section e: pedestrian wayfinding - rutgers university · 2020-01-23 · rutgers university...
TRANSCRIPT
SECTION E:
PEDESTRIANWAYFINDINGPDR10 SERIES PEDESTRIAN DIRECTIONAL
PDR20 SERIES PEDESTRIAN DIRECTIONAL
WITH ORIENTATION MAP
ORT10 SERIES ORIENTATION MAP
Some pedestrian wayfinding signs were implemented prior
to the completion of this Universitywide Standard. These
signs have been documented and are represented in this
section. There are some pedestrian wayfinding signs that are
unique to the Health Science campus and can be found in
Section J of this manual.
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.22E.2
This Page Intentionally Left Blank
SECTION E:
PDR10 SERIES
SUB-SECTION
2E.4 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PDR10 Series – Pedestrian Directional
PDR11Config. 1
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
PDR12
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
PDR11Config. 2
MessageMessage
MessageMessage
MessageMessage
MessageMessageMessage
PDR13Config. 1
Lot XXAddress
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
PDR13Config. 2
Lot XXAddress
MessageMessage
MessageMessage
MessageMessage
MessageMessageMessage
PDR14Config. 2
Lot XXAddress
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
PDR15Config. 1
Lot XXAddress
Lot XXAddress
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
PDR15Config. 2
Lot XXAddress
Lot XXAddress
MessageMessage
MessageMessage
MessageMessage
MessageMessageMessage
PDR10 Series Overview
Recommended sign type
configurations shown.
Additional module
configurations must be
approved by Rutgers
University Environmental
Graphics Coordinator &
or Department of Facilities,
Planning and Development
Below are the following steps for
selecting the correct pedestrian
directional for your needs.
A. Determine the number of
messages and parking messages
you require.
B. Determine message lengths
and character (letter) counts for
each message. Are your
messages 1, 2 or 3 lines long?
C. Select from the typical module
heights based on previous steps.
See graphic layout pages for
sample typographic layouts.
D. Review graphic dont’s to
ensure proper selection.
Sign Selection Process
Questions? Please contact xxxxx
?
1 MSG 2 MSG 3 MSG 4 MSG 5 MSG 6 MSG4 MSG
+ 1 PARK
4 MSG
+ 2 PARK
3 MSG
+ 3 PARK
3 MSG
+ 1 PARK
3 MSG
+ 2 PARK
3 ARROW N/A N/A N/A N/A N/A N/A N/A
PDR125 ARROW N/A N/A N/A N/AN/AN/AN/AN/A
4 ARROW N/A N/A N/AN/A N/AN/AN/AN/A N/A
PDR126 ARROW N/A N/A N/A N/A N/A N/A N/A N/A
2 ARROW N/A N/A N/A N/A N/A N/A
N/A N/A N/A
N/A N/A N/A N/A
1 ARROW N/APDR11
Config. 2
PDR11Config. 2
N/A N/A N/A N/A N/A N/A N/A N/A N/A
PDR10 SERIES:
PDR11Config. 2
PDR11Config. 2
PDR11Config. 1
PDR13Config. 1
PDR15Config. 2
PDR15Config. 1
PDR15Config. 2
PDR13Config. 2
PDR14Config. 2
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessageMessage
Configuration 1 Configuration 2
27"
a
C
D
HB
E
G
F
I
J
Full length filler panels are used for single sided signs only. (not shown)
Stop panel below grade line. (not shown)
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT PEDESTRIAN DIRECTIONAL
PDR11
PART COUNTS
POST CAP POST CAP
SIGN POST SIGN POST
PNL.1 PNL.1
FP_1 FP_1
PNL.2 PNL.3
PNL.4
FP_2
FP_2
FP_3
FP_3
FP_S
FP_S
2 2
2 2
1 1
4 4
1 1
1
2
2
2
2
4
4
2 2
2 2
2 2
8 8
2 2
2
4
4
0
0
4
4
CONFIGURATION 1: CONFIGURATION 2:
SINGLE SIDED
SINGLE SIDED
DOUBLE SIDED
DOUBLE SIDED
A A
B B
C C
D D
E E
G H
H
I
I
J
J
* *
* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.
For specification and ordering purposes, contact EMS Delaware;
231 Executive Drive Suite 11
Newark, DE 19702 USA
Toll Free: 800-863-1496
Local Phone: 302-391-1370
Fax: 302-391-1371
Website: www.EasternMetal.com
Email: [email protected]
CONFIGURATIONS
Helpful Hints
• Keep in mind the intuitive
path of the user when locat-
ing and specifying exterior
directional signs.
• Use only standard and
approved nomenclature
and abbreviations.
• Refer to all appropriate state
and local codes, as needed,
for sign compliance, includ-
ing, but not limited to zon-
ing, ADAAG, MUTCD, etc.
• Sign fabricator to provide
all relevant engineering
calculations and provide all
methods and materials
of construction in
shop drawings.
Guidelines
• Provide pedestrians with
sequential guidance
throughout the campus with
strategic placement and
programmed messaging.
• Reinforce the brand equity
in the built environment with
brand color on the header.
• Use as a single-sided or
double-sided sign. Message
standards apply to both sides
of sign. It is acceptable to
use a different configuration
on each side.
• Locate signs at key decision
points and at locations
of optimal line of sight
from public buildings and
campus core.
• Arrow order should be as
follows: Up (straight),
Left, Right.
• Do not rearrange panel order.
PARTS
2E.5
Questions? Please contact xxxxx
?
SECTION E: PEDESTRIAN WAYFINDING
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessageMessage
1/8"
4"1"
1'-8
15/
16"
1"8"
2'-3
"2"
min
.
5'-2
"
2'-6
"
eq.
6"eq
.
1'-4
"
3/4"2'-0"- graphic panel
3/4"
3 1/4" 1'-7" 3 1/4"
eq. 2'-1 1/2" eq.
2'-9 1/2"
grade line
A
CD
D
BH
CEF
CEF
G
G
E
G
IBA
J
F
I
PDR11: Configuration 1 3/4” = 1’-0”
Plan Elevation-Single side Sign(double side panels shown dashed)
DR33: Configuration 1, 21/2” = 1’-0”
PDR11: Configuration 23/4” = 1’-0”
Back Elevation- Single side Sign(panel configurationvaries, 1 shown)
KL
KL
2E.6
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.2 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
F PNL.3 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P3.
*Use one panel only for single sided sign.
PDR11PEDESTRIAN DIRECTIONAL
2E.7
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
This Page Intentionally Left Blank
G PNL.5 Painted aluminum panel
w/ applied vinyl graphics.
Custom extruded panel
attachment to be mounted
to back of panel w/ hi-bond
adhesive. Paint all sides: P3.
*Use one panel only for single sided sign.
H FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
I FP_3 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1. *Use only for single sided signs.
J FP_S 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
K Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
L Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
SECTION E: PEDESTRIAN WAYFINDING
PEDESTRIAN DIRECTIONAL
PDR11
becomessign panel
Component Parts /Assembly
Finished Sign
C
A
O
D
B
EFG
H
I
P
M
N
2E.8
DETAIL
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post
cap, mechanically fastened
w/ tamper-resistant, span-
ner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.2 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
F PNL.3 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P3.
*Use one panel only for single sided sign.
PDR11PEDESTRIAN DIRECTIONAL
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
3'-2" panel length
3/4" 1 3/4" 3/4"
3 1/4"
1/8"typ.
2"
1/8"
typ
.
7/8"
4 1/
4"7/
8"
6"
1/8"7/8"
1/8"
1 1/8"
1/4"
pan
el e
xtru
sio
n v
arie
s-se
e el
evat
ion
s fo
r h
eig
ht
dim
ensi
on
s
1/4"
pan
el h
eig
ht
vari
es-
see
elev
atio
ns
for
hei
gh
t d
imen
sio
ns
4" a
bov
e fi
nis
hed
gra
de
Partial Horizontal Section 6” = 1’-0”
Vertical Section: Concrete Footerno scale
Plan Elevation at Sidewalkno scale
Panel Detail no scale
EFG
FE
G
G
B
P
O
O
P
grade line grade line
B
L
M
N
H
K
L
M
at concrete sidewalk condition
Vertical Section: Concrete Footerno scale
at earth / grass condition
2E.9
DETAIL
Specifications
SECTION E: PEDESTRIAN WAYFINDING
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
G PNL.4 Painted aluminum panel
w/ applied vinyl graphics.
Custom extruded panel
attachment to be mounted
to back of panel w/ hi-bond
adhesive. Paint all sides: P2.
*Use one panel only for single sided sign.
H FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
I FP_7 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1. *Use only for single sided signs.
K Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
L Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
M Expansion Joint To accommodate concrete
expansion and contraction.
N Sand Compacted sand for con-
densation drainage per
engineering requirements.
O Attachment Bracket Rutgers owned custom ex-
truded bracket cut to match
height of aluminum plate.
Permanently mount to back
of plate.
*See post extrusion spec. information on Parts sheet.
P Sign Panel Plate 1/8” Thk. aluminum plate cut
to dimensions shown
in elevations.
PEDESTRIAN DIRECTIONAL
PDR11
Lot XXAddress
Up to TwoLine Message
Up to TwoLine Message
Up to Three LineMessage
alig
nal
ign
Up to Two Line Message
Up to Two Line Message
Up to Two Line Message
Up toThree LineMessage
aB
aB
B
d
C
a
PNL.3 (max. message)1” = 1’-0”
PNL.2 (max. message)1” = 1’-0”
PNL.3 (max. message)1” = 1’-0”
CL
C L -
typ
.C L
CL
C L -
typ
.
CL CL
3" 2 1/4" 1'-4 1/4"- max. copy length
3"2"
-ty
p.
4"-
typ
.
1 1/
4"
3" 2 1/4" 1'-4 1/4"- max. copy length
3"2"
-ty
p.
4"-
typ
.
1 1/
4"1
1/4"
1 1/
4"
3" 2 5/8" 1 1/2"1'-2 1/2"-
max. copy length
3 3/
16"
2"
2E.10
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.10
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
GRAPHIC LAYOUTS
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Copy 1 1/4” X-cap Height.
Type: T2. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
B Arrow_Symbol.eps 1 3/4” Height.
Artwork provided by client.
Apply to front surface
of panel.
Applied Vinyl: V2. Rotate arrow around object
center-point.
C Copy 1 1/4” X-cap Height.
Type: T1. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
D Parking_Symbol.eps 1 1/2” Height.
Artwork provided by client.
Apply to front surface
of panel.
Applied Vinyl: V2, V1.
PDR11PEDESTRIAN DIRECTIONAL
Visitors Must UseMain Entrance
University BehavioralHealth Care
No more than SIX messagesper sign.
ONLY includeparking messageson parking panels
No more than THREE lines per message.
Panels must MATCH the 27’’baseline.
Do NOT rearrangepanels.
PNL.2/PNL.3- Variation1” = 1’-0”
E2 3/
8"1
5/8"
1"
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
Message
Message
Message
Message
Message
Message
Message
MessageMessageMessage
MessageMessage
MessageMessage
Message
MessageMessage
Lot XXAddress
Lot XXAddress
Lot XXAddress
Lot XXAddress
2E.11
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
2E.11
GRAPHIC DONT’S
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
E Secondary Copy 1” X-cap Height.
Type: T1. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
GRAPHIC LAYOUTS
SECTION E: PEDESTRIAN WAYFINDING
PEDESTRIAN DIRECTIONAL
PDR11
2E.12 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
This Page Intentionally Left Blank
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
Configuration 1
27"’
a
C
D
FB
E
G
H
Full length filler panels are used for single sided signs only. (not shown)
Stop panel below grade line. (not shown)
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR12
PART COUNTS
POST CAP
SIGN POST
PNL.1
FP_1
PNL.5
FP_2
FP_7
FP_S
2
2
1
2
1
2
2
4
2
2
2
4
2
4
0
4
CONFIGURATION 1:
SINGLE SIDED
DOUBLE SIDED
A
B
C
D
E
F
G
H
*
* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.
For specification and ordering purposes, contact EMS Delaware;
231 Executive Drive Suite 11
Newark, DE 19702 USA
Toll Free: 800-863-1496
Local Phone: 302-391-1370
Fax: 302-391-1371
Website: www.EasternMetal.com
Email: [email protected]
CONFIGURATIONS
PEDESTRIAN DIRECTIONAL
Helpful Hints
• Keep in mind the intuitive
path of the user when locat-
ing and specifying exterior
directional signs.
• Use only standard and
approved nomenclature
and abbreviations.
• Refer to all appropriate state
and local codes, as needed,
for sign compliance, includ-
ing, but not limited to zon-
ing, ADAAG, MUTCD, etc.
• Sign fabricator to provide
all relevant engineering
calculations and provide all
methods and materials
of construction in
shop drawings.
Guidelines
• Provide pedestrians with
sequential guidance
throughout the campus with
strategic placement and
programmed messaging.
• Reinforce the brand equity
in the built environment with
brand color on the header.
• Use as a single-sided or
double-sided sign. Message
standards apply to both sides
of sign. It is acceptable to
use a different configuration
on each side.
• Locate signs at key decision
points and at locations
of optimal line of sight
from public buildings and
campus core.
• Arrow order should be as
follows: Up (straight),
Left, Right.
• Do not rearrange panel order.
PARTS
2E.13
Questions? Please contact xxxxx
?
SECTION E: PEDESTRIAN WAYFINDING
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
1/8"
4"1"
2'-3
"2"
min
.
5'-2
"
eq.
6"eq
.
1'-4
"
3/4"2'-0"- graphic panel
3/4"
3 1/4" 1'-7" 3 1/4"
eq. 2'-1 1/2" eq.
2'-9 1/2"
3'-2
"
grade line
A
CD
BF
CEF
CEF
G
G
E
gBA
g
PDR12 3/4” = 1’-0”
Plan Elevation-Single side Sign(double side panels shown dashed)
DR33: Configuration 1, 21/2” = 1’-0”
Back Elevation- Single side Sign
ij
KL
H
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
2E.14
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.4 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
F FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
G FP_7 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
J FP_S 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
PDR12PEDESTRIAN DIRECTIONAL
2E.15
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
This Page Intentionally Left Blank
K Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and
appropriate wind-loads for
individual structure. Footer
to be below grade and
landscaping, by others,
where necessary.
L Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
SECTION E: PEDESTRIAN WAYFINDING
PEDESTRIAN DIRECTIONAL
PDR12
becomessign panel
Component Parts /Assembly
Finished Sign
C
A
M
D
B
E
F
G
N
M
N
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
2E.16
DETAIL
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post
cap, mechanically fastened
w/ tamper-resistant, span-
ner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.4 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
F FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
G FP_7 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1. *Use only for single sided signs.
PDR12PEDESTRIAN DIRECTIONAL
3'-2" panel length
3/4" 1 3/4" 3/4"
3 1/4"
1/8"typ.
2"
1/8"
typ
.
7/8"
4 1/
4"7/
8"
6"
1/8"7/8"
1/8"
1 1/8"
1/4"
pan
el e
xtru
sio
n v
arie
s-se
e el
evat
ion
s fo
r h
eig
ht
dim
ensi
on
s
1/4"
pan
el h
eig
ht
vari
es-
see
elev
atio
ns
for
hei
gh
t d
imen
sio
ns
4" a
bov
e fi
nis
hed
gra
de
Partial Horizontal Section 6” = 1’-0”
Vertical Section: Concrete Footerno scale
Plan Elevation at Sidewalkno scale
Panel Detail no scale
E
E
G
B
N
M
M
N
grade line grade line
B
J
K
L
I
I
J
K
at concrete sidewalk condition
Vertical Section: Concrete Footerno scale
at earth / grass condition
2E.17
DETAIL
Specifications
SECTION E: PEDESTRIAN WAYFINDING
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
I Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and
appropriate wind-loads for
individual structure. Footer
to be below grade and
landscaping, by others,
where necessary.
J Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
K Expansion Joint To accommodate concrete
expansion and contraction.
L Sand Compacted sand for con-
densation drainage per
engineering requirements.
M Attachment Bracket Rutgers owned custom ex-
truded bracket cut to match
height of aluminum plate.
Permanently mount to back
of plate.
*See post extrusion spec. information on Parts sheet.
N Sign Panel Plate 1/8” Thk. aluminum plate cut
to dimensions shown
in elevations.
PEDESTRIAN DIRECTIONAL
PDR12
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
alig
n
PNL.4 (max. message)1” = 1’-0”
AB
CL
C L -
typ
.
3" 2 1/4" 1'-4 1/4"- max. copy length
3"2"
-ty
p.
4"-
typ
.
1 1/
4"
2E.18
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.18
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
GRAPHIC LAYOUTS
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Copy 1 1/4” X-cap Height.
Type: T2. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
B Arrow_Symbol.eps 1 3/4” Height.
Artwork provided by client.
Apply to front surface
of panel.
Applied Vinyl: V2. Rotate arrow around object
center-point.
PDR12PEDESTRIAN DIRECTIONAL
Visitors Must UseMain Entrance
University BehavioralHealth Care
No more than SIX messagesper sign.
ONLY includeparking messageson parking panels
No more than THREE lines per message.
Panels must MATCH the 27’’baseline.
Do NOT rearrangepanels.
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessageMessageMessageMessage
MessageMessage
MessageMessage
Message
Message
Message
Message
Message
MessageMessage
Lot XXAddress
Lot XXAddress
Lot XXAddress
Lot XXAddress
Lot XXAddress
Lot XXAddress
PNL.3- Variation1” = 1’-0”
C2 3/
8"1
5/8"
1"
2E.19
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
2E.19
GRAPHIC DONT’S
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
C Secondary Copy 1” X-cap Height.
Type: T1. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
GRAPHIC LAYOUTS
SECTION E: PEDESTRIAN WAYFINDING
PEDESTRIAN DIRECTIONAL
PDR12
2E.20 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
This Page Intentionally Left Blank
Lot XX
Lot XX
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
MessageMessage
Configuration 1 Configuration 2
26"
a
C
D
HB
E
G
F
I
J
Full length filler panels are used for single sided signs only. (not shown)
Stop panel below grade line. (not shown)
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
CONFIGURATIONS
PDR13
PART COUNTS
POST CAP POST CAP
SIGN POST SIGN POST
PNL.1 PNL.1
FP_1 FP_1
PNL.2 PNL.3
PNL.4
FP_2
FP_2
FP_3
FP_3
FP_S
FP_S
2 2
2 2
1 1
4 4
1 1
1
2
2
2
2
4
4
2 2
2 2
2 2
8 8
2 2
2
4
4
0
0
4
4
CONFIGURATION 1: CONFIGURATION 2:
SINGLE SIDED
SINGLE SIDED
DOUBLE SIDED
DOUBLE SIDED
A A
B B
C C
D D
E E
G H
H
I
I
J
J
* *
* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.
For specification and ordering purposes, contact EMS Delaware;
231 Executive Drive Suite 11
Newark, DE 19702 USA
Toll Free: 800-863-1496
Local Phone: 302-391-1370
Fax: 302-391-1371
Website: www.EasternMetal.com
Email: [email protected]
PEDESTRIAN DIRECTIONAL
Helpful Hints
• Keep in mind the intuitive
path of the user when locat-
ing and specifying exterior
directional signs.
• Use only standard and
approved nomenclature
and abbreviations.
• Refer to all appropriate state
and local codes, as needed,
for sign compliance, includ-
ing, but not limited to zon-
ing, ADAAG, MUTCD, etc.
• Sign fabricator to provide
all relevant engineering
calculations and provide all
methods and materials
of construction in
shop drawings.
Guidelines
• Provide pedestrians with
sequential guidance
throughout the campus with
strategic placement and
programmed messaging.
• Reinforce the brand equity
in the built environment with
brand color on the header.
• Use as a single-sided or
double-sided sign. Message
standards apply to both sides
of sign. It is acceptable to
use a different configuration
on each side.
• Locate signs at key decision
points and at locations
of optimal line of sight
from public buildings and
campus core.
• Arrow order should be as
follows: Up (straight),
Left, Right.
• Do not rearrange panel order.
PARTS
2E.21
Questions? Please contact xxxxx
?
SECTION E: PEDESTRIAN WAYFINDING
Lot XX
Lot XX
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
MessageMessage
eq.
6"eq
.
1'-4
"
3/4"2'-0"- graphic panel
3/4"
3 1/4" 1'-7" 3 1/4"
eq. 2'-1 1/2" eq.
2'-9 1/2"
1/8"
4"2"
min
.
5'-2
"
1"1'
-9"
1"8"
1"8"
2'-2
"
2'-6
"
1"
8"
grade line
CEF
CEF
G
G
IBA
I
PDR11: Configuration 1 3/4” = 1’-0”
Plan Elevation-Single side Sign(double side panels shown dashed)
DR33: Configuration 1, 21/2” = 1’-0”
PDR11: Configuration 23/4” = 1’-0”
Back Elevation- Single side Sign(panel configurationvaries, 1 shown)
KL
KL
A
CD
D
D
BH
E
G
G
F
J
2E.22
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post
cap, mechanically fastened
w/ tamper-resistant, span-
ner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.2 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
F PNL.3 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P3.
*Use one panel only for single sided sign.
PDR13PEDESTRIAN DIRECTIONAL
2E.23
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
This Page Intentionally Left Blank
G PNL.4 Painted aluminum panel
w/ applied vinyl graphics.
Custom extruded panel
attachment to be mounted
to back of panel w/ hi-bond
adhesive. Paint all sides: P3.
*Use one panel only for single sided sign.
H FP_4 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
I FP_7 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1. *Use only for single sided signs.
J FP_S 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
K Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
L Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
SECTION E: PEDESTRIAN WAYFINDING
PEDESTRIAN DIRECTIONAL
PDR13
becomessign panel
Component Parts /Assembly
Finished Sign
C
A
O
D
B
EFG
H
I
P
M
N
2E.24
DETAIL
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR13PEDESTRIAN DIRECTIONAL
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.2 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
F PNL.3 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P3.
*Use one panel only for single sided sign.
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
3'-2" panel length
3/4" 1 3/4" 3/4"
3 1/4"
1/8"typ.
2"
1/8"
typ
.
7/8"
4 1/
4"7/
8"
6"
1/8"7/8"
1/8"
1 1/8"
1/4"
pan
el e
xtru
sio
n v
arie
s-se
e el
evat
ion
s fo
r h
eig
ht
dim
ensi
on
s
1/4"
pan
el h
eig
ht
vari
es-
see
elev
atio
ns
for
hei
gh
t d
imen
sio
ns
4" a
bov
e fi
nis
hed
gra
de
Partial Horizontal Section 6” = 1’-0”
Vertical Section: Concrete Footerno scale
Plan Elevation at Sidewalkno scale
Panel Detail no scale
EFG
EFG
G
B
P
O
O
P
grade line grade line
B
l
m
N
K
K
L
M
at concrete sidewalk condition
Vertical Section: Concrete Footerno scale
at earth / grass condition
2E.25
DETAIL
Specifications
SECTION E: PEDESTRIAN WAYFINDING
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT PEDESTRIAN DIRECTIONAL
PDR13
G PNL.4 Painted aluminum panel
w/ applied vinyl graphics.
Custom extruded panel
attachment to be mounted
to back of panel w/ hi-bond
adhesive. Paint all sides: P2.
*Use one panel only for single sided sign.
H FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
I FP_7 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1. *Use only for single sided signs.
K Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
L Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
M Expansion Joint To accommodate concrete
expansion and contraction.
N Sand Compacted sand for con-
densation drainage per
engineering requirements.
O Attachment Bracket Rutgers owned custom ex-
truded bracket cut to match
height of aluminum plate.
Permanently mount to back
of plate.
*See post extrusion spec. information on Parts sheet.
P Sign Panel Plate 1/8” Thk. aluminum plate cut
to dimensions shown
in elevations.
Lot XXAddress
Up to TwoLine Message
Up to TwoLine Message
Up to Three LineMessage
alig
n
Up to Two Line Message
Up to Two Line Message
Up to Two Line Message
Up toThree LineMessage
alig
naB
B
d
C
a
PNL.3 (max. message)1” = 1’-0”
PNL.2 (max. message)1” = 1’-0”
PNL.3 (max. message)1” = 1’-0”
C L
CL
C L -
typ
.
CL CL
3" 2 1/4" 1'-4 1/4"- max. copy length
3"2"
-ty
p.
4"-
typ
.
1 1/
4"1
1/4"
1 1/
4"
3" 2 5/8" 1 1/2"1'-2 1/2"-
max. copy length
3 3/
16"
2"
2E.26
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.26
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
GRAPHIC LAYOUTS
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Copy 1 1/4” X-cap Height.
Type: T2. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
B Arrow_Symbol.eps 1 3/4” Height.
Artwork provided by client.
Apply to front surface
of panel.
Applied Vinyl: V2. Rotate arrow around object
center-point.
C Copy 1 1/4” X-cap Height.
Type: T1. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
D Parking_Symbol.eps 1 1/2” Height.
Artwork provided by client.
Apply to front surface
of panel.
Applied Vinyl: V2, V1.
PDR13PEDESTRIAN DIRECTIONAL
Visitors Must UseMain Entrance
University BehavioralHealth Care
No more than SIX messagesper sign.
ONLY includeparking messageson parking panels
No more than THREE lines per message.
Panels must MATCH the 26’’baseline.
Do NOT rearrangepanels.
Lot XX
Lot XX
Address
Address
Message
Message
Message
Message
Message
Lot XX
Lot XX
Address
Address
MessageMessage
MessageMessageMessageMessageMessageMessage
Lot XX
Lot XX
Address
Address
Lot XX
Lot XX
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
Lot XX
Lot XX
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
Lot XXAddress
Lot XXAddress
Lot XXAddress
PNL.2/PNL.3- Variation1” = 1’-0”
E2 3/
8"1
5/8"
1"
2E.27
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
2E.27
GRAPHIC DONT’S
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
E Secondary Copy 1” X-cap Height.
Type: T1. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
GRAPHIC LAYOUTS
SECTION E: PEDESTRIAN WAYFINDING
PEDESTRIAN DIRECTIONAL
PDR13
2E.28 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
This Page Intentionally Left Blank
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
Lot XXAddress
Configuration 1
18"
a
C
D
GB
E
F
H
I
Full length filler panels are used for single sided signs only. (not shown)
Stop panel below grade line. (not shown)
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR14
PART COUNTS
CONFIGURATIONS
PART COUNTS
POST CAP
SIGN POST
PNL.1
FP_1
PNL.5
PNL.4
FP_5
FP_7
FP_S
2
2
1
4
1
1
2
2
4
2
2
2
8
2
2
4
0
4
CONFIGURATION 1:
SINGLE SIDED
DOUBLE SIDED
A
B
C
D
E
F
G
H
I
*
* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.
For specification and ordering purposes, contact EMS Delaware;
231 Executive Drive Suite 11
Newark, DE 19702 USA
Toll Free: 800-863-1496
Local Phone: 302-391-1370
Fax: 302-391-1371
Website: www.EasternMetal.com
Email: [email protected]
PEDESTRIAN DIRECTIONAL
Helpful Hints
• Keep in mind the intuitive
path of the user when locat-
ing and specifying exterior
directional signs.
• Use only standard and
approved nomenclature
and abbreviations.
• Refer to all appropriate state
and local codes, as needed,
for sign compliance, includ-
ing, but not limited to zon-
ing, ADAAG, MUTCD, etc.
• Sign fabricator to provide
all relevant engineering
calculations and provide all
methods and materials
of construction in
shop drawings.
Guidelines
• Provide pedestrians with
sequential guidance
throughout the campus with
strategic placement and
programmed messaging.
• Reinforce the brand equity
in the built environment with
brand color on the header.
• Use as a single-sided or
double-sided sign. Message
standards apply to both sides
of sign. It is acceptable to
use a different configuration
on each side.
• Locate signs at key decision
points and at locations
of optimal line of sight
from public buildings and
campus core.
• Arrow order should be as
follows: Up (straight),
Left, Right.
• Do not rearrange panel order.
PARTS
2E.29
Questions? Please contact xxxxx
?
SECTION E: PEDESTRIAN WAYFINDING
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
Lot XXAddress
1/8"
4"1"
2" m
in.
5'-2
"
eq.
6"eq
.
1'-4
"
3/4"2'-0"- graphic panel
3/4"
3 1/4" 1'-7" 3 1/4"
eq. 2'-1 1/2" eq.
2'-9 1/2"
3'-2
"1"
8"1'
-6"
grade line
A
CD
BG
CEF
CEF
G
G
E
F
HBA
g
PDR12 3/4” = 1’-0”
Plan Elevation-Single side Sign(double side panels shown dashed)
DR33: Configuration 1, 21/2” = 1’-0”
Back Elevation- Single side Sign
JK
JK
I
2E.30
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.5 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
F PNL.4 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P3.
*Use one panel only for single sided sign.
PDR14PEDESTRIAN DIRECTIONAL
2E.31
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
This Page Intentionally Left Blank
G FP_5 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
H FP_7 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1. *Use only for single sided signs.
I FP_S 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
J Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
K Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
SECTION E: PEDESTRIAN WAYFINDING
PEDESTRIAN DIRECTIONAL
PDR14
becomessign panel
Component Parts /Assembly
Finished Sign
C
A
O
D
B
FE
G
H
P
M
N
2E.32
DETAIL
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.5 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
F PNL.4 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P3.
*Use one panel only for single sided sign.
G FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
PDR14PEDESTRIAN DIRECTIONAL
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
3'-2" panel length
3/4" 1 3/4" 3/4"
3 1/4"
1/8"typ.
2"
1/8"
typ
.
7/8"
4 1/
4"7/
8"
6"
1/8"7/8"
1/8"
1 1/8"
1/4"
pan
el e
xtru
sio
n v
arie
s-se
e el
evat
ion
s fo
r h
eig
ht
dim
ensi
on
s
1/4"
pan
el h
eig
ht
vari
es-
see
elev
atio
ns
for
hei
gh
t d
imen
sio
ns
4" a
bov
e fi
nis
hed
gra
de
Partial Horizontal Section 6” = 1’-0”
Vertical Section: Concrete Footerno scale
Plan Elevation at Sidewalkno scale
Panel Detail no scale
EF
EF
G
B
O
N
N
O
grade line grade line
B
K
L
M
J
J
K
L
at concrete sidewalk condition
Vertical Section: Concrete Footerno scale
at earth / grass condition
2E.33
DETAIL
Specifications
SECTION E: PEDESTRIAN WAYFINDING
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
H FP_7 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1. *Use only for single sided signs.
J Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
K Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
L Expansion Joint To accommodate concrete
expansion and contraction.
M Sand Compacted sand for con-
densation drainage per
engineering requirements.
N Attachment Bracket Rutgers owned custom ex-
truded bracket cut to match
height of aluminum plate.
Permanently mount to back
of plate.
*See post extrusion spec. information on Parts sheet.
O Sign Panel Plate 1/8” Thk. aluminum plate cut
to dimensions shown
in elevations.
PEDESTRIAN DIRECTIONAL
PDR14
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
alig
n
Lot XXAddress
PNL.4 (max. message)1” = 1’-0”
AB
CL
C L -
typ
.
B
d
C
a
PNL.3 (max. message)1” = 1’-0”
C L
CL CL
3" 2 1/4" 1'-4 1/4"- max. copy length
3"2"
-ty
p.
4"-
typ
.
1 1/
4"1
1/4"
1 1/
4"
3" 2 5/8" 1 1/2"1'-2 1/2"-
max. copy length
3 3/
16"
2"
2E.34
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.34
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
GRAPHIC LAYOUTS
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Copy 1 1/4” X-cap Height.
Type: T2. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
B Arrow_Symbol.eps 1 3/4” Height.
Artwork provided by client.
Apply to front surface
of panel.
Applied Vinyl: V2. Rotate arrow around object
center-point.
C Copy 1 1/4” X-cap Height.
Type: T1. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
D Parking_Symbol.eps 1 1/2” Height.
Artwork provided by client.
Apply to front surface
of panel.
Applied Vinyl: V2, V1.
PDR14PEDESTRIAN DIRECTIONAL
Visitors Must UseMain Entrance
University BehavioralHealth Care
No more than SIX messagesper sign.
ONLY includeparking messageson parking panels
No more than THREE lines per message.
Panels must MATCH the 18’’baseline.
Do NOT rearrangepanels.
MessageMessage
MessageMessage
Message
Message
Message
Message
Message
MessageMessage
Lot XXAddress
MessageMessageMessageMessageMessage
Lot XXAddress
Lot XXAddress
Lot XXAddress
Lot XXAddress
Lot XXAddress
Lot XXAddress
Lot XXAddress
Lot XXAddress
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
Lot XXAddress
E
PNL.2/PNL.3- Variation1” = 1’-0”
2 3/
8"1
5/8"
1"
MessageMessage
MessageMessage
MessageMessage
2E.35
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
2E.35
GRAPHIC DONT’S
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
E Secondary Copy 1” X-cap Height.
Type: T1. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
GRAPHIC LAYOUTS
SECTION E: PEDESTRIAN WAYFINDING
PEDESTRIAN DIRECTIONAL
PDR14
2E.36 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
This Page Intentionally Left Blank
Lot XX
Lot XX
Lot XX
Address
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
Lot XX
Lot XX
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
MessageMessage
Configuration 1 Configuration 2
17"
a
C
D
HB
E
G
F
I
J
Full length filler panels are used for single sided signs only. (not shown)
Stop panel below grade line. (not shown)
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR15
PART COUNTS
CONFIGURATIONS
PART COUNTS
POST CAP POST CAP
SIGN POST SIGN POST
PNL.1 PNL.1
FP_1 FP_1
PNL.2 PNL.3
PNL.5 PNL.5
FP_6 FP_6
FP_7 FP_7
FP_S FP_S
2 2
2 2
1 1
4 4
1 1
1 1
2 2
2 2
4 4
2 2
2 2
2 2
8 8
2 2
2 2
4 4
0 0
4 4
CONFIGURATION 1: CONFIGURATION 2:
SINGLE SIDED
SINGLE SIDED
DOUBLE SIDED
DOUBLE SIDED
A A
B B
C C
D D
E E
G G
H H
I I
J J
* *
* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.
For specification and ordering purposes, contact EMS Delaware;
231 Executive Drive Suite 11
Newark, DE 19702 USA
Toll Free: 800-863-1496
Local Phone: 302-391-1370
Fax: 302-391-1371
Website: www.EasternMetal.com
Email: [email protected]
PEDESTRIAN DIRECTIONAL
Helpful Hints
• Keep in mind the intuitive
path of the user when locat-
ing and specifying exterior
directional signs.
• Use only standard and
approved nomenclature
and abbreviations.
• Refer to all appropriate state
and local codes, as needed,
for sign compliance, includ-
ing, but not limited to zon-
ing, ADAAG, MUTCD, etc.
• Sign fabricator to provide
all relevant engineering
calculations and provide all
methods and materials
of construction in
shop drawings.
Guidelines
• Provide pedestrians with
sequential guidance
throughout the campus with
strategic placement and
programmed messaging.
• Reinforce the brand equity
in the built environment with
brand color on the header.
• Use as a single-sided or
double-sided sign. Message
standards apply to both sides
of sign. It is acceptable to
use a different configuration
on each side.
• Locate signs at key decision
points and at locations
of optimal line of sight
from public buildings and
campus core.
• Arrow order should be as
follows: Up (straight),
Left, Right.
• Do not rearrange panel order.
PARTS
2E.37
Questions? Please contact xxxxx
?
SECTION E: PEDESTRIAN WAYFINDING
Lot XX
Lot XX
Lot XX
Address
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
Lot XX
Lot XX
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
MessageMessage
eq.
6"eq
.
1'-4
"
3/4"2'-0"- graphic panel
3/4"
3 1/4" 1'-7" 3 1/4"
eq. 2'-1 1/2" eq.
2'-9 1/2"
1/8"
4"2"
min
.
5'-2
"
1"1'
-9"
1"8"
1"8"
2'-6
"
1"8"
1'-5
"
grade line
CEF
CEF
G
G
IBA
I
PDR11: Configuration 1 3/4” = 1’-0”
Plan Elevation-Single side Sign(double side panels shown dashed)
DR33: Configuration 1, 21/2” = 1’-0”
PDR11: Configuration 23/4” = 1’-0”
Back Elevation- Single side Sign(panel configurationvaries, 1 shown)
KL
KL
A
CD
D
D
BH
E
G
G
D
G
F
J
2E.38
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.2 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
F PNL.3 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P3.
*Use one panel only for single sided sign.
PDR15PEDESTRIAN DIRECTIONAL
2E.39
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
This Page Intentionally Left Blank
G PNL.5 Painted aluminum panel
w/ applied vinyl graphics.
Custom extruded panel
attachment to be mounted
to back of panel w/ hi-bond
adhesive. Paint all sides: P3.
*Use one panel only for single sided sign.
H FP_6 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
I FP_7 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1. *Use only for single sided signs.
J FP_S 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
K Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
L Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
SECTION E: PEDESTRIAN WAYFINDING
PEDESTRIAN DIRECTIONAL
PDR15
becomessign panel
Component Parts /Assembly
Finished Sign
C
A
O
D
B
EFG
H
I
P
M
N
2E.40
DETAIL
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post
cap, mechanically fastened
w/ tamper-resistant, span-
ner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.2 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
F PNL.3 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P3.
*Use one panel only for single sided sign.
PDR15PEDESTRIAN DIRECTIONAL
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
3'-2" panel length
3/4" 1 3/4" 3/4"
3 1/4"
1/8"typ.
2"
1/8"
typ
.
7/8"
4 1/
4"7/
8"
6"
1/8"7/8"
1/8"
1 1/8"
1/4"
pan
el e
xtru
sio
n v
arie
s-se
e el
evat
ion
s fo
r h
eig
ht
dim
ensi
on
s
1/4"
pan
el h
eig
ht
vari
es-
see
elev
atio
ns
for
hei
gh
t d
imen
sio
ns
4" a
bov
e fi
nis
hed
gra
de
Partial Horizontal Section 6” = 1’-0”
Vertical Section: Concrete Footerno scale
Plan Elevation at Sidewalkno scale
Panel Detail no scale
EF
EF
G
B
P
O
O
P
grade line grade line
B
l
m
N
K
K
L
M
at concrete sidewalk condition
Vertical Section: Concrete Footerno scale
at earth / grass condition
2E.41
DETAIL
Specifications
SECTION E: PEDESTRIAN WAYFINDING
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
G PNL.5 Painted aluminum panel
w/ applied vinyl graphics.
Custom extruded panel
attachment to be mounted
to back of panel w/ hi-bond
adhesive. Paint all sides: P2.
*Use one panel only for single sided sign.
H FP_6 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
I FP_7 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1. *Use only for single sided signs.
K Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
L Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
M Expansion Joint To accommodate concrete
expansion and contraction.
N Sand Compacted sand for con-
densation drainage per
engineering requirements.
O Attachment Bracket Rutgers owned custom ex-
truded bracket cut to match
height of aluminum plate.
Permanently mount to back
of plate.
*See post extrusion spec. information on Parts sheet.
P Sign Panel Plate 1/8” Thk. aluminum plate
cut to dimensions shown in
elevations.
PEDESTRIAN DIRECTIONAL
PDR15
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
Up to TwoLine Message
alig
n
Lot XXAddress
PNL.4 (max. message)1” = 1’-0”
AB
CL
C L -
typ
.
B
d
C
a
PNL.3 (max. message)1” = 1’-0”
C L
CL CL
3" 2 1/4" 1'-4 1/4"- max. copy length
3"2"
-ty
p.
4"-
typ
.
1 1/
4"1
1/4"
1 1/
4"
3" 2 5/8" 1 1/2"1'-2 1/2"-
max. copy length
3 3/
16"
2"
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
GRAPHIC LAYOUTS
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
2E.422E.42
A Copy 1 1/4” X-cap Height.
Type: T2. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
B Arrow_Symbol.eps 1 3/4” Height.
Artwork provided by client.
Apply to front surface
of panel.
Applied Vinyl: V2. Rotate arrow around object
center-point.
C Copy 1 1/4” X-cap Height.
Type: T1. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
D Parking_Symbol.eps 1 1/2” Height.
Artwork provided by client.
Apply to front surface
of panel.
Applied Vinyl: V2, V1.
PDR15PEDESTRIAN DIRECTIONAL
Visitors Must UseMain Entrance
University BehavioralHealth Care
No more than SIX messagesper sign.
ONLY includeparking messageson parking panels
No more than THREE lines per message.
Panels must MATCH the 17’’baseline.
Do NOT rearrangepanels.
Lot XX
Lot XX
Address
Address
MessageMessageMessage
MessageMessage
MessageMessage
Lot XX
Lot XX
Lot XX
Address
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
MessageMessage
Lot XXAddress
Lot XX
Lot XX
Address
Address
MessageMessageMessageMessageMessageMessage
MessageMessage
MessageMessage
Lot XX
Lot XX
Address
Address
Lot XXAddress
Lot XXAddress
Lot XXAddressLot XXAddress
Lot XXAddress
E
PNL.2/PNL.3- Variation1” = 1’-0”
2 3/
8"1
5/8"
1"
2E.43
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
2E.43
GRAPHIC DONT’S
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
E Secondary Copy 1” X-cap Height.
Type: T1. Tracking: +50.
Apply to front surface
of panel.
Applied Vinyl: V2.
GRAPHIC LAYOUTS
SECTION E: PEDESTRIAN WAYFINDING
PEDESTRIAN DIRECTIONAL
PDR15
2E.442E.44 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
This Page Intentionally Left Blank
SUB-SECTION
SECTION E:
PDR20 SERIES
2E.46 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PDR20 Series – Directional with Map
PDR21Config. 2
PDR22 PDR23Config. 1
PDR21Config. 1
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessageMessage
Lot XXAddress
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
PDR23Config. 2
PDR24Config. 2
PDR25Config. 2
PDR25Config. 1
Lot XXAddress
MessageMessage
MessageMessage
MessageMessage
MessageMessageMessage
Lot XXAddress
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
Lot XXAddress
Lot XXAddress
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
Lot XXAddress
Lot XXAddress
MessageMessage
MessageMessage
MessageMessage
MessageMessageMessage
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
1 MSG 2 MSG 3 MSG 4 MSG 5 MSG 6 MSG4 MSG
+ 1 PARK
4 MSG
+ 2 PARK
3 MSG
+ 3 PARK
3 MSG
+ 1 PARK
3 MSG
+ 2 PARK
3 ARROW N/A N/A N/A N/A N/A N/A N/A
PDR225 ARROW N/A N/A N/A N/AN/AN/AN/AN/A
4 ARROW N/A N/A N/AN/A N/AN/AN/AN/A N/A
PDR226 ARROW N/A N/A N/A N/A N/A N/A N/A N/A
2 ARROW N/A N/A N/A N/A N/A N/A
N/A N/A N/A
N/A N/A N/A N/A
1 ARROW N/APDR21
Config. 2
PDR21Config. 2
N/A N/A N/A N/A N/A N/A N/A N/A N/A
PDR20 SERIES:
PDR21Config. 2
PDR21Config. 2
PDR21Config. 1
PDR23Config. 1
PDR25Config. 2
PDR25Config. 1
PDR25Config. 2
PDR23Config. 2
PDR24Config. 2
PDR20 Series Overview
Recommended sign type
configurations shown.
Additional module
configurations must be
approved by Rutgers
University Environmental
Graphics Coordinator &
or Department of Facilities,
Planning and Development.
Below are the following steps for
selecting the correct pedestrian
directional for your needs.
A. Determine the number of
messages and parking messages
you require. Verify “heads up”
map orientation and artwork per
sign placement.
B. Determine message lengths
and character (letter) counts for
each message. Are your
messages 1, 2 or 3 lines long?
C. Select from the typical module
heights based on previous steps.
See graphic layout pages for
sample typographic layouts and
map artwork guidelines.
.
D. Review graphic dont’s to
ensure proper selection.
Sign Selection Process
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
MessageMessage
MessageMessage
MessageMessage
MessageMessageMessage
Configuration 1 Configuration 2
27"
a
C
D
B
E
F
E
G Structural attachment angle (not shown)
Full length filler panels are used for single sided signs only. (not shown)
Stop panel below grade line. (not shown)
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR21
* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.
For specification and ordering purposes, contact EMS Delaware;
231 Executive Drive Suite 11
Newark, DE 19702 USA
Toll Free: 800-863-1496
Local Phone: 302-391-1370
Fax: 302-391-1371
Website: www.EasternMetal.com
Email: [email protected]
CONFIGURATIONS
DIRECTIONAL WITH MAP
Helpful Hints
• Keep in mind the intuitive path of
the user when locating and spec-
ifying exterior directional signs.
• Use only standard and
approved nomenclature
and abbreviations.
• Refer to all appropriate state
and local codes, as needed, for
sign compliance, including, but
not limited to zoning, ADAAG,
MUTCD, etc.
• Sign fabricator to provide
all relevant engineering calcu-
lations and provide all methods
and materials of construction in
shop drawings
Guidelines
• Provide pedestrians with sequential
guidance throughout the campus
with strategic placement and
programmed messaging.
• Reinforce the brand equity in the
built environment with brand color
on the header.
• Use as a single-sided or
double-sided sign. Message
standards apply to both sides
of sign. It is acceptable to use
a different configuration on
each side.
• Locate signs at key decision points
and at locations of optimal line of
sight from public buildings and
campus core.
• Arrow order should be as follows:
Up (straight), Left, Right.
• Do not rearrange panel order.
• Map orientation to match view of
pedestrian when standing at the
sign. What is shown ahead of you
on the map should appear ahead
of you.
• Contact Rutgers University
Environmental Graphics
Coordinator and or Department
of Facilities, Planning and
Development for correct
map artwork.
PART COUNTS
POST CAP POST CAP
SIGN POST SIGN POST
PNL.1 PNL.1
FP_1 FP_1
PNL.2 PNL.3
PNL.4
FP_2
FP_2
FP_3
FP_3
FP_S
FP_S
2 2
2 2
1 1
6 6
1 1
1
2
2
2
2
4
4
2 2
2 2
2 2
10 10
2 2
2
4
4
0
0
4
4
CONFIGURATION 1: CONFIGURATION 2:
SINGLE SIDED
SINGLE SIDED
DOUBLE SIDED
DOUBLE SIDED
A A
B B
C C
D D
E E
G H
H
I
I
J
J
* *
PARTS
2E.47
Questions? Please contact xxxxx
?
SECTION E: PEDESTRIAN WAYFINDING
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
4"6"
4"
1'-4
"
2'-0"- graphic panel3/4"
1'-9 1/2" 3 1/4"
See PDR11, Configuration 1 forsign components, details
and graphic layouts.
See PDR11, Configuration 1 forsign components, details
and graphic layouts.
2" m
in.
2'-3
"2'
-6"
4'-9
"
1/8"
4" 4'-1 3/4" 4"
4'-9 3/4"
aligns to top of panel
aligns to bottomof panel
grade line
A
BD
CG
C
C
BA
F
E
PDR21: Configuration 1 3/4” = 1’-0”
Plan Elevation-Single side Sign(double side panels shown dashed)
See PDR11Configuration 1for sign components, details and graphic layouts.
PDR21: Configuration 1, 21/2” = 1’-0”
GI
GH
2E.48
ELEVATION
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
PDR21DIRECTIONAL WITH MAP
This Page Intentionally Left Blank
2E.49
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
F FP_S 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
G Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
H Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
SECTION E: PEDESTRIAN WAYFINDING
DIRECTIONAL WITH MAP
PDR21
becomessign panel
Component Parts /Assembly
Finished Sign
C
A
O
D
B
EFG
H
I
P
M
N
2E.50
DETAIL
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PDR21
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
DIRECTIONAL WITH MAP
3'-2" panel length
3/4" 1 3/4" 3/4"
3 1/4"
1/8"typ.
2"
1/8"
typ
.
7/8"
4 1/
4"7/
8"
6"
1/8"7/8"
1/8"
1 1/8"
1/4"
pan
el e
xtru
sio
n v
arie
s-se
e el
evat
ion
s fo
r h
eig
ht
dim
ensi
on
s
1/4"
pan
el h
eig
ht
vari
es-
see
elev
atio
ns
for
hei
gh
t d
imen
sio
ns
4" a
bov
e fi
nis
hed
gra
de
Partial Horizontal Section 6” = 1’-0”
Vertical Section: Concrete Footerno scale
Plan Elevation at Sidewalkno scale
Panel Detail no scale
EFG
FE
G
G
B
P
O
O
P
grade line grade line
B
L
M
N
H
K
L
M
at concrete sidewalk condition
Vertical Section: Concrete Footerno scale
at earth / grass condition
2E.51
DETAIL
Specifications
SECTION E: PEDESTRIAN WAYFINDING
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR21
H Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
I Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
J Expansion Joint To accommodate concrete
expansion and contraction.
K Sand Compacted sand for con-
densation drainage per
engineering requirements.
L Attachment Bracket Rutgers owned custom ex-
truded bracket cut to match
height of aluminum plate.
Permanently mount to back
of plate.
*See post extrusion spec. information on Parts sheet.
M Sign Panel Plate 1/8” Thk. aluminum plate
cut to dimensions shown in
elevations.
DIRECTIONAL WITH MAP
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
a
PNL.11” = 1’-0”
GRAPHIC FOR
PLACEMENT ONLY
2E.52
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.52
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
GRAPHIC LAYOUTS
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
DIRECTIONAL WITH MAP
PDR21
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
27"
a
C
D
B
E
F
E
G Structural attachment angle (not shown)
Full length filler panels are used for single sided signs only. (not shown)
Stop panel below grade line. (not shown)
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR22
* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.
For specification and ordering purposes, contact EMS Delaware;
231 Executive Drive Suite 11
Newark, DE 19702 USA
Toll Free: 800-863-1496
Local Phone: 302-391-1370
Fax: 302-391-1371
Website: www.EasternMetal.com
Email: [email protected]
CONFIGURATIONS
Helpful Hints
• Keep in mind the intuitive path of
the user when locating and spec-
ifying exterior directional signs.
• Use only standard and
approved nomenclature
and abbreviations.
• Refer to all appropriate state
and local codes, as needed, for
sign compliance, including, but
not limited to zoning, ADAAG,
MUTCD, etc.
• Sign fabricator to provide
all relevant engineering calcu-
lations and provide all methods
and materials of construction in
shop drawings
Guidelines
• Provide pedestrians with sequential
guidance throughout the campus
with strategic placement and
programmed messaging.
• Reinforce the brand equity in the
built environment with brand color
on the header.
• Use as a single-sided or
double-sided sign. Message
standards apply to both sides
of sign. It is acceptable to use
a different configuration on
each side.
• Locate signs at key decision points
and at locations of optimal line of
sight from public buildings and
campus core.
• Arrow order should be as follows:
Up (straight), Left, Right.
• Do not rearrange panel order.
• Map orientation to match view of
pedestrian when standing at the
sign. What is shown ahead of you
on the map should appear ahead
of you.
• Contact Rutgers University
Environmental Graphics
Coordinator and or Department
of Facilities, Planning and
Development for correct
map artwork.
PART COUNTS
POST CAP
SIGN POST
PNL.1
FP_1
PNL.5
FP_2
FP_7
FP_S
2
2
1
2
1
2
2
4
2
2
2
4
2
4
0
4
CONFIGURATION 1:
SINGLE SIDED
DOUBLE SIDED
A
B
C
D
E
F
G
H
*
PARTS
DIRECTIONAL WITH MAP
2E.53
Questions? Please contact xxxxx
?
SECTION E: PEDESTRIAN WAYFINDING
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
4"6"
4"
1'-4
"2'-0"- graphic panel
3/4"
1'-9 1/2" 3 1/4"
See PDR12, Configuration 1 forsign components, details
and graphic layouts.
See PDR11, Configuration 1 forsign components, details
and graphic layouts.
2" m
in.
2'-3
"3'
-2"
5'-5
"
1/8"
4" 4'-1 3/4" 4"
4'-9 3/4"
aligns to top of panel
aligns to bottomof panel
grade line
A
BD
CG
C
C
BA
F
E
PDR22: Configuration 1 3/4” = 1’-0”
Plan Elevation-Single side Sign(double side panels shown dashed)
See PDR11Configuration 1for sign components, details and graphic layouts.
PDR22: Configuration 1, 21/2” = 1’-0”
GI
GH
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
2E.54
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
DIRECTIONAL WITH MAP
PDR22
This Page Intentionally Left Blank
2E.55
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
F FP_S 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
G Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
H Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
SECTION E: PEDESTRIAN WAYFINDING
PDR22DIRECTIONAL WITH MAP
1/8"7/8"
1/8"
1 1/8"
1/4"
pan
el e
xtru
sio
n v
arie
s-se
e el
evat
ion
s fo
r h
eig
ht
dim
ensi
on
s
1/4"
pan
el h
eig
ht
vari
es-
see
elev
atio
ns
for
hei
gh
t d
imen
sio
ns
be
co
me
ssi
gn
pa
ne
l
Component Parts /Assembly
Finished Sign
Panel Detail no scale
CL
M
A
M
B
C
D
E
N
M
N
G
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
2E.56
DETAIL
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR22
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
DIRECTIONAL WITH MAP
PDRPedestrian
Directional-see various
layouts,sheet 3.17.
4" a
bov
e fi
nis
hed
gra
de
2'-0"- graphic panel
3/4" 1 3/4" 3/4"
3 1/4"
7/8"
4 1/
4"7/
8"
6"
1/8"
typ
.
1/8"typ
2"
Partial Horizontal Section 3” = 1’-0”
Vertical Section: Concrete Footerno scale
Plan Elevation at Sidewalkno scale
C
L
M
g
grade line grade line
B
I
J
H
K
B
C
H
I
J
at concrete sidewalk condition
Vertical Section: Concrete Footerno scale
at earth / grass condition
2E.57
DETAIL
Specifications
SECTION E: PEDESTRIAN WAYFINDING
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR22
H Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
I Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
J Expansion Joint To accommodate concrete
expansion and contraction.
K Sand Compacted sand for con-
densation drainage per
engineering requirements.
L Attachment Bracket Rutgers owned custom ex-
truded bracket cut to match
height of aluminum plate.
Permanently mount to back
of plate.
*See post extrusion spec. information on Parts sheet.
M Sign Panel Plate 1/8” Thk. aluminum plate cut
to dimensions shown
in elevations.
DIRECTIONAL WITH MAP
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
a
PNL21” = 1’-0”
2E.58
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.58
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
GRAPHIC LAYOUTS
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
GRAPHIC FOR
PLACEMENT ONLY
PDR22DIRECTIONAL WITH MAP
2E.59
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
2E.59
GRAPHIC DONT’S
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
SECTION E: PEDESTRIAN WAYFINDING
PDR22
This Page Intentionally Left Blank
DIRECTIONAL WITH MAP
2E.60 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
This Page Intentionally Left Blank
Lot XX
Lot XX
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Lot XXAddress
MessageMessage
MessageMessage
MessageMessageMessage
MessageMessage
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Configuration 1 Configuration 2
26"
a
C
D
B
E
F
E
G Structural attachment angle (not shown)
Full length filler panels are used for single sided signs only. (not shown)
Stop panel below grade line. (not shown)
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR23
* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.
For specification and ordering purposes, contact EMS Delaware;
231 Executive Drive Suite 11
Newark, DE 19702 USA
Toll Free: 800-863-1496
Local Phone: 302-391-1370
Fax: 302-391-1371
Website: www.EasternMetal.com
Email: [email protected]
CONFIGURATIONS
Helpful Hints
• Keep in mind the intuitive path of
the user when locating and spec-
ifying exterior directional signs.
• Use only standard and
approved nomenclature
and abbreviations.
• Refer to all appropriate state
and local codes, as needed, for
sign compliance, including, but
not limited to zoning, ADAAG,
MUTCD, etc.
• Sign fabricator to provide
all relevant engineering calcu-
lations and provide all methods
and materials of construction in
shop drawings
Guidelines
• Provide pedestrians with sequential
guidance throughout the campus
with strategic placement and
programmed messaging.
• Reinforce the brand equity in the
built environment with brand color
on the header.
• Use as a single-sided or
double-sided sign. Message
standards apply to both sides
of sign. It is acceptable to use
a different configuration on
each side.
• Locate signs at key decision points
and at locations of optimal line of
sight from public buildings and
campus core.
• Arrow order should be as follows:
Up (straight), Left, Right.
• Do not rearrange panel order.
• Map orientation to match view of
pedestrian when standing at the
sign. What is shown ahead of you
on the map should appear ahead
of you.
• Contact Rutgers University
Environmental Graphics
Coordinator and or Department
of Facilities, Planning and
Development for correct
map artwork.
PART COUNTS
POST CAP POST CAP
SIGN POST SIGN POST
PNL.1 PNL.1
FP_1 FP_1
PNL.2 PNL.3
PNL.4
FP_2
FP_2
FP_3
FP_3
FP_S
FP_S
2 2
2 2
1 1
6 6
1 1
1
2
2
2
2
4
4
2 2
2 2
2 2
10 10
2 2
2
4
4
0
0
4
4
CONFIGURATION 1: CONFIGURATION 2:
SINGLE SIDED
SINGLE SIDED
DOUBLE SIDED
DOUBLE SIDED
A A
B B
C C
D D
E E
G H
H
I
I
J
J
* *
PARTS
DIRECTIONAL WITH MAP
2E.61
Questions? Please contact xxxxx
?
SECTION E: PEDESTRIAN WAYFINDING
Lot XX
Lot XX
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
4"6"
4"
1'-4
"
2'-0"- graphic panel3/4"
1'-9 1/2" 3 1/4"
See PDR11, Configuration 1 forsign components, details
and graphic layouts.
4" 4'-1 3/4" 4"
4'-9 3/4"
See PDR11, Configuration 1 forsign components, details
and graphic layouts.
2" m
in.
2'-2
"3'
-3"
5'-5
"
1/8"
aligns to top of panel
aligns to bottomof panel
CG
C
BA
E
PDR23: Configuration 1 3/4” = 1’-0”
Plan Elevation-Single side Sign(double side panels shown dashed)
PDR23z: Configuration 1, 21/2” = 1’-0”
GH
See PDR11Configuration 1for sign components, details and graphic layouts.
grade line
A
BD
C
F
GI
2E.62
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
F FP_S 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
G Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to con-
form to engineering require-
ments and appropriate wind-
loads for individual structure.
Footer to be Below grade and
landscaping, by others, where
necessary.
H Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square, pour
footer below sidewalk and
repour sidewalk square.
PDR23DIRECTIONAL WITH MAP
This Page Intentionally Left Blank
2E.63
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
SECTION E: PEDESTRIAN WAYFINDING
PDR23DIRECTIONAL WITH MAP
1/8"7/8"
1/8"
1 1/8"
1/4"
pan
el e
xtru
sio
n v
arie
s-se
e el
evat
ion
s fo
r h
eig
ht
dim
ensi
on
s
1/4"
pan
el h
eig
ht
vari
es-
see
elev
atio
ns
for
hei
gh
t d
imen
sio
ns
be
co
me
ssi
gn
pa
ne
l
Component Parts /Assembly
Finished Sign
Panel Detail no scale
CL
M
A
M
B
C
D
E
N
M
N
G
2E.64
DETAIL
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR23
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4
*Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
DIRECTIONAL WITH MAP
PDRPedestrian
Directional-see various
layouts,sheet 3.17.
4" a
bov
e fi
nis
hed
gra
de
2'-0"- graphic panel
3/4" 1 3/4" 3/4"
3 1/4"
7/8"
4 1/
4"7/
8"
6"
1/8"
typ
.
1/8"typ
2"
Partial Horizontal Section 3” = 1’-0”
Vertical Section: Concrete Footerno scale
Plan Elevation at Sidewalkno scale
C
L
M
g
grade line grade line
B
I
J
H
K
B
C
H
I
J
at concrete sidewalk condition
Vertical Section: Concrete Footerno scale
at earth / grass condition
2E.65
DETAIL
Specifications
SECTION E: PEDESTRIAN WAYFINDING
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR23
H Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
I Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
J Expansion Joint To accommodate concrete
expansion and contraction.
K Sand Compacted sand for con-
densation drainage per
engineering requirements.
L Attachment Bracket Rutgers owned custom ex-
truded bracket cut to match
height of aluminum plate.
Permanently mount to back
of plate.
*See post extrusion spec. information on Parts sheet.
M Sign Panel Plate 1/8” Thk. aluminum plate cut
to dimensions shown
in elevations.
DIRECTIONAL WITH MAP
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
a
PNL21” = 1’-0”
GRAPHIC FOR
PLACEMENT ONLY
2E.66
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.66
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
A PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
PDR23
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
DIRECTIONAL WITH MAP
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
Lot XXAddress
27"
a
C
D
B
E
F
E
G Structural attachment angle (not shown)
Full length filler panels are used for single sided signs only. (not shown)
Stop panel below grade line. (not shown)
Configuration 1
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR24
* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.
For specification and ordering purposes, contact EMS Delaware;
231 Executive Drive Suite 11
Newark, DE 19702 USA
Toll Free: 800-863-1496
Local Phone: 302-391-1370
Fax: 302-391-1371
Website: www.EasternMetal.com
Email: [email protected]
CONFIGURATIONS
Helpful Hints
• Keep in mind the intuitive path of
the user when locating and spec-
ifying exterior directional signs.
• Use only standard and
approved nomenclature
and abbreviations.
• Refer to all appropriate state
and local codes, as needed, for
sign compliance, including, but
not limited to zoning, ADAAG,
MUTCD, etc.
• Sign fabricator to provide
all relevant engineering calcu-
lations and provide all methods
and materials of construction in
shop drawings
Guidelines
• Provide pedestrians with sequential
guidance throughout the campus
with strategic placement and
programmed messaging.
• Reinforce the brand equity in the
built environment with brand color
on the header.
• Use as a single-sided or
double-sided sign. Message
standards apply to both sides
of sign. It is acceptable to use
a different configuration on
each side.
• Locate signs at key decision points
and at locations of optimal line of
sight from public buildings and
campus core.
• Arrow order should be as follows:
Up (straight), Left, Right.
• Do not rearrange panel order.
• Map orientation to match view of
pedestrian when standing at the
sign. What is shown ahead of you
on the map should appear ahead
of you.
• Contact Rutgers University
Environmental Graphics
Coordinator and or Department
of Facilities, Planning and
Development for correct
map artwork.
PART COUNTSPART COUNTS
POST CAP
SIGN POST
PNL.1
FP_1
PNL.5
PNL.4
FP_5
FP_7
FP_S
2
2
1
6
1
1
2
2
4
2
2
2
10
2
2
4
0
4
CONFIGURATION 1:
SINGLE SIDED
DOUBLE SIDED
A
B
C
D
E
F
G
H
I
*
PARTS
DIRECTIONAL WITH MAP
2E.67
Questions? Please contact xxxxx
?
SECTION E: PEDESTRIAN WAYFINDING
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
MessageMessage
Lot XXAddress
4"6"
4"
1'-4
"2'-0"- graphic panel
3/4"
1'-9 1/2" 3 1/4"
See PDR12, Configuration 1 forsign components, details
and graphic layouts.
See PDR11, Configuration 1 forsign components, details
and graphic layouts.
2" m
in.
2'-3
"3'
-2"
5'-5
"
1/8"
4" 4'-1 3/4" 4"
4'-9 3/4"
aligns to top of panel
aligns to bottomof panel
grade line
A
BD
CG
C
C
BA
F
E
PDR243/4” = 1’-0”
Plan Elevation-Single side Sign(double side panels shown dashed)
PDR241/2” = 1’-0”
GI
GH
See PDR11Configuration 1for sign components, details and graphic layouts.
2E.68
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post
cap, mechanically fastened
w/ tamper-resistant, span-
ner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
PDR24DIRECTIONAL WITH MAP
This Page Intentionally Left Blank
2E.69
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
F FP_S 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
G Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
H Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
SECTION E: PEDESTRIAN WAYFINDING
PDR24DIRECTIONAL WITH MAP
1/8"7/8"
1/8"
1 1/8"
1/4"
pan
el e
xtru
sio
n v
arie
s-se
e el
evat
ion
s fo
r h
eig
ht
dim
ensi
on
s
1/4"
pan
el h
eig
ht
vari
es-
see
elev
atio
ns
for
hei
gh
t d
imen
sio
ns
be
co
me
ssi
gn
pa
ne
l
Component Parts /Assembly
Finished Sign
Panel Detail no scale
CL
M
A
M
B
C
D
E
N
M
N
G
2E.70
DETAIL
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR24
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
DIRECTIONAL WITH MAP
PDRPedestrian
Directional-see various
layouts,sheet 3.17.
4" a
bov
e fi
nis
hed
gra
de
2'-0"- graphic panel
3/4" 1 3/4" 3/4"
3 1/4"
7/8"
4 1/
4"7/
8"
6"
1/8"
typ
.
1/8"typ
2"
Partial Horizontal Section 3” = 1’-0”
Vertical Section: Concrete Footerno scale
Plan Elevation at Sidewalkno scale
C
L
M
g
grade line grade line
B
I
J
H
K
B
C
H
I
J
at concrete sidewalk condition
Vertical Section: Concrete Footerno scale
at earth / grass condition
2E.71
DETAIL
Specifications
SECTION E: PEDESTRIAN WAYFINDING
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR24
H Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
I Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
J Expansion Joint To accommodate concrete
expansion and contraction.
K Sand Compacted sand for con-
densation drainage per
engineering requirements.
L Attachment Bracket Rutgers owned custom ex-
truded bracket cut to match
height of aluminum plate.
Permanently mount to back
of plate.
*See post extrusion spec. information on Parts sheet.
M Sign Panel Plate 1/8” Thk. aluminum plate cut
to dimensions shown
in elevations.
DIRECTIONAL WITH MAP
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
a
PNL21” = 1’-0”
2E.72
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.72
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
GRAPHIC LAYOUTS
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
GRAPHIC FOR
PLACEMENT ONLY
DIRECTIONAL WITH MAP
PDR24
Lot XX
Lot XX
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
MessageMessage
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental SchLot XX
Lot XX
Lot XX
Address
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
Configuration 1 Configuration 2
26"
a
C
D
B
E
F
E
G Structural attachment angle (not shown)
Full length filler panels are used for single sided signs only. (not shown)
Stop panel below grade line. (not shown)
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR25
* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.
For specification and ordering purposes, contact EMS Delaware;
231 Executive Drive Suite 11
Newark, DE 19702 USA
Toll Free: 800-863-1496
Local Phone: 302-391-1370
Fax: 302-391-1371
Website: www.EasternMetal.com
Email: [email protected]
CONFIGURATIONS
Helpful Hints
• Keep in mind the intuitive path of
the user when locating and spec-
ifying exterior directional signs.
• Use only standard and
approved nomenclature
and abbreviations.
• Refer to all appropriate state
and local codes, as needed, for
sign compliance, including, but
not limited to zoning, ADAAG,
MUTCD, etc.
• Sign fabricator to provide
all relevant engineering calcu-
lations and provide all methods
and materials of construction in
shop drawings
Guidelines
• Provide pedestrians with sequential
guidance throughout the campus
with strategic placement and
programmed messaging.
• Reinforce the brand equity in the
built environment with brand color
on the header.
• Use as a single-sided or
double-sided sign. Message
standards apply to both sides
of sign. It is acceptable to use
a different configuration on
each side.
• Locate signs at key decision points
and at locations of optimal line of
sight from public buildings and
campus core.
• Arrow order should be as follows:
Up (straight), Left, Right.
• Do not rearrange panel order.
• Map orientation to match view of
pedestrian when standing at the
sign. What is shown ahead of you
on the map should appear ahead
of you.
• Contact Rutgers University
Environmental Graphics
Coordinator and or Department
of Facilities, Planning and
Development for correct
map artwork.
PART COUNTSPART COUNTS
POST CAP POST CAP
SIGN POST SIGN POST
PNL.1 PNL.1
FP_1 FP_1
PNL.2 PNL.3
PNL.5 PNL.5
FP_6 FP_6
FP_7 FP_7
FP_S FP_S
2 2
2 2
1 1
6 6
1 1
1 1
2 2
2 2
4 4
2 2
2 2
2 2
10 10
2 2
2 2
4 4
0 0
4 4
CONFIGURATION 1: CONFIGURATION 2:
SINGLE SIDED
SINGLE SIDED
DOUBLE SIDED
DOUBLE SIDED
A A
B B
C C
D D
E E
G G
H H
I I
J J
* *
PARTS
DIRECTIONAL WITH MAP
2E.73
Questions? Please contact xxxxx
?
SECTION E: PEDESTRIAN WAYFINDING
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental SchLot XX
Lot XX
Lot XX
Address
Address
Address
MessageMessage
MessageMessage
MessageMessageMessage
4"6"
4"
1'-4
"2'-0"- graphic panel
3/4"
1'-9 1/2" 3 1/4"
See PDR11, Configuration 1 forsign components, details
and graphic layouts.
4" 4'-1 3/4" 4"
4'-9 3/4"
2" m
in.
2'-2
"3'
-3"
5'-5
"
1/8"
aligns to top of panel
aligns to bottomof panel
See PDR11, Configuration 1 forsign components, details
and graphic layouts.
CG
C
BA
E
PDR23: Configuration 1 3/4” = 1’-0”
Plan Elevation-Single side Sign(double side panels shown dashed)
PDR23z: Configuration 1, 21/2” = 1’-0”
GH
grade line
A
BD
C
F
GI
See PDR11Configuration 1for sign components, details and graphic layouts.
2E.74
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
EFP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
DIRECTIONAL WITH MAP
PDR25
This Page Intentionally Left Blank
2E.75
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
F FP_S 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
G Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
H Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
SECTION E: PEDESTRIAN WAYFINDING
PDR25DIRECTIONAL WITH MAP
1/8"7/8"
1/8"
1 1/8"
1/4"
pan
el e
xtru
sio
n v
arie
s-se
e el
evat
ion
s fo
r h
eig
ht
dim
ensi
on
s
1/4"
pan
el h
eig
ht
vari
es-
see
elev
atio
ns
for
hei
gh
t d
imen
sio
ns
be
co
me
ssi
gn
pa
ne
l
Component Parts /Assembly
Finished Sign
Panel Detail no scale
CL
M
A
M
B
C
D
E
N
M
N
G
2E.76
DETAIL
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR25
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4
*Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
DIRECTIONAL WITH MAP
PDRPedestrian
Directional-see various
layouts,sheet 3.17.
4" a
bov
e fi
nis
hed
gra
de
2'-0"- graphic panel
3/4" 1 3/4" 3/4"
3 1/4"
7/8"
4 1/
4"7/
8"
6"
1/8"
typ
.
1/8"typ
2"
Partial Horizontal Section 3” = 1’-0”
Vertical Section: Concrete Footerno scale
Plan Elevation at Sidewalkno scale
C
L
M
g
grade line grade line
B
I
J
H
K
B
C
H
I
J
at concrete sidewalk condition
Vertical Section: Concrete Footerno scale
at earth / grass condition
2E.77
DETAIL
Specifications
SECTION E: PEDESTRIAN WAYFINDING
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
PDR25
H Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
I Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
J Expansion Joint To accommodate concrete
expansion and contraction.
K Sand Compacted sand for con-
densation drainage per
engineering requirements.
L Attachment Bracket Rutgers owned custom ex-
truded bracket cut to match
height of aluminum plate.
Permanently mount to back
of plate.
*See post extrusion spec. information on Parts sheet.
M Sign Panel Plate 1/8” Thk. aluminum plate
cut to dimensions shown in
elevations.
DIRECTIONAL WITH MAP
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
PNL.31” = 1’-0”
a
2E.78
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.78
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4. *Use one panel only for single sided sign.
GRAPHIC LAYOUTS
GRAPHIC FOR
PLACEMENT ONLY
PDR25DIRECTIONAL WITH MAP
This Page Intentionally Left Blank
2E.79
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
2E.79
GRAPHIC DONT’S
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
SECTION E: PEDESTRIAN WAYFINDING
PDR25DIRECTIONAL WITH MAP
This Page Intentionally Left Blank
2E.80 RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
SECTION E:
ORT10 SERIES
SUB-SECTION
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.82
ORT10 Series – Orientation Map
ORT11
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
ORT10 Series Overview
Recommended sign type
configurations shown.
Additional module
configurations must be
approved by Rutgers
University Environmental
Graphics Coordinator &
or Department of Facilities,
Planning and Development.
Below are the following steps for
selecting the correct vehicular
directional for your needs.
A. Verify “heads up” map
orientation and artwork per sign
placement.
.
Sign Selection Process
Questions? Please contact xxxxx
?
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
26"
a
C
D
G
B
E
I
H
Full length filler panels are used for single sided signs only. (not shown)
Stop panel below grade line. (not shown)
Configuration 1
* The custom sign post extrusion is Rutgers owned and must be used. No substitutions allowed.
For specification and ordering purposes, contact EMS Delaware;
231 Executive Drive Suite 11
Newark, DE 19702 USA
Toll Free: 800-863-1496
Local Phone: 302-391-1370
Fax: 302-391-1371
Website: www.EasternMetal.com
Email: [email protected]
2E.83
PARTS
CONFIGURATIONS
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
POST CAP
SIGN POST
DR_PNL.x
FP_1
DR_PNL.x
DR_PNL.x
FP_x
FP_x
FP_S
2
2
1
4
1
1
2
2
4
2
2
2
8
2
2
4
0
4
PART COUNTS
SINGLE SIDED
DOUBLE SIDED
A
B
C
D
E
F
G
I
J
*
SECTION E: PEDESTRIAN WAYFINDING
CONFIGURATION 1: CONFIGURATION 2:
ORIENTATION MAP
ORT11
Helpful Hints
• Keep in mind the intuitive
path of the user when locat-
ing and specifying exterior
directional signs.
• Use only standard and
approved nomenclature
and abbreviations.
• Refer to all appropriate state
and local codes, as needed,
for sign compliance, includ-
ing, but not limited to zon-
ing, ADAAG, MUTCD, etc.
• Sign fabricator to provide
all relevant engineering
calculations and provide all
methods and materials
of construction in
shop drawings.
Guidelines
• Provide pedestrians with a
visual guide of the campus.
• Reinforce the brand equity
in the built environment with
brand color on the header.
• Use as a single-sided or
double-sided sign. Message
standards apply to both
sides of sign.
• Map “heads up” orientation
to match view of pedestrian
when standing at the sign.
What is shown ahead of you
on the map should appear
ahead of you.
• Contact Rutgers
University Environmental
Graphics Coordinator and
or Department of Facilities,
Planning and Development
for correct map artwork.
Questions? Please contact xxxxx
?
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
1/8"
4"1"
3'-3
"2'
-2"
2" m
in.
5'-1
0"
eq.
6"eq
.
1'-4
"
3/4"2'-0"- graphic panel
3/4"
3 1/4" 1'-7" 3 1/4"
eq. 2'-1 1/2" eq.
2'-9 1/2"
A
CD
E
E
GBA
G
ORT113/4” = 1’-0”
Plan Elevation-Single side Sign(double side panels shown dashed)
ORT11: Configuration 1, 21/2” = 1’-0”
Back Elevation- Single side Sign(panel configurationvaries, 1 shown)
IJ
grade line
BF
E
H
IJ
2E.84
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post
cap, mechanically fastened
w/ tamper-resistant, span-
ner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.2 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
F FP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
ORIENTATION MAP
ORT11
This Page Intentionally Left Blank
2E.85
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
G FP_3 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1. *Use only for single sided signs.
H FP_S 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
I Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and
appropriate wind-loads for
individual structure. Footer
to be below grade and
landscaping, by others,
where necessary.
J Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
SECTION E: PEDESTRIAN WAYFINDING
ORT11ORIENTATION MAP
becomessign panel
Component Parts /Assembly
Finished Sign
C
A
M
D
B
E
F
G
N
M
N
2E.86
DETAIL
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
A Post Cap 1/8” thk. Pre-punched and
painted aluminum post cap,
mechanically fastened w/
tamper-resistant,
spanner-head screws.
Paint all sides: P4.
B Sign Post Rutgers owned custom,
extruded sign post w/inset
grooves for ease of panel
install and removal.
Paint all sides: P4. All drilled holes to be weath-
er-proofed for water and
environmental considerations.
*See post extrusion spec. information on Parts sheet.
C PNL.1 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P1. *Use one panel only for single sided sign.
D FP_1 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
E PNL.2 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P2.
*Use one panel only for single sided sign.
FFP_2 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1.
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
ORT11ORIENTATION MAP
3'-2" panel length
3/4" 1 3/4" 3/4"
3 1/4"
1/8"typ.
2"
1/8"
typ
.
7/8"
4 1/
4"7/
8"
6"
1/8"7/8"
1/8"
1 1/8"
1/4"
pan
el e
xtru
sio
n v
arie
s-se
e el
evat
ion
s fo
r h
eig
ht
dim
ensi
on
s
1/4"
pan
el h
eig
ht
vari
es-
see
elev
atio
ns
for
hei
gh
t d
imen
sio
ns
4" a
bov
e fi
nis
hed
gra
de
Partial Horizontal Section 6” = 1’-0”
Vertical Section: Concrete Footerno scale
Plan Elevation at Sidewalkno scale
Panel Detail no scale
E
E
G
B
n
m
m
n
grade line grade line
B
j
k
l
i
i
j
k
at concrete sidewalk condition
Vertical Section: Concrete Footerno scale
at earth / grass condition
2E.87
DETAIL
Specifications
SECTION E: PEDESTRIAN WAYFINDING
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
G FP_7 1/8” thk. Painted aluminum
filler panel.
Paint all sides: P1. *Use only for single sided signs.
I Concrete Footer / Pad Minimum 3’-0”d. concrete
footer. Each footer to
conform to engineering
requirements and appropri-
ate wind-loads for individual
structure. Footer to be Be-
low grade and landscaping,
by others, where necessary.
J Concrete Sidewalk If sign is located at sidewalk,
remove sidewalk square,
pour footer below sidewalk
and repour sidewalk square.
K Expansion Joint To accommodate concrete
expansion and contraction.
L Sand Compacted sand for con-
densation drainage per
engineering requirements.
M Attachment Bracket Rutgers owned custom ex-
truded bracket cut to match
height of aluminum plate.
Permanently mount to back
of plate.
*See post extrusion spec. information on Parts sheet.
N Sign Panel Plate 1/8” Thk. aluminum plate cut
to dimensions shown
in elevations.
ORT11ORIENTATION MAP
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
Ambulatory Care CenterDoctors Office CenterStone CenterUniversity HospitalNJ Dental School
Ambulatory CarDoctors OfficStone CenteUniversity HospNJ Dental Sch
PNL.31” = 1’-0”
a
2E.88
ELEVATION
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
Specifications
RUTGERS UNIVERSITY UNIVERSITYWIDE WAYFINDING AND SIGNAGE STANDARDS MANUAL2E.88
PARTS
ELEVATION
DETAIL
GRAPHIC LAYOUT
GRAPHIC LAYOUTS
For typography, finish/material and symbol specifications
refer to Manual Part 2, Section A: Graphic Standards.
A PNL.3 Painted aluminum panel w/
applied vinyl graphics. Cus-
tom extruded panel attach-
ment to be mounted to back
of panel w/ hi-bond adhesive.
Paint all sides: P4.
GRAPHIC FOR
PLACEMENT ONLY
ORT11ORIENTATION MAP