14
Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 © 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20 PHOTOGRAPHS PHOTOGRAPH #1 BUILDING 23 SECTION E Contractor has cleaned construction debris and raked grounds. PHOTOGRAPH #2 BUILDING 23 SECTION C Contactor in process of removing construction debris and raking grounds.

Upload: others

Post on 18-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPHS

PHOTOGRAPH #1BUILDING 23

SECTION E

Contractor has cleaned construction debris and raked grounds.

PHOTOGRAPH #2 BUILDING 23 SECTION C

Contactor in process of removing construction debris and raking grounds.

Page 2: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 2

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #3BUILDING 23

UNIT # 2317

Gap at head of both windows in guest bedroom exceed allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.

PHOTOGRAPH #4 BUILDING 23 UNIT #2317

Gap at jambs of windows spacing is at maximum spacing tolerance for manufacturer's NOAs for integral fin anchorage.

Page 3: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 3

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #5BUILDING 23

UNIT #2318

Gap at head of window within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.

PHOTOGRAPH #6 BUILDING 23 UNIT #2318

Gap at jamb of window within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.

Page 4: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 4

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #7 BUILDING 23 UNIT #2325

Gap at head of window within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.

PHOTOGRAPH #8 BUILDING 23 UNIT #2325

Gap at jamb of window within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.

Page 5: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 5

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #9 BUILDING 23 UNIT #2325

Dupont flashing overlaps as per manufacturer's requirements at jambs to sill transition.

PHOTOGRAPH #10 BUILDING 21 SECTION H

Stucco sub-contractor bas applied brown coat of stucco and begun finish coat of stucco.

Page 6: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 6

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #11 BUILDING 21

SECTION G

Stucco sub-contractor bas applied scratch coat of stucco.

PHOTOGRAPH #12 BUILDING 21 SECTION G

Sub-contractor has applied brown coat of stucco and begun finish coat of stucco.

Page 7: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 7

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #13 BUILDING 21 SECTION F

Metal lathing and stucco accessories have been installed and inspected for fastening and overlapping requirements.

PHOTOGRAPH #14 BUILDING 21 SECTION F Metal lathing and stucco accessories have been installed and inspected for fastening and overlapping requirements.

Page 8: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 8

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #15 BUILDING 21 SECTION F

Metal lathing and stucco accessories have been installed and inspected for fastening and overlapping requirements.

PHOTOGRAPH #16 BUILDING 21 SECTION F

New vented soffit has been installed and inspected.

Page 9: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 9

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #17 BUILDING 21 UNIT #2116

Gap at head of one window in living room exceeds allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.

PHOTOGRAPH #18 BUILDING 21 UNIT #2116

Gap at jambs of windows within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.

Page 10: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 10

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #19 BUILDING 21 UNIT # 2128

Gap at windows within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.

PHOTOGRAPH #20 BUILDING 21 UNIT # 2111

Gap at windows within allowable spacing for compliance with manufacturer's NOA for integral fin anchorage.

Page 11: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 11

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #21 BUILDING 21 SECTION E

Contractor removing old paints and rust at breezeway railings with electric grinders.

PHOTOGRAPH #22 BUILDING 21 SECTION D

Contractor performing framing and gable end repairs.

Page 12: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 12

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #23 BUILDING 21 SECTION B

Damaged wall framing inspected and marked for repairs.

PHOTOGRAPH #24 BUILDING 21 SECTION A

Damaged breezeway framing inspected and marked for repairs.

Page 13: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 13

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #25 BUILDING 21 SECTION A

Damaged breezeway framing inspected and marked for repairs.

PHOTOGRAPH #26 BUILDING 21 SECTION A

Damaged balcony deck board have been identified and marked for repairs.

Page 14: SECTION C construction debris and raking grounds. Contactor in … · Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 1 ©

Vintage Grand Condo Assn, Inc Project No: R1503-302F 4017 Crocker’s Lake Blvd., Sarasota FL Photo Sheet 14

© 2020 Delta Engineering & Inspection, Inc. Week of 6/29/20

PHOTOGRAPH #27 BUILDING 21 SECTION A

Framing and balcony damage has been identified and marked for repairs.