search markings
TRANSCRIPT
-
8/9/2019 Search Markings
1/24
Technical Search Considerations
Search Markings
-
8/9/2019 Search Markings
2/24
Case 1 If some numbers known, fill in
600 700 Block Alpha Street 800
701
706
702 704 708 710
703 705 707 709
-
8/9/2019 Search Markings
3/24
Case 2 No numbers known, use low nos
800 900 Block Alpha Street 1000
900 902 904 906 908
901 903 905 907 909
-
8/9/2019 Search Markings
4/24
If more than one side, use more letters
700 Block Alpha Street
SIDE C
SIDE A
SIDE
D
SIDE
B
-
8/9/2019 Search Markings
5/24
Also use and MARKMARK column grid
700 Block Alpha Street
E
Quad. B
Quad. A
Quad. C
Quad. D
-
8/9/2019 Search Markings
6/24
Use existing column grid IfKnown
700 Block Alpha Street
1
2
3
4
A GB C D E F
-
8/9/2019 Search Markings
7/24
Ground floor is 1
Second is 2 Third is 3
First floor below grade is B-1
Second is B-2
-
8/9/2019 Search Markings
8/24
Structure and HAZMAT Specialist make a 2' x 2'box on building adjacent to accessible entry point
Done after HazardsAssessment and filling outStructure / Hazards Evaluation
Box is spray painted using International Orange(in TFCache)
-
8/9/2019 Search Markings
9/24
Structure relatively safe for
S&R ops little chance offurther collapse
Victims could be trapped bycontents
Victims could be unconscious
-
8/9/2019 Search Markings
10/24
Structure significantly damaged
Some areas may be relativelysafe, but others may needshoring, bracing, removal, and/ormonitoring of hazards
Building could be completelypancaked
-
8/9/2019 Search Markings
11/24
Structure NOT SAFE for Rescue Ops
and may be subject to suddencollapse
Search Remote Search Ops mayproceed at significant risk
IfRescue Ops are undertaken, create
safe haven areas and rapidevacuation routes (with structure
monitoring)
-
8/9/2019 Search Markings
12/24
Arrow next to Marking Box
indicates the direction of safestentry to structure
-
8/9/2019 Search Markings
13/24
HM indicates hazardous
material condition in oradjacent to structure
S&ROps normally will not beallowed until condition is better
defined or eliminated
HM
-
8/9/2019 Search Markings
14/24
15JUN92
HM NATURALGASOR-1
No entry until gas turned off
When its mitigated, line out the HM mark and
record new date and TF
-
8/9/2019 Search Markings
15/24
Must be easy to make, read, and understand
Large distinct marking outside main entrance
Orange spray paint easily seen on mostbackgrounds
Line marking or downward spray cans apply
best marks
-
8/9/2019 Search Markings
16/24
Markings completed in two steps
L
arge single slash near main entrance at start ofsearch
Second large single slash opposite direction aftersearch of entire structure forming an X
-
8/9/2019 Search Markings
17/24
Left Quadrant search team identifier, date andtime first entered structure
Top Quadrant date and time team left structure Right Quadrant any significant hazards inside
structure Bottom Quadrant number of live or dead still
inside structure
-
8/9/2019 Search Markings
18/24
Search Team Identifier CA-2
Date of Entry 2-24
Time of Entry 1150
When you Enter
-
8/9/2019 Search Markings
19/24
When you Exit INCOMPLETE SEARCH/NO ENTRY
CA-2
2-24
1150
2-241520
2-L
3-D
RATS
F 1- 4
Date and time
Search Team
left structure
Hazards
Total victims
still inside
the structure
Indicates floors or quadrants completed.
F = Floors Q = Quads
-
8/9/2019 Search Markings
20/24
When you Exit COMPLETE SEARCH
CA-2
2-24
1150
2-241520
2-L3-D
RATS
F 1- 4
Date and time
Search Team
left structure
Hazards
Total victims
still inside
the structure
-
8/9/2019 Search Markings
21/24
When you ENTER When you EXIT
Identify any victims
Identify any
hazards
-
8/9/2019 Search Markings
22/24
-
8/9/2019 Search Markings
23/24
(UseAir horn or loud whistle)
Cease operations, all quiet 1 long blast = STOP
Evacuate the area
3 short blasts = OU
T, OU
T, OU
T Resume operations
1 long & 1 short blast = OK
-
8/9/2019 Search Markings
24/24
Operations area should be secure
OPERATIONALWORK AREA
COLLAPSE /HAZARD ZONE
FIRE LINE DO NOT CROSS FIRE LINE DO NOT CROSS