sdc electric strikes, magnetic locks, electric door …...1512 electromagnetic door lock psb560 rex...
TRANSCRIPT
Convenience Store SafetyAfter-Hour Store Front Security Solution
1512 Electromagnetic Door Lock PSB560 REX Pressure Sense Bar
1511 Electromagnetic Door Lock 801N Key Switch
UB11 or UB12 Universal Header Brackets 631RF 1.5 Amp Power Supply
EA100 Multi-Mode Exit Annunciator Concealed Switch 15-2 WRC Transmitter & Receiver
• Employee Lockdown Protection• Customer Safety • Prevent Robbery• Reduce Liability
• Double Housing- Pair Doors• Holding Force- 1650 lbs.• UL Listed, 12/24 VDC• Clear Anodized Aluminum• Optional Monitoring
• Releasing Device• Slim Profile• Includes Transfer Loop• UL Listed
• Single Door• Holding Force- 1650 lbs.• UL Listed, 12/24 VDC• Clear Anodized Aluminum• Optional Monitoring
• Vandal Resistance• Aluminum Narrow Frame
Mount• SPDT, ON/OFF• Key Cylinder-Optional
• Mounting Header Bracket• Predrilled and Tapped• Clear Anodized Aluminum• Install Labor Savings• For 4” or 4.5” Aluminum Header
• 12/24 VDC, 1.5 Amp• Regulated and Filtered• Emergency Release Input• UL Listed• Batteries Optional
• Visual Multicolor Signal• Wall, Ceiling, Frame Mount• 12/24 VDC, Voltage
• Counter Mount• SPDT, Momentary
• Wireless Fob Transmitter• Two Buttons• Two Channel Receiver
LOCKING SOLUTION OPTIONS ACCESS CONTROL COMPONENTS
1a 3
1b 4
1c 5
2 6a
WRC-R2WRC-2B
The lock behind your system(800) 413-8783 ■ WWW.SDCSECURITY.COM
PROJECT NAME:
DIST.: DWG. NO.:DRAWN BY: DATE:LOCATION.: CONTACT:
SO NO.: REVTITLE:-801 Avenida Acaso
Camarillo, CA 93012t 805.494.0622 ~ f 805.494.8861www.sdcsecurity.com
Convenience Store Safety
--
After-Hour Convenience Store Security Solution Wiring
- [email protected] --10/2016 --
-
© 2016 Security Door Controls Printed in U.S.A
NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR ITS CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN WHICH THE EQUIPMENT IS INSTALLED AND OPERATED. ALL WIRING MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES FOR CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.
C NO C NO - NO C NC - NO C NC
- +
TRIG A TRIG B RELAY A RELAY B
w
DA
w
DB
12
34
J1
UR-1
Switch No:
off offPosition SW1 SW2
off
SW3
off
SW4
Dip Switches Set For “CR Mode”
OFF
631RF
BatteryChargerIndicator Fuse
AC PowerLED
PrimaryFuse 250V1.5Amp
BatteryInput
12V
SHORT
OPEN
24V
VOLTAGE SELECT
System StatusLED
NOTE:SET TO 24VDC.
Power must be turned off before changing voltage jumper
G W B
TO 120VAC PRIMARYVOLTAGE CONNECTION
(Remove factory installed jumper only when fire alarm interface is used)
+-
DC Voltage Output
Terminals+ - C
+ -RB12V4
5 AMP HOUR BATTERY
+ -RB12V4
5 AMP HOUR BATTERY
SDC P/N: RB12V4-2(Optional Battery Backup)
Key Switch -Alternate-Action
System Activation (ON/OFF) COM
NO
WHT
YEL
SDC P/N: 801NAL
NC
(Mortise cylinder not included)
ORG
Left Door
C-GRNN/C-BLU
RED(+)
SDC P/N: 631RFXUR-1
1.5 Amp Power Supply w/ Enclosure & Universal Relay Module
SDC P/N: PSB560V
Pressure Sense Bar #1
Right Door
C-GRN
N/C-BLU
SDC P/N: PSB560VPressure Sense Bar #2
(for 1512 Emlock)
PWR
SDC P/N: 432KLDURLatching Push Button
w/ Key Reset
jumper
COM
N/C N/O
COM
N/C
N/O
SDC P/N: 15-2
ConcealedDesk Switch
Momentary Door Release
(HardwiredOption)
BLKRED
GRN
BLU
ORG
WHT
Door StatusLED Annunciator
(above door)GRN = Unlocked
RED = Locked
SDC P/N: EA100
BLK(-)
RED(+)BLK(-)
PowerTransfer
PowerTransfer
Lockdown(w/ Key Switch
Override)
(N/C)(N/C)
(N/O)(N/O)
(N/O)(N/O)
(N/C)(N/C)
DPST
SDC P/N: 1511V (Single)OR 1512V (Double)
LeftDoor
Right Door
EMLock®
Note: Single door application will only have (1) PSB and (1) EMLock terminal board.
System Operation:1. Maglocks shall be manually unlocked during normal business hours by activating the ON/OFF key switch.
2. After hours, maglocks may be momentarily de-energized by using the concealed desk switch or wireless push button.
3. Pressure sense exit bars on each door will allow free egress at all times.
4. An LED annunciator located above the door will show the energized/de-energized status of the maglocks.
5. Activation of the Lockdown Button will instantaneously energize the maglocks. The key switch, desk switch & wireless release will be bypassed, and doors will remain locked until the lockdown button is reset by key.
Prog. Status LED
Wiring Pigtail Connector
LearningButton
RED (+24VDC)BLK (GND)
GRN (Relay 1 - NC)ORG (Relay 1 – Com)YEL (Relay 1 – N/O)
Relay 1Relay 2
C B A C B A + (-)
M
L
3S
PwrIn
SDC P/N: WRC-R2
Momentary Door Release
(WirelessOption)
RF Receiver