Introduction
Adding Visualization to Your Control System
As a machine builder or end user, you design control solutions with an eye toward improving safety, higher levels of performance and efficiency, and better integration with the rest of the manufacturing operation. To achieve these goals, you need a scalable, modular control system that offers safety, throughput and information management capabilities to match each application’s requirements.
The Rockwell Automation® Integrated Architecture™ system is unique in that it offers scalable, integrated safety, motion control, and visualization capabilities that are ideal for machine builders and end users who want a single control and development environment, regardless of the application size or complexity.
The visualization products comprise a suite of scalable HMI software and operator interface hardware that provide plant floor machine operators, supervisors, engineers, and business managers a window to critical data, and production and process information. And all this can be done from the plant floor or remotely from a web browser.
Whether it’s a machine-level or site-level HMI, a Windows CE platform, a smaller component HMI, or an industrial computer, Rockwell Automation has a portfolio of visualization solutions to match your system requirements.
PanelView™ Plus terminals, FactoryTalk® View Machine Edition, and FactoryTalk View Site Edition provide premier integration in a number of ways.
• Reduce programming time with Logix native addressing and the ability to browse directly to Logix tags without creating a separate database.
• Simplifies interaction of all networks with support for all Core Integrated Architecture CIP networks including EtherNet/IP, ControlNet, and numerous other drivers.
• Simplifies development time with pre-engineered, pre-tested faceplates for specific motion, drives, and process applications.
4 Rockwell Automation Publication VIEW-SG001G-EN-P - August 2011
Visualization Platforms
Visualization Platforms
PanelView Plus Family PanelView Component Family
page 26page 7
Select an Operator Interface
Do you need:• Machine-level HMI with
FactoryTalk View ME?• Dedicated platform?• Component level HMI?
Yes
No
Machine-level HMI
Do you need a machine-level HMI?• Small to large applications• FactoryTalk View ME software • ControlLogix® or CompactLogix™
controllers
Do you need a component-level HMI?:• Small applications• Web-based software• MicroLogix™, SLC™, Micro800™
controllers or device
Select a PanelView ComponentConsider:• Display size• Monochrome or color display• Operator input• Communication• With or without battery backup
Select a PanelView PlusConsider:• Windows CE desktop access• Remote access and file viewers• Display size• Operator input• Power requirements• Communication• Environmental requirements
Select• Accessories• Cables
Select• FactoryTalk View ME software• Optional communication module• Accessories• Cables
For technical specifications, certifications, and environmental specifications on the PanelView Plus terminals, refer to the PanelView Plus Specifications Technical Data, publication 2711P-TD005
For technical specifications, certifications, and environmental specifications on the PanelView Component terminals, refer to the PanelView Component Specifications Technical Data, publication 2711C-TD001
Rockwell Automation Publication VIEW-SG001G-EN-P - August 2011 5
Visualization Platforms
Industrial MonitorsIntegrated Display Computers Non-display Computers
Select• Accessories
Performance page 45
Standard page 45
Non-displaypage 40
Compact Non-displaypage 43
Integrated Displaypage 32
Display with Keypadpage 37
Select an Industrial Computer
Do you need:• Site-level HMI with
FactoryTalk View SE?• Open platform?• Processing power of an
industrial computer?
Yes
Hazardous Location Computers
Select• FactoryTalk View software if needed• Accessories
Hazardous Locationpage 39
Select• FactoryTalk View software if needed• Accessories
Site-level HMI
HMI Servers
FactoryTalkData Server
Data Servers
Do you need:• Integrated display?• Integrated display with keypad?• Rockwell Software® and
third-party software?
• Extended temperature range?• Class 1 Div 2 and ATEX certification?• Rockwell Software and
third-party software?
Do you need:• Computer without a display?• Compact form factor option?• Rockwell Software and
third-party software?
Do you need:• Monitor only?• Class 1 Div 2 certification?• Standard industrial environment?
Select a Display ComputerConsider:• Display size and input method• Resistive touch screen• Solid-state or hard-disk drive• Standard or performance options• Operating system• Power requirements• Bezel type
Select Hazardous Location Computer
Consider:• Computer with display• Computer without display
Select a Non-display ComputerConsider:• Environmental requirements• Compact form factor• Solid-state or hard-disk drive• Power requirements• Operating system• Mounting method• Standard or performance options
Select a MonitorConsider:• Environment• Display size • Touch screen option• Bezel type• Mounting method
Select• FactoryTalk View Software if needed• Accessories
For technical specifications, certifications, and environmental specifications on the industrial computers and monitors, refer to the Industrial Computers and Monitors Specifications Technical Data, publication IC-TD001.
Do you need:
Rockwell Automation Publication VIEW-SG001G-EN-P - August 2011 6
HMI Terminal Comparison
HMI Terminal Comparison This table provides a quick glance at comparisons between the different HMI terminal platforms.
Table 1 - HMI Terminal Comparison
Characteristic 2711P PanelView Plus 6700, 1000, 1250, 1500
2711P PanelView Plus 400, 600
2711P PanelView Plus Compact 400, 600, 1000
2711C PanelView ComponentC200, C300, C600, C1000
Display 700: 6.5 in. color TFT1000: 10.4 inch color TFT1250: 12.1 in. color TFT1500: 15 in. color TFT
400: 3.5 in. color TFT400: 3.8 in. grayscale600: 5.5 in. color TFT600: 5.5 in. grayscale TFT
400: 3.5 in. color TFT400: 3.8 in. grayscale600: 5.5 in. color TFT100: 10.4 in. color TFT
C200: 2 in. monoC300: 3 in. monoC600: 5.7 in. color TFT or monoC1000: 10.4 in. color TFT
Input type All models: keypadAll models: touch screenAll models: key/touch
400: key/touch (3.5 in.)400: keypad (3.8 in.)600: touch screen
400: key/touch (3.5 in.)400: keypad (3.8 in.)600/1000: touch screen
C200: 4-keys C200: 10-keys+numeric C300: 10-keys/+numeric C600/C1000: touch screen
Built-in communication ports
RS-232EtherNet2 USB host and 1 USB device
RS-232EtherNet1 USB
RS-232EtherNet1 USB: 400/6002 USB: 1000
RS-232RS-422/RS-4851 USB host and 1 USB deviceEtherNet: C600/C1000C only
Add-on communication module
DH+DH-485ControlNet
DH+DH-485ControlNet
None None
Serial communication RS-232: DF1 or DH-485 RS-232: DF1 or DH-485 RS-232: DF1 or DH-485 RS-232: DF1, DH-485, multivendor options, RS-485
Programming software FactoryTalk View ME 6.0 or laterViewPoint web server 1.2 or later
FactoryTalk View ME 5.1 or earlier FactoryTalk View ME 5.1 or later DesignStation 2.0 or laterWeb-enabled softwareresident in terminalPC-based emulator available
Operating system Windows CE 6.0 operating systemsupports this features:• FTP Server• VNC client/server• PDF reader• Active X controls• Third-party device support
Additional functionality is available by ordering terminals with optional extended features(1)
• Internet Explorer web browser• Remote desktop connection• Media player• File viewers for Microsoft Office
Word, PowerPoint, and Excel• WordPad text editor
None None None
Open or closed system Open or closed desktop Closed Closed Closed
Memory 512 MB nonvolatile flash/512 MB RAM 64 MB nonvolatile flash/64 MB RAM 64 MB nonvolatile flash/64 MB RAM 64 MB nonvolatile flash/64 MB RAM
External storage Secure Digital (SD) cardUSB flash drives
CompactFlash CompactFlash USB flash: C200/C300USB flash/SD card: C600/C1000
Power AC or DC AC or DC DC DC
Preferred controller ControlLogix CompactLogix CompactLogix MicroLogix, SLC, PowerFlex 4 drive, Micro800
Capabilities • High memory capacity• desktop access enabled or disabled• backup and restore function• Multi-network/multivendor
connectivity• Alarm messages (email alarms)• Recipes• Trending • Data logging
• Multi-network/multivendor connectivity
• Alarm messages• Recipes• Trending • Data logging
• Single controller• 25 displays• 200 alarm messages• Recipes• Trending• Data logging
• Single device• <20 displays• <100 alarm messages• Recipe upload/download• Trending • Data logging
Key differentiators • Windows CE desktop access• Larger application size• Pre-engineered faceplates for
motion, process, and drives• Native Logix addressing• Direct referencing of Logix tags• Modular hardware simplifies
system integration and updates• FactoryTalk View Machine Edition
comes installed and activated
• Pre-engineered faceplates for motion, process, and drives
• Native Logix addressing• Direct referencing of Logix tags• Modular hardware simplifies
system integration and updates• FactoryTalk View Machine Edition
comes installed and activated
• Single controller for midrange applications
• Pre-engineered faceplates for motion, process, and drives
• Native Logix addressing• Direct referencing of Logix tags• FactoryTalk View Machine Edition
comes installed and activated
• Component-level device for small applications
• No programming software required
(1) Extended features are available by ordering catalog numbers ending in 9, for example, 2711P-Kxxxx9, 2711P-Bxxxx9, 2711P-Txxxx9.
Rockwell Automation Publication VIEW-SG001G-EN-P - August 2011 7
PanelView Plus Terminals
PanelView Plus Terminals PanelView Plus devices give operators a clear view into monitoring and controlling applications. With FactoryTalk View Machine Edition already installed and activated, development time is reduced. The PanelView Plus family of products provides a broad range of rugged terminals that offer the following:
• Premier integration with the Integrated Architecture platform• Real-time monitoring of a terminal’s displays from a web browser• Common development software• Scalable 4 to 15-inch displays with a touch screen, keypad, or both
Figure 1 - Selecting a PanelView Plus Platform
• Internet Explorer• Remote desktop connection• Microsoft Office file viewers• WordPad text editor• Media player (MPEG)
PanelView Plus 6 Terminals with extended features
See page 10
PanelView Plus 400 and 600 Terminals
See page 16
PanelView Plus Compact Terminals
See page 19
• > 6-inch display• Access to CE desktop• Web browser/file viewers• Remote access• PDF reader• Multiple apps
Do you need any of these?
Yes
No
Yes
• Multiple controllers?
• > 25 displays
• > 200 alarms
• < 6-inch display?
Yes
No
For complete technical specifications, certifications, and environmental specifications on the PanelView Plus terminals, refer to the PanelView Plus Specifications Technical Data, publication 2711P-TD005
Do you need any of these?
No
Do you need any of these?
Cat. No. 2711P-xxxx9 or 2711P-RP9x
Cat. No. 2711P-xxxx8 or 2711P-RP8x
PanelView Plus 6 Terminals without extended features
See page 10
8 Rockwell Automation Publication VIEW-SG001G-EN-P - August 2011
PanelView Plus Terminals
Typical Configurations Figure 2 shows a configuration where a PanelView Plus terminal is used with a Logix controller in standalone or machine-level mode using serial connectivity.
Figure 2 - Standalone Machine
In Figure 3, a PanelView Plus Compact terminal and the 1769-L3x CompactLogix system provide an integrated solution for midsize applications. Typically, these applications are machine-level control applications that require smaller I/O quantities and more communication capabilities than serial connectivity.
Figure 3 - Midsize Application
To Business Systems
Rockwell Automation Publication VIEW-SG001G-EN-P - August 2011 9
PanelView Plus Terminals
In Figure 4, a PanelView Plus 6 terminal communicates with all devices by using EtherNet/IP communication. A Logix controller along with a Kinetix® 300 servo drive offer a scalable power platform cost-sensitive applications, such as simple packaging machinery, indexing tables, automatic assembly equipment, tool changing machinery, and feed and withdrawal equipment.
Figure 4 - Indexing Motion
To Business Systems
26 Rockwell Automation Publication VIEW-SG001G-EN-P - August 2011
PanelView Component Terminals
PanelView Component Terminals
This component level operator interface provides a control and visualization solution for low-level applications by using serial or Ethernet communication. Preferred controllers are the Micrologix, SLC, and Micro800™ controllers plus you can connect directly to component devices such as the PowerFlex 4® drives.
This platform offers a full line of 2- to 10-inch displays with touch or function key input. Plus, the integrated mounting clips on the terminal simplifies panel installation and maintenance. Other key features include the following:
• Design software resident in the terminal means no additional software to install on your computer.
• Secured programming access protects applications from unauthorized modifications.
• Unicode language switching in languages such as Russian, Greek, Chinese, Japanese, and Korean.
• Alarm messages with embedded variables and history. • Recipe capability lets you upload and download groups of data or
parameter settings.
For complete technical specifications, certifications, and environmental specifications on the PanelView Component terminals, refer to the PanelView Component Specifications Technical Data, publication 2711C-TD001.
Software
The built-in programming software is accessed from a web browser over a USB or Ethernet connection. This means you can design your application and adjust terminal settings while viewing the results directly on the connected terminal. For those times when a PanelView Component terminal is not available, you can still create an application by using the free emulator or DesignStation, version 2.0 or later.
Typical Configuration
A PanelView Component terminal is typically connected to a MicroLogix controller or another component, such as a PowerFlex 4 drive, over an Ethernet or serial connection.
Ethernet or Serial Connection
Rockwell Automation Publication VIEW-SG001G-EN-P - August 2011 27
PanelView Component Terminals
Product Selections
Product Accessories
Tables 45…48 list accessories for the PanelView Component terminals.
BulletinNumber Input Type Display Size Display Type
| | |
2711C- F = Function keys 2 = 2 in. C = Color
K= Keypad and function keys 3 = 3 in. M = Grayscale
T = Touch screen 6 = 6 in. T = TFT Color
10 = 10 in.
Table 44 - PanelView Component Terminals
Cat. NoDisplay
Input TypeCommunication
Power Size Type Serial(1) Ethernet
C200 Model
2711C-F2M2-in. Monochrome STN display
4 function keys • – 24V DC
2711C-K2M 10 function keys and numeric keypad • – 24V DC
C300 Model
2711C-T3M3-in. Monochrome FSTN display
Touch screen • – 24V DC
2711C-K3M 10 function keys and numeric keypad • – 24V DC
C600 Model
2711C-T6M 6 in. Monochrome FSTN display Touch screen • • 24V DC
2711C-T6T Color TFT display Touch screen • • 24V DC
C1000 Model
2711C-T10C 10 in. Color TFT display Touch screen • • 24V DC
(1) Serial refers to RS-232 (DF1), RS-232 (DH-485), RS-485 communication.
Table 45 - Antiglare Overlays
Cat. No.(1)
(1) Three overlays are shipped with each catalog number.
PanelView Component Model
Input Type
Function Key Numeric Keypad Touch
2711C-RG2F C200 •
C300 •
2711C-RG2K C200 •
C300 •
2711C-RG6T C600 •
2711C-RG10T C1000 •
28 Rockwell Automation Publication VIEW-SG001G-EN-P - August 2011
PanelView Component Terminals
Communication Cables
This table summarizes cables used by the PanelView Component terminals.
Table 46 - Memory Cards
Cat. No. Description
2711C-RCSD USB to Secure Digital (SD) adapter for SD card
Table 47 - Power Terminal Blocks
Cat. No. Description Quantity
2711C-RJ422 RS-422/RS-485 connector with resistor 10
2711-TBDC DC power terminal block 10
Table 48 - Power Supply
Cat. No. Description Quantity
2711P-RSACDIN DIN-rail mount AC-to-DC power supply, 85…265V AC, 47…63 Hz 1
Table 49 - Cables and Adapters
Cat. No. Description Connectors Length
2711C-CBL-UU02 USB host to USB device programming cable. 2 m (6.5 ft)
2711C-CBL-AB03 RS-485 (5-pin) to RJ45 operating/programming cable for connecting PanelView Component terminals to SLC 5/01, 5/02, 5/03 controllers.
RS-485 (5-pin) to RJ45
1747-CP3 Operating/programming cable for connecting PanelView Component terminals to SLC and MicroLogix controllers.
9-pin D-shell to 9-pin D-shell null modem cable
3 m (10 ft)
1761-CBL-PM02 RS-232 operating/programming cable for connecting PanelView Component terminals to MicroLogix controllers.
9-pin D-shell to 8-pin mini DIN 2 m (6.5 ft)
2711-CBL-PM05 RS-232 operating/programming cable for connecting PanelView Component terminals to MicroLogix controllers. 9-pin D-shell to 8-pin mini DIN 5 m (16.4 ft)
2711-CBL-PM10 RS-232 operating/programming cable for connecting PanelView Component terminals to MicroLogix controllers. 9-pin D-shell to 8-pin mini DIN 10 m (32.7 ft)
2711P-CBL-EX04 Ethernet CAT5 crossover cable for use with PanelView Component C600 and C1000 terminals. RJ45 to RJ45 4.3 m (14 ft)
1761-NET-AIC AIC+ advanced interface converter, RS-232/RS-485. — —
Rockwell Automation Publication VIEW-SG001G-EN-P - August 2011 29
PanelView Component Terminals
Tables 50…53 lists required cables for runtime communication between the PanelView Component terminals and controllers.
Table 50 - Runtime Communication Cables: PanelView Component Terminals to SLC Controllers
Protocol PanelView Component Comm Port
SLC-500, 5/01, 5/02CH1 RJ45 (DH-485)
SLC-5/03, 5/04, 5/05CH0 (9-pin RS-232)
(DF1 or DH-485)
SLC 5/03CH1 (RJ45)
(DH-485)SLC 5/04
CH1 (DH+)SLC 5/05
CH1 (ENET)
DF1 RS-232 (DF1) port (9-pin) — 1747-CP3 (3 m/10 ft) — — —
DH-485RS-232 (DH-485) port (9-pin)
Use AIC+ Module(1761-NET-AIC) to
connect to port 1 or 21747-CP3 (3 m/10 ft)
Use AIC+ Module(1761-NET-AIC) to
connect to port 1 or 2
— —
RS-485 (DH-485) port (5-pin) 2711C-CBL-AB03(1) — 2711C-CBL-AB03(1) — —
EtherNet/IP EtherNet/IP port —Use 1761-NET-ENI module
with Ethernet cable— —
1585J-M type cable or 2711P- CBL-EX04
(4 m/14 ft) (2)
(1) The AIC+ module is recommended for isolation purposes when the terminal and controller are not on the same power supply.(2) For a direct connection between the terminal and controller, use the 2711P-CBL-EX04 crossover cable.
Table 51 - Runtime Cables: PanelView Component Terminals to MicroLogix Controllers
Protocol PanelView Component Comm Port
MicroLogix 1400, 1500LRPCH1/CH2 (9-pin RS-232)
(DF1 or DH-485)
MicroLogix 1000, 1100, 1200, 1400, 1500LSPCH0 (8-pin Mini DIN)
(DF1 or DH-485)MicroLogix 1100, 1400
Ethernet
DF1 RS-232 (DF1) port (9-pin) 1747-CP3 (3 m/10 ft)1761-CBL-PM02 (2 m/6.5 ft)2711-CBL-PM05 (5 m/16 ft)
2711-CBL-PM10 (10 m/12 ft) (1)—
DH-485 RS-232 (DH-485) port (9-pin) 1747-CP3 (3 m/10 ft)1761-CBL-PM02 (2 m/6.5 ft)2711-CBL-PM05 (5 m/16 ft)
2711-CBL-PM10 (10 m/12 ft) (1)—
EtherNet/IP EtherNet/IP PortUse 1761-NET-ENI module
with Ethernet cable1585J-M type cable or
2711P- CBL-EX04 (4 m/14 ft) (2)
(1) The AIC+ module is recommended for isolation purposes when the terminal and controller are not on same power supply.(2) For a direct connection between the terminal and controller, use the 2711P-CBL-EX04 crossover cable.
Table 52 - Runtime Cables: PanelView Component Terminals to CompactLogix Controllers
Protocol PanelView Component Comm Port
CompactLogixCH0 (9-pin RS-232)
(DF1 or DH-485)
DF1 RS-232 (DF1) port (9-pin)2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
DH-485 RS-232 (DH-485) port (9-pin)2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
EtherNet/IP EtherNet/IP port 1585J-M type cable or 2711P- CBL-EX04 (4 m/14 ft) (1)
(1) For a direct connection between the terminal and controller, use the 2711P-CBL-EX04 crossover cable.
Table 53 - Runtime Cables: PanelView Component Terminals to Interface Modules
ProtocolPanelView Plus
Comm Port1761-NET-AICPort 1 (9-pin)
1761-NET-AICPort 2 (8-pin Mini DIN()
1761-NET-AICPort 3 (DH-485)
DF1 RS-232 port (9-pin) 1747-CP3 (3 m/10 ft)1761-CBL-PM02 (2 m/6.5 ft)2711-CBL-PM05 (5 m/16 ft)
2711-CBL-PM10 (10 m/12 ft) —
DH-485 RS-232 port (9-pin) 1747-CP3 (3 m/10 ft)1761-CBL-PM02 (2 m/6.5 ft)2711-CBL-PM05 (5 m/16 ft)