seismic attenuation system (sas) for lcgt inverted pendulum: 30mhz 3 cascaded gas filter: 500mhz...
TRANSCRIPT
![Page 1: Seismic Attenuation System (SAS) for LCGT Inverted pendulum: 30mHz 3 cascaded GAS filter: 500mHz Test mass suspension: triple pendulum Transfer functions](https://reader035.vdocument.in/reader035/viewer/2022062323/56649efa5503460f94c0bf11/html5/thumbnails/1.jpg)
Seismic Attenuation System (SAS) for LCGT
Inverted pendulum: 30mHz3 cascaded GAS filter: 500mHzTest mass suspension: triple pendulum
Transfer functions computedwith a rigid body model-20dB @100mHz
V-H coupling dominant @10HzSafety margin of over 50
![Page 2: Seismic Attenuation System (SAS) for LCGT Inverted pendulum: 30mHz 3 cascaded GAS filter: 500mHz Test mass suspension: triple pendulum Transfer functions](https://reader035.vdocument.in/reader035/viewer/2022062323/56649efa5503460f94c0bf11/html5/thumbnails/2.jpg)
Seismic Attenuation System (SAS) for LCGTSAS ControlActive Damping of Mechanical Resonances Digital Servo using Commercial Control SystemSensors 3 Horizontal Accelerometers (ACC) 3 Horizontal LVDTs 1 Vertical LVDTActuators 3 Horizontal Magnet-Coil Actuators 1 Vertical Magnet-Coil Actuator
ACC
LVDTActuator
![Page 3: Seismic Attenuation System (SAS) for LCGT Inverted pendulum: 30mHz 3 cascaded GAS filter: 500mHz Test mass suspension: triple pendulum Transfer functions](https://reader035.vdocument.in/reader035/viewer/2022062323/56649efa5503460f94c0bf11/html5/thumbnails/3.jpg)
Seismic Attenuation System (SAS) for LCGT
History of SAS R&DInternational collaboration with Caltech and Univ. of Pisa•Started TAMA-SAS study in 2000•R&D of IP and MGAS filter at Caltech by 2001•R&D using SAS prototype at Univ. of Tokyo by 2003•Started manufacturing of SAS for TAMA300 in 2003•Installation of SAS into TAMA300 in 2005
R&D at Caltech
Schedule of TAMA-SAS installation
![Page 4: Seismic Attenuation System (SAS) for LCGT Inverted pendulum: 30mHz 3 cascaded GAS filter: 500mHz Test mass suspension: triple pendulum Transfer functions](https://reader035.vdocument.in/reader035/viewer/2022062323/56649efa5503460f94c0bf11/html5/thumbnails/4.jpg)
Seismic Attenuation System (SAS) for LCGT
R&D using 3m FP prototype Isolation of 10-11m/Hz1/2@4Hz RMS velocity of 0.3m/s
SAS prototype in the 3m Fabry-Perot cavity
![Page 5: Seismic Attenuation System (SAS) for LCGT Inverted pendulum: 30mHz 3 cascaded GAS filter: 500mHz Test mass suspension: triple pendulum Transfer functions](https://reader035.vdocument.in/reader035/viewer/2022062323/56649efa5503460f94c0bf11/html5/thumbnails/5.jpg)
Seismic Attenuation System (SAS) for LCGT
Test in TAMA300 To 4 Test Masses Installation: 2005 Observation: 2006
SAS for TAMA300