self-contained breathing apparatus
DESCRIPTION
Self-Contained Breathing Apparatus. Objectives (1 of 2). List two conditions requiring respiratory protection. List and explain the effects of oxygen deficiency and toxic gases on the human body. List one legal requirement for use of SCBA. List two types of SCBA. - PowerPoint PPT PresentationTRANSCRIPT
CHAPTER
7
7.2
Copyright © 2007 Thomson Delmar Learning
Objectives (1 of 2)
• List two conditions requiring respiratory protection.
• List and explain the effects of oxygen deficiency and toxic gases on the human body.
• List one legal requirement for use of SCBA.
• List two types of SCBA.
• List four components of the SCBA used by the authority having jurisdiction.
CHAPTER
7
7.3
Copyright © 2007 Thomson Delmar Learning
Objectives (2 of 2)
• Demonstrate two different SCBA donning procedures.
• Demonstrate routine inspection of SCBA.• Demonstrate after-use maintenance and
servicing.• Demonstrate the servicing of an SCBA
cylinder with the air-filling system.
CHAPTER
7
7.4
Copyright © 2007 Thomson Delmar Learning
Introduction (1 of 3)
• SCBA an important item of PPE.• SCBA allows firefighters to work in
oxygen deficient atmospheres.• Human body very vulnerable to oxygen
deficient atmosphere.• Respiratory protection policy must exist.• SCBA required in an IDLH area.
CHAPTER
7
7.5
Copyright © 2007 Thomson Delmar Learning
Introduction (2 of 3)
• Many changes in SCBAs since the 1970s– Decrease in weight– Must be positive pressure– Improved design– SCBA maintenance programs– PASS devices– Better training programs– Increased regulations
CHAPTER
7
7.6
Copyright © 2007 Thomson Delmar Learning
Introduction (3 of 3)
• Improvements– Technology– Regulations– Mandates
• SCBA improvements are only as effective as the training and proficiency firefighters develop in using SCBA.
CHAPTER
7
7.7
Copyright © 2007 Thomson Delmar Learning
Conditions Requiring Respiratory Protection
• Oxygen deficiency
• High temperatures
• Smoke
• Unburned products of combustion
• Toxic environment
CHAPTER
7
7.8
Copyright © 2007 Thomson Delmar Learning
Oxygen-Deficient Environments
• Humans and fire both require oxygen to survive.
• Oxygen deficiency is detrimental to the human body.
CHAPTER
7
7.9
Copyright © 2007 Thomson Delmar Learning
Elevated Temperatures and Smoke
• Inhalation of heated gases can cause fluid to build up in the lungs and create long-term, irreversible damage.
• Combustion by-products are very irritating to the body.
• High temperatures can also cause severe burns to the respiratory system.
CHAPTER
7
7.11
Copyright © 2007 Thomson Delmar Learning
Effects of Toxic Gases and Environments (1 of 2)
• Toxic gases are produced by combustion.– These gases affect various body systems.
• Hazardous materials can increase the risk to firefighters.
• CO is one of the most lethal gases produced by fire.– CO attaches to blood 218 times easier than O2.
CHAPTER
7
7.12
Copyright © 2007 Thomson Delmar Learning
Effects of Toxic Gases and Environments (2 of 2)
• CO prevents distribution of O2 in the body, causing hypoxia.
• Without SCBA, a firefighter will not survive.
• Repeated exposure to toxins has long-term effects.
CHAPTER
7
7.13
Copyright © 2007 Thomson Delmar Learning
Legal Requirements for SCBA
• OSHA - Respiratory Protection Standard Title 29 CFR 1910.134
• 29 CFR 1910.134 standard for all entries into IDLH atmospheres
• NFPA standards (1500, 1404, 1981)
• NIOSH 42 CFR Part 84
CHAPTER
7
7.14
Copyright © 2007 Thomson Delmar Learning
Organizations Concerned with SCBA Design and Use
ORGANIZATION STANDARD APPLICATION
National Institute for Occupational Safety & Health (NIOSH)
42 CFR Part 84 Requirements for design, testing, certifying SCBA
Occupational Safety & Health Administration (OSHA)
29 CFR 1910.134 Respiratory protection programs for SCBA use
Occupational Safety & Health Administration
29 CFR 1910.156 Fire Brigade Standard, references 1910.134
National Fire Protection Association
NFPA 1404 Standard for Fire Department SCBA Program
National Fire Protection Association
NFPA 1500 Standard on Fire Department Occupational Safety & Health Program
National Fire Protection Association
NFPA 1981 Standard on Open-Circuit SCBA for the Fire Service
Organizations Concerned with SCBA Design and Use
CHAPTER
7
7.15
Copyright © 2007 Thomson Delmar Learning
Limitations of SCBA (1 of 2)
• SCBA design and size– Increases weight and girth– Decreases mobility– Requires good physical conditioning– Must be aware of how long air will
last– Limits visibility– Voice muffled and hard to
understand
CHAPTER
7
7.16
Copyright © 2007 Thomson Delmar Learning
Limitations of SCBA (2 of 2)
• Limitations of SCBA user– Factors such as facial hair or weight loss can
alter mask effectiveness.
– Lack of confidence can lead to anxiety.
– Training/experience will improve confidence and ability.
– Increased physical stress causes anxiety.
– Emotional state may affect respiratory rate and air consumption.
CHAPTER
7
7.18
Copyright © 2007 Thomson Delmar Learning
Types of SCBA
• Two types of SCBA in use– Open-circuit SCBA– Closed-circuit SCBA
• Both built according to NIOSH and NFPA standards
CHAPTER
7
7.20
Copyright © 2007 Thomson Delmar Learning
Open-Circuit SCBA (2 of 2)
• SCBA has four assembly components.– Backpack and harness– Cylinder– Regulator– Face piece assembly
CHAPTER
7
7.22
Copyright © 2007 Thomson Delmar Learning
Open-Circuit SCBA — Cylinders (1 of 2)
• SCBA cylinders vary in material and type.
• USDOT regulates compressed gas cylinders.
• Quality of the compressed breathing gas has a direct effect on the performance of the SCBA.
CHAPTER
7
7.23
Copyright © 2007 Thomson Delmar Learning
Open-Circuit SCBA — Cylinders (2 of 2)
RATED DURATION (MINUTES)
MATERIAL CYLINDER PRESSURE (PSI)
CAPACITY COMPRESSED AIR (FT3)
30 Aluminum or Composite 2,216 44
30 Aluminum or Composite 4,500 44
45 Carbon Fiber 3,000 65
45 Aluminum or Composite 2,216 65
45 Aluminum or Composite 4,500 65
60 Aluminum or Composite 4,500 88
SCBA Air Cylinder Capacities
CHAPTER
7
7.24
Copyright © 2007 Thomson Delmar Learning
SCBA Regulator (1 of 2)
• Regulator is attached to the face piece or waist strap.
• Regulator has a pressure gauge.
• Regulator is activated by user’s breathing action.
CHAPTER
7
7.25
Copyright © 2007 Thomson Delmar Learning
SCBA Regulator (2 of 2)
• The regulator maintains constant positive pressure airflow to the face piece.
• Units have low air supply warning alarm.
• NFPA 1981 requires two types of alarms.
CHAPTER
7
7.26
Copyright © 2007 Thomson Delmar Learning
SCBA Face Pieces
• Annual face piece fit test is required.
• Exhalation valve keeps toxic gases out.
CHAPTER
7
7.27
Copyright © 2007 Thomson Delmar Learning
Closed-Circuit SCBA
• Not used for regular firefighting operations
• Commonly used for hazmat operations and below-grade rescues
• Contains cylinder, filter system, regulator, and valves
CHAPTER
7
7.28
Copyright © 2007 Thomson Delmar Learning
Open-Circuit Supplied Air Respirator (SAR)
• Air supply cylinder is remote from user.
• It provides user with long- duration air supply.
• It is used for hazmat operations and confined space rescues.
CHAPTER
7
7.29
Copyright © 2007 Thomson Delmar Learning
Donning and Doffing SCBA (1 of 2)
• Perform safety check first.
• Use one of two methods.– Over the head method– Coat method
• SCBA is also mounted in seats.
• Never stand to don while apparatus is moving.
• After securing SCBA, don face piece.
CHAPTER
7
7.30
Copyright © 2007 Thomson Delmar Learning
Donning and Doffing SCBA (2 of 2)
• The proper donning of a face piece is essential.
• After exiting hazardous area, remove SCBA. Remove face piece while waiting for assignment.
• Local protocol may require rehab after assignment.
CHAPTER
7
7.34
Copyright © 2007 Thomson Delmar Learning
SCBA Operation and Emergency Procedures
• Firefighters must be proficient in:– Safe use of SCBA– Donning and doffing procedures– Individual limitations– Limitations of SCBA
CHAPTER
7
7.35
Copyright © 2007 Thomson Delmar Learning
Safe Use of SCBA (1 of 2)
• Firefighters must be physically fit for respirator use.
• Accountability system should be in place.
• Must work in teams of two at a minimum.
• OSHA “two in/two out” regulation.
• PASS device must be activated.
CHAPTER
7
7.36
Copyright © 2007 Thomson Delmar Learning
Safe Use of SCBA (2 of 2)
• SCBA operations should include rehab time.
• Stay hydrated during rehab.• Air consumption will vary for all.• Never remove the face piece in a
contaminated environment.• Low air alarm on one team member
means the whole team exits.
CHAPTER
7
7.38
Copyright © 2007 Thomson Delmar Learning
Operating in a Hostile Environment (1 of 2)
• Always check in/out with accountability officer.
• Always remain low.
• Check the environment.
• Never remove a face piece.
• Be aware of your location at all times.
CHAPTER
7
7.39
Copyright © 2007 Thomson Delmar Learning
Operating in a Hostile Environment (2 of 2)
• Ventilate as you advance.
• Check outside openings.
• Maintain contact with team members.
• Never enter a hostile environment alone.
CHAPTER
7
7.40
Copyright © 2007 Thomson Delmar Learning
Restricted Openings
• Never remove face piece!• Loosen straps and rotate SCBA under
arm.• Remove harness and hold SCBA as a last
resort.• Do not lose contact with SCBA.• Maintain control of unit.• Practice procedures regularly.
CHAPTER
7
7.42
Copyright © 2007 Thomson Delmar Learning
Emergency Procedures with SCBA
• Remain calm.
• Immediately exit hazardous area.
• Activate PASS device.
• Announce your emergency over the radio.
• If regulator or face piece fails, use bypass valve.
• Buddy breathing is only a last resort.
CHAPTER
7
7.43
Copyright © 2007 Thomson Delmar Learning
Inspection and Maintenance of SCBA
• Have SCBA ready to go at all times.
• Routinely inspect SCBA.– Remove unit and check it after each use.– Monthly operational check should be done.
• Service less than full cylinder.
CHAPTER
7
7.44
Copyright © 2007 Thomson Delmar Learning
Servicing SCBA Cylinders
• Test and certify air source.• Cylinders must have current hydrostatic
test date.• Fill stations must have fragmentation
containment devices.• Always follow manufacturer’s
recommendations.• Remember, fill rates will vary.
CHAPTER
7
7.46
Copyright © 2007 Thomson Delmar Learning
Summary
• SCBA is one of the most important PPE items.
• Both SCBA and the user have limitations.
• Firefighters must be familiar and comfortable with use of SCBA.
• Firefighters need to be proficient in the proper and rapid donning of SCBA