semaphore indicator - tms · semaphore indicator * please refer to page 6 for the rating compliant...
TRANSCRIPT
Semaphore Indicator
notice!
Total Metering Solution Sdn Bhd22&22A, Jalan Anggerik Vanilla 31/93Kota Kemuning, 40460 Shah AlamSelangorPhone: +603-51220029, Fax: +603-51220079Email: [email protected]
SPS-TYPE
SPECIFICATIONS (RATINGS, PERFORMANCE)
Rated insulation voltage(Ui)
Rated operational voltage (Ui)
Voltage fluctuation range
Rated operational current (Ie)
Insulation resistance
Power-frequency withstand voltage
Inpulse withstand voltage
Shock resistance
Durability
Degree of prolection
Operating temperature
Storage temperature
Relative humidity
Altitude
Compatible copper conductors
Compatible terminal
Mounting plate thickness
Weight
TypeSpecification
AC,DC250V
DC24V, 30V, 48V, 100/110 V, 125 V, 200/220 V
±15%(24 V, 30V,48 V, 200/220 V)
-20 to 30%(100/110 V, 125V )
11 mA max.
1,000 M over
2,000 V AC/min.
±4,500 V, 3 times for each pole (1.2/50 µs)
490m/s2 6 directions 3 times
Over 10 thousand cycles
IP52
−20 to 60°C
−30 to 75°C
45 to 85%
Max 2,000 m
AWG20 to14
M3.5 x 8 with square washer
1 to 6 mm
Approximately 30 g
1
Semaphore Indicator
* Please refer to page 6 for the rating compliant with the international standard.
FEATURES
Customer requirements for size and weight reductions are completely satisfied by the equipment’s compact design.
TÜV approved International Standard products conforming to EN60947-1 and EN60947-5-1.(The TÜV and CE marks are affixed on the main body of the product.)
Option for a round or square external shape is available. Distinct display of each optional shape completes the sophisticated panel design.
Visual-apparent circuit display makes it possible to verify the circuit connection accurately and instantly.
A superior energy-efficient design has achieved further reductions of power consumption to one fourth the previous model.
Standard terminal cover for the live parts ensures a higher level of safety.
Note: Rated operationl current/24VDC(Previous model) SPR/L model: Approx. 37 mA(New model) SPSR/L model: Approx. 9 mA
2
97 mm (screw type: 100)
(Previous model)SPR-3
About 125 g
SPSR-3About 30 g
(Conceptual drawing)
85 mm
Compatible with at maximum an AWG14 power cable (equivalent to 2.5 mm2).
3
STANDARD PRODUCTS
Panel cut dimensions
30
(80)
(85)6
30
20.5+0.5-0
40
40
20.5+0.5-0
CXL-CV
SPS-Q
CXL-CV
SPS-Q
SPS-TYPESemaphore Indicator
Applicable accessories
Terminal cover
Tightening tool
Panel cut dimensions Applicable accessories
Terminal cover
Tightening tool
4
TOP
25
19
6TOP
32
26
8.5
(80)
(85)
(Minimum mounting pith)
(Minimum mounting pith)
(CXL-CV)
Mounting panel t=1~6
Type:NP
M 3.5 x 8 screw
(Up to 2.5mm2 wiring)
NutTerminal cover
Packing
(CXL-CV)
Mounting panel t=1~6
Type:NP
M 3.5 x 8 screw
(Up to 2.5mm2 wiring)
NutTerminal cover
Packing
4
4TOP
19
7
28
28
(80)
(85)
6 TOP
26
9.5
(80)
(85)
35
35
(CXL-CV)
Mounting panel t=1~6
Type:NP
M 3.5 x 8 screw
(Up to 2.5mm2 wiring)
NutTerminal cover
Packing
STANDARD PRODUCTS
30
30
20.5+0.5-0
40
40
20.5+0.5-0
Panel cut dimensions(Minimum mounting pith)
Panel cut dimensions(Minimum mounting pith)
(CXL-CV)
Mounting pane t=1~6
Type:NP
M 3.5 x 8 screw
(Up to 2.5mm2 wiring)
NutTerminal cover
Packing
CXL-CV
SPS-Q
Applicable accessories
Terminal cover
Tightening tool
CXL-CV
SPS-Q
Applicable accessories
Terminal cover
Tightening tool
5
SPS-TYPESemaphore Indicator
ACCESSORIES
Tightening tool
SPS-QCXL-CV
Terminal cover (Order unit : 10)
Note: The terminal cover is supplied with main unit.
DC024
DC030
DC048
DC110
DC125
DC220
DC24V
DC30V
DC48V
DC100/110V
DC125V
DC200/220V
Voltage
ORDERING METHODRefer to the following type code.
Surface dimensions
Surface dimensions
Basic type Power supply voltage
Product coding
SPSR-20S-DC110-BBA
2
3
25mm
28mm
32mm
35mm
Terminal screw
Code
Code
Face size
4mm
6mm
Indicating flag width
R
L
Round type
Square type
Code Dimensions
0
1
2
OFF ON No voltage
Terminal
Indicating flag
S
Code Type
Flag color
Black(N1.5)
Frame color
B
Code Color
Black(N1.5)B
CodeCode Color
Mounting hole
No Code
A
20.5mm
22.3mm
Code Mounting hole dimention
6
MOVEMENT AND CIRCUIT
1 2
3
DC(P)
(N)
DC(P)
(N)
Off On
OFF
1 2
3
DC(P)
(N)
ON
1 2
3
DC(P)
(N)
No voltage
R R
R
3
1 2
SD SD
Semaphore
Indication diagram Circuit diagram
CoilCoil
Rating compliant with the international standard (EN60947/IEC60947) as of June 2004
(1) Basic rated values and utilization
Item
Rated operational voltages
Rated operational currents
Rated insulation voltage
IP code
No.
1
2
3
4
Note: The above items have been certified according to TÜV. Please contact us for more details.
Basic rated values and utilization
DC24V, 48V, 100/110V, 125V, 200/220V
11mA max.
250V
IP 52
IEC standard
IEC60947-5-1; 5.1-d
IEC60947-5-1; 5.1-e
IEC60947-5-1; 5.1-f
IEC60947-5-1; 5.1-I
(2) Normal service conditions
Item
Ambient air temperature
Altitude
Atomspheric conditions
Conditions during transportand storage
Mounting hole
Rangr of panel thickness
Minimum mounting pitch
No.
1
2
3
4
5
6
7
(3) Basic rated values and utilization
Item
Connecting capacity
Dielectric properties
Durability
No.
1
2
3
Basic rated values and utilization
Stranded wire : AWG20(max 2pear)
With ring lug : AWG14-20(max 2pear)
Power frequency withstand voltage : AC2000V/1minute
Mechanical durability : 100,000times
EC standard
IEC60947-1; 7.1.7
IEC60947-1; AnnexD
IEC60947-5-1; 7.2.3
IEC60947-5-1; AnnexC
Normal service conditions
−5°C~+40°C
2,000m max.
Humidity : max 90% at +20°C, 50% at +40°CMicro-environment : Pollution degree 3
Between −25°C and +55°C, for short periods notexceeding 24h, up to +70°C
see 3-4page
1~6mm
30mm
40mm
SPSR/L-2
SPSR/L-3
EC standard
IEC60947-1; 6.1.1
IEC60947-1; 6.1.2
IEC60947-1; 6.1.3
IEC60947-1; 6.2
IEC60947-5-1; 6.3.1
IEC60947-5-1; 6.3.1.2
IEC60947-5-1; 6.3.1.3