITEKT treated sample 81.7 -2.3 0.7 96.5

    White reference plate 93.0 -0.2 1.0 NA

    Sample2,000 hours ASTM G155

    L* a* b*Gloss

    %L* a* b* Gloss 60ºUntreated sample 86.8 -2.4 1.1 104.4 3.9 -0.1 0.2 4

    ITEKT treated sample 86.8 -2.4 1.0 104.9 4.9 -0.1 0.2 7

  • LABORATORY TESTS

    The intent of the program is to compare the amount of energy required for a given impactor to break a typical windshield, in both untreated and treated versions.

    • Support the impact surface area with a 3 arms support

    • Impactor: steel ball, 1 ¼ diameter, 4.6 ounces

    LEGEND: Failure at the impact location No failure Failure at the support area (underneath the treated surface) Location: Location of the impact

    The energy levels represented by the height of the impactor at which no failure of the samples occurred, were as follows: 1. Bare windshield: Hb = 14 feet; 2. Treated windshield: Ht = 17 feet

    In terms of energy gain to break the windshield with the impactor, we can calculate the increase in resistance (Ri) as follows: Ri (%) = (Ht – Hb) / Hb x 100 = 21%

    Note: At the maximum tested height (20 feet), 6 samples out of 15 remained intact (unknown breaking point). © ITEKT

    Impact test - Laboratory certificationReport No. 1373

    Results of the impact test

    Impact test height

    Condition Sample Location 15 ft 16 ft 17 ft 18 ft 19 ft 20 ft

    Untreated sample

    1

    Left

    Center

    Right

    2

    Left

    Center

    Right

    ITEKT treated sample

    3

    Left

    Center

    Right

    4

    Left

    Center

    Right

    5

    Left

    Center N/a N/a N/a N/a N/a N/a

    Right

    6

    Left

    Center

    Right

    7

    Left

    Center

    Right

  • TESTS DE LABORATOIREiTEKT a effectué plusieurs tests en laboratoire pour confirmer la durabilité et la résistance du produit ITEKT Windshield contre les rayures, les éclats et la lumière UV.

    En somme, en comparant la moyenne de mesure de force en millinewton (mN) requis pour la rayure dans la région 1, il y a une augmentation de la résistance de l’échantillon traité par ITEKT de 25.61%.

    ASTM D523 - Brillant spéculaireASTM D2244 - Calcul des tolérances de couleur et des différences de couleur

    Après 2000 heures d’exposition aux UV, l’échantillon traité ITEKT :

    • N’a pas montré de jaunissement ni de changement de couleur car les mesures sur l’axe a * et l’axe b * n’ont pas changé de manière significative.

    • Sa transparence s’est améliorée puisque les mesures de l’axe L * se sont rapprochées de la plaque de référence blanche (93,0).

    • Les mesures de brillance ont augmenté plus de 4 % que l’échantillon non traité.

    Pression 71N avec une pointe de diamant

    Équipement de lampe utilisé d’émission d’arc au xénon

    Test de rayure - ASTM international (E2546/ISO 14577)

    Test de vieillissement accéléré à la lumière UV - ASTM international (D523- D2244)

    Résultats détaillés – Rayure région 1 (mN)

    Échantillon non traité Échantillon traité ITEKT

    1 90.48 115.4

    2 90.61 115.6

    3 94.75 115.5

    Moyenne 91.95 115.5

    ÉchantillonValeurs initiales ASTM G155

    L* a* b* Brillant 60º

    Échantillon non traité 82.9 -2.3 0.8 99.9

    Échantillon traité ITEKT 81.7 -2.3 0.7 96.5

    Plaque de référence blanche 93.0 -0.2 1.0 NA

    Échantillon2,000 heures ASTM G155

    L* a* b*Brillant

    %L* a* b* Gloss 60ºÉchantillon non traité 86.8 -2.4 1.1 104.4 3.9 -0.1 0.2 4

    Échantillon traité ITEKT 86.8 -2.4 1.0 104.9 4.9 -0.1 0.2 7

  • TESTS DE LABORATOIRE

    Le but du programme est de comparer la quantité d’énergie requise pour un impacteur donné pour fracasser des pares-brises non traitées et traitées.

    • Support à 3 points : Supporte la surface d’impact

    • Impacteur : bille d’acier, 1 ¼ de diamètre, 4,6 onces

    LÉGENDE : Défaillance au point d’impact Aucune défaillance Défaillance au niveau de la zone d’appui (sous la surface traitée) Emplacement : emplacement de l’impact

    Les niveaux d’énergie représentés par la hauteur de l’impacteur à laquelle aucune défaillance des échantillons ne s’est produite étaient les suivants :1. Pare-brise non traité : Hn = 14 pied; 2. Pare-brise traité : Ht = 17 pied

    En termes de gain d’énergie pour fracasser le pare-brise avec l’impacteur, on peut calculer l’augmentation de résistance (Ri) comme suit: Ri (%) = (Ht - Hn) / Hn x 100 = 21%

    Remarque : À la hauteur maximale testée (20 pieds), 6 échantillons traités sur 15 sont restés intacts (point de rupture inconnu). © ITEKT

    Test d’impact - Certification de laboratoireRapport n° 1373

    Résultats du test d’impact

    Hauteur du test d’impact

    Condition Échantillon Emplacement 15 pi 16 pi 17 pi 18 pi 19 pi 20 pi

    Échantillon non traité

    1

    Gauche

    Centre

    Droite

    2

    Gauche

    Centre

    Droite

    Échantillon traité ITEKT

    3

    Gauche

    Centre

    Droite

    4

    Gauche

    Centre

    Droite

    5

    Gauche

    Centre N/a N/a N/a N/a N/a N/a

    Droite

    6

    Gauche

    Centre

    Droite

    7

    Gauche

    Centre

    Droite