Page 1: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

c a n b e r r a | s y d n e y | b r i s b a n e

Job Title:

Job Location:

Client:

Reference #:

SELLICK CONSULTANTS PTY LTD

paul
Typewritten Text
TRAFFIC AND PARKING ASSESSMENT
paul
Typewritten Text
MULTI UNIT DEVELOPMENT
paul
Typewritten Text
BLOCKS 6-9 SECTION 44 LYONS
paul
Typewritten Text
PHILIP LEESON ARCHITECTS
paul
Typewritten Text
180620
Page 2: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Project Details For the Attention of: Philip Leeson Architects

4/9 McKay Street Turner ACT 2612

Attn: Bryn Challis

Project No: 180620 Sellick Consultants Reference: Blocks 6-9 Section 44 Lyons Sellick Consultants Contact Details Canberra Office: Unit 122, Level 1, Mode 3 24 Lonsdale Street BRADDON ACT 2612 P: 02 6201 0200 F: 02 6247 2203 E: [email protected] Sydney Office: Tenancy 3, 117 Willoughby Road CROWS NEST NSW 2065 PH: 02 6201 0200 E: [email protected] Brisbane Office: Level 15,

111 Eagle Street BRISBANE QLD 4000 PH: 02 6201 0200

E: [email protected]

Revision Issue Prepared By Reviewed By Approved By Date

A Draft Paul Williams Andrew Easey Paul Williams 3/09/2018

B Final Paul Williams Andrew Easey Paul Williams 9/10/2018

Page 3: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

CONTENTS

1.0 INTRODUCTION ........................................................................................................................... 1

3.0 PROPOSED DEVELOPMENT ......................................................................................................... 2

3.1 VEHICLE ACCESS ...................................................................................................................... 2

3.2 PARKING SPACE REQUIREMENTS ............................................................................................ 3

3.2.1 ACCESSIBLE CAR PARKING SPACES ..................................................................................... 3

3.3 CAR PARKING SUPPLY ............................................................................................................. 3

3.4 MOTORCYCLE PARKING SPACES ............................................................................................. 3

3.5 BICYCLE PARKING REQUIREMENTS AND SUPPLY .................................................................... 3

4.0 TRAFFIC ASSESSMENT ................................................................................................................. 5

5.0 CONCLUSION AND RECOMMENDATIONS ................................................................................... 6

APPENDICES Appendix A – Concept Site Plan dated 15/8/2018

Appendix B – Transport Effects Form

Page 4: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Revision 1, ref - 180620

1.0 INTRODUCTION

On behalf of Philip Leeson Architects, Sellick Consultants Pty Ltd has prepared this Transport and Parking Assessment (TPA) for the multi-unit development on Blocks 6-9 Section 44 Lyons (site). The TCCS Guidelines for Transport Impact Assessment (guide) has been acknowledged in this assessment. In accordance with the guide a Transport Effects Form (refer to Appendix B) is applicable to multi-unit sites with less than 60 units. This form has been provided in lieu of a traffic impact assessment. Under the Territory Plan the existing site is a RZ2: Suburban Core in the Woden Valley. It has an area of 3,149m2. The site currently contains 4 sole occupancy dwellings with individual vehicle access provided onto Ulverstone Street.

Page 5: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Revision 1, ref – 180620 Page 2 of 6

2.0 PROPOSED DEVELOPMENT

The proposed development is a multi unit development, which consists of the following:

• 4 x 2 bedroom units;

• 2 x 3 bedroom units;

• Car parking facilities supplying 14 parking spaces

2.1 VEHICLE ACCESS

One vehicle access point onto Ulverstone Street has been proposed to service the development, refer to Figure 1. The proposed verge crossover is 3m wide and internally increases in width to enable cars to pass each other. This arrangement is compliant with AS2890.1 Clause 3.2.1 and the Multi Unit Housing Development Code criteria 75. The width of the driveway is not consistent with a TCCS HD1 driveway design, which has a minimum driveway width of 4.5m. The 4.5m driveway width provides small rigid vehicle’s access to sites. The proposed development’s driveway width and head clearance is restricted by street trees and low hanging branches. Additionally, there is ample on-street parking to accommodate small rigid vehicles. Consequently, the proposed driveway width of 3m is deemed suitable for the proposed development. Figure 1 – Concept Site Plan (Source – Philip Leeson Architects drawing SK01)

Sightlines in accordance with AS2890.1 Figure 3.3 Minimum sight lines for pedestrian safety are provided at each access point. Planter beds adjacent to each driveway are to finish flush with the driveway surface and contain low lying shrubs to enable driver sightlines.

Page 6: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Revision 1, ref – 180620 Page 3 of 6

3.0 PARKING ASSESSMENT

The proposed developments’ car parking requirements/demand and supply is assessed in this section.

3.1 PARKING SPACE REQUIREMENTS

The parking space provision rates given in the Parking and Vehicular Access General Code (PVAGC) that are applicable to the proposed development are summarised in Table 1. Table 1 – Proposed Developments’ Parking Requirements

LAND USE PARKING RATE QUANTITY PARKING

REQUIREMENT

2 bedroom units 1.5 spaces per unit 4 units 6

3 bedroom units 2 spaces per unit 2 units 4

Residential Visitors 1 space per 4 units 6 units 2

TOTAL 12

3.1.1 ACCESSIBLE CAR PARKING SPACES

In accordance with PVAGC, 3% of non-resident parking spaces required are to be provided for people with disabilities. Consequently, one accessible parking space is provided for residential visitors.

3.2 CAR PARKING SUPPLY

The proposed development supplies 14 parking spaces, which exceeds the requirement of PVAGC. Additionally, the immediately adjacent section of Ulverstone Street can accommodate 13 on-street parking spaces to cater for visitor parking. These parking spaces are available for the use of this development and the opposing houses. This effectively supplies an additional 6 visitor parking spaces for the proposed development. Subsequently, the proposed developments’ parking space supply exceeds the minimum requirements of PVAGC.

3.3 MOTORCYCLE PARKING SPACES

PVAGC indicates that three motorcycle parking spaces are required per 100 parking spaces. The majority of proposed car parking facilities will be secured/designated for residents, who do not require additional motorcycle parking spaces. There is readily available hardstand available for visitors to park their motorcycle’s when visiting a resident. Consequently, a designated motorcycle parking space is deemed unnecessary.

3.4 BICYCLE PARKING REQUIREMENTS AND SUPPLY

The bicycle parking general code (BPGC) indicates the proposed development requires the following number of bicycle parking spaces:

Page 7: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Revision 1, ref – 180620 Page 4 of 6

• Residences – one bicycle parking space per unit, which may be contained in a secure storage

space 1.8m long, 0.7m wide and 1.1m high;

• Resident visitors – one class 3 bicycle parking space;

The proposed development’s residences contain secure coutyards, external storage cages and carports. These facilities supply adequate space to accommodate resident bicycle parking. The residents’ garages and courtyards are also readily available to accommodate visitor bicycle parking. Consequently, the single class 3 bicycle parking space is not required.

Page 8: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Revision 1, ref – 180620 Page 5 of 6

4.0 TRAFFIC ASSESSMENT

Refer to Transport Effects Form in Appendix B.

Page 9: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Revision 1, ref – 180620 Page 6 of 6

5.0 CONCLUSION AND RECOMMENDATIONS

Based on this assessment the following is concluded:

• The car parking space supply complies with PVAGC;

• The supply of parking spaces for people with disabilities complies with PVAGC;

• There is space available to accommodate visitor motorcycle and bicycle parking space

• Allowing for the existing development’s traffic generation, the proposed development will

have a net generation of 4 vehicles per day.

• The proposed development traffic generation will have minimal impact on the local road

network.

Based on the conclusions above Sellick Consultants recommends approval of the proposed development application with respect to parking and traffic.

Page 10: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Revision 1, ref - 180620

APPENDIX A.

Page 11: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Issue Details Date Drawn Approved1 Consultation 12/06/2018 BC PL

1086420 20

2 Consultation 17/07/2018 BC PL3 Consultation 15/08/2018 BC PL Site Plan SK01

SCALE:FILE:PROJECT NO:

1837 Lyons ATSI Housing C2.pln1837

Drawing No.4/9 McKay Street Turner ACT 2612P 6295 3311 E inf [email protected]

PHILIP LEESON ARCHITECTS Proposed Multi-Unit Housing

CLIENT:

PROJECT:

Blocks 6, 7, 8 & 9, Section 44, 23-29 Ulverstone Street LYONS ACTSITE:

Housing ACT AS SHOWN @ A1

/Volumes/Server/AA Current Projects/2018 Projects/1837 Lyons ATSI Housing/3 CAD/1 Sketch Plans/1837 Lyons ATSI Housing C2.pln

CONCEPT 2

3 150.01 m2

FFL 598 780

FFL 598 822

FFL 597 843

FFL 598 792

FFL 598 080

FFL 5

98 47

0

113.05 m2

113.05 m2

113.05 m2

135.72 m2

135.72 m2

6.86 m26.86 m2

6.86 m2

6.86 m2

113.05 m2

6.19 m26.19 m2

Wheelchair accessible path

Letterbox andsign wall

Wheelchair ramp Wheelchair accessible path

Fence on top ofretaining wall

Retaining wall

Retaining wall

Retaining wall

Retaining wall

PP PP

PP

PP

607.89

607.62

607.49

606.66

606.90 606.61

606.25

606.87

605.94

596 596597

597

598

598

599

599

600

600

36~48'40" 10.48

36~48'40" 28.105

R54.865 A16.765217~44'40" C16.70

194~40'3.655

R54.865 A13.715 201~49'40"

C13.68194~40' 28.955

310~

57'30

" 42.4

9

DRIPL

INE

EL SU

PPLY

EASE

MENT

1.52

WIDE

14~40' 10.135 14~40' 19.505 14~40' 16.68

EL SUPPLY EASEMENT 1.52 WIDE

194~40' 19.505

ULVERSTONE STREET

136~

36'25

"

37.4

75

RegulatedTree

RegulatedTree

Clothes

BBQ

BBQ

BBQ

BBQ

BBQ

P.P.O.S.

P.P.O.S. P.P.O.S.Unit 32-Bedroom

P.P.O.S.

P.P.O.S.

Clothes

Unit 12-Bedroom

Unit 22-Bedroom

Unit 42-Bedroom

Unit 53-Bedroom

Whe

elcha

irLo

adin

g Zo

ne

Clothes Clothes

BBQ

Cloth

es

Cloth

es

P.P.O.S.

Unit 63-Bedroom

N

Site Plan1:200

Page 12: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Revision 1, ref - 180620

APPENDIX B

Page 13: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

ACT Transport Canberra

and City Services

TRANSPORT EFFECTS FORM

Provide the Proposal Number to which this application relates:

20

Development/Site Location Details

If more than one lease/site, attach the following detailed for each lease/site

Block 6-9

Section 44 Unit (if applicable)

Suburb Lyons

District Woden Valley

Street Number

Street name Ulverstone St

Postcode 2606

Attach a detailed site plan that includes the following as a minimum (if a site plan has previously been submitted for the development application that includes all necessary information, attach that plan).

• Access / egress points for private vehicles, pedestrians, cyclists, service / delivery vehicles;

• Location of the building(s);

• Parking lot layout including dimensions of parking stalls and widths of aisles;

• Widths of vehicle access / egress points; and

• Adjacent streets (labelled).

Page 14: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Roads ACT TCCS Traffic Signal Section Office of Transport

Fully describe the proposed development (or reference the Development Application)

The proposed multi-unit development replaces four single dwelling blocks with four 2-bedroom units and two 3-bedroom units.

Scale of Development (see TIA Guide, Section 4.1)

Proposed Land Use or Activity

Multi unit housing

Scale/Size 6 units

If appropriate, further describe the scale/size of the development:

Describe the operating hours

The development will be in continuous operation with tidal traffic volumes likely being generated in the AM and PM peak hour periods.

Existing Use of the Site (pre-development):

4 single dwelling blocks are contained within the site.

Expected proposed development completion or occupancy:

Page 15: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Roads ACT TCCS Traffic Signal Section Office of Transport

Surrounding Road Network (see TIA Guide, Section 4.2)

Complete for each road adjoining the development site:

Road Name Ulverstone Street Through Lanes Right Turn Lanes Left Turn Lanes

Number of Lanes 1

Distance to Nearest Access

75m Distance to Nearest Intersection

75m

Road Name

Through Lanes Right Turn Lanes Left Turn Lanes

Number of Lanes

Distance to Nearest Access

Distance to Nearest Intersection

Road Name

Through Lanes Right Turn Lanes Left Turn Lanes

Number of Lanes

Distance to Nearest Access

Distance to Nearest Intersection

Road Name

Through Lanes Right Turn Lanes Left Turn Lanes

Number of Lanes

Distance to Nearest Access

Distance to Nearest Intersection

Page 16: SELLICK CONSULTANTS PTY LTD TRAFFIC AND PARKING …€¦ · The proposed development is a multi unit development, which consists of the following: • 4 x 2 bedroom units; • 2 x

Roads ACT TCCS Traffic Signal Section Office of Transport

Traffic Distribution (see TIA Guide, Section 4.3)

Please attach a locality plan with trip distribution estimates annotated on the plan. Please describe how the trip distributed estimates were derived:

Based on the traffic generation rates in the Estate Development Code the proposed development will generate 36 movements per day. Also based on the EDC the existing development generates 32 movements per day. Consequently, the proposed development will have a net generation of 4 vehicle movements per day. This small volume will not have a noticeable impact to the local road network.