See clearly. Treat optimally.
Peripheral Vascular
Intravascular ultrasound
Peripheral
Visions PV .035 OTW• Includes centimeter markers
• 0.038" maximum guide wire compatible
• 60 mm max imaging diameter
• 90 cm working length
Visions PV .014P RX• 0.014" guide wire compatible
• 20 mm max imaging diameter
• 150 cm working length
A full line of IVUS catheters to help guide your treatment strategiesOur peripheral imaging catheters help assess the location of the disease and lesion morphology, including calcium and thrombus. IVUS can also be used to appropriately size stents and confirm completeness of treatment.
Reconnaissance PV .018 OTW• 0.014" and 0.018" guide wire compatible
• 20 mm max imaging diameter
• 150 cm working length
Visions PV .018 RX• 0.014" and 0.018" guide wire compatible
• 24 mm max imaging diameter
• 135 cm working length
Pioneer Plus re-entry• 0.014" guide wire compatible
• 20 mm max imaging diameter
• 120 cm working length
Assessing and delivering the right therapy at the right time for the right patient is imperative to improving outcomes. Clinicians need technology that’s diverse and adaptable in order to deliver with optimal precision and efficacy.
PV .018 RX (Arterial)
PV .014P RX (Arterial)
PV .014P RX, PV .018 RX, PV .035 OTW (AV access)
PV .035 OTW (Venous)
PV .035 OTW (Aortic)
Diagnose and treat peripheral vascular disease
Choose your catheter based on imaging diameter and wire compatibility needed.
IVUS allows assessment of the following:
• % Stenosis
• Calcium and thrombus
• Real time vessel diameter and lesion morphology
• Length of stenosis
• Dissection
• Position of wire in true or false lumen
• Location of side branches (without using contrast)
• Venous compression
• Completeness of treatment
PV .018 OTW (Arterial)
Please note, this diagram is intended to demonstrate the most commonly used IVUS catheters per procedure type.
All Philips PV IVUS catheters is designed for the evaluation of peripheral vasculature.
©2020 Koninklijke Philips N.V. All rights reserved. Approved for external distribution. D041655-01 092020
Philips3721 Valley Centre Drive, Suite 500San Diego, CA 92130 USAwww.philips.com/IGTdevices
Ordering information and technical specifications
PIM connector
Shaft markers Guide wire exit port≤ 0.018" (0.46 mm)
Transducer 3.5 F Tip O.D. 0.030"
135 cm
3.4 F
95 cm
31 cm
PIM connector
Brachial and femoralshaft markers
Guide wire exit port≤ 0.014" (0.36 mm)
Transducer3.5 F
Tapered tipO.D. 0.019"
150 cm
3.3 F
100 cm
24 cm GlyDx hydrophilic coating
Needle depth markers
Needle stop ring with lock
Needle deployment with autolock ring
Needle guide wire lumen
Connector for IVUS console
HandleExtended nitinol needle
IVUS tranducer
PIM connector
Y-connectorTransducer 8.2 F
Tip O.D. ≤0.055"
90 cm working length
Guide wire exit port≤ 0.038" (0.97 mm)
30 cm GlyDx hydrophilic coating
25 RO markers 1 cm apart
1 cm 1 cm 1 cm
1 mm5 mm
12 mm
1.5 mm imaging plane
1 cm1 cm
6.5 mm1.5 mm
PIM connector
Y-connectorTransducer 3.5 F
Tip O.D. ≤0.032”
150 cm working length
Guide wire exit port≤ 0.018" (0.46 mm)
40 cm GlyDx hydrophilic coating
Visions PV .035 OTWMinimum sheath 8.5 F 88901
Reconnaissance PV .018 OTWMinimum sheath 5 F 018OTW
Visions PV .018 RX Minimum sheath 6 F 86700
Visions PV .014P RXMinimum sheath 5 F 014R
Pioneer Plus re-entryMinimum sheath 6 F PPLUS120