selectron ic concealed model numbers s ...240mm max. (9-1/2)max. fig. 1 roughing-in dimensions...
TRANSCRIPT
Ins
tall
ati
on
In
str
uc
tio
ns
Certified to comply with ASME A112.19.2
© 2014 AS America, Inc.
SELECTRONIC®CONCEALEDTOILET FLUSH VALVE1.28 & 1.6 GPF
Concealed Flushometerfor 1-1/2" Top or Back Spud Bowls
CLOG RESISTANT
ONE SENSOR FITS ALL
6065.22X6067.22X 6068.22X
MODEL NUMBERS
6065.26X6067.26X6068.26X
• Self-cleaning piston valve prevents clogging and reduces maintenance.
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.• Range can be adjusted manually or with optional remote control.• Sensor Features Low Battery Indicator.
M965640 (11/14)
CAUTION: Use only American Standard supplied cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
Concealed Back SpudExposed Back Spud Top Spud
NOTE TO INSTALLER: Please give this manual to the customer after installation.NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.comor e-mail us at: [email protected]
For Parts, Service, Warranty or other Assistance,please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping.
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKINGRemove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.
1M965640 (11/14)
3
4
1
6
8c8b8a
5
DO NOT REMOVE PROTECTIVEFILM FROM SENSOREYE UNTIL INSTALLATIONIS COMPLETE.
T O P
2
7
606X.2X1 606X.2X2
VACUUM BREAKER FLUSH CONNECTIONS
606X.2X3
1. Installation Instructions
2. Flush Valve Body Assembly
3. Cover Plate with Sensor4. Electrical Box5. Sweat Adapter
Vacuum Breaker Flush Connection(Top Spud)DC Standard Battery and Battery HolderAC Power Supply (Model# 6067)27" Cable Extension, Qty. (2)Y-Adapter10' Extension
8c.
9a.
9b.
10.
11.
12.
Stop ValveManual Override Hoses
Vacuum Breaker Flush Connection(Exposed Back Spud)
Vacuum Breaker Flush Connection(Concealed Back Spud)
6.
8a.
8b.
7 .
Ins
tall
ati
on
In
str
uc
tio
ns
Ins
tall
ati
on
In
str
uc
tio
ns
Certified to comply with ASME A112.19.2
© 2014 AS America, Inc.
SELECTRONIC™CONCEALEDTOILET FLUSH VALVE1.28 & 1.6 GPF
Concealed Flushometerfor 1-1/2" Top or Back Spud Bowls
CLOG RESISTANT
ONE SENSOR FITS ALL
6065.22X6067.22X 6068.22X
MODEL NUMBERS
6065.26X6067.26X6068.26X
• Self-cleaning piston valve prevents clogging and reduces maintenance.
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and !ush valves.• Range can be adjusted manually or with optional remote control.• Sensor Features Low Battery Indicator.
M965640 (11/14)
CAUTION: Use only American Standard supplied cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
Concealed Back SpudExposed Back Spud Top Spud
10 10 10
12
1111
9b
9a
DC StandardBattery
6065. Series
Power Source
AC Plug-in6067. Series
AC Multi6068. Series
NOTE TO INSTALLER: Please give this manual to the customer after installation.NOTE TO INSTALLER: Please give this manual to the customer after installation.To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.comor e-mail us at: [email protected]
For Parts, Service, Warranty or other Assistance,please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
RECOMMENDED TOOLS; Fig. 2 Fig. 21.2.3.4.5.6.7.8.9.
10.
Teflon Tape Flat Blade ScrewdriverAdjustable Wrench Tape Measure HacksawTubing CutterFileFor Sweat Connection; Solder and Torch2.5mm Hex Wrench1.5mm Hex Wrench
1 2 3
4
56
7 9 10
8
• Flush all water lines prior to operation (See Step 3). Dirt and debris can cause flush valve to run continuously.
• With the exception of Stop Valve Inlet, DO NOT use pipe sealant or plumbing grease on any valve component or coupling!
• Protect the chrome or special finish on chrome plated items.DO NOT USE toothed tools on finished surfaces to install or service these valves. Also see “Care and Cleaning” section of this manual.
• This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve’s performance.
2
10'
M965640 (11/14)
PRIOR TO INSTALLATIONNote: Prior to installing the Selectronic™Flush Valve the following items must be installed.
1. Toilet
2. Drain line
3. Water supply line
IMPORTANT:• All plumbing and electrical wiring must be installed in accordance with applicable codes, regulations and standards.• The use of water hammer arrestors is strongly recommended for commercial applications. All piping behind the walls should be properly secured and fastened.• Water supply lines must be sized to provide an adequate volume of water for each fixture.
240mm MAX.(9-1/2) MAX.
Fig. 1
Roughing-inDimensions
GENERAL DESCRIPTION:
Concealed Flushometerfor 1-1/2" Spud Fixtures
SELECTRONIC™PROXIMITY TOILET FLUSH VALVE
Exclusive, self cleaning piston-type flush valve with proximity operation and manual override. Operates on DC (battery) or AC power (Plug-in). Recommended operating pressure 25psi (flowing) to 80 psi (static). Can install left or right-handed. Detection Zone can also be adjusted manually, or with optional remote control.
-C-L- -C-L-
51mm(2)
70mm(2-3/4) DIA.
25mm (1) MAX.
160mm(6-1/4)
OVERRIDEBUTTON
160mm(6-1/4)
127mm X 127mm(5X5 CUTOUTFOR BOX)
128mm MAX.(5) MAX.400mm MAX.
(15-3/4) MAX.
FOR LOCATION OF INLET SUPPLY ON BACK INLETFIXTURES AND CORRECT HEIGHT FROM FINISHED FLOOR,
REFER TO FIXTURE INSTRUCTION SHEET.
FINISHEDWALL
CONCEALED BACKSPUD TOILET
EXPOSED BACKSPUD TOILET
TOP SPUDTOILET
TOP OFFIXTURE
FINISHEDFLOOR
FINISHEDFLOOR
FINISHEDFLOOR
TOP OFFIXTURE
SENSOR
SUPPLY(1) NPT
108mm-134mm(4-1/4 TO 5-1/4)
*Note: The Critical Line (-C-L-) on VacuumBreaker must typically be 6" (152mm) min.above fixture. Consult Codes for details.
51mm(2)
51mm(2)
WALL THICKNESS
15˚
TOP OFFIXTURE
CAUTION: Use only American Standard supplied cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
450mm MAX.(17-3/4) MAX.
DETECTION ZONE400mm-800mm(Factory Setting: 400mm)
152mm MIN.(6) MIN.
*-C-L-
152mm MIN.(6) MIN.
*-C-L-
360mm MAX.(14-3/16) MAX.
Fig. 4
Fig. 5
3
INSTALL ELECTRICAL BOX; Fig. 31. Cut a 127x127mm (5"x 5") opening in finished wall for ELECTRICAL BOX (1) at the dimension shown.
2. Rotate the 4 MOUNTING TABS (2) flat against the electrical box. Holding the MOUNTING TABS (2) in position, install the ELECTRICAL BOX (1) into the opening. Make sure the MOUNTING TABS (2) are behind the wall.
3. Tighten the the 4 MOUNTING SCREWS (3) until the ELECTRICAL BOX (1) is almost secure in the wall. Before tighting fully, rest a level at the top edge of the ELECTRICAL BOX (1) and make sure the box is level.
4. Cut a 2" diameter hole for outlet pipe at dimension shown.*
1
Fig.3 (TOP SPUD FIXTURE ILLUSTRATED)
1
3
2
2
1
1
1. Open STOP VALVE (1).
3. Turn on water supply line to flush line of any debris orsediment.
4. Close STOP VALVE (1) and turn off water supply line.
FLUSH OUT SUPPLY LINES; Fig. 53
*FOR HOLE LOCATION OFOUTLET PIPE ON BACK INLETFIXTURES, REFER TO FIXTUREBEING INSTALLED FOR CORRECTHEIGHT FROM FINISHED FLOOR
127mm(5)
127mm(5)
INSTALL SWEAT ADAPTER; Fig. 4CAUTION Turn water supplies off before beginning
Note: Stop Valve inlet is 1" NPT. For optional sweat connection, install Sweat Adapter (1) (Supplied) for 1" copper pipe supply line.
1. Clean the end of the supply pipe. Push the threaded SWEAT ADAPTER (1) until it is seated against the internal stop. Sweat the ADAPTER (1) to the pipe.
2. Install the STOP VALVE (2) to the water supply line with the outlet positioned as required (Behind the Wall).
3. Support piping as required.
2
T O P
FILEEDGES
CLEAN & SOLDER TO ADAPTER (1)
115mm-134mm(4-1/2 TO 5-1/4)
STOP VALVE(1" NPT)
STOPVALVE
OUTLET
CLOCKWISE CLOSESSTOP VALVE
COUNTER-CLOCKWISEOPENS STOP VALVE
T O P
T O P
2
128mm MAX.(5) MAX.
M965640 (11/14)
FLUSH VALVE INSTALLATION
360mm MAX.(14-3/16) MAX.
M965640 (11/14)4
Fig. 6
Fig. 6a
Fig. 6b
Fig. 6c
34 INSTALL VACUUM BREAKER ANDFLUSH CONNECTIONS; Fig. 64
1. Place the SPUD FLANGE (1) over the spud on the Fixture. Fig. 6.
2. Place FRICTION WASHER (3) and SEAL WASHER (4) inside SPUD COUPLING NUT (2) and thread onto Spud. Do not ntighten fully. Fig. 6.
3. Remove the ELBOW COUPLING NUTS (6, 6a) from the CHROME ELBOW (5). Make sure you have a TAPERED RUBBER WASHER (7), PLASTIC SUPPORT (8) and SQUARE SEAL WASHER (9). Fig. 6a.
4. Install the SQUARE SEAL WASHER (9) onto the PLASTIC SUPPORT (8) if not already installed. Insert the PLASTIC SUPPORT (8) into the VERTICAL OUTLET PIPE (10). Slide the ELBOW COUPLING NUT (6) onto the VERTICAL OUTLET PIPE (10). Connect the ELBOW COUPLING NUT (6) to the CHROME ELBOW (5) and tighten fully.
5. Insert the VERTICAL OUTLET PIPE (10) with assembled CHROME ELBOW (5) into the SPUD COUPLING NUT (2) and push it down. Do not tighten fully. Fig. 6a.
Note: Cutting the VERTICAL OUTLET PIPE (10) may be necessary for the CHROME ELBOW (5) center line to line up with opening in the wall.
6. Measure and cut the HORIZONTAL OUTLET PIPE (11) to length required. Fig. 6b.
Important: Make sure that there is a minimum of 1-1/4" for engagement with elbow when making your measurement.
7. Remove the ELBOW COUPLING NUT (14) from BRASS ELBOW (12) and slide it onto the HORIZONTAL OUTLET PIPE (11). Install the SQUARE SEAL WASHER (13) onto the PLASTIC SUPPORT (15) if not already installed. Insert the PLASTIC SUPPORT (15) into the HORIZONTAL OUTLET PIPE (11). Connect the ELBOW COUPLING NUT (14) to the BRASS ELBOW (12) and tighten fully. Fig. 6b.
8. From behind the wall, insert the assembled BRASS ELBOW and HORIZONTAL OUTLET PIPE (12, 11) through the hole in the wall. Install WALL ESCUTCHEON (16) onto the HORIZONTAL OUTLET PIPE (11). Slide the ELBOW COUPLING NUT (6a) and TAPERED RUBBER WASHER (7) onto the HORIZONTAL OUTLET PIPE (11). Push the HORIZONTAL OUTLET PIPE (11) into the CHROME ELBOW (5). Tighten ELBOW COUPLING NUT (6a) but not fully. Fig. 6b.
9. For back spud installations: Follow steps #1 and #2 to install the spud coupling kit. Push the HORIZONTAL OUTLET PIPE (11) into the spud connection on the back of the fixture. Do not tighten fully. If spud coupling kit is not required, install HORIZONTAL OUTLET PIPE (11) into back spud on fixture and hand tighten. Fig. 6b.
10. All installations: If required, cut scored VACUUM BREAKER PIPE (17), leave a minimum of 1-1/4" (32mm) of pipe to ensure engagement with compression coupling. Assemble the ELBOW COUPLING NUT (14a) and TAPERED RUBBER WASHER (19) onto the VACUUM BREAKER PIPE (17). Install VACUUM BREAKER PIPE (17) into BRASS ELBOW (12) and hand tighten COUPLING NUT (14a). Fig. 6c.
Note: If cutting VACUUM BREAKER PIPE (17) to size, note that Critical Line (C/L) on Vacuum Breaker must typically be 6" (152mm) above fixture. Consult Code for details.
1
23 4
1-1/2" TOP SPUD
9
6a
8
7
5
610
FLANGE END UP
2
TAPERED SIDE
14
1612
11
15
57
6a
13
FLANGE END
11
14a
19
19
17
TOP SPUDINSTALLATION
BACK SPUDINSTALLATION
BACK SPUDINSTALLATION TOP SPUD
INSTALLATION
TAPEREDSIDE
12
TAPERED SIDE UP
TAPEREDSIDE UP
7
9
6
25
10
Fig. 8
Fig. 7
5
7
1. Insert the side ADJUSTABLE TAILPIECE (1) on the FLUSH VALVE (2) into the STOP VALVE (3). Lubricate the TAILPIECE O-RING (4) with water if necessary. Thread the COUPLING NUT (5) onto the STOP VALVE (3) and tighten lightly. Fig. 7.
Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape.
INSTALL FLUSH VALVE; Fig. 75
1. Align the FLUSH VALVE BODY (2) directly above the VACUUM BREAKER TUBE (7) and VACUUM BREAKER COUPLING NUT (6). Make sure that GASKET (10) is installed.
Note: There is a +13mm, -6mm (+1/2"-1/4") tolerance for the 121mm (4-3/4) dimension.
2. Pull the VACUUM BREAKER TUBE (7) up to meet the threaded FLUSH VALVE (2) and hand tighten the COUPLING NUT (6). Align all components of the flush valve assembly.
3. Lightly tighten the TAILPIECE COUPLING NUT (5) connection first, then the VACUUM BREAKER COUPLING NUT (6) and finally the SPUD COUPLING NUT (9). Once alligned correctly, use a wrench to tighten all couplings to make water tight connections.
4. Secure piping behind wall as required.
CONNECT FLUSH VALVE TOVACUUM BREAKER TUBE; Fig. 86
3
25 4
1
121mm,+13mm, -6mm(4-3/4)(+1/2, -1/4)
M965640 (11/14)
M965640 (11/14)66
T O P
21
3
4
7
68
10
ELECTRICALOUTLET
59
TERMINAL SIDE
Fig. 9
Fig. 10
Fig. 10a
1
6
3
4
25
8 AC VERSION; Fig. 9, 10a
1. Attach the SAFETY CHAIN (1) from the COVER PLATE (2) to the MOUNTING POST (3) as shown. Fig. 9.
2. Connect one end of the 27" EXTENSION CABLE (1) to one SENSOR CABLE (2). Connect the other end of the 27" EXTENSION CABLE (1) to the SOLENOID CABLE (3). Fig.10.
3. Insert BATTERY (6) into BATTERY HOLDER (4), making sure terminal side is inserted first. Fig.10
4. Connect BATTERY HOLDER (4) to available SENSOR CABLE (5). Place BATTERY HOLDER (4) into electrical box. Fig.10.
1. Attach the SAFETY CHAIN (1) from the COVER PLATE (2) to the MOUNTING POST (3) as shown. Fig. 9.
2. Connect one end of the first 27" EXTENSION CABLE (4) to one SENSOR CABLE (5). Connect the other end of the 27" EXTENSION CABLE (4) to the SOLENOID CABLE (6).Fig.10a.
3. Connect AC POWER SUPPLY (8) to the single terminal of the Y-ADAPTER (10). Fig.10a.
4. Connect one end of the second 27" EXTENSION CABLE (7) to one of the two available terminals of Y-ADAPTER (10), and the other end of the 27" EXTENSION CABLE (7) to available SENSOR CABLE (9). Fig.10a.
5. Plug AC POWER SUPPLY (8) into outlet. Fig. 10a.
6. Place Y-ADAPTER (10) into electrical box.
7 DC VERSION; Fig. 9, 10
ELECTRICAL INSTALLATION
M965640 (11/14)7
2
Fig. 11
Unit #1 Unit #2 Unit #3
Unit #4
POWER SUPPLY
MAXIMUM OF 15 UNITS PER POWER SUPPLY. 10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
9 MULTI-AC VERSION (DAISY-CHAIN); Fig. 11
CAUTION: Use only American Standard supplied cable sets. Using non-AS supplied cables, or cutting, splicing or modifying any components will void the warranty.
3
4
1
4
3a
Important: Disconnect AC Power Supply from wall outlet before making daisy-chain connections.
Note: For Unit #1 installation instructions, refer to AC version section (page 6).
For subsequent Units...
1. Take the first 27" EXTENSION CABLE (1) and connect one end to the solenoid cable, the otherend to a sensor cable.
2. Take the second 27" EXTENSION CABLE (2) and connect one end to the available sensorcable, the other end to one of the two terminals at the one end of the Y-ADAPTER (3).
3. Take the 10' EXTENSION (4) and connect one end to the single terminal of Y-ADAPTER (3), andthe other end to available terminal of the previous unit’s Y-ADAPTER (3a).
4. Repeat process for each subsequent unit.
5. Place Y-ADAPTERS (3) into respective electrical box.
6. Plug in AC power supply into wall outlet once all daisy-chain unit connections have been made.
(See AC version installationinstructions, page 6)
Already installed
TO FLUSHVALVE SOLENOID
TO FLUSHVALVE SOLENOID
TO FLUSHVALVE SOLENOID
INSTALL COVER PLATE; Fig. 12
M965640 (11/14)8
1. Push the BLACK HOSE (1) into the BOTTOM HOSE CONNECTOR (2) on flush valve body and push the other end into the back of the MANUAL OVERRIDE VALVE (3).
2. Push the BLUE HOSE (4) into the TOP HOSE CONNECTOR (15) on flush valve body and push the other end into the BOTTOM CONNECTOR (6) of the manual override valve.
CONNECT OVERRIDE HOSES,AC & DC POWER; Fig. 1311
10
2
5
4 BLUEHOSE
1 BLACKHOSE
Fig. 13
6
3
T O P
Fig. 12
1. Install the two TABS (1) on the back side of COVER PLATE (2) into the two SLOTS (3) located on the top edge of the ELECTRICAL BOX (4).
2. Push on the bottom edge of the COVER PLATE (2) until it snaps into place. If COVER PLATE (2) will not snap into place, then loosen the MOUNTING SCREWS (6) on the ELECTRICAL BOX (4) slightly.
3. To remove COVER PLATE (2), insert WIRE KEY (5) (supplied) into the two holes located at the bottom of the COVER PLATE (2). Push the WIRE KEY (5) up until it releases the bottom clips. Pull the bottom edge away and lift the COVER PLATE (2) off.
PUSH TOSNAP PANELINTO PLACE
5
6
2
1
23
4
M965640 (11/14)
INSTALL NEWBATTERY
CR-P2
CR-P2
Fig. 14
9
Fig. 15
CLOCKWISE CLOSESSTOP VALVE
COUNTER-CLOCKWISEOPENS STOP VALVE1
2
INSTALL NEW BATTERY;Fig. 14
14
32
IMPORTANT: To avoid overflowing, the STOP VALVE (2) must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture. Valve is designed to provide stated flush volume with a 25 GPM flow rate.
1. After installation is complete, peel off the PROTECTIVE FILM (1) from the sensor. Standing to one side, block the sensor with your hand for 10 seconds. Remove your hand and listen for audible “click” from within the valve.
2. Turn on STOP VALVE (2) 1/4 turn to 1/2 turn(CCW) and test for leaks.
Note: Unit may flush for approximately 5 to 10 seconds when water is first turned on. If flow persists, turn water off and repeat step #1 above.
3. Actuate the FLUSH VALVE: A)
B)
4. Adjust STOP VALVE (2) after each flush until the stated flush volume is achieved, no splashing occurs and the fixture is properly cleansed.
ADJUST STOP VALVE; Fig. 15
1. Remove the COVER PLATE (1). For removing front panel instructions, see Step 10.
2. Remove old BATTERY (2) from BATTERY HOLDER (4). Install the new BATTERY (3), making sure the shape of the BATTERY (2) follows the shape of the BATTERY HOLDER (4).
3. Install COVER PLATE (1).
A
B
MAINTENANCE
Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection area.
Remove hand from dection area; unit willflush in approximately 3 seconds.
M965640 (11/14)10
Fig. 16
213
1 1
4
Fig. 17
1" - 2" (30mm - 50mm)
BLINKING LED
5 BLINKING LED
SET DETECTION RANGE(If Required); Fig. 16 & 17.Note: The detection distance is preset and ideal for most installations. Should an adjustment be required, follow the steps below.
1. Remove COVER PLATE (1). See Step 10 for front panel removal instructions.
2. Disconnect SENSOR CABLE (2) from BATTERY HOLDER (3) or from POWER SUPPLY 27" EXTENSION CABLE (4). Fig. 16.
3. Keeping hands away from the front of the sensor, reconnect the SENSOR CABLE (2). Do not secure the COVER PLATE (1) at this time. Fig. 16.
Note: You have 5 seconds to begin entering the program code after power connection is made.
4. While the SENSOR CONTROL LED (5) is blinking slowly, place your hand 1 to 2". (30-50mm.) in front of the sensor. Fig. 17.
5. When the LED (5) stops blinking and stays "ON", move your hand to the desired position from sensor and hold in place until the LED (5) begins to blink again. Fig. 17.
Note: Detection Zone is 400mm - 800mm.(Factory Setting: 400mm) 6. Once the SENSOR CONTROL LED (5) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set.
7. Replace and secure COVER PLATE (1).
8. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds.
Note: Stand outside of sensor detection area.
B) Remove hand from detection area; unit will flush in approximately 3 seconds.
C
DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES,HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
T O P
DETECTION ZONE400mm - 800mm
(Factory Setting: 400mm)
11 M965640 (11/14)
TROUBLESHOOTING FLOW CHARTS
NNOO
YYEESS
NNOO
YYEESS
NNOO
11 22
11 22
YYEESS
NNOO
YYEESS
NNOO
UNIT DOES NOT FUNCTION
NNOO
NNOO
11
22
11
22
YYEESS
NNOO
NNOO
YYEESS
UNIT WILL ONLY FLUSH MANUALLY
YYEESS
NNOO
NNOO
11
22
11
22
NNOO
YYEESS
UNIT IS CONTINUOUSLY FLUSHING
OPEN VALVE
CRITICALLY LOW BATTERY . INSTALLNEW BATTERY
DEAD BATTERY. INSTALL NEWBATTERY. REPEAT.DAMAGED SENSOR WIRE. REPLACESENSOR. (ONLY IF ABSOLUTELY NEEDED)
DAMAGED SOLENOID. REPLACESOLENOID
DAMAGED MANUAL OVERRIDEBUTTON. REPLACE MANUALOVERRIDE BUTTON
DEAD BATTERY. INSTALL NEWBATTERY. REPEAT.
DAMAGED SENSOR WIRES. REPLACESENSOR. (ONLY IF ABSOLUTELY NEEDED)
DAMAGED SENSOR WIRES. REPLACESENSOR. (ONLY IF ABSOLUTELY NEEDED)
CRITICALLY LOW BATETRY. INSTALLNEW BATTERY
IS ANGLE STOP OPEN?
REPEATED DOUBLEFLASH ON SENSOR?
RECONNECT BATTERY TO SENSOR.FLASH ON SENSOR FOR 5SECONDS?
PUSH MANUAL OVERRIDEBUTTON; WILL THE UNIT FLUSH?
REPLACE PISTON ASSEMBLY.
CLOSE ANGLE STOP AND OPENAGAIN TO PRIME THE VALVE.DOES FLUSHING STOP?
PUSH MANUAL OVERRIDEBUTTON. DOES IT RETURN TO ITSORIGINAL POSITION FREELY?
RECONNECT BATTERY TO SENSOR.FLASH ON SENSOR FOR 5SECONDS?
REPLACE PISTON & SOLENOIDASSEMBLY.
REPEATED DOUBLEFLASH ON SENSOR?
RECONNECT BATTERY TO SENSOR.FLASH ON SENSOR FOR 5SECONDS?
REPLACE SOLENOID.
DEAD BATTERY. INSTALL NEWBATTERY. REPEAT.
HOT LINE FOR HELPFor toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
Product names l isted herein are trademarks of AS America, Inc. ©2014
To learn more about American Standard Selectronic® Products visit our website at:www.americanstandard-us.com or e-mail us at: [email protected]
12 M965640 (11/14)
M950319-0071600ASENSOR ASSEMBLY (1.6 gpf)
M950319-0071280ASENSOR ASSEMBLY (1.28 gpf)
A906680-0070ABONNET NUT
M964941-0021280ACOVER WITH SENSOR (1.28 gpf)
M964941-0021600ACOVER WITH SENSOR (1.6 gpf)
M962745-0070AELECTRICAL BOXASSEMBLY
M962749-0070ACHAIN ASSEMBLY
A922270-0070A“U” KEY FOR COVER
M962754-0070A1" STOP VALVE KIT
M964945-0020AADJUSTABLE TAILPIECE
M962926-0070A1" SWEAT ADAPTER
A912809-0070AO-RING
M962750-0070AMANUAL VALVE
HOSE KIT
T O P M964944-0020AMANUAL OVERRIDE BUTTON
M964402-0070AVACUUM BREAKER KIT
M964551-0070APISTON ASSEMBLY
M964302-0070ASOLENOID ASSEMBLY
M964852-0070ASOLENOID & PISTONSUBASSEMBLY
SELECTRONIC®
PROXIMITY TOILETCONCEALED FLUSH VALVE
1.28 & 1.6 GPF
6065.22X6067.22X 6068.22X
MODEL NUMBERS
6065.26X6067.26X6068.26X
M950510-0070A27" EXTENSION
CABLE
M950510-0070A27" EXTENSION CABLE
M950510-0070A27" EXTENSION CABLE
6065. Series
6067. Series
6068. Series
M950338-0070APOWER SUPPLY
M950511-0070A10' EXTENSION
A923654-0070ABATTERY 6V CR-P2
M950514-0070ABATTERY HOLDER
AC Plug-in
AC Multi
DC STANDARD BATTERY
M950512-0070AY-ADAPTER
M950512-0070AY-ADAPTER
M950216-0020AVACUUM BREAKER FLUSH
CONNECTION KIT(Top Spud)
M950218-0020AVACUUM BREAKER FLUSH
CONNECTION KIT(Exposed Back Spud)
(FOR MODEL 606X.2X1) (FOR MODEL 606X.2X2) (FOR MODEL 606X.2X3)
M950217-0020AVACUUM BREAKER FLUSH
CONNECTION KIT(Concealed Back Spud)
M962748-0070ASENSOR MOUNTING KIT(SMALL PLATE)
HOT LINE FOR HELPFor toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
Product names l isted herein are trademarks of AS America, Inc. ©2014
To learn more about American Standard Selectronic® Products visit our website at:www.americanstandard-us.com or e-mail us at: [email protected]