sensing the future - quality control services: home … · thermo orion’s expertise in titration...
TRANSCRIPT
Customer Service and Support 8002251480 - 9782326015 (fax)
Other Innovative ProductsSensing the Future
ROSStrade pH Electrodesbull Fastest Accurate Reproducible Results at
Varying Temperaturesbull Unique Nonmetallic Reference Does Not
Contaminate Samples
ionplusreg Sure-Flowreg CombinationISE Electrodesbull Stable and Reproducible for Low-Levels and Small Samplesbull Reduced Analysis Time and Maintenance Time
Specialty Titration Electrodesbull For Karl Fischer Titrationsbull For Redox and Surfactant ApplicationsPurchase a 960 Module and Save $200000
Take Advantage of Untapped Potential
bull Increase Accuracy and Precision by Automating your Current Electrode Analysis
bull Save Time by Letting the Instrument Automate the Analysis
bull Expand your Current Measurement Capabilities to Do AutomatedIncremental ISE and Titration Techniques
bull Have the Ability to Expand your Laboratoryrsquos Sample Throughput by Addingan AS3000 Autosampler
New Turn-key ISE Application Kitsbull ISE Meter Electrode and Solutionsbull Fluoride Chloride and Sodium Measurements
Turn your Ion Analyzerinto a Titrator
Model 940
Model 960
Limited time offer some restrictions apply
SAVE $200000
Register to Download our NEW On-Line Titration Catalog at wwwthermoorioncom
Table of Contents
Customer Service and Support 8002251480 - 9782326015 (fax)
Introduction |pg 5
Applications |pg 6
Model 960 Titrator PLUSreg |pg 7
AS3000 New Series Autosamplers |pg 8
Model 950 Fast QCtrade Titrator |pg 9
Model 930 Ionalyzertrade System |pg 10
Techniques |pg 11Endpoint Analysis KAPtrade Analysis GAPtrade Analysis Assist Analysis
Specifications |pg 12Model 960 950 amp 930
Accessories amp Consumables |pg 13Description of Accessories Consumables Printers
Printer Consumables Cables EPROMS amp Software
Accessories amp Cables |pg 22Description of Karl Fischer Moisture VaporizerAccessory Balance amp Printer Cables
Electrodes amp Solutions |pg 15ATC Probes Ammonia Analysis Calcium Analysis ChlorideChloride Analysis Cupric Analysis Fluoride Analysis
Lead Analysis Nitrate Analysis pH Analysis Potassium Analysis pg 16
Reference Electrodes Sodium Analysis SurfactantAnalysis Special Tests amp Analyses pg 17
TURBO2reg Blending VolumetricKarl Fischer Titrator |pg 18
Model AF8 Volumetric Karl Fischer Titrator |pg 19
Model AF7 Coulometric Karl Fischer Titrator |pg 20
Model AF7LC Coulometric Karl Fischer Titrator |pg 20
Accessories amp Consumables |pg 21Description of Instruments Model AF7 Accessories ampConsumables Model AF7LC Accessories amp Consumables
Specifications|pg 23Model TURBO2 AF8 AF7 amp AF7LC
Terms and Conditions |pg 24
Warranty |pg 25
Cross References |pg 26
Introduction
Thermo Orion offers a wide variety of innovative titration and automation productsThermo Orionrsquos expertise in titration began with the automation of Ion Selective Electrode(ISE) analyses Over time it expanded to include an entire product line dedicated topotentiometric analyses as well as a full line of Karl Fischer Moisture Analysis TitratorsThrough continued research and development Thermo Orion is always expanding intonew technologies to ldquoSense the Futurerdquo
Potentiometric workstations and titration systems make analyses quick easy andreproducibly accurate Whether the analysis is surfactants in shampoo fluoride indrinking water or Vitamin C in juices Thermo Orion has the system to automate your measurements
Thermo Orion has an automated Karl Fischer Titrator to accurately measure moisture in most any type of sample Numerous applications have been developed for a variety of industries including the agricultural chemical pharmaceutical cosmetic and food industries
A wide range of pH ISE and Specialty titration electrodes are available including thesurfactant electrode to test for anionic cationic and nonionic surfactants
The New AS3000 Series Autosampler is compatible with the Model 960 TitratorPLUSregsbquo as well as Models 162A 535A 550A 555A and 862A benchtop meters Increase lab productivity by automating sample preparation and analyses with an AS3000 Autosampler
Model 960
TURBO2reg
pH and ISE Electrodes
AS3000 Series Autosampler
Customer Service and Support 8002251480 - 9782326015 (fax)
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | Turbo2 | AF8 | AF7AF7LC | 5
Karl Fischer Moisture Analyses Log
Advil Tablets by TURBO2 Blending Volumetric KF KF1523Chewing Gum by TURBO2 Blending Volumetric KF KF1286Face Lotion by TURBO2 Blending Volumetric KF KF1193Freeze-Dried Foods by TURBO2 Blending Volumetric KF KF1409Ink-Printing by TURBO2 Blending Volumetric KF KF1013Pasta by TURBO2 Blending Volumetric KF KF1039Sugar by TURBO2 Blending Volumetric KF KF1565Brake Fluid by AF8 Volumetric KF KF1088Cosmetics (Alcohol) by AF8 Volumetric KF KF1574Insulin Standard by AF8 Volumetric KF KF1405Kerosene by AF8 Volumetric KF KF1059Textiles ndash Wool by AF8 Volumetric KF KF1246Toothpaste by AF8 Volumetric KF KF1095Antifreeze by AF7 Coulometric KF Moisture Titrator KF1466Oil-Mineral by AF7 Coulometric KF Moisture Titrator KF1224Diesel by AF7LC KF1259
Potentiometric Analyses Log
Free Fatty Acid in Animal FatRefined Vegetable 638ACalcium Carbonate in Acid Relief Tablets 646ASodium in Bacon 505Sodium Chloride in Barbecue Sauce 296BSodium in Beer 123Anionic surfactant in bath soap 453Chloride in Biscuit and Gravy mix 412CChlorine in Bleach 468DSodium in Butter 630BChloride in Cat Food 541CSurfactant in Detergent 438Fluoride in Ground Water 586Hydrogen Peroxide in Hair Permanents 28Vitamin C in Infant Formula 327AZinc in Motor Oils 133Anionic Surfactant in Shampoo 658ANitrate in Soil 284A
The Thermo Orion Applications Lab makes the difference when purchasing titration equipment Thermo Orion has hundreds ofapplication notes providing valuable methods and performance information for all of our titration equipment In addition to theexisting database of application notes the Application Lab will analyze customer samples for either method development or testvalidation procedures The Applications Lab is utilized in conjunction with the sale of a Thermo Orion titration unit Application development may be performed on any of Thermo Orionrsquos potentiometric or Karl Fischer Titrators
Listed below are just some of Thermo Orions titration application notesExamples of Applications
Register at wwwthermoorioncom to view the entire index of Thermo Orion Titration application notes
Applications
FoodConfectionaries
CosmeticsPharmaceuticals
WaterWaste Water
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | Turbo2 | AF8 | AF7AF7LC | 6
Customer Service and Support 8002251480 - 9782326015 (fax)
Titrator PLUSreg
bull Highly Versatile - analytical instrument with complete automation capability
bull 12 Preprogrammed Techniques - automate titrations pH and direct ion measurement
bull Potentiometric Titrations - including acidbase redox precipitation and complexometric
bull Simple - ldquoYESrdquo and ldquoNOrdquo operating commands
bull Method Memory - store up to 20 methods
bull Data Collection Software - collect view store and print data
bull AssuredAccuracytrade - titrant delivery with gravimetric calibration
bull Karl Fischer Accessory - for low throughput moisture analysis
Ideally suited for dedicated routine measurements the Model 960 is intended foruse in laboratories where automation is needed to overcome problems of samplethroughput or analytical complexity What differentiates the Model 960 from othersingle parameter analyzers or automatic titrators is its versatility Not only can it beused for performing classical titrations it can also automate the measurement ofany species measurable by ion selective and pH electrodes All of the operatingprocedures appear on the instrumentrsquos display in the form of easy-to-understandquestions Using the Model 960 improves precision and response time for electrodemeasurements Because the analysis is automated each step is carried outconsistently mdash time after time operator to operator Quick release fittings on thebottles make it easy to disconnect one bottle and connect another Therersquos no needto stock spare burettes for fast reagent changes The dispenser is a rotaryreciprocating pump Unlike an automatic burette the pump has no valves to switchfor refilling Also there is no dead volume making changing reagents easy and fastTypical problems encountered when doing manual analyses are virtually eliminatedmaking ISE technology better suited for a busy day of testing Higher levels of
automation can be achieved by adding a Model 960ADWorkstation as an auxiliary reagent dispenser The Model960AD is available in two versions for use with or without theAS3000 Series Autosampler You can integrate up to eight workstations and an autosampler into one system formaximum versatility For routine measurements a short form printout is available All pertinent GLP information isprovided including sample ID electrode time date and theresult The Model 960 can calculate results in 22 units ofmeasurement In addition diagnostic error messages may be printed to provide troubleshooting information such asexcessive electrode drift or matrix effect For methoddevelopment a long form printout is available where raw data is printed including volume of reagent millivolts timeelapsed a plot of the curves where appropriate and method parameters
Cat No
096000
096002
Description of Instruments
960 Titrator PLUS System complete with EA 940 pHISE Meter Model 960 Titrator Plus Module Includes Base assembly tower assembly electrodeholder stirrer two dispenser probes anti-diffusion dispenser probe with six tips tubing kit calibration kit cable (Models 960 and EA 940) referencetablet two working solution bottles two dip tubes and caps line cords and instruction manual User selectable power requirement 100115220240V plusmn10
960 Titrator PLUS Module (Module does not include EA 940) Includes Base assembly tower assembly electrode holder stirrer two dispenser probesone anti-diffusion dispenser probe with six tips tubing kit calibration kit cable (Models 960 EA 940) reference tablet three speed number note padstwo working solution bottles two dip tubes and caps PROM upgrade kit (to update software in EA 940) line cord US standard connector andinstruction manual User selectable power requirement 100115220240 plusmn10
Model 960
Techniques Specifications Accessories amp Consumables Electrodes amp Solutions
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 7
Customer Service and Support 8002251480 - 9782326015 (fax)
bull AS3000 Series Autosamplers - for use with the Model 960 TitratorPLUSreg
bull Enhance Lab Productivity - automate Sample Preparation Calibrations and Standardizations
bull Increased Flexibility - interchangeable beaker racks and probe holders
bull Three Rack Sizes - (45) 50 mL (28) 150 mL or (18) 250 mL beakers
bull Quality Control - up to five rinse beakers to clean the electrodes between analyses
The new AS3000 XYZ Autosamplers are designed for use with the Model 960 TitratorPLUS Thermo Orion offers a choice in autosamplers withmultiple rack configurations to provide flexibility for high sample throughput Runtitrations or other pHISE techniques with the use of the new AS3000 seriesAutosampler overnight Additionally the probe arm assembly moves along the
X Y and Z-axes at speeds from 0 to 35 inches per second withfull control of velocity and acceleration allowing for fastersampling and analyses New Autosampler packages andupgrades from your existing Thermo Orion sample changer are available
Description of Accessories
Model AS3000 Autosampler complete with 45-position rack electrode holder interface cable line cord pkg of (50) 50 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 28-position rack electrode holder interface cable line cord pkg of (50) 150 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 18-position rack electrode holder interface cable line cord pkg of (25) 250 ml plastic beakers and instruction manual 115V220V
Model 960 with AutoSampler 45-Position Rack Designed for 50 mL Beakers (Beakers Included)
Model 960 with AutoSampler 28-Position Rack Designed for 150 mL Beakers (Beakers Included)
Model 960 with AutoSampler 18-Position Rack Designed for 250 mL Beakers (Beakers Included)
45-Position Rack Designed for 50 mL Beakers
28-Position Rack Designed for 150 mL Beakers
18-Position Rack Designed for 250 mL Beakers
Beakers Plastic 50 mL pkg of 50
Beakers Plastic 150 mL pkg of 50 (Replaces Cat No 096S17)
Beakers Plastic 250 mL pkg of 25
Beakers Plastic 45 mL pkg of 50
Cat No
AS3050
AS3150
AS3250
96050A
96150A
96250A
ASR050
ASR150
ASR250
ASB050
ASB150
ASB250
096S22
New Series Autosamplers
AS3000
Feature
50 mL beaker sold with autosampler
150 mL beaker sold with autosampler
250 mL beaker sold with autosampler
Accuracy
Agency Approvals
Environmental Requirements
Paint Color
Description
Polypropylene Chemically resistant 42 mm diameter
Polypropylene Chemically resistant 57 mm diameter
Polypropylene Chemically resistant 68 mm diameter
plusmn 10 mm in all axes
CE UL CSA
5 to 45 degC and 20 to 80 Relative Humidity
Carbide Black
Feature
Programmable Sample Access Area
Foot Print
Height to top of Z-axis
Sample Capacity
Model AS3050
Model AS3150
Model AS3250
Computer Interface
Power Voltage
Description
187 X 70 X 475 inches (W X D X H)
2325X145X1575 inches (W X D X H)
59X37X40 cm
45 50 mL glass or plastic beaker
28 150 mL glass or plastic beaker
18 250 mL glass or plastic beaker
RS232
90-240 Vac 5060 Hz
Accessories amp Consumables
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 8
Customer Service and Support 8002251480 - 9782326015 (fax)
bull Economical Automatic Titrator - fits any budget
bull Automates - routine titrations can be done easily
bull Modular Design ndash the compact design allows flexibility and versatility
bull Superior Features - incorporates premium ROSStrade pH electrode technology
bull Printer Options - provide comprehensive record of results and methods
Cat No
095000
095001
095002
095003
095004
Description of Instruments
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSStrade Sure-Flowreg pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
950 FAST QC Titrator without line cord Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional and manual
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
Note To use with an external printer order 950DPU OR 950EPN splitter cables
The Model 950 incorporates the superior features of the patented ROSS pHtechnology into an economical yet versatile potentiometric titrator The Model 950performs AcidBase titrations including non-aqueous samples oxidation-reductionprecipitation and complexometric titrations using ion selective electrodes Automateall routine manual color end-point titrations with the Model 950 preset end-pointtechnique The Model 950 preset technique can titrate to one or two preset pH ormillivolt values to measure P amp M alkalinity of water or acidity of carbonatedbeverages The Model 950 first derivative technique offers titration to one or multipleinflection points for many analyses for example chloride in food ingredients copperin a plating bath or TAN and TBN of the petroleum products The Titrant and theentire system can be standardized automatically against an accurately weighedknown NIST or other national standards using the standardize system technique
This basic titrator is extremely simple to use just press a singlebutton to start the titration Automatic pH calibration menuleads you to perform one or two point calibration On-boardmemory stores up to 10 methods that can be recalled at thepush of a button Methods can be locked to safeguardaccidental deletion Unique to Thermo Orion titrators theAssuredAccuracytrade feature allows the gravimetric calibration of the entire dispensing system making it easy to meet ISO 9000 and GLP requirements Simply add a secondworkstation to expand your Model 950 titration capabilitiesand enhance your labrsquos productivity
Fast QCtrade Titrator
Model 950
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 9
Customer Service and Support 8002251480 - 9782326015 (fax)
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Note To use with an external printer order 950DPU OR 950EPN splitter cables
bull Ion Measurement - made easier through automation
bull Simple - self-calibrating one beaker analysis
bull Workstation Design - reduces chemical usage and reagent handling
bull KAPtrade Analysis ndash one Beaker Analysis
bull Customize - with any ionplusreg combination ion selective electrode
The Model 930 Ionalyzer System and ionplus electrodes provide fast reliable ionmeasurement with an easy-to-use precise analysis technique The exclusive KAPtrade
Analysis techniques ensure dependable performance even with the most difficultsamples Design features provide a saving in time and cost per analysis Automatedreagent handling reduces time spent preparing samples and produces less reagentwaste The Model 930 Ionalyzer workstation also holds electrodes and stirs thesample during analysis Using advanced ionplus electrodes (with Sure-Flowreg
references) measure even the dirtiest samples without additional filtration ordistillation steps Save time and money measuring such species as cyanide inplating solutions and sulfide in pulping liquors Customize to meet your specializedneeds calculate results in your choice of concentration units and report all results onthe integrated or external printer With dual channel inputs you can add anadditional workstation to expand your analysis capacity Store up to ten differentmethods for maximum productivity The Model 930 Ionalyzer also measures pHproviding additional measurement choice For example the Model 930 is ideal forboth ammonia and pH measurements in effluent KAP Analysis techniques improve
performance by adding small aliquots of a standard to thesample This self-calibrating technique performs bothelectrode calibration and sample measurement in one beakerKAP Analysis minimizes errors due to complexing agents orcomplicated sample backgrounds Choose between singleknown addition for simple measurements or double ormultiple known addition for samples with complexbackgrounds Quickly measure compounds such as chloridein food in one beaker without hazardous metal titration Verifyanalysis with spike recovery automatically performed in themultiple known addition technique Also automate other directmeasurements with the ACCUreadtrade or serial calibrationtechniques performing an entire multipoint calibration in onebeaker Providing calibration measurement and validation ofresults automatically the Model 930 Ionalyzer improvesspeed and accuracy and lowers cost per analysis
Cat No
093000
093001
093002
093003
093004
Description of Instruments
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 220V 60Hz
930 Ionalyzer without line cord Includes workstation control unit printer printer paper cables tubing instructional and manual
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 220V 60Hz
Ionalyzerreg System
Model 930
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 10
Customer Service and Support 8002251480 - 9782326015 (fax)
The chart below describes the various techniques available on Thermo Orionrsquos titrators and dispensing workstations and when they are recommended
Endpoint Analysis
First Derivative(For Model 960and Model 950)
Second Derivative(For Model 960)
Present Endpoint(For Model 960950)
KAPtrade Analysis
Multiple Known Addition(For Model 960and Model 930)
Multiple Known Subtraction(For Model 960)
Multiple Analate Addition(For Model 960)
Serial Calibration(For Model 960 930)
GAPtrade Analysis
Gran Function(For Model 960)
Gran Predict(For Model 960)
Assist Analysis
Standardize System(For Model 960)
HELP Analysis (For Model 960)
pH Read(For Model 960)
Description
Automated titration technique which calculates endpoints from the first derivative of the titration curve
Similar to first derivative but endpoints arecalculated from second derivative
Allows titration to proceed to one or two preset mV or pH values
Performs calibration and calculates sampleconcentration by adding aliquots of standard to sample
Performs calibration and calculates sampleconcentration by adding aliquots of reagentwhich reacts with sample species
Performs calibration and calculates sampleconcentration by adding aliquots of sample to astandard solution
Generates calibration curve by adding aliquotsof standard to a beaker of water and ISA
Similar to first derivative but Gran Functionsapplied to determine equivalence points
Similar to Gran Function but looks at data onone side of equivalence point only
Standardizes entire system (electrodeselectronics dispenser titrant)
Recommends the best method by adding aliquots of reagent to sample and analyzing data
For accurate pH measurements and direct ion read
When Recommended
bull Routine potentiometric titrations bull Determine poorly defined and
multiple endpoints
bull When required by industry standardsbull Eliminates false endpoint detection
bull P amp M alkalinity of water and wastewaterbull Titrations with no clearly defined endpointbull When required by industry standards
bull Measure nontitratable species ie NA+ K+ NO3
- NH3bull Complex sample matrixbull More precision required than
Standard calibration
bull No stable standard solution for ion of interest ie sulfide
bull Use for direct read of ions (calibrate and read series of samples)
bull Concentrated samplebull Viscous samples
bull Low level measurementsbull Checking electrode performance
bull Titrations with poor endpointbull Titrations with two endpointsbull Titrations with asymmetric curves
bull Slow reactionsbull Speed requiredbull Low level titrations ie Cl-
bull Highest system accuracy required
bull When unsure of what technique or measurement parameters to use
bull Automation of pH or direct ion read Can beused on autosampler
Advantage
bull Precisionbull No ambiguity in location of
endpoints
bull Precision
bull No interference from color or turbidity
bull No need for independent calibration or recalibration
bull Matrix effects minimizedbull Recovery test performed with
every sample
bull Faster than conventional titrationbull Uses less reagent than
conventional titration
bull Sample automatically diluted as part of analysis
bull Sample can be added from automatic pipet
bull Defines non-linear portion of calibration curve
bull Eliminates need to prepare standards
bull Accuracy
bull Speedbull Less reagent consumption
bull One-step standardization of all system components
bull Optimizes method
bull Automation accuracy
TechniquesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 11
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
Output
mV
Concentration
pH Range
Temperature
Power RequirementVoltageFrequency
Titration Modes
Methods Saved
Display
Variable Speed Stirring Paddle
Input
DimensionsHeightWidthDepth
CaseSplash and Chemical Resistant
Environmental Requirements5 to 45 degC and 5 to 85relative humidity
Autosampler Option
Agency Approvals
Ordering Information110 V220 VWithout Line CordWithout Printer 110 VWithout Printer 220 V960 Module
Model 960
EA 940 RS232 recorder Karl Fischer 4RS232 ports for connection to EA 940 printercomputer and balance one 15-pin parallel port
-160000 to 160000 mV
00001 to 99999
-2000 to 19999
-50 to 1050 ˚C
110120220240 VAC5060 Hz
All 930 and 950 OptionsSecond Derivative TitrationSingle Known SubtractionDouble Known SubtractionMultiple Known SubtractionMultiple Analate AdditionGran FunctionGran PredictStandardize SystemHelp AnalysispH Read
Up to Twenty
Custom color vacuumfluorescent with 40 characterprompt line
radic
Two BNC two pin tip dual bananajacks for PT-100 style ATC probe
With Tower16rdquo17rdquo18rdquo
radic
radic
Yes
CE
096000 (110V220V)
096002
Model 950
RS232 recorder Karl Fischer
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 ˚C
9 VDC line converter for110120220240 VAC5060 Hz
Preset pH EndpointPreset mV EndpointFirst Derivative Titration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip ground ATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
095000095001095002095003095004
Model 930
RS232 recorder
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 degC
9 VDC line converter for110120220240 VAC5060 Hz
Single Known AdditionDouble Known AdditionMultiple Known AdditionSerial Calibration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip groundATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
093000093001093002093003093004
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 12
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
0960KF
0607CA
0607CI
096010
096011
096014
096016
096017
096019
096021
096025
096035
096038
096039
096045
910003
0900A0
0900A1
0900A2
0GLP30
0GLP31PRT300
PRT301
55PR40
55PR49
Description of Accessories
Model 960KF Volumetric Karl Fischer Accessory Provides the hardware for performing Karl Fisher Moisture Analysis on the Model 960 Titrator Plus System Includes KF vessel with drain valve vessel top KF electrode (977900) and KF adapter stirrer with long shaft (096019) glass desiccant side arm stopper stand septum Teflon vessel O-ring plugs and O-rings
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 110 V (Use with cable 096050 for Model 960)
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 220 V (Use with cable 096050 for Model 960)
Auxilary Dispenser with tower complete with dispenser probes tubing kit interface cable dispenser base electrode holder stirrer power cord and instruction manual 115230 V
Auxilary Dispenser without tower for use with AS3000 Series Autosampler Includes dispenser probes tubing kit interface cable power cord and instruction manual 115230 V
Description of Consumables
960 Tubing Kit Includes tube and connector for working solution bottle to AUTOdispenser tube and connectors for AUTOdispenser to dispenser probe
Dispenser Probe pkg of 2 and roll of cleaning wire pkg of 1
Anti-Diffusion Dispenser Probe One dispenser probe with six replaceable tips For low-level analyses or dense titrants
Stirrer to fit electrode tower includes stirrer paddle
Stirrer Paddle to fit 096019 pkg of 3
Dip Tube with sealable cap to fit working solution bottle pkg of 6
Gas Absorption Cartridge fits top of working solution bottle Absorbs carbon dioxide and moisture Absorbent not included
AUTOdispenser Calibration Kit includes five sealable plastic vials 8 ml capacity
Bottles 475 ml amber glass for working solution pkg of 12 Req Cat No 096025
Bottles 475 ml translucent plastic for working solution pkg of 12 Req Cat No 096025
Electrode Storage Bottle pkg of 3
Description of Printers
Model 900A Thermal Printer for Models 950930 110V
Model 900A Thermal Printer for Models 950930 220V
Model 900A Thermal Printer for Models 950930 No Adapter 220V
Ink Based GLP Printer for Model 960 includes instruction manual 110 V
Ink Based GLP Printer for Model 960 includes step-down transformer instruction manual 220 V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 110V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 220V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 115 V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 220 V
Continue to next page
Accessories and ConsumablesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 13
Customer Service and Support 8002251480 - 9782326015 (fax)
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Table of Contents
Customer Service and Support 8002251480 - 9782326015 (fax)
Introduction |pg 5
Applications |pg 6
Model 960 Titrator PLUSreg |pg 7
AS3000 New Series Autosamplers |pg 8
Model 950 Fast QCtrade Titrator |pg 9
Model 930 Ionalyzertrade System |pg 10
Techniques |pg 11Endpoint Analysis KAPtrade Analysis GAPtrade Analysis Assist Analysis
Specifications |pg 12Model 960 950 amp 930
Accessories amp Consumables |pg 13Description of Accessories Consumables Printers
Printer Consumables Cables EPROMS amp Software
Accessories amp Cables |pg 22Description of Karl Fischer Moisture VaporizerAccessory Balance amp Printer Cables
Electrodes amp Solutions |pg 15ATC Probes Ammonia Analysis Calcium Analysis ChlorideChloride Analysis Cupric Analysis Fluoride Analysis
Lead Analysis Nitrate Analysis pH Analysis Potassium Analysis pg 16
Reference Electrodes Sodium Analysis SurfactantAnalysis Special Tests amp Analyses pg 17
TURBO2reg Blending VolumetricKarl Fischer Titrator |pg 18
Model AF8 Volumetric Karl Fischer Titrator |pg 19
Model AF7 Coulometric Karl Fischer Titrator |pg 20
Model AF7LC Coulometric Karl Fischer Titrator |pg 20
Accessories amp Consumables |pg 21Description of Instruments Model AF7 Accessories ampConsumables Model AF7LC Accessories amp Consumables
Specifications|pg 23Model TURBO2 AF8 AF7 amp AF7LC
Terms and Conditions |pg 24
Warranty |pg 25
Cross References |pg 26
Introduction
Thermo Orion offers a wide variety of innovative titration and automation productsThermo Orionrsquos expertise in titration began with the automation of Ion Selective Electrode(ISE) analyses Over time it expanded to include an entire product line dedicated topotentiometric analyses as well as a full line of Karl Fischer Moisture Analysis TitratorsThrough continued research and development Thermo Orion is always expanding intonew technologies to ldquoSense the Futurerdquo
Potentiometric workstations and titration systems make analyses quick easy andreproducibly accurate Whether the analysis is surfactants in shampoo fluoride indrinking water or Vitamin C in juices Thermo Orion has the system to automate your measurements
Thermo Orion has an automated Karl Fischer Titrator to accurately measure moisture in most any type of sample Numerous applications have been developed for a variety of industries including the agricultural chemical pharmaceutical cosmetic and food industries
A wide range of pH ISE and Specialty titration electrodes are available including thesurfactant electrode to test for anionic cationic and nonionic surfactants
The New AS3000 Series Autosampler is compatible with the Model 960 TitratorPLUSregsbquo as well as Models 162A 535A 550A 555A and 862A benchtop meters Increase lab productivity by automating sample preparation and analyses with an AS3000 Autosampler
Model 960
TURBO2reg
pH and ISE Electrodes
AS3000 Series Autosampler
Customer Service and Support 8002251480 - 9782326015 (fax)
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | Turbo2 | AF8 | AF7AF7LC | 5
Karl Fischer Moisture Analyses Log
Advil Tablets by TURBO2 Blending Volumetric KF KF1523Chewing Gum by TURBO2 Blending Volumetric KF KF1286Face Lotion by TURBO2 Blending Volumetric KF KF1193Freeze-Dried Foods by TURBO2 Blending Volumetric KF KF1409Ink-Printing by TURBO2 Blending Volumetric KF KF1013Pasta by TURBO2 Blending Volumetric KF KF1039Sugar by TURBO2 Blending Volumetric KF KF1565Brake Fluid by AF8 Volumetric KF KF1088Cosmetics (Alcohol) by AF8 Volumetric KF KF1574Insulin Standard by AF8 Volumetric KF KF1405Kerosene by AF8 Volumetric KF KF1059Textiles ndash Wool by AF8 Volumetric KF KF1246Toothpaste by AF8 Volumetric KF KF1095Antifreeze by AF7 Coulometric KF Moisture Titrator KF1466Oil-Mineral by AF7 Coulometric KF Moisture Titrator KF1224Diesel by AF7LC KF1259
Potentiometric Analyses Log
Free Fatty Acid in Animal FatRefined Vegetable 638ACalcium Carbonate in Acid Relief Tablets 646ASodium in Bacon 505Sodium Chloride in Barbecue Sauce 296BSodium in Beer 123Anionic surfactant in bath soap 453Chloride in Biscuit and Gravy mix 412CChlorine in Bleach 468DSodium in Butter 630BChloride in Cat Food 541CSurfactant in Detergent 438Fluoride in Ground Water 586Hydrogen Peroxide in Hair Permanents 28Vitamin C in Infant Formula 327AZinc in Motor Oils 133Anionic Surfactant in Shampoo 658ANitrate in Soil 284A
The Thermo Orion Applications Lab makes the difference when purchasing titration equipment Thermo Orion has hundreds ofapplication notes providing valuable methods and performance information for all of our titration equipment In addition to theexisting database of application notes the Application Lab will analyze customer samples for either method development or testvalidation procedures The Applications Lab is utilized in conjunction with the sale of a Thermo Orion titration unit Application development may be performed on any of Thermo Orionrsquos potentiometric or Karl Fischer Titrators
Listed below are just some of Thermo Orions titration application notesExamples of Applications
Register at wwwthermoorioncom to view the entire index of Thermo Orion Titration application notes
Applications
FoodConfectionaries
CosmeticsPharmaceuticals
WaterWaste Water
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | Turbo2 | AF8 | AF7AF7LC | 6
Customer Service and Support 8002251480 - 9782326015 (fax)
Titrator PLUSreg
bull Highly Versatile - analytical instrument with complete automation capability
bull 12 Preprogrammed Techniques - automate titrations pH and direct ion measurement
bull Potentiometric Titrations - including acidbase redox precipitation and complexometric
bull Simple - ldquoYESrdquo and ldquoNOrdquo operating commands
bull Method Memory - store up to 20 methods
bull Data Collection Software - collect view store and print data
bull AssuredAccuracytrade - titrant delivery with gravimetric calibration
bull Karl Fischer Accessory - for low throughput moisture analysis
Ideally suited for dedicated routine measurements the Model 960 is intended foruse in laboratories where automation is needed to overcome problems of samplethroughput or analytical complexity What differentiates the Model 960 from othersingle parameter analyzers or automatic titrators is its versatility Not only can it beused for performing classical titrations it can also automate the measurement ofany species measurable by ion selective and pH electrodes All of the operatingprocedures appear on the instrumentrsquos display in the form of easy-to-understandquestions Using the Model 960 improves precision and response time for electrodemeasurements Because the analysis is automated each step is carried outconsistently mdash time after time operator to operator Quick release fittings on thebottles make it easy to disconnect one bottle and connect another Therersquos no needto stock spare burettes for fast reagent changes The dispenser is a rotaryreciprocating pump Unlike an automatic burette the pump has no valves to switchfor refilling Also there is no dead volume making changing reagents easy and fastTypical problems encountered when doing manual analyses are virtually eliminatedmaking ISE technology better suited for a busy day of testing Higher levels of
automation can be achieved by adding a Model 960ADWorkstation as an auxiliary reagent dispenser The Model960AD is available in two versions for use with or without theAS3000 Series Autosampler You can integrate up to eight workstations and an autosampler into one system formaximum versatility For routine measurements a short form printout is available All pertinent GLP information isprovided including sample ID electrode time date and theresult The Model 960 can calculate results in 22 units ofmeasurement In addition diagnostic error messages may be printed to provide troubleshooting information such asexcessive electrode drift or matrix effect For methoddevelopment a long form printout is available where raw data is printed including volume of reagent millivolts timeelapsed a plot of the curves where appropriate and method parameters
Cat No
096000
096002
Description of Instruments
960 Titrator PLUS System complete with EA 940 pHISE Meter Model 960 Titrator Plus Module Includes Base assembly tower assembly electrodeholder stirrer two dispenser probes anti-diffusion dispenser probe with six tips tubing kit calibration kit cable (Models 960 and EA 940) referencetablet two working solution bottles two dip tubes and caps line cords and instruction manual User selectable power requirement 100115220240V plusmn10
960 Titrator PLUS Module (Module does not include EA 940) Includes Base assembly tower assembly electrode holder stirrer two dispenser probesone anti-diffusion dispenser probe with six tips tubing kit calibration kit cable (Models 960 EA 940) reference tablet three speed number note padstwo working solution bottles two dip tubes and caps PROM upgrade kit (to update software in EA 940) line cord US standard connector andinstruction manual User selectable power requirement 100115220240 plusmn10
Model 960
Techniques Specifications Accessories amp Consumables Electrodes amp Solutions
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 7
Customer Service and Support 8002251480 - 9782326015 (fax)
bull AS3000 Series Autosamplers - for use with the Model 960 TitratorPLUSreg
bull Enhance Lab Productivity - automate Sample Preparation Calibrations and Standardizations
bull Increased Flexibility - interchangeable beaker racks and probe holders
bull Three Rack Sizes - (45) 50 mL (28) 150 mL or (18) 250 mL beakers
bull Quality Control - up to five rinse beakers to clean the electrodes between analyses
The new AS3000 XYZ Autosamplers are designed for use with the Model 960 TitratorPLUS Thermo Orion offers a choice in autosamplers withmultiple rack configurations to provide flexibility for high sample throughput Runtitrations or other pHISE techniques with the use of the new AS3000 seriesAutosampler overnight Additionally the probe arm assembly moves along the
X Y and Z-axes at speeds from 0 to 35 inches per second withfull control of velocity and acceleration allowing for fastersampling and analyses New Autosampler packages andupgrades from your existing Thermo Orion sample changer are available
Description of Accessories
Model AS3000 Autosampler complete with 45-position rack electrode holder interface cable line cord pkg of (50) 50 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 28-position rack electrode holder interface cable line cord pkg of (50) 150 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 18-position rack electrode holder interface cable line cord pkg of (25) 250 ml plastic beakers and instruction manual 115V220V
Model 960 with AutoSampler 45-Position Rack Designed for 50 mL Beakers (Beakers Included)
Model 960 with AutoSampler 28-Position Rack Designed for 150 mL Beakers (Beakers Included)
Model 960 with AutoSampler 18-Position Rack Designed for 250 mL Beakers (Beakers Included)
45-Position Rack Designed for 50 mL Beakers
28-Position Rack Designed for 150 mL Beakers
18-Position Rack Designed for 250 mL Beakers
Beakers Plastic 50 mL pkg of 50
Beakers Plastic 150 mL pkg of 50 (Replaces Cat No 096S17)
Beakers Plastic 250 mL pkg of 25
Beakers Plastic 45 mL pkg of 50
Cat No
AS3050
AS3150
AS3250
96050A
96150A
96250A
ASR050
ASR150
ASR250
ASB050
ASB150
ASB250
096S22
New Series Autosamplers
AS3000
Feature
50 mL beaker sold with autosampler
150 mL beaker sold with autosampler
250 mL beaker sold with autosampler
Accuracy
Agency Approvals
Environmental Requirements
Paint Color
Description
Polypropylene Chemically resistant 42 mm diameter
Polypropylene Chemically resistant 57 mm diameter
Polypropylene Chemically resistant 68 mm diameter
plusmn 10 mm in all axes
CE UL CSA
5 to 45 degC and 20 to 80 Relative Humidity
Carbide Black
Feature
Programmable Sample Access Area
Foot Print
Height to top of Z-axis
Sample Capacity
Model AS3050
Model AS3150
Model AS3250
Computer Interface
Power Voltage
Description
187 X 70 X 475 inches (W X D X H)
2325X145X1575 inches (W X D X H)
59X37X40 cm
45 50 mL glass or plastic beaker
28 150 mL glass or plastic beaker
18 250 mL glass or plastic beaker
RS232
90-240 Vac 5060 Hz
Accessories amp Consumables
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 8
Customer Service and Support 8002251480 - 9782326015 (fax)
bull Economical Automatic Titrator - fits any budget
bull Automates - routine titrations can be done easily
bull Modular Design ndash the compact design allows flexibility and versatility
bull Superior Features - incorporates premium ROSStrade pH electrode technology
bull Printer Options - provide comprehensive record of results and methods
Cat No
095000
095001
095002
095003
095004
Description of Instruments
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSStrade Sure-Flowreg pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
950 FAST QC Titrator without line cord Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional and manual
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
Note To use with an external printer order 950DPU OR 950EPN splitter cables
The Model 950 incorporates the superior features of the patented ROSS pHtechnology into an economical yet versatile potentiometric titrator The Model 950performs AcidBase titrations including non-aqueous samples oxidation-reductionprecipitation and complexometric titrations using ion selective electrodes Automateall routine manual color end-point titrations with the Model 950 preset end-pointtechnique The Model 950 preset technique can titrate to one or two preset pH ormillivolt values to measure P amp M alkalinity of water or acidity of carbonatedbeverages The Model 950 first derivative technique offers titration to one or multipleinflection points for many analyses for example chloride in food ingredients copperin a plating bath or TAN and TBN of the petroleum products The Titrant and theentire system can be standardized automatically against an accurately weighedknown NIST or other national standards using the standardize system technique
This basic titrator is extremely simple to use just press a singlebutton to start the titration Automatic pH calibration menuleads you to perform one or two point calibration On-boardmemory stores up to 10 methods that can be recalled at thepush of a button Methods can be locked to safeguardaccidental deletion Unique to Thermo Orion titrators theAssuredAccuracytrade feature allows the gravimetric calibration of the entire dispensing system making it easy to meet ISO 9000 and GLP requirements Simply add a secondworkstation to expand your Model 950 titration capabilitiesand enhance your labrsquos productivity
Fast QCtrade Titrator
Model 950
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 9
Customer Service and Support 8002251480 - 9782326015 (fax)
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Note To use with an external printer order 950DPU OR 950EPN splitter cables
bull Ion Measurement - made easier through automation
bull Simple - self-calibrating one beaker analysis
bull Workstation Design - reduces chemical usage and reagent handling
bull KAPtrade Analysis ndash one Beaker Analysis
bull Customize - with any ionplusreg combination ion selective electrode
The Model 930 Ionalyzer System and ionplus electrodes provide fast reliable ionmeasurement with an easy-to-use precise analysis technique The exclusive KAPtrade
Analysis techniques ensure dependable performance even with the most difficultsamples Design features provide a saving in time and cost per analysis Automatedreagent handling reduces time spent preparing samples and produces less reagentwaste The Model 930 Ionalyzer workstation also holds electrodes and stirs thesample during analysis Using advanced ionplus electrodes (with Sure-Flowreg
references) measure even the dirtiest samples without additional filtration ordistillation steps Save time and money measuring such species as cyanide inplating solutions and sulfide in pulping liquors Customize to meet your specializedneeds calculate results in your choice of concentration units and report all results onthe integrated or external printer With dual channel inputs you can add anadditional workstation to expand your analysis capacity Store up to ten differentmethods for maximum productivity The Model 930 Ionalyzer also measures pHproviding additional measurement choice For example the Model 930 is ideal forboth ammonia and pH measurements in effluent KAP Analysis techniques improve
performance by adding small aliquots of a standard to thesample This self-calibrating technique performs bothelectrode calibration and sample measurement in one beakerKAP Analysis minimizes errors due to complexing agents orcomplicated sample backgrounds Choose between singleknown addition for simple measurements or double ormultiple known addition for samples with complexbackgrounds Quickly measure compounds such as chloridein food in one beaker without hazardous metal titration Verifyanalysis with spike recovery automatically performed in themultiple known addition technique Also automate other directmeasurements with the ACCUreadtrade or serial calibrationtechniques performing an entire multipoint calibration in onebeaker Providing calibration measurement and validation ofresults automatically the Model 930 Ionalyzer improvesspeed and accuracy and lowers cost per analysis
Cat No
093000
093001
093002
093003
093004
Description of Instruments
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 220V 60Hz
930 Ionalyzer without line cord Includes workstation control unit printer printer paper cables tubing instructional and manual
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 220V 60Hz
Ionalyzerreg System
Model 930
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 10
Customer Service and Support 8002251480 - 9782326015 (fax)
The chart below describes the various techniques available on Thermo Orionrsquos titrators and dispensing workstations and when they are recommended
Endpoint Analysis
First Derivative(For Model 960and Model 950)
Second Derivative(For Model 960)
Present Endpoint(For Model 960950)
KAPtrade Analysis
Multiple Known Addition(For Model 960and Model 930)
Multiple Known Subtraction(For Model 960)
Multiple Analate Addition(For Model 960)
Serial Calibration(For Model 960 930)
GAPtrade Analysis
Gran Function(For Model 960)
Gran Predict(For Model 960)
Assist Analysis
Standardize System(For Model 960)
HELP Analysis (For Model 960)
pH Read(For Model 960)
Description
Automated titration technique which calculates endpoints from the first derivative of the titration curve
Similar to first derivative but endpoints arecalculated from second derivative
Allows titration to proceed to one or two preset mV or pH values
Performs calibration and calculates sampleconcentration by adding aliquots of standard to sample
Performs calibration and calculates sampleconcentration by adding aliquots of reagentwhich reacts with sample species
Performs calibration and calculates sampleconcentration by adding aliquots of sample to astandard solution
Generates calibration curve by adding aliquotsof standard to a beaker of water and ISA
Similar to first derivative but Gran Functionsapplied to determine equivalence points
Similar to Gran Function but looks at data onone side of equivalence point only
Standardizes entire system (electrodeselectronics dispenser titrant)
Recommends the best method by adding aliquots of reagent to sample and analyzing data
For accurate pH measurements and direct ion read
When Recommended
bull Routine potentiometric titrations bull Determine poorly defined and
multiple endpoints
bull When required by industry standardsbull Eliminates false endpoint detection
bull P amp M alkalinity of water and wastewaterbull Titrations with no clearly defined endpointbull When required by industry standards
bull Measure nontitratable species ie NA+ K+ NO3
- NH3bull Complex sample matrixbull More precision required than
Standard calibration
bull No stable standard solution for ion of interest ie sulfide
bull Use for direct read of ions (calibrate and read series of samples)
bull Concentrated samplebull Viscous samples
bull Low level measurementsbull Checking electrode performance
bull Titrations with poor endpointbull Titrations with two endpointsbull Titrations with asymmetric curves
bull Slow reactionsbull Speed requiredbull Low level titrations ie Cl-
bull Highest system accuracy required
bull When unsure of what technique or measurement parameters to use
bull Automation of pH or direct ion read Can beused on autosampler
Advantage
bull Precisionbull No ambiguity in location of
endpoints
bull Precision
bull No interference from color or turbidity
bull No need for independent calibration or recalibration
bull Matrix effects minimizedbull Recovery test performed with
every sample
bull Faster than conventional titrationbull Uses less reagent than
conventional titration
bull Sample automatically diluted as part of analysis
bull Sample can be added from automatic pipet
bull Defines non-linear portion of calibration curve
bull Eliminates need to prepare standards
bull Accuracy
bull Speedbull Less reagent consumption
bull One-step standardization of all system components
bull Optimizes method
bull Automation accuracy
TechniquesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 11
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
Output
mV
Concentration
pH Range
Temperature
Power RequirementVoltageFrequency
Titration Modes
Methods Saved
Display
Variable Speed Stirring Paddle
Input
DimensionsHeightWidthDepth
CaseSplash and Chemical Resistant
Environmental Requirements5 to 45 degC and 5 to 85relative humidity
Autosampler Option
Agency Approvals
Ordering Information110 V220 VWithout Line CordWithout Printer 110 VWithout Printer 220 V960 Module
Model 960
EA 940 RS232 recorder Karl Fischer 4RS232 ports for connection to EA 940 printercomputer and balance one 15-pin parallel port
-160000 to 160000 mV
00001 to 99999
-2000 to 19999
-50 to 1050 ˚C
110120220240 VAC5060 Hz
All 930 and 950 OptionsSecond Derivative TitrationSingle Known SubtractionDouble Known SubtractionMultiple Known SubtractionMultiple Analate AdditionGran FunctionGran PredictStandardize SystemHelp AnalysispH Read
Up to Twenty
Custom color vacuumfluorescent with 40 characterprompt line
radic
Two BNC two pin tip dual bananajacks for PT-100 style ATC probe
With Tower16rdquo17rdquo18rdquo
radic
radic
Yes
CE
096000 (110V220V)
096002
Model 950
RS232 recorder Karl Fischer
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 ˚C
9 VDC line converter for110120220240 VAC5060 Hz
Preset pH EndpointPreset mV EndpointFirst Derivative Titration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip ground ATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
095000095001095002095003095004
Model 930
RS232 recorder
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 degC
9 VDC line converter for110120220240 VAC5060 Hz
Single Known AdditionDouble Known AdditionMultiple Known AdditionSerial Calibration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip groundATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
093000093001093002093003093004
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 12
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
0960KF
0607CA
0607CI
096010
096011
096014
096016
096017
096019
096021
096025
096035
096038
096039
096045
910003
0900A0
0900A1
0900A2
0GLP30
0GLP31PRT300
PRT301
55PR40
55PR49
Description of Accessories
Model 960KF Volumetric Karl Fischer Accessory Provides the hardware for performing Karl Fisher Moisture Analysis on the Model 960 Titrator Plus System Includes KF vessel with drain valve vessel top KF electrode (977900) and KF adapter stirrer with long shaft (096019) glass desiccant side arm stopper stand septum Teflon vessel O-ring plugs and O-rings
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 110 V (Use with cable 096050 for Model 960)
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 220 V (Use with cable 096050 for Model 960)
Auxilary Dispenser with tower complete with dispenser probes tubing kit interface cable dispenser base electrode holder stirrer power cord and instruction manual 115230 V
Auxilary Dispenser without tower for use with AS3000 Series Autosampler Includes dispenser probes tubing kit interface cable power cord and instruction manual 115230 V
Description of Consumables
960 Tubing Kit Includes tube and connector for working solution bottle to AUTOdispenser tube and connectors for AUTOdispenser to dispenser probe
Dispenser Probe pkg of 2 and roll of cleaning wire pkg of 1
Anti-Diffusion Dispenser Probe One dispenser probe with six replaceable tips For low-level analyses or dense titrants
Stirrer to fit electrode tower includes stirrer paddle
Stirrer Paddle to fit 096019 pkg of 3
Dip Tube with sealable cap to fit working solution bottle pkg of 6
Gas Absorption Cartridge fits top of working solution bottle Absorbs carbon dioxide and moisture Absorbent not included
AUTOdispenser Calibration Kit includes five sealable plastic vials 8 ml capacity
Bottles 475 ml amber glass for working solution pkg of 12 Req Cat No 096025
Bottles 475 ml translucent plastic for working solution pkg of 12 Req Cat No 096025
Electrode Storage Bottle pkg of 3
Description of Printers
Model 900A Thermal Printer for Models 950930 110V
Model 900A Thermal Printer for Models 950930 220V
Model 900A Thermal Printer for Models 950930 No Adapter 220V
Ink Based GLP Printer for Model 960 includes instruction manual 110 V
Ink Based GLP Printer for Model 960 includes step-down transformer instruction manual 220 V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 110V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 220V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 115 V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 220 V
Continue to next page
Accessories and ConsumablesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 13
Customer Service and Support 8002251480 - 9782326015 (fax)
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Introduction
Thermo Orion offers a wide variety of innovative titration and automation productsThermo Orionrsquos expertise in titration began with the automation of Ion Selective Electrode(ISE) analyses Over time it expanded to include an entire product line dedicated topotentiometric analyses as well as a full line of Karl Fischer Moisture Analysis TitratorsThrough continued research and development Thermo Orion is always expanding intonew technologies to ldquoSense the Futurerdquo
Potentiometric workstations and titration systems make analyses quick easy andreproducibly accurate Whether the analysis is surfactants in shampoo fluoride indrinking water or Vitamin C in juices Thermo Orion has the system to automate your measurements
Thermo Orion has an automated Karl Fischer Titrator to accurately measure moisture in most any type of sample Numerous applications have been developed for a variety of industries including the agricultural chemical pharmaceutical cosmetic and food industries
A wide range of pH ISE and Specialty titration electrodes are available including thesurfactant electrode to test for anionic cationic and nonionic surfactants
The New AS3000 Series Autosampler is compatible with the Model 960 TitratorPLUSregsbquo as well as Models 162A 535A 550A 555A and 862A benchtop meters Increase lab productivity by automating sample preparation and analyses with an AS3000 Autosampler
Model 960
TURBO2reg
pH and ISE Electrodes
AS3000 Series Autosampler
Customer Service and Support 8002251480 - 9782326015 (fax)
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | Turbo2 | AF8 | AF7AF7LC | 5
Karl Fischer Moisture Analyses Log
Advil Tablets by TURBO2 Blending Volumetric KF KF1523Chewing Gum by TURBO2 Blending Volumetric KF KF1286Face Lotion by TURBO2 Blending Volumetric KF KF1193Freeze-Dried Foods by TURBO2 Blending Volumetric KF KF1409Ink-Printing by TURBO2 Blending Volumetric KF KF1013Pasta by TURBO2 Blending Volumetric KF KF1039Sugar by TURBO2 Blending Volumetric KF KF1565Brake Fluid by AF8 Volumetric KF KF1088Cosmetics (Alcohol) by AF8 Volumetric KF KF1574Insulin Standard by AF8 Volumetric KF KF1405Kerosene by AF8 Volumetric KF KF1059Textiles ndash Wool by AF8 Volumetric KF KF1246Toothpaste by AF8 Volumetric KF KF1095Antifreeze by AF7 Coulometric KF Moisture Titrator KF1466Oil-Mineral by AF7 Coulometric KF Moisture Titrator KF1224Diesel by AF7LC KF1259
Potentiometric Analyses Log
Free Fatty Acid in Animal FatRefined Vegetable 638ACalcium Carbonate in Acid Relief Tablets 646ASodium in Bacon 505Sodium Chloride in Barbecue Sauce 296BSodium in Beer 123Anionic surfactant in bath soap 453Chloride in Biscuit and Gravy mix 412CChlorine in Bleach 468DSodium in Butter 630BChloride in Cat Food 541CSurfactant in Detergent 438Fluoride in Ground Water 586Hydrogen Peroxide in Hair Permanents 28Vitamin C in Infant Formula 327AZinc in Motor Oils 133Anionic Surfactant in Shampoo 658ANitrate in Soil 284A
The Thermo Orion Applications Lab makes the difference when purchasing titration equipment Thermo Orion has hundreds ofapplication notes providing valuable methods and performance information for all of our titration equipment In addition to theexisting database of application notes the Application Lab will analyze customer samples for either method development or testvalidation procedures The Applications Lab is utilized in conjunction with the sale of a Thermo Orion titration unit Application development may be performed on any of Thermo Orionrsquos potentiometric or Karl Fischer Titrators
Listed below are just some of Thermo Orions titration application notesExamples of Applications
Register at wwwthermoorioncom to view the entire index of Thermo Orion Titration application notes
Applications
FoodConfectionaries
CosmeticsPharmaceuticals
WaterWaste Water
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | Turbo2 | AF8 | AF7AF7LC | 6
Customer Service and Support 8002251480 - 9782326015 (fax)
Titrator PLUSreg
bull Highly Versatile - analytical instrument with complete automation capability
bull 12 Preprogrammed Techniques - automate titrations pH and direct ion measurement
bull Potentiometric Titrations - including acidbase redox precipitation and complexometric
bull Simple - ldquoYESrdquo and ldquoNOrdquo operating commands
bull Method Memory - store up to 20 methods
bull Data Collection Software - collect view store and print data
bull AssuredAccuracytrade - titrant delivery with gravimetric calibration
bull Karl Fischer Accessory - for low throughput moisture analysis
Ideally suited for dedicated routine measurements the Model 960 is intended foruse in laboratories where automation is needed to overcome problems of samplethroughput or analytical complexity What differentiates the Model 960 from othersingle parameter analyzers or automatic titrators is its versatility Not only can it beused for performing classical titrations it can also automate the measurement ofany species measurable by ion selective and pH electrodes All of the operatingprocedures appear on the instrumentrsquos display in the form of easy-to-understandquestions Using the Model 960 improves precision and response time for electrodemeasurements Because the analysis is automated each step is carried outconsistently mdash time after time operator to operator Quick release fittings on thebottles make it easy to disconnect one bottle and connect another Therersquos no needto stock spare burettes for fast reagent changes The dispenser is a rotaryreciprocating pump Unlike an automatic burette the pump has no valves to switchfor refilling Also there is no dead volume making changing reagents easy and fastTypical problems encountered when doing manual analyses are virtually eliminatedmaking ISE technology better suited for a busy day of testing Higher levels of
automation can be achieved by adding a Model 960ADWorkstation as an auxiliary reagent dispenser The Model960AD is available in two versions for use with or without theAS3000 Series Autosampler You can integrate up to eight workstations and an autosampler into one system formaximum versatility For routine measurements a short form printout is available All pertinent GLP information isprovided including sample ID electrode time date and theresult The Model 960 can calculate results in 22 units ofmeasurement In addition diagnostic error messages may be printed to provide troubleshooting information such asexcessive electrode drift or matrix effect For methoddevelopment a long form printout is available where raw data is printed including volume of reagent millivolts timeelapsed a plot of the curves where appropriate and method parameters
Cat No
096000
096002
Description of Instruments
960 Titrator PLUS System complete with EA 940 pHISE Meter Model 960 Titrator Plus Module Includes Base assembly tower assembly electrodeholder stirrer two dispenser probes anti-diffusion dispenser probe with six tips tubing kit calibration kit cable (Models 960 and EA 940) referencetablet two working solution bottles two dip tubes and caps line cords and instruction manual User selectable power requirement 100115220240V plusmn10
960 Titrator PLUS Module (Module does not include EA 940) Includes Base assembly tower assembly electrode holder stirrer two dispenser probesone anti-diffusion dispenser probe with six tips tubing kit calibration kit cable (Models 960 EA 940) reference tablet three speed number note padstwo working solution bottles two dip tubes and caps PROM upgrade kit (to update software in EA 940) line cord US standard connector andinstruction manual User selectable power requirement 100115220240 plusmn10
Model 960
Techniques Specifications Accessories amp Consumables Electrodes amp Solutions
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 7
Customer Service and Support 8002251480 - 9782326015 (fax)
bull AS3000 Series Autosamplers - for use with the Model 960 TitratorPLUSreg
bull Enhance Lab Productivity - automate Sample Preparation Calibrations and Standardizations
bull Increased Flexibility - interchangeable beaker racks and probe holders
bull Three Rack Sizes - (45) 50 mL (28) 150 mL or (18) 250 mL beakers
bull Quality Control - up to five rinse beakers to clean the electrodes between analyses
The new AS3000 XYZ Autosamplers are designed for use with the Model 960 TitratorPLUS Thermo Orion offers a choice in autosamplers withmultiple rack configurations to provide flexibility for high sample throughput Runtitrations or other pHISE techniques with the use of the new AS3000 seriesAutosampler overnight Additionally the probe arm assembly moves along the
X Y and Z-axes at speeds from 0 to 35 inches per second withfull control of velocity and acceleration allowing for fastersampling and analyses New Autosampler packages andupgrades from your existing Thermo Orion sample changer are available
Description of Accessories
Model AS3000 Autosampler complete with 45-position rack electrode holder interface cable line cord pkg of (50) 50 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 28-position rack electrode holder interface cable line cord pkg of (50) 150 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 18-position rack electrode holder interface cable line cord pkg of (25) 250 ml plastic beakers and instruction manual 115V220V
Model 960 with AutoSampler 45-Position Rack Designed for 50 mL Beakers (Beakers Included)
Model 960 with AutoSampler 28-Position Rack Designed for 150 mL Beakers (Beakers Included)
Model 960 with AutoSampler 18-Position Rack Designed for 250 mL Beakers (Beakers Included)
45-Position Rack Designed for 50 mL Beakers
28-Position Rack Designed for 150 mL Beakers
18-Position Rack Designed for 250 mL Beakers
Beakers Plastic 50 mL pkg of 50
Beakers Plastic 150 mL pkg of 50 (Replaces Cat No 096S17)
Beakers Plastic 250 mL pkg of 25
Beakers Plastic 45 mL pkg of 50
Cat No
AS3050
AS3150
AS3250
96050A
96150A
96250A
ASR050
ASR150
ASR250
ASB050
ASB150
ASB250
096S22
New Series Autosamplers
AS3000
Feature
50 mL beaker sold with autosampler
150 mL beaker sold with autosampler
250 mL beaker sold with autosampler
Accuracy
Agency Approvals
Environmental Requirements
Paint Color
Description
Polypropylene Chemically resistant 42 mm diameter
Polypropylene Chemically resistant 57 mm diameter
Polypropylene Chemically resistant 68 mm diameter
plusmn 10 mm in all axes
CE UL CSA
5 to 45 degC and 20 to 80 Relative Humidity
Carbide Black
Feature
Programmable Sample Access Area
Foot Print
Height to top of Z-axis
Sample Capacity
Model AS3050
Model AS3150
Model AS3250
Computer Interface
Power Voltage
Description
187 X 70 X 475 inches (W X D X H)
2325X145X1575 inches (W X D X H)
59X37X40 cm
45 50 mL glass or plastic beaker
28 150 mL glass or plastic beaker
18 250 mL glass or plastic beaker
RS232
90-240 Vac 5060 Hz
Accessories amp Consumables
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 8
Customer Service and Support 8002251480 - 9782326015 (fax)
bull Economical Automatic Titrator - fits any budget
bull Automates - routine titrations can be done easily
bull Modular Design ndash the compact design allows flexibility and versatility
bull Superior Features - incorporates premium ROSStrade pH electrode technology
bull Printer Options - provide comprehensive record of results and methods
Cat No
095000
095001
095002
095003
095004
Description of Instruments
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSStrade Sure-Flowreg pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
950 FAST QC Titrator without line cord Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional and manual
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
Note To use with an external printer order 950DPU OR 950EPN splitter cables
The Model 950 incorporates the superior features of the patented ROSS pHtechnology into an economical yet versatile potentiometric titrator The Model 950performs AcidBase titrations including non-aqueous samples oxidation-reductionprecipitation and complexometric titrations using ion selective electrodes Automateall routine manual color end-point titrations with the Model 950 preset end-pointtechnique The Model 950 preset technique can titrate to one or two preset pH ormillivolt values to measure P amp M alkalinity of water or acidity of carbonatedbeverages The Model 950 first derivative technique offers titration to one or multipleinflection points for many analyses for example chloride in food ingredients copperin a plating bath or TAN and TBN of the petroleum products The Titrant and theentire system can be standardized automatically against an accurately weighedknown NIST or other national standards using the standardize system technique
This basic titrator is extremely simple to use just press a singlebutton to start the titration Automatic pH calibration menuleads you to perform one or two point calibration On-boardmemory stores up to 10 methods that can be recalled at thepush of a button Methods can be locked to safeguardaccidental deletion Unique to Thermo Orion titrators theAssuredAccuracytrade feature allows the gravimetric calibration of the entire dispensing system making it easy to meet ISO 9000 and GLP requirements Simply add a secondworkstation to expand your Model 950 titration capabilitiesand enhance your labrsquos productivity
Fast QCtrade Titrator
Model 950
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 9
Customer Service and Support 8002251480 - 9782326015 (fax)
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Note To use with an external printer order 950DPU OR 950EPN splitter cables
bull Ion Measurement - made easier through automation
bull Simple - self-calibrating one beaker analysis
bull Workstation Design - reduces chemical usage and reagent handling
bull KAPtrade Analysis ndash one Beaker Analysis
bull Customize - with any ionplusreg combination ion selective electrode
The Model 930 Ionalyzer System and ionplus electrodes provide fast reliable ionmeasurement with an easy-to-use precise analysis technique The exclusive KAPtrade
Analysis techniques ensure dependable performance even with the most difficultsamples Design features provide a saving in time and cost per analysis Automatedreagent handling reduces time spent preparing samples and produces less reagentwaste The Model 930 Ionalyzer workstation also holds electrodes and stirs thesample during analysis Using advanced ionplus electrodes (with Sure-Flowreg
references) measure even the dirtiest samples without additional filtration ordistillation steps Save time and money measuring such species as cyanide inplating solutions and sulfide in pulping liquors Customize to meet your specializedneeds calculate results in your choice of concentration units and report all results onthe integrated or external printer With dual channel inputs you can add anadditional workstation to expand your analysis capacity Store up to ten differentmethods for maximum productivity The Model 930 Ionalyzer also measures pHproviding additional measurement choice For example the Model 930 is ideal forboth ammonia and pH measurements in effluent KAP Analysis techniques improve
performance by adding small aliquots of a standard to thesample This self-calibrating technique performs bothelectrode calibration and sample measurement in one beakerKAP Analysis minimizes errors due to complexing agents orcomplicated sample backgrounds Choose between singleknown addition for simple measurements or double ormultiple known addition for samples with complexbackgrounds Quickly measure compounds such as chloridein food in one beaker without hazardous metal titration Verifyanalysis with spike recovery automatically performed in themultiple known addition technique Also automate other directmeasurements with the ACCUreadtrade or serial calibrationtechniques performing an entire multipoint calibration in onebeaker Providing calibration measurement and validation ofresults automatically the Model 930 Ionalyzer improvesspeed and accuracy and lowers cost per analysis
Cat No
093000
093001
093002
093003
093004
Description of Instruments
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 220V 60Hz
930 Ionalyzer without line cord Includes workstation control unit printer printer paper cables tubing instructional and manual
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 220V 60Hz
Ionalyzerreg System
Model 930
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 10
Customer Service and Support 8002251480 - 9782326015 (fax)
The chart below describes the various techniques available on Thermo Orionrsquos titrators and dispensing workstations and when they are recommended
Endpoint Analysis
First Derivative(For Model 960and Model 950)
Second Derivative(For Model 960)
Present Endpoint(For Model 960950)
KAPtrade Analysis
Multiple Known Addition(For Model 960and Model 930)
Multiple Known Subtraction(For Model 960)
Multiple Analate Addition(For Model 960)
Serial Calibration(For Model 960 930)
GAPtrade Analysis
Gran Function(For Model 960)
Gran Predict(For Model 960)
Assist Analysis
Standardize System(For Model 960)
HELP Analysis (For Model 960)
pH Read(For Model 960)
Description
Automated titration technique which calculates endpoints from the first derivative of the titration curve
Similar to first derivative but endpoints arecalculated from second derivative
Allows titration to proceed to one or two preset mV or pH values
Performs calibration and calculates sampleconcentration by adding aliquots of standard to sample
Performs calibration and calculates sampleconcentration by adding aliquots of reagentwhich reacts with sample species
Performs calibration and calculates sampleconcentration by adding aliquots of sample to astandard solution
Generates calibration curve by adding aliquotsof standard to a beaker of water and ISA
Similar to first derivative but Gran Functionsapplied to determine equivalence points
Similar to Gran Function but looks at data onone side of equivalence point only
Standardizes entire system (electrodeselectronics dispenser titrant)
Recommends the best method by adding aliquots of reagent to sample and analyzing data
For accurate pH measurements and direct ion read
When Recommended
bull Routine potentiometric titrations bull Determine poorly defined and
multiple endpoints
bull When required by industry standardsbull Eliminates false endpoint detection
bull P amp M alkalinity of water and wastewaterbull Titrations with no clearly defined endpointbull When required by industry standards
bull Measure nontitratable species ie NA+ K+ NO3
- NH3bull Complex sample matrixbull More precision required than
Standard calibration
bull No stable standard solution for ion of interest ie sulfide
bull Use for direct read of ions (calibrate and read series of samples)
bull Concentrated samplebull Viscous samples
bull Low level measurementsbull Checking electrode performance
bull Titrations with poor endpointbull Titrations with two endpointsbull Titrations with asymmetric curves
bull Slow reactionsbull Speed requiredbull Low level titrations ie Cl-
bull Highest system accuracy required
bull When unsure of what technique or measurement parameters to use
bull Automation of pH or direct ion read Can beused on autosampler
Advantage
bull Precisionbull No ambiguity in location of
endpoints
bull Precision
bull No interference from color or turbidity
bull No need for independent calibration or recalibration
bull Matrix effects minimizedbull Recovery test performed with
every sample
bull Faster than conventional titrationbull Uses less reagent than
conventional titration
bull Sample automatically diluted as part of analysis
bull Sample can be added from automatic pipet
bull Defines non-linear portion of calibration curve
bull Eliminates need to prepare standards
bull Accuracy
bull Speedbull Less reagent consumption
bull One-step standardization of all system components
bull Optimizes method
bull Automation accuracy
TechniquesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 11
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
Output
mV
Concentration
pH Range
Temperature
Power RequirementVoltageFrequency
Titration Modes
Methods Saved
Display
Variable Speed Stirring Paddle
Input
DimensionsHeightWidthDepth
CaseSplash and Chemical Resistant
Environmental Requirements5 to 45 degC and 5 to 85relative humidity
Autosampler Option
Agency Approvals
Ordering Information110 V220 VWithout Line CordWithout Printer 110 VWithout Printer 220 V960 Module
Model 960
EA 940 RS232 recorder Karl Fischer 4RS232 ports for connection to EA 940 printercomputer and balance one 15-pin parallel port
-160000 to 160000 mV
00001 to 99999
-2000 to 19999
-50 to 1050 ˚C
110120220240 VAC5060 Hz
All 930 and 950 OptionsSecond Derivative TitrationSingle Known SubtractionDouble Known SubtractionMultiple Known SubtractionMultiple Analate AdditionGran FunctionGran PredictStandardize SystemHelp AnalysispH Read
Up to Twenty
Custom color vacuumfluorescent with 40 characterprompt line
radic
Two BNC two pin tip dual bananajacks for PT-100 style ATC probe
With Tower16rdquo17rdquo18rdquo
radic
radic
Yes
CE
096000 (110V220V)
096002
Model 950
RS232 recorder Karl Fischer
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 ˚C
9 VDC line converter for110120220240 VAC5060 Hz
Preset pH EndpointPreset mV EndpointFirst Derivative Titration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip ground ATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
095000095001095002095003095004
Model 930
RS232 recorder
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 degC
9 VDC line converter for110120220240 VAC5060 Hz
Single Known AdditionDouble Known AdditionMultiple Known AdditionSerial Calibration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip groundATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
093000093001093002093003093004
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 12
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
0960KF
0607CA
0607CI
096010
096011
096014
096016
096017
096019
096021
096025
096035
096038
096039
096045
910003
0900A0
0900A1
0900A2
0GLP30
0GLP31PRT300
PRT301
55PR40
55PR49
Description of Accessories
Model 960KF Volumetric Karl Fischer Accessory Provides the hardware for performing Karl Fisher Moisture Analysis on the Model 960 Titrator Plus System Includes KF vessel with drain valve vessel top KF electrode (977900) and KF adapter stirrer with long shaft (096019) glass desiccant side arm stopper stand septum Teflon vessel O-ring plugs and O-rings
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 110 V (Use with cable 096050 for Model 960)
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 220 V (Use with cable 096050 for Model 960)
Auxilary Dispenser with tower complete with dispenser probes tubing kit interface cable dispenser base electrode holder stirrer power cord and instruction manual 115230 V
Auxilary Dispenser without tower for use with AS3000 Series Autosampler Includes dispenser probes tubing kit interface cable power cord and instruction manual 115230 V
Description of Consumables
960 Tubing Kit Includes tube and connector for working solution bottle to AUTOdispenser tube and connectors for AUTOdispenser to dispenser probe
Dispenser Probe pkg of 2 and roll of cleaning wire pkg of 1
Anti-Diffusion Dispenser Probe One dispenser probe with six replaceable tips For low-level analyses or dense titrants
Stirrer to fit electrode tower includes stirrer paddle
Stirrer Paddle to fit 096019 pkg of 3
Dip Tube with sealable cap to fit working solution bottle pkg of 6
Gas Absorption Cartridge fits top of working solution bottle Absorbs carbon dioxide and moisture Absorbent not included
AUTOdispenser Calibration Kit includes five sealable plastic vials 8 ml capacity
Bottles 475 ml amber glass for working solution pkg of 12 Req Cat No 096025
Bottles 475 ml translucent plastic for working solution pkg of 12 Req Cat No 096025
Electrode Storage Bottle pkg of 3
Description of Printers
Model 900A Thermal Printer for Models 950930 110V
Model 900A Thermal Printer for Models 950930 220V
Model 900A Thermal Printer for Models 950930 No Adapter 220V
Ink Based GLP Printer for Model 960 includes instruction manual 110 V
Ink Based GLP Printer for Model 960 includes step-down transformer instruction manual 220 V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 110V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 220V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 115 V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 220 V
Continue to next page
Accessories and ConsumablesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 13
Customer Service and Support 8002251480 - 9782326015 (fax)
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Karl Fischer Moisture Analyses Log
Advil Tablets by TURBO2 Blending Volumetric KF KF1523Chewing Gum by TURBO2 Blending Volumetric KF KF1286Face Lotion by TURBO2 Blending Volumetric KF KF1193Freeze-Dried Foods by TURBO2 Blending Volumetric KF KF1409Ink-Printing by TURBO2 Blending Volumetric KF KF1013Pasta by TURBO2 Blending Volumetric KF KF1039Sugar by TURBO2 Blending Volumetric KF KF1565Brake Fluid by AF8 Volumetric KF KF1088Cosmetics (Alcohol) by AF8 Volumetric KF KF1574Insulin Standard by AF8 Volumetric KF KF1405Kerosene by AF8 Volumetric KF KF1059Textiles ndash Wool by AF8 Volumetric KF KF1246Toothpaste by AF8 Volumetric KF KF1095Antifreeze by AF7 Coulometric KF Moisture Titrator KF1466Oil-Mineral by AF7 Coulometric KF Moisture Titrator KF1224Diesel by AF7LC KF1259
Potentiometric Analyses Log
Free Fatty Acid in Animal FatRefined Vegetable 638ACalcium Carbonate in Acid Relief Tablets 646ASodium in Bacon 505Sodium Chloride in Barbecue Sauce 296BSodium in Beer 123Anionic surfactant in bath soap 453Chloride in Biscuit and Gravy mix 412CChlorine in Bleach 468DSodium in Butter 630BChloride in Cat Food 541CSurfactant in Detergent 438Fluoride in Ground Water 586Hydrogen Peroxide in Hair Permanents 28Vitamin C in Infant Formula 327AZinc in Motor Oils 133Anionic Surfactant in Shampoo 658ANitrate in Soil 284A
The Thermo Orion Applications Lab makes the difference when purchasing titration equipment Thermo Orion has hundreds ofapplication notes providing valuable methods and performance information for all of our titration equipment In addition to theexisting database of application notes the Application Lab will analyze customer samples for either method development or testvalidation procedures The Applications Lab is utilized in conjunction with the sale of a Thermo Orion titration unit Application development may be performed on any of Thermo Orionrsquos potentiometric or Karl Fischer Titrators
Listed below are just some of Thermo Orions titration application notesExamples of Applications
Register at wwwthermoorioncom to view the entire index of Thermo Orion Titration application notes
Applications
FoodConfectionaries
CosmeticsPharmaceuticals
WaterWaste Water
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | Turbo2 | AF8 | AF7AF7LC | 6
Customer Service and Support 8002251480 - 9782326015 (fax)
Titrator PLUSreg
bull Highly Versatile - analytical instrument with complete automation capability
bull 12 Preprogrammed Techniques - automate titrations pH and direct ion measurement
bull Potentiometric Titrations - including acidbase redox precipitation and complexometric
bull Simple - ldquoYESrdquo and ldquoNOrdquo operating commands
bull Method Memory - store up to 20 methods
bull Data Collection Software - collect view store and print data
bull AssuredAccuracytrade - titrant delivery with gravimetric calibration
bull Karl Fischer Accessory - for low throughput moisture analysis
Ideally suited for dedicated routine measurements the Model 960 is intended foruse in laboratories where automation is needed to overcome problems of samplethroughput or analytical complexity What differentiates the Model 960 from othersingle parameter analyzers or automatic titrators is its versatility Not only can it beused for performing classical titrations it can also automate the measurement ofany species measurable by ion selective and pH electrodes All of the operatingprocedures appear on the instrumentrsquos display in the form of easy-to-understandquestions Using the Model 960 improves precision and response time for electrodemeasurements Because the analysis is automated each step is carried outconsistently mdash time after time operator to operator Quick release fittings on thebottles make it easy to disconnect one bottle and connect another Therersquos no needto stock spare burettes for fast reagent changes The dispenser is a rotaryreciprocating pump Unlike an automatic burette the pump has no valves to switchfor refilling Also there is no dead volume making changing reagents easy and fastTypical problems encountered when doing manual analyses are virtually eliminatedmaking ISE technology better suited for a busy day of testing Higher levels of
automation can be achieved by adding a Model 960ADWorkstation as an auxiliary reagent dispenser The Model960AD is available in two versions for use with or without theAS3000 Series Autosampler You can integrate up to eight workstations and an autosampler into one system formaximum versatility For routine measurements a short form printout is available All pertinent GLP information isprovided including sample ID electrode time date and theresult The Model 960 can calculate results in 22 units ofmeasurement In addition diagnostic error messages may be printed to provide troubleshooting information such asexcessive electrode drift or matrix effect For methoddevelopment a long form printout is available where raw data is printed including volume of reagent millivolts timeelapsed a plot of the curves where appropriate and method parameters
Cat No
096000
096002
Description of Instruments
960 Titrator PLUS System complete with EA 940 pHISE Meter Model 960 Titrator Plus Module Includes Base assembly tower assembly electrodeholder stirrer two dispenser probes anti-diffusion dispenser probe with six tips tubing kit calibration kit cable (Models 960 and EA 940) referencetablet two working solution bottles two dip tubes and caps line cords and instruction manual User selectable power requirement 100115220240V plusmn10
960 Titrator PLUS Module (Module does not include EA 940) Includes Base assembly tower assembly electrode holder stirrer two dispenser probesone anti-diffusion dispenser probe with six tips tubing kit calibration kit cable (Models 960 EA 940) reference tablet three speed number note padstwo working solution bottles two dip tubes and caps PROM upgrade kit (to update software in EA 940) line cord US standard connector andinstruction manual User selectable power requirement 100115220240 plusmn10
Model 960
Techniques Specifications Accessories amp Consumables Electrodes amp Solutions
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 7
Customer Service and Support 8002251480 - 9782326015 (fax)
bull AS3000 Series Autosamplers - for use with the Model 960 TitratorPLUSreg
bull Enhance Lab Productivity - automate Sample Preparation Calibrations and Standardizations
bull Increased Flexibility - interchangeable beaker racks and probe holders
bull Three Rack Sizes - (45) 50 mL (28) 150 mL or (18) 250 mL beakers
bull Quality Control - up to five rinse beakers to clean the electrodes between analyses
The new AS3000 XYZ Autosamplers are designed for use with the Model 960 TitratorPLUS Thermo Orion offers a choice in autosamplers withmultiple rack configurations to provide flexibility for high sample throughput Runtitrations or other pHISE techniques with the use of the new AS3000 seriesAutosampler overnight Additionally the probe arm assembly moves along the
X Y and Z-axes at speeds from 0 to 35 inches per second withfull control of velocity and acceleration allowing for fastersampling and analyses New Autosampler packages andupgrades from your existing Thermo Orion sample changer are available
Description of Accessories
Model AS3000 Autosampler complete with 45-position rack electrode holder interface cable line cord pkg of (50) 50 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 28-position rack electrode holder interface cable line cord pkg of (50) 150 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 18-position rack electrode holder interface cable line cord pkg of (25) 250 ml plastic beakers and instruction manual 115V220V
Model 960 with AutoSampler 45-Position Rack Designed for 50 mL Beakers (Beakers Included)
Model 960 with AutoSampler 28-Position Rack Designed for 150 mL Beakers (Beakers Included)
Model 960 with AutoSampler 18-Position Rack Designed for 250 mL Beakers (Beakers Included)
45-Position Rack Designed for 50 mL Beakers
28-Position Rack Designed for 150 mL Beakers
18-Position Rack Designed for 250 mL Beakers
Beakers Plastic 50 mL pkg of 50
Beakers Plastic 150 mL pkg of 50 (Replaces Cat No 096S17)
Beakers Plastic 250 mL pkg of 25
Beakers Plastic 45 mL pkg of 50
Cat No
AS3050
AS3150
AS3250
96050A
96150A
96250A
ASR050
ASR150
ASR250
ASB050
ASB150
ASB250
096S22
New Series Autosamplers
AS3000
Feature
50 mL beaker sold with autosampler
150 mL beaker sold with autosampler
250 mL beaker sold with autosampler
Accuracy
Agency Approvals
Environmental Requirements
Paint Color
Description
Polypropylene Chemically resistant 42 mm diameter
Polypropylene Chemically resistant 57 mm diameter
Polypropylene Chemically resistant 68 mm diameter
plusmn 10 mm in all axes
CE UL CSA
5 to 45 degC and 20 to 80 Relative Humidity
Carbide Black
Feature
Programmable Sample Access Area
Foot Print
Height to top of Z-axis
Sample Capacity
Model AS3050
Model AS3150
Model AS3250
Computer Interface
Power Voltage
Description
187 X 70 X 475 inches (W X D X H)
2325X145X1575 inches (W X D X H)
59X37X40 cm
45 50 mL glass or plastic beaker
28 150 mL glass or plastic beaker
18 250 mL glass or plastic beaker
RS232
90-240 Vac 5060 Hz
Accessories amp Consumables
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 8
Customer Service and Support 8002251480 - 9782326015 (fax)
bull Economical Automatic Titrator - fits any budget
bull Automates - routine titrations can be done easily
bull Modular Design ndash the compact design allows flexibility and versatility
bull Superior Features - incorporates premium ROSStrade pH electrode technology
bull Printer Options - provide comprehensive record of results and methods
Cat No
095000
095001
095002
095003
095004
Description of Instruments
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSStrade Sure-Flowreg pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
950 FAST QC Titrator without line cord Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional and manual
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
Note To use with an external printer order 950DPU OR 950EPN splitter cables
The Model 950 incorporates the superior features of the patented ROSS pHtechnology into an economical yet versatile potentiometric titrator The Model 950performs AcidBase titrations including non-aqueous samples oxidation-reductionprecipitation and complexometric titrations using ion selective electrodes Automateall routine manual color end-point titrations with the Model 950 preset end-pointtechnique The Model 950 preset technique can titrate to one or two preset pH ormillivolt values to measure P amp M alkalinity of water or acidity of carbonatedbeverages The Model 950 first derivative technique offers titration to one or multipleinflection points for many analyses for example chloride in food ingredients copperin a plating bath or TAN and TBN of the petroleum products The Titrant and theentire system can be standardized automatically against an accurately weighedknown NIST or other national standards using the standardize system technique
This basic titrator is extremely simple to use just press a singlebutton to start the titration Automatic pH calibration menuleads you to perform one or two point calibration On-boardmemory stores up to 10 methods that can be recalled at thepush of a button Methods can be locked to safeguardaccidental deletion Unique to Thermo Orion titrators theAssuredAccuracytrade feature allows the gravimetric calibration of the entire dispensing system making it easy to meet ISO 9000 and GLP requirements Simply add a secondworkstation to expand your Model 950 titration capabilitiesand enhance your labrsquos productivity
Fast QCtrade Titrator
Model 950
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 9
Customer Service and Support 8002251480 - 9782326015 (fax)
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Note To use with an external printer order 950DPU OR 950EPN splitter cables
bull Ion Measurement - made easier through automation
bull Simple - self-calibrating one beaker analysis
bull Workstation Design - reduces chemical usage and reagent handling
bull KAPtrade Analysis ndash one Beaker Analysis
bull Customize - with any ionplusreg combination ion selective electrode
The Model 930 Ionalyzer System and ionplus electrodes provide fast reliable ionmeasurement with an easy-to-use precise analysis technique The exclusive KAPtrade
Analysis techniques ensure dependable performance even with the most difficultsamples Design features provide a saving in time and cost per analysis Automatedreagent handling reduces time spent preparing samples and produces less reagentwaste The Model 930 Ionalyzer workstation also holds electrodes and stirs thesample during analysis Using advanced ionplus electrodes (with Sure-Flowreg
references) measure even the dirtiest samples without additional filtration ordistillation steps Save time and money measuring such species as cyanide inplating solutions and sulfide in pulping liquors Customize to meet your specializedneeds calculate results in your choice of concentration units and report all results onthe integrated or external printer With dual channel inputs you can add anadditional workstation to expand your analysis capacity Store up to ten differentmethods for maximum productivity The Model 930 Ionalyzer also measures pHproviding additional measurement choice For example the Model 930 is ideal forboth ammonia and pH measurements in effluent KAP Analysis techniques improve
performance by adding small aliquots of a standard to thesample This self-calibrating technique performs bothelectrode calibration and sample measurement in one beakerKAP Analysis minimizes errors due to complexing agents orcomplicated sample backgrounds Choose between singleknown addition for simple measurements or double ormultiple known addition for samples with complexbackgrounds Quickly measure compounds such as chloridein food in one beaker without hazardous metal titration Verifyanalysis with spike recovery automatically performed in themultiple known addition technique Also automate other directmeasurements with the ACCUreadtrade or serial calibrationtechniques performing an entire multipoint calibration in onebeaker Providing calibration measurement and validation ofresults automatically the Model 930 Ionalyzer improvesspeed and accuracy and lowers cost per analysis
Cat No
093000
093001
093002
093003
093004
Description of Instruments
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 220V 60Hz
930 Ionalyzer without line cord Includes workstation control unit printer printer paper cables tubing instructional and manual
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 220V 60Hz
Ionalyzerreg System
Model 930
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 10
Customer Service and Support 8002251480 - 9782326015 (fax)
The chart below describes the various techniques available on Thermo Orionrsquos titrators and dispensing workstations and when they are recommended
Endpoint Analysis
First Derivative(For Model 960and Model 950)
Second Derivative(For Model 960)
Present Endpoint(For Model 960950)
KAPtrade Analysis
Multiple Known Addition(For Model 960and Model 930)
Multiple Known Subtraction(For Model 960)
Multiple Analate Addition(For Model 960)
Serial Calibration(For Model 960 930)
GAPtrade Analysis
Gran Function(For Model 960)
Gran Predict(For Model 960)
Assist Analysis
Standardize System(For Model 960)
HELP Analysis (For Model 960)
pH Read(For Model 960)
Description
Automated titration technique which calculates endpoints from the first derivative of the titration curve
Similar to first derivative but endpoints arecalculated from second derivative
Allows titration to proceed to one or two preset mV or pH values
Performs calibration and calculates sampleconcentration by adding aliquots of standard to sample
Performs calibration and calculates sampleconcentration by adding aliquots of reagentwhich reacts with sample species
Performs calibration and calculates sampleconcentration by adding aliquots of sample to astandard solution
Generates calibration curve by adding aliquotsof standard to a beaker of water and ISA
Similar to first derivative but Gran Functionsapplied to determine equivalence points
Similar to Gran Function but looks at data onone side of equivalence point only
Standardizes entire system (electrodeselectronics dispenser titrant)
Recommends the best method by adding aliquots of reagent to sample and analyzing data
For accurate pH measurements and direct ion read
When Recommended
bull Routine potentiometric titrations bull Determine poorly defined and
multiple endpoints
bull When required by industry standardsbull Eliminates false endpoint detection
bull P amp M alkalinity of water and wastewaterbull Titrations with no clearly defined endpointbull When required by industry standards
bull Measure nontitratable species ie NA+ K+ NO3
- NH3bull Complex sample matrixbull More precision required than
Standard calibration
bull No stable standard solution for ion of interest ie sulfide
bull Use for direct read of ions (calibrate and read series of samples)
bull Concentrated samplebull Viscous samples
bull Low level measurementsbull Checking electrode performance
bull Titrations with poor endpointbull Titrations with two endpointsbull Titrations with asymmetric curves
bull Slow reactionsbull Speed requiredbull Low level titrations ie Cl-
bull Highest system accuracy required
bull When unsure of what technique or measurement parameters to use
bull Automation of pH or direct ion read Can beused on autosampler
Advantage
bull Precisionbull No ambiguity in location of
endpoints
bull Precision
bull No interference from color or turbidity
bull No need for independent calibration or recalibration
bull Matrix effects minimizedbull Recovery test performed with
every sample
bull Faster than conventional titrationbull Uses less reagent than
conventional titration
bull Sample automatically diluted as part of analysis
bull Sample can be added from automatic pipet
bull Defines non-linear portion of calibration curve
bull Eliminates need to prepare standards
bull Accuracy
bull Speedbull Less reagent consumption
bull One-step standardization of all system components
bull Optimizes method
bull Automation accuracy
TechniquesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 11
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
Output
mV
Concentration
pH Range
Temperature
Power RequirementVoltageFrequency
Titration Modes
Methods Saved
Display
Variable Speed Stirring Paddle
Input
DimensionsHeightWidthDepth
CaseSplash and Chemical Resistant
Environmental Requirements5 to 45 degC and 5 to 85relative humidity
Autosampler Option
Agency Approvals
Ordering Information110 V220 VWithout Line CordWithout Printer 110 VWithout Printer 220 V960 Module
Model 960
EA 940 RS232 recorder Karl Fischer 4RS232 ports for connection to EA 940 printercomputer and balance one 15-pin parallel port
-160000 to 160000 mV
00001 to 99999
-2000 to 19999
-50 to 1050 ˚C
110120220240 VAC5060 Hz
All 930 and 950 OptionsSecond Derivative TitrationSingle Known SubtractionDouble Known SubtractionMultiple Known SubtractionMultiple Analate AdditionGran FunctionGran PredictStandardize SystemHelp AnalysispH Read
Up to Twenty
Custom color vacuumfluorescent with 40 characterprompt line
radic
Two BNC two pin tip dual bananajacks for PT-100 style ATC probe
With Tower16rdquo17rdquo18rdquo
radic
radic
Yes
CE
096000 (110V220V)
096002
Model 950
RS232 recorder Karl Fischer
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 ˚C
9 VDC line converter for110120220240 VAC5060 Hz
Preset pH EndpointPreset mV EndpointFirst Derivative Titration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip ground ATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
095000095001095002095003095004
Model 930
RS232 recorder
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 degC
9 VDC line converter for110120220240 VAC5060 Hz
Single Known AdditionDouble Known AdditionMultiple Known AdditionSerial Calibration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip groundATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
093000093001093002093003093004
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 12
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
0960KF
0607CA
0607CI
096010
096011
096014
096016
096017
096019
096021
096025
096035
096038
096039
096045
910003
0900A0
0900A1
0900A2
0GLP30
0GLP31PRT300
PRT301
55PR40
55PR49
Description of Accessories
Model 960KF Volumetric Karl Fischer Accessory Provides the hardware for performing Karl Fisher Moisture Analysis on the Model 960 Titrator Plus System Includes KF vessel with drain valve vessel top KF electrode (977900) and KF adapter stirrer with long shaft (096019) glass desiccant side arm stopper stand septum Teflon vessel O-ring plugs and O-rings
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 110 V (Use with cable 096050 for Model 960)
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 220 V (Use with cable 096050 for Model 960)
Auxilary Dispenser with tower complete with dispenser probes tubing kit interface cable dispenser base electrode holder stirrer power cord and instruction manual 115230 V
Auxilary Dispenser without tower for use with AS3000 Series Autosampler Includes dispenser probes tubing kit interface cable power cord and instruction manual 115230 V
Description of Consumables
960 Tubing Kit Includes tube and connector for working solution bottle to AUTOdispenser tube and connectors for AUTOdispenser to dispenser probe
Dispenser Probe pkg of 2 and roll of cleaning wire pkg of 1
Anti-Diffusion Dispenser Probe One dispenser probe with six replaceable tips For low-level analyses or dense titrants
Stirrer to fit electrode tower includes stirrer paddle
Stirrer Paddle to fit 096019 pkg of 3
Dip Tube with sealable cap to fit working solution bottle pkg of 6
Gas Absorption Cartridge fits top of working solution bottle Absorbs carbon dioxide and moisture Absorbent not included
AUTOdispenser Calibration Kit includes five sealable plastic vials 8 ml capacity
Bottles 475 ml amber glass for working solution pkg of 12 Req Cat No 096025
Bottles 475 ml translucent plastic for working solution pkg of 12 Req Cat No 096025
Electrode Storage Bottle pkg of 3
Description of Printers
Model 900A Thermal Printer for Models 950930 110V
Model 900A Thermal Printer for Models 950930 220V
Model 900A Thermal Printer for Models 950930 No Adapter 220V
Ink Based GLP Printer for Model 960 includes instruction manual 110 V
Ink Based GLP Printer for Model 960 includes step-down transformer instruction manual 220 V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 110V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 220V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 115 V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 220 V
Continue to next page
Accessories and ConsumablesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 13
Customer Service and Support 8002251480 - 9782326015 (fax)
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Titrator PLUSreg
bull Highly Versatile - analytical instrument with complete automation capability
bull 12 Preprogrammed Techniques - automate titrations pH and direct ion measurement
bull Potentiometric Titrations - including acidbase redox precipitation and complexometric
bull Simple - ldquoYESrdquo and ldquoNOrdquo operating commands
bull Method Memory - store up to 20 methods
bull Data Collection Software - collect view store and print data
bull AssuredAccuracytrade - titrant delivery with gravimetric calibration
bull Karl Fischer Accessory - for low throughput moisture analysis
Ideally suited for dedicated routine measurements the Model 960 is intended foruse in laboratories where automation is needed to overcome problems of samplethroughput or analytical complexity What differentiates the Model 960 from othersingle parameter analyzers or automatic titrators is its versatility Not only can it beused for performing classical titrations it can also automate the measurement ofany species measurable by ion selective and pH electrodes All of the operatingprocedures appear on the instrumentrsquos display in the form of easy-to-understandquestions Using the Model 960 improves precision and response time for electrodemeasurements Because the analysis is automated each step is carried outconsistently mdash time after time operator to operator Quick release fittings on thebottles make it easy to disconnect one bottle and connect another Therersquos no needto stock spare burettes for fast reagent changes The dispenser is a rotaryreciprocating pump Unlike an automatic burette the pump has no valves to switchfor refilling Also there is no dead volume making changing reagents easy and fastTypical problems encountered when doing manual analyses are virtually eliminatedmaking ISE technology better suited for a busy day of testing Higher levels of
automation can be achieved by adding a Model 960ADWorkstation as an auxiliary reagent dispenser The Model960AD is available in two versions for use with or without theAS3000 Series Autosampler You can integrate up to eight workstations and an autosampler into one system formaximum versatility For routine measurements a short form printout is available All pertinent GLP information isprovided including sample ID electrode time date and theresult The Model 960 can calculate results in 22 units ofmeasurement In addition diagnostic error messages may be printed to provide troubleshooting information such asexcessive electrode drift or matrix effect For methoddevelopment a long form printout is available where raw data is printed including volume of reagent millivolts timeelapsed a plot of the curves where appropriate and method parameters
Cat No
096000
096002
Description of Instruments
960 Titrator PLUS System complete with EA 940 pHISE Meter Model 960 Titrator Plus Module Includes Base assembly tower assembly electrodeholder stirrer two dispenser probes anti-diffusion dispenser probe with six tips tubing kit calibration kit cable (Models 960 and EA 940) referencetablet two working solution bottles two dip tubes and caps line cords and instruction manual User selectable power requirement 100115220240V plusmn10
960 Titrator PLUS Module (Module does not include EA 940) Includes Base assembly tower assembly electrode holder stirrer two dispenser probesone anti-diffusion dispenser probe with six tips tubing kit calibration kit cable (Models 960 EA 940) reference tablet three speed number note padstwo working solution bottles two dip tubes and caps PROM upgrade kit (to update software in EA 940) line cord US standard connector andinstruction manual User selectable power requirement 100115220240 plusmn10
Model 960
Techniques Specifications Accessories amp Consumables Electrodes amp Solutions
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 7
Customer Service and Support 8002251480 - 9782326015 (fax)
bull AS3000 Series Autosamplers - for use with the Model 960 TitratorPLUSreg
bull Enhance Lab Productivity - automate Sample Preparation Calibrations and Standardizations
bull Increased Flexibility - interchangeable beaker racks and probe holders
bull Three Rack Sizes - (45) 50 mL (28) 150 mL or (18) 250 mL beakers
bull Quality Control - up to five rinse beakers to clean the electrodes between analyses
The new AS3000 XYZ Autosamplers are designed for use with the Model 960 TitratorPLUS Thermo Orion offers a choice in autosamplers withmultiple rack configurations to provide flexibility for high sample throughput Runtitrations or other pHISE techniques with the use of the new AS3000 seriesAutosampler overnight Additionally the probe arm assembly moves along the
X Y and Z-axes at speeds from 0 to 35 inches per second withfull control of velocity and acceleration allowing for fastersampling and analyses New Autosampler packages andupgrades from your existing Thermo Orion sample changer are available
Description of Accessories
Model AS3000 Autosampler complete with 45-position rack electrode holder interface cable line cord pkg of (50) 50 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 28-position rack electrode holder interface cable line cord pkg of (50) 150 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 18-position rack electrode holder interface cable line cord pkg of (25) 250 ml plastic beakers and instruction manual 115V220V
Model 960 with AutoSampler 45-Position Rack Designed for 50 mL Beakers (Beakers Included)
Model 960 with AutoSampler 28-Position Rack Designed for 150 mL Beakers (Beakers Included)
Model 960 with AutoSampler 18-Position Rack Designed for 250 mL Beakers (Beakers Included)
45-Position Rack Designed for 50 mL Beakers
28-Position Rack Designed for 150 mL Beakers
18-Position Rack Designed for 250 mL Beakers
Beakers Plastic 50 mL pkg of 50
Beakers Plastic 150 mL pkg of 50 (Replaces Cat No 096S17)
Beakers Plastic 250 mL pkg of 25
Beakers Plastic 45 mL pkg of 50
Cat No
AS3050
AS3150
AS3250
96050A
96150A
96250A
ASR050
ASR150
ASR250
ASB050
ASB150
ASB250
096S22
New Series Autosamplers
AS3000
Feature
50 mL beaker sold with autosampler
150 mL beaker sold with autosampler
250 mL beaker sold with autosampler
Accuracy
Agency Approvals
Environmental Requirements
Paint Color
Description
Polypropylene Chemically resistant 42 mm diameter
Polypropylene Chemically resistant 57 mm diameter
Polypropylene Chemically resistant 68 mm diameter
plusmn 10 mm in all axes
CE UL CSA
5 to 45 degC and 20 to 80 Relative Humidity
Carbide Black
Feature
Programmable Sample Access Area
Foot Print
Height to top of Z-axis
Sample Capacity
Model AS3050
Model AS3150
Model AS3250
Computer Interface
Power Voltage
Description
187 X 70 X 475 inches (W X D X H)
2325X145X1575 inches (W X D X H)
59X37X40 cm
45 50 mL glass or plastic beaker
28 150 mL glass or plastic beaker
18 250 mL glass or plastic beaker
RS232
90-240 Vac 5060 Hz
Accessories amp Consumables
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 8
Customer Service and Support 8002251480 - 9782326015 (fax)
bull Economical Automatic Titrator - fits any budget
bull Automates - routine titrations can be done easily
bull Modular Design ndash the compact design allows flexibility and versatility
bull Superior Features - incorporates premium ROSStrade pH electrode technology
bull Printer Options - provide comprehensive record of results and methods
Cat No
095000
095001
095002
095003
095004
Description of Instruments
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSStrade Sure-Flowreg pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
950 FAST QC Titrator without line cord Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional and manual
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
Note To use with an external printer order 950DPU OR 950EPN splitter cables
The Model 950 incorporates the superior features of the patented ROSS pHtechnology into an economical yet versatile potentiometric titrator The Model 950performs AcidBase titrations including non-aqueous samples oxidation-reductionprecipitation and complexometric titrations using ion selective electrodes Automateall routine manual color end-point titrations with the Model 950 preset end-pointtechnique The Model 950 preset technique can titrate to one or two preset pH ormillivolt values to measure P amp M alkalinity of water or acidity of carbonatedbeverages The Model 950 first derivative technique offers titration to one or multipleinflection points for many analyses for example chloride in food ingredients copperin a plating bath or TAN and TBN of the petroleum products The Titrant and theentire system can be standardized automatically against an accurately weighedknown NIST or other national standards using the standardize system technique
This basic titrator is extremely simple to use just press a singlebutton to start the titration Automatic pH calibration menuleads you to perform one or two point calibration On-boardmemory stores up to 10 methods that can be recalled at thepush of a button Methods can be locked to safeguardaccidental deletion Unique to Thermo Orion titrators theAssuredAccuracytrade feature allows the gravimetric calibration of the entire dispensing system making it easy to meet ISO 9000 and GLP requirements Simply add a secondworkstation to expand your Model 950 titration capabilitiesand enhance your labrsquos productivity
Fast QCtrade Titrator
Model 950
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 9
Customer Service and Support 8002251480 - 9782326015 (fax)
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Note To use with an external printer order 950DPU OR 950EPN splitter cables
bull Ion Measurement - made easier through automation
bull Simple - self-calibrating one beaker analysis
bull Workstation Design - reduces chemical usage and reagent handling
bull KAPtrade Analysis ndash one Beaker Analysis
bull Customize - with any ionplusreg combination ion selective electrode
The Model 930 Ionalyzer System and ionplus electrodes provide fast reliable ionmeasurement with an easy-to-use precise analysis technique The exclusive KAPtrade
Analysis techniques ensure dependable performance even with the most difficultsamples Design features provide a saving in time and cost per analysis Automatedreagent handling reduces time spent preparing samples and produces less reagentwaste The Model 930 Ionalyzer workstation also holds electrodes and stirs thesample during analysis Using advanced ionplus electrodes (with Sure-Flowreg
references) measure even the dirtiest samples without additional filtration ordistillation steps Save time and money measuring such species as cyanide inplating solutions and sulfide in pulping liquors Customize to meet your specializedneeds calculate results in your choice of concentration units and report all results onthe integrated or external printer With dual channel inputs you can add anadditional workstation to expand your analysis capacity Store up to ten differentmethods for maximum productivity The Model 930 Ionalyzer also measures pHproviding additional measurement choice For example the Model 930 is ideal forboth ammonia and pH measurements in effluent KAP Analysis techniques improve
performance by adding small aliquots of a standard to thesample This self-calibrating technique performs bothelectrode calibration and sample measurement in one beakerKAP Analysis minimizes errors due to complexing agents orcomplicated sample backgrounds Choose between singleknown addition for simple measurements or double ormultiple known addition for samples with complexbackgrounds Quickly measure compounds such as chloridein food in one beaker without hazardous metal titration Verifyanalysis with spike recovery automatically performed in themultiple known addition technique Also automate other directmeasurements with the ACCUreadtrade or serial calibrationtechniques performing an entire multipoint calibration in onebeaker Providing calibration measurement and validation ofresults automatically the Model 930 Ionalyzer improvesspeed and accuracy and lowers cost per analysis
Cat No
093000
093001
093002
093003
093004
Description of Instruments
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 220V 60Hz
930 Ionalyzer without line cord Includes workstation control unit printer printer paper cables tubing instructional and manual
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 220V 60Hz
Ionalyzerreg System
Model 930
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 10
Customer Service and Support 8002251480 - 9782326015 (fax)
The chart below describes the various techniques available on Thermo Orionrsquos titrators and dispensing workstations and when they are recommended
Endpoint Analysis
First Derivative(For Model 960and Model 950)
Second Derivative(For Model 960)
Present Endpoint(For Model 960950)
KAPtrade Analysis
Multiple Known Addition(For Model 960and Model 930)
Multiple Known Subtraction(For Model 960)
Multiple Analate Addition(For Model 960)
Serial Calibration(For Model 960 930)
GAPtrade Analysis
Gran Function(For Model 960)
Gran Predict(For Model 960)
Assist Analysis
Standardize System(For Model 960)
HELP Analysis (For Model 960)
pH Read(For Model 960)
Description
Automated titration technique which calculates endpoints from the first derivative of the titration curve
Similar to first derivative but endpoints arecalculated from second derivative
Allows titration to proceed to one or two preset mV or pH values
Performs calibration and calculates sampleconcentration by adding aliquots of standard to sample
Performs calibration and calculates sampleconcentration by adding aliquots of reagentwhich reacts with sample species
Performs calibration and calculates sampleconcentration by adding aliquots of sample to astandard solution
Generates calibration curve by adding aliquotsof standard to a beaker of water and ISA
Similar to first derivative but Gran Functionsapplied to determine equivalence points
Similar to Gran Function but looks at data onone side of equivalence point only
Standardizes entire system (electrodeselectronics dispenser titrant)
Recommends the best method by adding aliquots of reagent to sample and analyzing data
For accurate pH measurements and direct ion read
When Recommended
bull Routine potentiometric titrations bull Determine poorly defined and
multiple endpoints
bull When required by industry standardsbull Eliminates false endpoint detection
bull P amp M alkalinity of water and wastewaterbull Titrations with no clearly defined endpointbull When required by industry standards
bull Measure nontitratable species ie NA+ K+ NO3
- NH3bull Complex sample matrixbull More precision required than
Standard calibration
bull No stable standard solution for ion of interest ie sulfide
bull Use for direct read of ions (calibrate and read series of samples)
bull Concentrated samplebull Viscous samples
bull Low level measurementsbull Checking electrode performance
bull Titrations with poor endpointbull Titrations with two endpointsbull Titrations with asymmetric curves
bull Slow reactionsbull Speed requiredbull Low level titrations ie Cl-
bull Highest system accuracy required
bull When unsure of what technique or measurement parameters to use
bull Automation of pH or direct ion read Can beused on autosampler
Advantage
bull Precisionbull No ambiguity in location of
endpoints
bull Precision
bull No interference from color or turbidity
bull No need for independent calibration or recalibration
bull Matrix effects minimizedbull Recovery test performed with
every sample
bull Faster than conventional titrationbull Uses less reagent than
conventional titration
bull Sample automatically diluted as part of analysis
bull Sample can be added from automatic pipet
bull Defines non-linear portion of calibration curve
bull Eliminates need to prepare standards
bull Accuracy
bull Speedbull Less reagent consumption
bull One-step standardization of all system components
bull Optimizes method
bull Automation accuracy
TechniquesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 11
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
Output
mV
Concentration
pH Range
Temperature
Power RequirementVoltageFrequency
Titration Modes
Methods Saved
Display
Variable Speed Stirring Paddle
Input
DimensionsHeightWidthDepth
CaseSplash and Chemical Resistant
Environmental Requirements5 to 45 degC and 5 to 85relative humidity
Autosampler Option
Agency Approvals
Ordering Information110 V220 VWithout Line CordWithout Printer 110 VWithout Printer 220 V960 Module
Model 960
EA 940 RS232 recorder Karl Fischer 4RS232 ports for connection to EA 940 printercomputer and balance one 15-pin parallel port
-160000 to 160000 mV
00001 to 99999
-2000 to 19999
-50 to 1050 ˚C
110120220240 VAC5060 Hz
All 930 and 950 OptionsSecond Derivative TitrationSingle Known SubtractionDouble Known SubtractionMultiple Known SubtractionMultiple Analate AdditionGran FunctionGran PredictStandardize SystemHelp AnalysispH Read
Up to Twenty
Custom color vacuumfluorescent with 40 characterprompt line
radic
Two BNC two pin tip dual bananajacks for PT-100 style ATC probe
With Tower16rdquo17rdquo18rdquo
radic
radic
Yes
CE
096000 (110V220V)
096002
Model 950
RS232 recorder Karl Fischer
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 ˚C
9 VDC line converter for110120220240 VAC5060 Hz
Preset pH EndpointPreset mV EndpointFirst Derivative Titration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip ground ATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
095000095001095002095003095004
Model 930
RS232 recorder
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 degC
9 VDC line converter for110120220240 VAC5060 Hz
Single Known AdditionDouble Known AdditionMultiple Known AdditionSerial Calibration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip groundATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
093000093001093002093003093004
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 12
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
0960KF
0607CA
0607CI
096010
096011
096014
096016
096017
096019
096021
096025
096035
096038
096039
096045
910003
0900A0
0900A1
0900A2
0GLP30
0GLP31PRT300
PRT301
55PR40
55PR49
Description of Accessories
Model 960KF Volumetric Karl Fischer Accessory Provides the hardware for performing Karl Fisher Moisture Analysis on the Model 960 Titrator Plus System Includes KF vessel with drain valve vessel top KF electrode (977900) and KF adapter stirrer with long shaft (096019) glass desiccant side arm stopper stand septum Teflon vessel O-ring plugs and O-rings
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 110 V (Use with cable 096050 for Model 960)
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 220 V (Use with cable 096050 for Model 960)
Auxilary Dispenser with tower complete with dispenser probes tubing kit interface cable dispenser base electrode holder stirrer power cord and instruction manual 115230 V
Auxilary Dispenser without tower for use with AS3000 Series Autosampler Includes dispenser probes tubing kit interface cable power cord and instruction manual 115230 V
Description of Consumables
960 Tubing Kit Includes tube and connector for working solution bottle to AUTOdispenser tube and connectors for AUTOdispenser to dispenser probe
Dispenser Probe pkg of 2 and roll of cleaning wire pkg of 1
Anti-Diffusion Dispenser Probe One dispenser probe with six replaceable tips For low-level analyses or dense titrants
Stirrer to fit electrode tower includes stirrer paddle
Stirrer Paddle to fit 096019 pkg of 3
Dip Tube with sealable cap to fit working solution bottle pkg of 6
Gas Absorption Cartridge fits top of working solution bottle Absorbs carbon dioxide and moisture Absorbent not included
AUTOdispenser Calibration Kit includes five sealable plastic vials 8 ml capacity
Bottles 475 ml amber glass for working solution pkg of 12 Req Cat No 096025
Bottles 475 ml translucent plastic for working solution pkg of 12 Req Cat No 096025
Electrode Storage Bottle pkg of 3
Description of Printers
Model 900A Thermal Printer for Models 950930 110V
Model 900A Thermal Printer for Models 950930 220V
Model 900A Thermal Printer for Models 950930 No Adapter 220V
Ink Based GLP Printer for Model 960 includes instruction manual 110 V
Ink Based GLP Printer for Model 960 includes step-down transformer instruction manual 220 V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 110V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 220V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 115 V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 220 V
Continue to next page
Accessories and ConsumablesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 13
Customer Service and Support 8002251480 - 9782326015 (fax)
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
bull AS3000 Series Autosamplers - for use with the Model 960 TitratorPLUSreg
bull Enhance Lab Productivity - automate Sample Preparation Calibrations and Standardizations
bull Increased Flexibility - interchangeable beaker racks and probe holders
bull Three Rack Sizes - (45) 50 mL (28) 150 mL or (18) 250 mL beakers
bull Quality Control - up to five rinse beakers to clean the electrodes between analyses
The new AS3000 XYZ Autosamplers are designed for use with the Model 960 TitratorPLUS Thermo Orion offers a choice in autosamplers withmultiple rack configurations to provide flexibility for high sample throughput Runtitrations or other pHISE techniques with the use of the new AS3000 seriesAutosampler overnight Additionally the probe arm assembly moves along the
X Y and Z-axes at speeds from 0 to 35 inches per second withfull control of velocity and acceleration allowing for fastersampling and analyses New Autosampler packages andupgrades from your existing Thermo Orion sample changer are available
Description of Accessories
Model AS3000 Autosampler complete with 45-position rack electrode holder interface cable line cord pkg of (50) 50 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 28-position rack electrode holder interface cable line cord pkg of (50) 150 ml plastic beakers and instruction manual 115V220V
Model AS3000 Autosampler complete with 18-position rack electrode holder interface cable line cord pkg of (25) 250 ml plastic beakers and instruction manual 115V220V
Model 960 with AutoSampler 45-Position Rack Designed for 50 mL Beakers (Beakers Included)
Model 960 with AutoSampler 28-Position Rack Designed for 150 mL Beakers (Beakers Included)
Model 960 with AutoSampler 18-Position Rack Designed for 250 mL Beakers (Beakers Included)
45-Position Rack Designed for 50 mL Beakers
28-Position Rack Designed for 150 mL Beakers
18-Position Rack Designed for 250 mL Beakers
Beakers Plastic 50 mL pkg of 50
Beakers Plastic 150 mL pkg of 50 (Replaces Cat No 096S17)
Beakers Plastic 250 mL pkg of 25
Beakers Plastic 45 mL pkg of 50
Cat No
AS3050
AS3150
AS3250
96050A
96150A
96250A
ASR050
ASR150
ASR250
ASB050
ASB150
ASB250
096S22
New Series Autosamplers
AS3000
Feature
50 mL beaker sold with autosampler
150 mL beaker sold with autosampler
250 mL beaker sold with autosampler
Accuracy
Agency Approvals
Environmental Requirements
Paint Color
Description
Polypropylene Chemically resistant 42 mm diameter
Polypropylene Chemically resistant 57 mm diameter
Polypropylene Chemically resistant 68 mm diameter
plusmn 10 mm in all axes
CE UL CSA
5 to 45 degC and 20 to 80 Relative Humidity
Carbide Black
Feature
Programmable Sample Access Area
Foot Print
Height to top of Z-axis
Sample Capacity
Model AS3050
Model AS3150
Model AS3250
Computer Interface
Power Voltage
Description
187 X 70 X 475 inches (W X D X H)
2325X145X1575 inches (W X D X H)
59X37X40 cm
45 50 mL glass or plastic beaker
28 150 mL glass or plastic beaker
18 250 mL glass or plastic beaker
RS232
90-240 Vac 5060 Hz
Accessories amp Consumables
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 8
Customer Service and Support 8002251480 - 9782326015 (fax)
bull Economical Automatic Titrator - fits any budget
bull Automates - routine titrations can be done easily
bull Modular Design ndash the compact design allows flexibility and versatility
bull Superior Features - incorporates premium ROSStrade pH electrode technology
bull Printer Options - provide comprehensive record of results and methods
Cat No
095000
095001
095002
095003
095004
Description of Instruments
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSStrade Sure-Flowreg pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
950 FAST QC Titrator without line cord Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional and manual
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
Note To use with an external printer order 950DPU OR 950EPN splitter cables
The Model 950 incorporates the superior features of the patented ROSS pHtechnology into an economical yet versatile potentiometric titrator The Model 950performs AcidBase titrations including non-aqueous samples oxidation-reductionprecipitation and complexometric titrations using ion selective electrodes Automateall routine manual color end-point titrations with the Model 950 preset end-pointtechnique The Model 950 preset technique can titrate to one or two preset pH ormillivolt values to measure P amp M alkalinity of water or acidity of carbonatedbeverages The Model 950 first derivative technique offers titration to one or multipleinflection points for many analyses for example chloride in food ingredients copperin a plating bath or TAN and TBN of the petroleum products The Titrant and theentire system can be standardized automatically against an accurately weighedknown NIST or other national standards using the standardize system technique
This basic titrator is extremely simple to use just press a singlebutton to start the titration Automatic pH calibration menuleads you to perform one or two point calibration On-boardmemory stores up to 10 methods that can be recalled at thepush of a button Methods can be locked to safeguardaccidental deletion Unique to Thermo Orion titrators theAssuredAccuracytrade feature allows the gravimetric calibration of the entire dispensing system making it easy to meet ISO 9000 and GLP requirements Simply add a secondworkstation to expand your Model 950 titration capabilitiesand enhance your labrsquos productivity
Fast QCtrade Titrator
Model 950
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 9
Customer Service and Support 8002251480 - 9782326015 (fax)
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Note To use with an external printer order 950DPU OR 950EPN splitter cables
bull Ion Measurement - made easier through automation
bull Simple - self-calibrating one beaker analysis
bull Workstation Design - reduces chemical usage and reagent handling
bull KAPtrade Analysis ndash one Beaker Analysis
bull Customize - with any ionplusreg combination ion selective electrode
The Model 930 Ionalyzer System and ionplus electrodes provide fast reliable ionmeasurement with an easy-to-use precise analysis technique The exclusive KAPtrade
Analysis techniques ensure dependable performance even with the most difficultsamples Design features provide a saving in time and cost per analysis Automatedreagent handling reduces time spent preparing samples and produces less reagentwaste The Model 930 Ionalyzer workstation also holds electrodes and stirs thesample during analysis Using advanced ionplus electrodes (with Sure-Flowreg
references) measure even the dirtiest samples without additional filtration ordistillation steps Save time and money measuring such species as cyanide inplating solutions and sulfide in pulping liquors Customize to meet your specializedneeds calculate results in your choice of concentration units and report all results onthe integrated or external printer With dual channel inputs you can add anadditional workstation to expand your analysis capacity Store up to ten differentmethods for maximum productivity The Model 930 Ionalyzer also measures pHproviding additional measurement choice For example the Model 930 is ideal forboth ammonia and pH measurements in effluent KAP Analysis techniques improve
performance by adding small aliquots of a standard to thesample This self-calibrating technique performs bothelectrode calibration and sample measurement in one beakerKAP Analysis minimizes errors due to complexing agents orcomplicated sample backgrounds Choose between singleknown addition for simple measurements or double ormultiple known addition for samples with complexbackgrounds Quickly measure compounds such as chloridein food in one beaker without hazardous metal titration Verifyanalysis with spike recovery automatically performed in themultiple known addition technique Also automate other directmeasurements with the ACCUreadtrade or serial calibrationtechniques performing an entire multipoint calibration in onebeaker Providing calibration measurement and validation ofresults automatically the Model 930 Ionalyzer improvesspeed and accuracy and lowers cost per analysis
Cat No
093000
093001
093002
093003
093004
Description of Instruments
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 220V 60Hz
930 Ionalyzer without line cord Includes workstation control unit printer printer paper cables tubing instructional and manual
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 220V 60Hz
Ionalyzerreg System
Model 930
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 10
Customer Service and Support 8002251480 - 9782326015 (fax)
The chart below describes the various techniques available on Thermo Orionrsquos titrators and dispensing workstations and when they are recommended
Endpoint Analysis
First Derivative(For Model 960and Model 950)
Second Derivative(For Model 960)
Present Endpoint(For Model 960950)
KAPtrade Analysis
Multiple Known Addition(For Model 960and Model 930)
Multiple Known Subtraction(For Model 960)
Multiple Analate Addition(For Model 960)
Serial Calibration(For Model 960 930)
GAPtrade Analysis
Gran Function(For Model 960)
Gran Predict(For Model 960)
Assist Analysis
Standardize System(For Model 960)
HELP Analysis (For Model 960)
pH Read(For Model 960)
Description
Automated titration technique which calculates endpoints from the first derivative of the titration curve
Similar to first derivative but endpoints arecalculated from second derivative
Allows titration to proceed to one or two preset mV or pH values
Performs calibration and calculates sampleconcentration by adding aliquots of standard to sample
Performs calibration and calculates sampleconcentration by adding aliquots of reagentwhich reacts with sample species
Performs calibration and calculates sampleconcentration by adding aliquots of sample to astandard solution
Generates calibration curve by adding aliquotsof standard to a beaker of water and ISA
Similar to first derivative but Gran Functionsapplied to determine equivalence points
Similar to Gran Function but looks at data onone side of equivalence point only
Standardizes entire system (electrodeselectronics dispenser titrant)
Recommends the best method by adding aliquots of reagent to sample and analyzing data
For accurate pH measurements and direct ion read
When Recommended
bull Routine potentiometric titrations bull Determine poorly defined and
multiple endpoints
bull When required by industry standardsbull Eliminates false endpoint detection
bull P amp M alkalinity of water and wastewaterbull Titrations with no clearly defined endpointbull When required by industry standards
bull Measure nontitratable species ie NA+ K+ NO3
- NH3bull Complex sample matrixbull More precision required than
Standard calibration
bull No stable standard solution for ion of interest ie sulfide
bull Use for direct read of ions (calibrate and read series of samples)
bull Concentrated samplebull Viscous samples
bull Low level measurementsbull Checking electrode performance
bull Titrations with poor endpointbull Titrations with two endpointsbull Titrations with asymmetric curves
bull Slow reactionsbull Speed requiredbull Low level titrations ie Cl-
bull Highest system accuracy required
bull When unsure of what technique or measurement parameters to use
bull Automation of pH or direct ion read Can beused on autosampler
Advantage
bull Precisionbull No ambiguity in location of
endpoints
bull Precision
bull No interference from color or turbidity
bull No need for independent calibration or recalibration
bull Matrix effects minimizedbull Recovery test performed with
every sample
bull Faster than conventional titrationbull Uses less reagent than
conventional titration
bull Sample automatically diluted as part of analysis
bull Sample can be added from automatic pipet
bull Defines non-linear portion of calibration curve
bull Eliminates need to prepare standards
bull Accuracy
bull Speedbull Less reagent consumption
bull One-step standardization of all system components
bull Optimizes method
bull Automation accuracy
TechniquesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 11
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
Output
mV
Concentration
pH Range
Temperature
Power RequirementVoltageFrequency
Titration Modes
Methods Saved
Display
Variable Speed Stirring Paddle
Input
DimensionsHeightWidthDepth
CaseSplash and Chemical Resistant
Environmental Requirements5 to 45 degC and 5 to 85relative humidity
Autosampler Option
Agency Approvals
Ordering Information110 V220 VWithout Line CordWithout Printer 110 VWithout Printer 220 V960 Module
Model 960
EA 940 RS232 recorder Karl Fischer 4RS232 ports for connection to EA 940 printercomputer and balance one 15-pin parallel port
-160000 to 160000 mV
00001 to 99999
-2000 to 19999
-50 to 1050 ˚C
110120220240 VAC5060 Hz
All 930 and 950 OptionsSecond Derivative TitrationSingle Known SubtractionDouble Known SubtractionMultiple Known SubtractionMultiple Analate AdditionGran FunctionGran PredictStandardize SystemHelp AnalysispH Read
Up to Twenty
Custom color vacuumfluorescent with 40 characterprompt line
radic
Two BNC two pin tip dual bananajacks for PT-100 style ATC probe
With Tower16rdquo17rdquo18rdquo
radic
radic
Yes
CE
096000 (110V220V)
096002
Model 950
RS232 recorder Karl Fischer
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 ˚C
9 VDC line converter for110120220240 VAC5060 Hz
Preset pH EndpointPreset mV EndpointFirst Derivative Titration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip ground ATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
095000095001095002095003095004
Model 930
RS232 recorder
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 degC
9 VDC line converter for110120220240 VAC5060 Hz
Single Known AdditionDouble Known AdditionMultiple Known AdditionSerial Calibration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip groundATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
093000093001093002093003093004
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 12
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
0960KF
0607CA
0607CI
096010
096011
096014
096016
096017
096019
096021
096025
096035
096038
096039
096045
910003
0900A0
0900A1
0900A2
0GLP30
0GLP31PRT300
PRT301
55PR40
55PR49
Description of Accessories
Model 960KF Volumetric Karl Fischer Accessory Provides the hardware for performing Karl Fisher Moisture Analysis on the Model 960 Titrator Plus System Includes KF vessel with drain valve vessel top KF electrode (977900) and KF adapter stirrer with long shaft (096019) glass desiccant side arm stopper stand septum Teflon vessel O-ring plugs and O-rings
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 110 V (Use with cable 096050 for Model 960)
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 220 V (Use with cable 096050 for Model 960)
Auxilary Dispenser with tower complete with dispenser probes tubing kit interface cable dispenser base electrode holder stirrer power cord and instruction manual 115230 V
Auxilary Dispenser without tower for use with AS3000 Series Autosampler Includes dispenser probes tubing kit interface cable power cord and instruction manual 115230 V
Description of Consumables
960 Tubing Kit Includes tube and connector for working solution bottle to AUTOdispenser tube and connectors for AUTOdispenser to dispenser probe
Dispenser Probe pkg of 2 and roll of cleaning wire pkg of 1
Anti-Diffusion Dispenser Probe One dispenser probe with six replaceable tips For low-level analyses or dense titrants
Stirrer to fit electrode tower includes stirrer paddle
Stirrer Paddle to fit 096019 pkg of 3
Dip Tube with sealable cap to fit working solution bottle pkg of 6
Gas Absorption Cartridge fits top of working solution bottle Absorbs carbon dioxide and moisture Absorbent not included
AUTOdispenser Calibration Kit includes five sealable plastic vials 8 ml capacity
Bottles 475 ml amber glass for working solution pkg of 12 Req Cat No 096025
Bottles 475 ml translucent plastic for working solution pkg of 12 Req Cat No 096025
Electrode Storage Bottle pkg of 3
Description of Printers
Model 900A Thermal Printer for Models 950930 110V
Model 900A Thermal Printer for Models 950930 220V
Model 900A Thermal Printer for Models 950930 No Adapter 220V
Ink Based GLP Printer for Model 960 includes instruction manual 110 V
Ink Based GLP Printer for Model 960 includes step-down transformer instruction manual 220 V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 110V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 220V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 115 V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 220 V
Continue to next page
Accessories and ConsumablesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 13
Customer Service and Support 8002251480 - 9782326015 (fax)
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
bull Economical Automatic Titrator - fits any budget
bull Automates - routine titrations can be done easily
bull Modular Design ndash the compact design allows flexibility and versatility
bull Superior Features - incorporates premium ROSStrade pH electrode technology
bull Printer Options - provide comprehensive record of results and methods
Cat No
095000
095001
095002
095003
095004
Description of Instruments
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSStrade Sure-Flowreg pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator with printer Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
950 FAST QC Titrator without line cord Includes workstation control unit printer printer paper ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional and manual
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 110V 60Hz
950 FAST QC Titrator without printer Includes workstation control unit ROSS Sure-Flow pH Combination electrode (8172BN) cables tubing instructional manual and line cords 220V 60Hz
Note To use with an external printer order 950DPU OR 950EPN splitter cables
The Model 950 incorporates the superior features of the patented ROSS pHtechnology into an economical yet versatile potentiometric titrator The Model 950performs AcidBase titrations including non-aqueous samples oxidation-reductionprecipitation and complexometric titrations using ion selective electrodes Automateall routine manual color end-point titrations with the Model 950 preset end-pointtechnique The Model 950 preset technique can titrate to one or two preset pH ormillivolt values to measure P amp M alkalinity of water or acidity of carbonatedbeverages The Model 950 first derivative technique offers titration to one or multipleinflection points for many analyses for example chloride in food ingredients copperin a plating bath or TAN and TBN of the petroleum products The Titrant and theentire system can be standardized automatically against an accurately weighedknown NIST or other national standards using the standardize system technique
This basic titrator is extremely simple to use just press a singlebutton to start the titration Automatic pH calibration menuleads you to perform one or two point calibration On-boardmemory stores up to 10 methods that can be recalled at thepush of a button Methods can be locked to safeguardaccidental deletion Unique to Thermo Orion titrators theAssuredAccuracytrade feature allows the gravimetric calibration of the entire dispensing system making it easy to meet ISO 9000 and GLP requirements Simply add a secondworkstation to expand your Model 950 titration capabilitiesand enhance your labrsquos productivity
Fast QCtrade Titrator
Model 950
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 9
Customer Service and Support 8002251480 - 9782326015 (fax)
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Note To use with an external printer order 950DPU OR 950EPN splitter cables
bull Ion Measurement - made easier through automation
bull Simple - self-calibrating one beaker analysis
bull Workstation Design - reduces chemical usage and reagent handling
bull KAPtrade Analysis ndash one Beaker Analysis
bull Customize - with any ionplusreg combination ion selective electrode
The Model 930 Ionalyzer System and ionplus electrodes provide fast reliable ionmeasurement with an easy-to-use precise analysis technique The exclusive KAPtrade
Analysis techniques ensure dependable performance even with the most difficultsamples Design features provide a saving in time and cost per analysis Automatedreagent handling reduces time spent preparing samples and produces less reagentwaste The Model 930 Ionalyzer workstation also holds electrodes and stirs thesample during analysis Using advanced ionplus electrodes (with Sure-Flowreg
references) measure even the dirtiest samples without additional filtration ordistillation steps Save time and money measuring such species as cyanide inplating solutions and sulfide in pulping liquors Customize to meet your specializedneeds calculate results in your choice of concentration units and report all results onthe integrated or external printer With dual channel inputs you can add anadditional workstation to expand your analysis capacity Store up to ten differentmethods for maximum productivity The Model 930 Ionalyzer also measures pHproviding additional measurement choice For example the Model 930 is ideal forboth ammonia and pH measurements in effluent KAP Analysis techniques improve
performance by adding small aliquots of a standard to thesample This self-calibrating technique performs bothelectrode calibration and sample measurement in one beakerKAP Analysis minimizes errors due to complexing agents orcomplicated sample backgrounds Choose between singleknown addition for simple measurements or double ormultiple known addition for samples with complexbackgrounds Quickly measure compounds such as chloridein food in one beaker without hazardous metal titration Verifyanalysis with spike recovery automatically performed in themultiple known addition technique Also automate other directmeasurements with the ACCUreadtrade or serial calibrationtechniques performing an entire multipoint calibration in onebeaker Providing calibration measurement and validation ofresults automatically the Model 930 Ionalyzer improvesspeed and accuracy and lowers cost per analysis
Cat No
093000
093001
093002
093003
093004
Description of Instruments
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 220V 60Hz
930 Ionalyzer without line cord Includes workstation control unit printer printer paper cables tubing instructional and manual
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 220V 60Hz
Ionalyzerreg System
Model 930
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 10
Customer Service and Support 8002251480 - 9782326015 (fax)
The chart below describes the various techniques available on Thermo Orionrsquos titrators and dispensing workstations and when they are recommended
Endpoint Analysis
First Derivative(For Model 960and Model 950)
Second Derivative(For Model 960)
Present Endpoint(For Model 960950)
KAPtrade Analysis
Multiple Known Addition(For Model 960and Model 930)
Multiple Known Subtraction(For Model 960)
Multiple Analate Addition(For Model 960)
Serial Calibration(For Model 960 930)
GAPtrade Analysis
Gran Function(For Model 960)
Gran Predict(For Model 960)
Assist Analysis
Standardize System(For Model 960)
HELP Analysis (For Model 960)
pH Read(For Model 960)
Description
Automated titration technique which calculates endpoints from the first derivative of the titration curve
Similar to first derivative but endpoints arecalculated from second derivative
Allows titration to proceed to one or two preset mV or pH values
Performs calibration and calculates sampleconcentration by adding aliquots of standard to sample
Performs calibration and calculates sampleconcentration by adding aliquots of reagentwhich reacts with sample species
Performs calibration and calculates sampleconcentration by adding aliquots of sample to astandard solution
Generates calibration curve by adding aliquotsof standard to a beaker of water and ISA
Similar to first derivative but Gran Functionsapplied to determine equivalence points
Similar to Gran Function but looks at data onone side of equivalence point only
Standardizes entire system (electrodeselectronics dispenser titrant)
Recommends the best method by adding aliquots of reagent to sample and analyzing data
For accurate pH measurements and direct ion read
When Recommended
bull Routine potentiometric titrations bull Determine poorly defined and
multiple endpoints
bull When required by industry standardsbull Eliminates false endpoint detection
bull P amp M alkalinity of water and wastewaterbull Titrations with no clearly defined endpointbull When required by industry standards
bull Measure nontitratable species ie NA+ K+ NO3
- NH3bull Complex sample matrixbull More precision required than
Standard calibration
bull No stable standard solution for ion of interest ie sulfide
bull Use for direct read of ions (calibrate and read series of samples)
bull Concentrated samplebull Viscous samples
bull Low level measurementsbull Checking electrode performance
bull Titrations with poor endpointbull Titrations with two endpointsbull Titrations with asymmetric curves
bull Slow reactionsbull Speed requiredbull Low level titrations ie Cl-
bull Highest system accuracy required
bull When unsure of what technique or measurement parameters to use
bull Automation of pH or direct ion read Can beused on autosampler
Advantage
bull Precisionbull No ambiguity in location of
endpoints
bull Precision
bull No interference from color or turbidity
bull No need for independent calibration or recalibration
bull Matrix effects minimizedbull Recovery test performed with
every sample
bull Faster than conventional titrationbull Uses less reagent than
conventional titration
bull Sample automatically diluted as part of analysis
bull Sample can be added from automatic pipet
bull Defines non-linear portion of calibration curve
bull Eliminates need to prepare standards
bull Accuracy
bull Speedbull Less reagent consumption
bull One-step standardization of all system components
bull Optimizes method
bull Automation accuracy
TechniquesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 11
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
Output
mV
Concentration
pH Range
Temperature
Power RequirementVoltageFrequency
Titration Modes
Methods Saved
Display
Variable Speed Stirring Paddle
Input
DimensionsHeightWidthDepth
CaseSplash and Chemical Resistant
Environmental Requirements5 to 45 degC and 5 to 85relative humidity
Autosampler Option
Agency Approvals
Ordering Information110 V220 VWithout Line CordWithout Printer 110 VWithout Printer 220 V960 Module
Model 960
EA 940 RS232 recorder Karl Fischer 4RS232 ports for connection to EA 940 printercomputer and balance one 15-pin parallel port
-160000 to 160000 mV
00001 to 99999
-2000 to 19999
-50 to 1050 ˚C
110120220240 VAC5060 Hz
All 930 and 950 OptionsSecond Derivative TitrationSingle Known SubtractionDouble Known SubtractionMultiple Known SubtractionMultiple Analate AdditionGran FunctionGran PredictStandardize SystemHelp AnalysispH Read
Up to Twenty
Custom color vacuumfluorescent with 40 characterprompt line
radic
Two BNC two pin tip dual bananajacks for PT-100 style ATC probe
With Tower16rdquo17rdquo18rdquo
radic
radic
Yes
CE
096000 (110V220V)
096002
Model 950
RS232 recorder Karl Fischer
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 ˚C
9 VDC line converter for110120220240 VAC5060 Hz
Preset pH EndpointPreset mV EndpointFirst Derivative Titration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip ground ATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
095000095001095002095003095004
Model 930
RS232 recorder
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 degC
9 VDC line converter for110120220240 VAC5060 Hz
Single Known AdditionDouble Known AdditionMultiple Known AdditionSerial Calibration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip groundATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
093000093001093002093003093004
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 12
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
0960KF
0607CA
0607CI
096010
096011
096014
096016
096017
096019
096021
096025
096035
096038
096039
096045
910003
0900A0
0900A1
0900A2
0GLP30
0GLP31PRT300
PRT301
55PR40
55PR49
Description of Accessories
Model 960KF Volumetric Karl Fischer Accessory Provides the hardware for performing Karl Fisher Moisture Analysis on the Model 960 Titrator Plus System Includes KF vessel with drain valve vessel top KF electrode (977900) and KF adapter stirrer with long shaft (096019) glass desiccant side arm stopper stand septum Teflon vessel O-ring plugs and O-rings
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 110 V (Use with cable 096050 for Model 960)
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 220 V (Use with cable 096050 for Model 960)
Auxilary Dispenser with tower complete with dispenser probes tubing kit interface cable dispenser base electrode holder stirrer power cord and instruction manual 115230 V
Auxilary Dispenser without tower for use with AS3000 Series Autosampler Includes dispenser probes tubing kit interface cable power cord and instruction manual 115230 V
Description of Consumables
960 Tubing Kit Includes tube and connector for working solution bottle to AUTOdispenser tube and connectors for AUTOdispenser to dispenser probe
Dispenser Probe pkg of 2 and roll of cleaning wire pkg of 1
Anti-Diffusion Dispenser Probe One dispenser probe with six replaceable tips For low-level analyses or dense titrants
Stirrer to fit electrode tower includes stirrer paddle
Stirrer Paddle to fit 096019 pkg of 3
Dip Tube with sealable cap to fit working solution bottle pkg of 6
Gas Absorption Cartridge fits top of working solution bottle Absorbs carbon dioxide and moisture Absorbent not included
AUTOdispenser Calibration Kit includes five sealable plastic vials 8 ml capacity
Bottles 475 ml amber glass for working solution pkg of 12 Req Cat No 096025
Bottles 475 ml translucent plastic for working solution pkg of 12 Req Cat No 096025
Electrode Storage Bottle pkg of 3
Description of Printers
Model 900A Thermal Printer for Models 950930 110V
Model 900A Thermal Printer for Models 950930 220V
Model 900A Thermal Printer for Models 950930 No Adapter 220V
Ink Based GLP Printer for Model 960 includes instruction manual 110 V
Ink Based GLP Printer for Model 960 includes step-down transformer instruction manual 220 V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 110V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 220V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 115 V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 220 V
Continue to next page
Accessories and ConsumablesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 13
Customer Service and Support 8002251480 - 9782326015 (fax)
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Techniques Specifications Accessories amp Consumables
Electrodes amp Solutions
Note To use with an external printer order 950DPU OR 950EPN splitter cables
bull Ion Measurement - made easier through automation
bull Simple - self-calibrating one beaker analysis
bull Workstation Design - reduces chemical usage and reagent handling
bull KAPtrade Analysis ndash one Beaker Analysis
bull Customize - with any ionplusreg combination ion selective electrode
The Model 930 Ionalyzer System and ionplus electrodes provide fast reliable ionmeasurement with an easy-to-use precise analysis technique The exclusive KAPtrade
Analysis techniques ensure dependable performance even with the most difficultsamples Design features provide a saving in time and cost per analysis Automatedreagent handling reduces time spent preparing samples and produces less reagentwaste The Model 930 Ionalyzer workstation also holds electrodes and stirs thesample during analysis Using advanced ionplus electrodes (with Sure-Flowreg
references) measure even the dirtiest samples without additional filtration ordistillation steps Save time and money measuring such species as cyanide inplating solutions and sulfide in pulping liquors Customize to meet your specializedneeds calculate results in your choice of concentration units and report all results onthe integrated or external printer With dual channel inputs you can add anadditional workstation to expand your analysis capacity Store up to ten differentmethods for maximum productivity The Model 930 Ionalyzer also measures pHproviding additional measurement choice For example the Model 930 is ideal forboth ammonia and pH measurements in effluent KAP Analysis techniques improve
performance by adding small aliquots of a standard to thesample This self-calibrating technique performs bothelectrode calibration and sample measurement in one beakerKAP Analysis minimizes errors due to complexing agents orcomplicated sample backgrounds Choose between singleknown addition for simple measurements or double ormultiple known addition for samples with complexbackgrounds Quickly measure compounds such as chloridein food in one beaker without hazardous metal titration Verifyanalysis with spike recovery automatically performed in themultiple known addition technique Also automate other directmeasurements with the ACCUreadtrade or serial calibrationtechniques performing an entire multipoint calibration in onebeaker Providing calibration measurement and validation ofresults automatically the Model 930 Ionalyzer improvesspeed and accuracy and lowers cost per analysis
Cat No
093000
093001
093002
093003
093004
Description of Instruments
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer with printer Includes workstation control unit printer printer paper cables tubing instructional manual and line cords 220V 60Hz
930 Ionalyzer without line cord Includes workstation control unit printer printer paper cables tubing instructional and manual
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 110V 60Hz
930 Ionalyzer without printer Includes workstation control unit cables tubing instructional manual and line cords 220V 60Hz
Ionalyzerreg System
Model 930
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 10
Customer Service and Support 8002251480 - 9782326015 (fax)
The chart below describes the various techniques available on Thermo Orionrsquos titrators and dispensing workstations and when they are recommended
Endpoint Analysis
First Derivative(For Model 960and Model 950)
Second Derivative(For Model 960)
Present Endpoint(For Model 960950)
KAPtrade Analysis
Multiple Known Addition(For Model 960and Model 930)
Multiple Known Subtraction(For Model 960)
Multiple Analate Addition(For Model 960)
Serial Calibration(For Model 960 930)
GAPtrade Analysis
Gran Function(For Model 960)
Gran Predict(For Model 960)
Assist Analysis
Standardize System(For Model 960)
HELP Analysis (For Model 960)
pH Read(For Model 960)
Description
Automated titration technique which calculates endpoints from the first derivative of the titration curve
Similar to first derivative but endpoints arecalculated from second derivative
Allows titration to proceed to one or two preset mV or pH values
Performs calibration and calculates sampleconcentration by adding aliquots of standard to sample
Performs calibration and calculates sampleconcentration by adding aliquots of reagentwhich reacts with sample species
Performs calibration and calculates sampleconcentration by adding aliquots of sample to astandard solution
Generates calibration curve by adding aliquotsof standard to a beaker of water and ISA
Similar to first derivative but Gran Functionsapplied to determine equivalence points
Similar to Gran Function but looks at data onone side of equivalence point only
Standardizes entire system (electrodeselectronics dispenser titrant)
Recommends the best method by adding aliquots of reagent to sample and analyzing data
For accurate pH measurements and direct ion read
When Recommended
bull Routine potentiometric titrations bull Determine poorly defined and
multiple endpoints
bull When required by industry standardsbull Eliminates false endpoint detection
bull P amp M alkalinity of water and wastewaterbull Titrations with no clearly defined endpointbull When required by industry standards
bull Measure nontitratable species ie NA+ K+ NO3
- NH3bull Complex sample matrixbull More precision required than
Standard calibration
bull No stable standard solution for ion of interest ie sulfide
bull Use for direct read of ions (calibrate and read series of samples)
bull Concentrated samplebull Viscous samples
bull Low level measurementsbull Checking electrode performance
bull Titrations with poor endpointbull Titrations with two endpointsbull Titrations with asymmetric curves
bull Slow reactionsbull Speed requiredbull Low level titrations ie Cl-
bull Highest system accuracy required
bull When unsure of what technique or measurement parameters to use
bull Automation of pH or direct ion read Can beused on autosampler
Advantage
bull Precisionbull No ambiguity in location of
endpoints
bull Precision
bull No interference from color or turbidity
bull No need for independent calibration or recalibration
bull Matrix effects minimizedbull Recovery test performed with
every sample
bull Faster than conventional titrationbull Uses less reagent than
conventional titration
bull Sample automatically diluted as part of analysis
bull Sample can be added from automatic pipet
bull Defines non-linear portion of calibration curve
bull Eliminates need to prepare standards
bull Accuracy
bull Speedbull Less reagent consumption
bull One-step standardization of all system components
bull Optimizes method
bull Automation accuracy
TechniquesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 11
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
Output
mV
Concentration
pH Range
Temperature
Power RequirementVoltageFrequency
Titration Modes
Methods Saved
Display
Variable Speed Stirring Paddle
Input
DimensionsHeightWidthDepth
CaseSplash and Chemical Resistant
Environmental Requirements5 to 45 degC and 5 to 85relative humidity
Autosampler Option
Agency Approvals
Ordering Information110 V220 VWithout Line CordWithout Printer 110 VWithout Printer 220 V960 Module
Model 960
EA 940 RS232 recorder Karl Fischer 4RS232 ports for connection to EA 940 printercomputer and balance one 15-pin parallel port
-160000 to 160000 mV
00001 to 99999
-2000 to 19999
-50 to 1050 ˚C
110120220240 VAC5060 Hz
All 930 and 950 OptionsSecond Derivative TitrationSingle Known SubtractionDouble Known SubtractionMultiple Known SubtractionMultiple Analate AdditionGran FunctionGran PredictStandardize SystemHelp AnalysispH Read
Up to Twenty
Custom color vacuumfluorescent with 40 characterprompt line
radic
Two BNC two pin tip dual bananajacks for PT-100 style ATC probe
With Tower16rdquo17rdquo18rdquo
radic
radic
Yes
CE
096000 (110V220V)
096002
Model 950
RS232 recorder Karl Fischer
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 ˚C
9 VDC line converter for110120220240 VAC5060 Hz
Preset pH EndpointPreset mV EndpointFirst Derivative Titration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip ground ATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
095000095001095002095003095004
Model 930
RS232 recorder
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 degC
9 VDC line converter for110120220240 VAC5060 Hz
Single Known AdditionDouble Known AdditionMultiple Known AdditionSerial Calibration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip groundATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
093000093001093002093003093004
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 12
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
0960KF
0607CA
0607CI
096010
096011
096014
096016
096017
096019
096021
096025
096035
096038
096039
096045
910003
0900A0
0900A1
0900A2
0GLP30
0GLP31PRT300
PRT301
55PR40
55PR49
Description of Accessories
Model 960KF Volumetric Karl Fischer Accessory Provides the hardware for performing Karl Fisher Moisture Analysis on the Model 960 Titrator Plus System Includes KF vessel with drain valve vessel top KF electrode (977900) and KF adapter stirrer with long shaft (096019) glass desiccant side arm stopper stand septum Teflon vessel O-ring plugs and O-rings
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 110 V (Use with cable 096050 for Model 960)
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 220 V (Use with cable 096050 for Model 960)
Auxilary Dispenser with tower complete with dispenser probes tubing kit interface cable dispenser base electrode holder stirrer power cord and instruction manual 115230 V
Auxilary Dispenser without tower for use with AS3000 Series Autosampler Includes dispenser probes tubing kit interface cable power cord and instruction manual 115230 V
Description of Consumables
960 Tubing Kit Includes tube and connector for working solution bottle to AUTOdispenser tube and connectors for AUTOdispenser to dispenser probe
Dispenser Probe pkg of 2 and roll of cleaning wire pkg of 1
Anti-Diffusion Dispenser Probe One dispenser probe with six replaceable tips For low-level analyses or dense titrants
Stirrer to fit electrode tower includes stirrer paddle
Stirrer Paddle to fit 096019 pkg of 3
Dip Tube with sealable cap to fit working solution bottle pkg of 6
Gas Absorption Cartridge fits top of working solution bottle Absorbs carbon dioxide and moisture Absorbent not included
AUTOdispenser Calibration Kit includes five sealable plastic vials 8 ml capacity
Bottles 475 ml amber glass for working solution pkg of 12 Req Cat No 096025
Bottles 475 ml translucent plastic for working solution pkg of 12 Req Cat No 096025
Electrode Storage Bottle pkg of 3
Description of Printers
Model 900A Thermal Printer for Models 950930 110V
Model 900A Thermal Printer for Models 950930 220V
Model 900A Thermal Printer for Models 950930 No Adapter 220V
Ink Based GLP Printer for Model 960 includes instruction manual 110 V
Ink Based GLP Printer for Model 960 includes step-down transformer instruction manual 220 V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 110V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 220V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 115 V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 220 V
Continue to next page
Accessories and ConsumablesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 13
Customer Service and Support 8002251480 - 9782326015 (fax)
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
The chart below describes the various techniques available on Thermo Orionrsquos titrators and dispensing workstations and when they are recommended
Endpoint Analysis
First Derivative(For Model 960and Model 950)
Second Derivative(For Model 960)
Present Endpoint(For Model 960950)
KAPtrade Analysis
Multiple Known Addition(For Model 960and Model 930)
Multiple Known Subtraction(For Model 960)
Multiple Analate Addition(For Model 960)
Serial Calibration(For Model 960 930)
GAPtrade Analysis
Gran Function(For Model 960)
Gran Predict(For Model 960)
Assist Analysis
Standardize System(For Model 960)
HELP Analysis (For Model 960)
pH Read(For Model 960)
Description
Automated titration technique which calculates endpoints from the first derivative of the titration curve
Similar to first derivative but endpoints arecalculated from second derivative
Allows titration to proceed to one or two preset mV or pH values
Performs calibration and calculates sampleconcentration by adding aliquots of standard to sample
Performs calibration and calculates sampleconcentration by adding aliquots of reagentwhich reacts with sample species
Performs calibration and calculates sampleconcentration by adding aliquots of sample to astandard solution
Generates calibration curve by adding aliquotsof standard to a beaker of water and ISA
Similar to first derivative but Gran Functionsapplied to determine equivalence points
Similar to Gran Function but looks at data onone side of equivalence point only
Standardizes entire system (electrodeselectronics dispenser titrant)
Recommends the best method by adding aliquots of reagent to sample and analyzing data
For accurate pH measurements and direct ion read
When Recommended
bull Routine potentiometric titrations bull Determine poorly defined and
multiple endpoints
bull When required by industry standardsbull Eliminates false endpoint detection
bull P amp M alkalinity of water and wastewaterbull Titrations with no clearly defined endpointbull When required by industry standards
bull Measure nontitratable species ie NA+ K+ NO3
- NH3bull Complex sample matrixbull More precision required than
Standard calibration
bull No stable standard solution for ion of interest ie sulfide
bull Use for direct read of ions (calibrate and read series of samples)
bull Concentrated samplebull Viscous samples
bull Low level measurementsbull Checking electrode performance
bull Titrations with poor endpointbull Titrations with two endpointsbull Titrations with asymmetric curves
bull Slow reactionsbull Speed requiredbull Low level titrations ie Cl-
bull Highest system accuracy required
bull When unsure of what technique or measurement parameters to use
bull Automation of pH or direct ion read Can beused on autosampler
Advantage
bull Precisionbull No ambiguity in location of
endpoints
bull Precision
bull No interference from color or turbidity
bull No need for independent calibration or recalibration
bull Matrix effects minimizedbull Recovery test performed with
every sample
bull Faster than conventional titrationbull Uses less reagent than
conventional titration
bull Sample automatically diluted as part of analysis
bull Sample can be added from automatic pipet
bull Defines non-linear portion of calibration curve
bull Eliminates need to prepare standards
bull Accuracy
bull Speedbull Less reagent consumption
bull One-step standardization of all system components
bull Optimizes method
bull Automation accuracy
TechniquesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 11
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
Output
mV
Concentration
pH Range
Temperature
Power RequirementVoltageFrequency
Titration Modes
Methods Saved
Display
Variable Speed Stirring Paddle
Input
DimensionsHeightWidthDepth
CaseSplash and Chemical Resistant
Environmental Requirements5 to 45 degC and 5 to 85relative humidity
Autosampler Option
Agency Approvals
Ordering Information110 V220 VWithout Line CordWithout Printer 110 VWithout Printer 220 V960 Module
Model 960
EA 940 RS232 recorder Karl Fischer 4RS232 ports for connection to EA 940 printercomputer and balance one 15-pin parallel port
-160000 to 160000 mV
00001 to 99999
-2000 to 19999
-50 to 1050 ˚C
110120220240 VAC5060 Hz
All 930 and 950 OptionsSecond Derivative TitrationSingle Known SubtractionDouble Known SubtractionMultiple Known SubtractionMultiple Analate AdditionGran FunctionGran PredictStandardize SystemHelp AnalysispH Read
Up to Twenty
Custom color vacuumfluorescent with 40 characterprompt line
radic
Two BNC two pin tip dual bananajacks for PT-100 style ATC probe
With Tower16rdquo17rdquo18rdquo
radic
radic
Yes
CE
096000 (110V220V)
096002
Model 950
RS232 recorder Karl Fischer
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 ˚C
9 VDC line converter for110120220240 VAC5060 Hz
Preset pH EndpointPreset mV EndpointFirst Derivative Titration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip ground ATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
095000095001095002095003095004
Model 930
RS232 recorder
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 degC
9 VDC line converter for110120220240 VAC5060 Hz
Single Known AdditionDouble Known AdditionMultiple Known AdditionSerial Calibration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip groundATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
093000093001093002093003093004
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 12
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
0960KF
0607CA
0607CI
096010
096011
096014
096016
096017
096019
096021
096025
096035
096038
096039
096045
910003
0900A0
0900A1
0900A2
0GLP30
0GLP31PRT300
PRT301
55PR40
55PR49
Description of Accessories
Model 960KF Volumetric Karl Fischer Accessory Provides the hardware for performing Karl Fisher Moisture Analysis on the Model 960 Titrator Plus System Includes KF vessel with drain valve vessel top KF electrode (977900) and KF adapter stirrer with long shaft (096019) glass desiccant side arm stopper stand septum Teflon vessel O-ring plugs and O-rings
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 110 V (Use with cable 096050 for Model 960)
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 220 V (Use with cable 096050 for Model 960)
Auxilary Dispenser with tower complete with dispenser probes tubing kit interface cable dispenser base electrode holder stirrer power cord and instruction manual 115230 V
Auxilary Dispenser without tower for use with AS3000 Series Autosampler Includes dispenser probes tubing kit interface cable power cord and instruction manual 115230 V
Description of Consumables
960 Tubing Kit Includes tube and connector for working solution bottle to AUTOdispenser tube and connectors for AUTOdispenser to dispenser probe
Dispenser Probe pkg of 2 and roll of cleaning wire pkg of 1
Anti-Diffusion Dispenser Probe One dispenser probe with six replaceable tips For low-level analyses or dense titrants
Stirrer to fit electrode tower includes stirrer paddle
Stirrer Paddle to fit 096019 pkg of 3
Dip Tube with sealable cap to fit working solution bottle pkg of 6
Gas Absorption Cartridge fits top of working solution bottle Absorbs carbon dioxide and moisture Absorbent not included
AUTOdispenser Calibration Kit includes five sealable plastic vials 8 ml capacity
Bottles 475 ml amber glass for working solution pkg of 12 Req Cat No 096025
Bottles 475 ml translucent plastic for working solution pkg of 12 Req Cat No 096025
Electrode Storage Bottle pkg of 3
Description of Printers
Model 900A Thermal Printer for Models 950930 110V
Model 900A Thermal Printer for Models 950930 220V
Model 900A Thermal Printer for Models 950930 No Adapter 220V
Ink Based GLP Printer for Model 960 includes instruction manual 110 V
Ink Based GLP Printer for Model 960 includes step-down transformer instruction manual 220 V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 110V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 220V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 115 V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 220 V
Continue to next page
Accessories and ConsumablesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 13
Customer Service and Support 8002251480 - 9782326015 (fax)
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Specifications
Output
mV
Concentration
pH Range
Temperature
Power RequirementVoltageFrequency
Titration Modes
Methods Saved
Display
Variable Speed Stirring Paddle
Input
DimensionsHeightWidthDepth
CaseSplash and Chemical Resistant
Environmental Requirements5 to 45 degC and 5 to 85relative humidity
Autosampler Option
Agency Approvals
Ordering Information110 V220 VWithout Line CordWithout Printer 110 VWithout Printer 220 V960 Module
Model 960
EA 940 RS232 recorder Karl Fischer 4RS232 ports for connection to EA 940 printercomputer and balance one 15-pin parallel port
-160000 to 160000 mV
00001 to 99999
-2000 to 19999
-50 to 1050 ˚C
110120220240 VAC5060 Hz
All 930 and 950 OptionsSecond Derivative TitrationSingle Known SubtractionDouble Known SubtractionMultiple Known SubtractionMultiple Analate AdditionGran FunctionGran PredictStandardize SystemHelp AnalysispH Read
Up to Twenty
Custom color vacuumfluorescent with 40 characterprompt line
radic
Two BNC two pin tip dual bananajacks for PT-100 style ATC probe
With Tower16rdquo17rdquo18rdquo
radic
radic
Yes
CE
096000 (110V220V)
096002
Model 950
RS232 recorder Karl Fischer
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 ˚C
9 VDC line converter for110120220240 VAC5060 Hz
Preset pH EndpointPreset mV EndpointFirst Derivative Titration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip ground ATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
095000095001095002095003095004
Model 930
RS232 recorder
-160000 to 160000 mV
NA
-2000 to 19999
-50 to 1050 degC
9 VDC line converter for110120220240 VAC5060 Hz
Single Known AdditionDouble Known AdditionMultiple Known AdditionSerial Calibration
Up to Ten
Custom color vacuumfluorescent with 17 characterprompt line
radic
Two BNC two pin tip groundATCpower RS232
Meter Dispenser2rdquo 16rdquo9rdquo 55rdquo75rdquo 18rdquo
radic
radic
No
CE
093000093001093002093003093004
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 12
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
0960KF
0607CA
0607CI
096010
096011
096014
096016
096017
096019
096021
096025
096035
096038
096039
096045
910003
0900A0
0900A1
0900A2
0GLP30
0GLP31PRT300
PRT301
55PR40
55PR49
Description of Accessories
Model 960KF Volumetric Karl Fischer Accessory Provides the hardware for performing Karl Fisher Moisture Analysis on the Model 960 Titrator Plus System Includes KF vessel with drain valve vessel top KF electrode (977900) and KF adapter stirrer with long shaft (096019) glass desiccant side arm stopper stand septum Teflon vessel O-ring plugs and O-rings
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 110 V (Use with cable 096050 for Model 960)
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 220 V (Use with cable 096050 for Model 960)
Auxilary Dispenser with tower complete with dispenser probes tubing kit interface cable dispenser base electrode holder stirrer power cord and instruction manual 115230 V
Auxilary Dispenser without tower for use with AS3000 Series Autosampler Includes dispenser probes tubing kit interface cable power cord and instruction manual 115230 V
Description of Consumables
960 Tubing Kit Includes tube and connector for working solution bottle to AUTOdispenser tube and connectors for AUTOdispenser to dispenser probe
Dispenser Probe pkg of 2 and roll of cleaning wire pkg of 1
Anti-Diffusion Dispenser Probe One dispenser probe with six replaceable tips For low-level analyses or dense titrants
Stirrer to fit electrode tower includes stirrer paddle
Stirrer Paddle to fit 096019 pkg of 3
Dip Tube with sealable cap to fit working solution bottle pkg of 6
Gas Absorption Cartridge fits top of working solution bottle Absorbs carbon dioxide and moisture Absorbent not included
AUTOdispenser Calibration Kit includes five sealable plastic vials 8 ml capacity
Bottles 475 ml amber glass for working solution pkg of 12 Req Cat No 096025
Bottles 475 ml translucent plastic for working solution pkg of 12 Req Cat No 096025
Electrode Storage Bottle pkg of 3
Description of Printers
Model 900A Thermal Printer for Models 950930 110V
Model 900A Thermal Printer for Models 950930 220V
Model 900A Thermal Printer for Models 950930 No Adapter 220V
Ink Based GLP Printer for Model 960 includes instruction manual 110 V
Ink Based GLP Printer for Model 960 includes step-down transformer instruction manual 220 V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 110V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 220V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 115 V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 220 V
Continue to next page
Accessories and ConsumablesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 13
Customer Service and Support 8002251480 - 9782326015 (fax)
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Cat No
0960KF
0607CA
0607CI
096010
096011
096014
096016
096017
096019
096021
096025
096035
096038
096039
096045
910003
0900A0
0900A1
0900A2
0GLP30
0GLP31PRT300
PRT301
55PR40
55PR49
Description of Accessories
Model 960KF Volumetric Karl Fischer Accessory Provides the hardware for performing Karl Fisher Moisture Analysis on the Model 960 Titrator Plus System Includes KF vessel with drain valve vessel top KF electrode (977900) and KF adapter stirrer with long shaft (096019) glass desiccant side arm stopper stand septum Teflon vessel O-ring plugs and O-rings
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 110 V (Use with cable 096050 for Model 960)
Model 607 Multi-Channel Electrode Switchbox complete with accessories Includes BNC connecting cable (060710) US standard connecting cable (060711) grounding cable (060714) RS232 interface cable (060712) dust caps (060715) and 110 VAC line converter (020120) Utilize up to six electrodes calibration values are stored when used with EA 940 or Model 960 220 V (Use with cable 096050 for Model 960)
Auxilary Dispenser with tower complete with dispenser probes tubing kit interface cable dispenser base electrode holder stirrer power cord and instruction manual 115230 V
Auxilary Dispenser without tower for use with AS3000 Series Autosampler Includes dispenser probes tubing kit interface cable power cord and instruction manual 115230 V
Description of Consumables
960 Tubing Kit Includes tube and connector for working solution bottle to AUTOdispenser tube and connectors for AUTOdispenser to dispenser probe
Dispenser Probe pkg of 2 and roll of cleaning wire pkg of 1
Anti-Diffusion Dispenser Probe One dispenser probe with six replaceable tips For low-level analyses or dense titrants
Stirrer to fit electrode tower includes stirrer paddle
Stirrer Paddle to fit 096019 pkg of 3
Dip Tube with sealable cap to fit working solution bottle pkg of 6
Gas Absorption Cartridge fits top of working solution bottle Absorbs carbon dioxide and moisture Absorbent not included
AUTOdispenser Calibration Kit includes five sealable plastic vials 8 ml capacity
Bottles 475 ml amber glass for working solution pkg of 12 Req Cat No 096025
Bottles 475 ml translucent plastic for working solution pkg of 12 Req Cat No 096025
Electrode Storage Bottle pkg of 3
Description of Printers
Model 900A Thermal Printer for Models 950930 110V
Model 900A Thermal Printer for Models 950930 220V
Model 900A Thermal Printer for Models 950930 No Adapter 220V
Ink Based GLP Printer for Model 960 includes instruction manual 110 V
Ink Based GLP Printer for Model 960 includes step-down transformer instruction manual 220 V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 110V
Ink based dot matrix 40 column printer with line cord and paper (small foot print) To use with the 960 order 0GLP05 printer cable for 950930 order 950EPN printer cable 220V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 115 V
Wide Thermal Printer To use with the 960 order 960DPU printer cable for 950930 order 950DPU printer cable 220 V
Continue to next page
Accessories and ConsumablesTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 13
Customer Service and Support 8002251480 - 9782326015 (fax)
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Accessories and Consumables
Cat No
0900A4
0GLP07
55PR45
PRT302
0GLP08
0GLP10
0GLP35
0900A6
0960AE
096ZXA
096SRT
096G12
0960PC
096050
0GLP05
960DPU
950DPU
950EPN
228154-001
224753-A01
238106-A01
DTPL20
DTPL21
DTPL22
Description of Printer Consumables
Printer Paper for Model 900A pkg of 10
Printer Paper 8 12rdquo wide pkg of 10 (Brother printer only)
Printer Paper for the 55PR pkg of 5
Printer Ribbon for PRT Printers
Printer Cassette for use with GLP Printer pkg of 10 (Brother printer only)
Printer Ribbon for use with 0GLP02 0GLP03 pkg of 1
Printer Ribbon for use with 0GLP30 and 0GLP31 pkg of 1
Printer Battery for Model 900A pkg of 1
Description of Cables
Model 960 to Mettler AE Series Balance Interface Cable
American Scientific Products Z Series or Fisher Scientific XA Series Balance Interface Cable
Model 960 to Thermo Orion Analytical Balance also 960 to Sartorius MP8 Sartorius A200S or Ohaus G160D Balance Interface Cable
Model 960 to Ohaus G120 Balance Interface Cable
IBM PC to Model 960 and EA 940 Interface Cable
Cable Connects Model 960 to 607 Switchbox
Model 960 GLP Printer and EA940 Meter Interface Cable 60rdquo long
Model 960 Cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 55PR40 amp 55PR49 printers
Model 950 and 930 splitter cable to 0GLP30 0GLP31 PRT300 amp PRT301 printers
RS232 cable from Model 940 to Model 960
Description of EPROMS and Software
56 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet
61 Rev PROM Upgrade Kit Includes five PROMS installation and instruction sheet (Required for use with the AS3000)
Data PLUS2trade is an easy to use menu-driven software (DOS based operating system) designed to collect sort format and print all of your titration data from the Model 960 only Includes only 525rdquo 35rdquo software diskettes and instruction manual
Data PLUS2trade Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable and adapter
Data PLUS2trade Upgrade Kit Includes 525rdquo 35rdquo diskettes instruction manual 0960PC interface cable adapter and Rev 61 EPROMS
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 14
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Cat No
917001
917002
9512BN
951202
951204
951006
951211
9320BN
9720BN
922006
932001
932011
652012
972001
900061
9617BN
900062
9417BN
940011
941706
941708
9780SC
9781SC
9770BN
977010
977011
9429BN
942906
9629BN
900063
900061
9409BN
940906
940909
940999
940911
9609BN
ATC Probes
Epoxy Body ATC probe for use with EA 940
Glass Body ATC probe for use with EA 940
Ammonia Analysis
Ammonia Combination Gas-sensing epoxy body electrode with BNC connector Complete with 2 pkgs of 20 loose membranes cap for loosemembranes filling solution and accessories
Internal Fill Solution for 9512 Electrode 60 mL bottle
Loose membranes for 9512 Electrode pkg of 20
Ammonia Standard (01 M NH4Cl) 475 mL bottle
Ammonia pH adjusting ISA with color indicator 475 mL bottle
Calcium Analysis
Calcium Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900100 single junction reference electrode
Calcium ionplusregsbquo Sure-Flowreg Combination Epoxy body electrode with replaceable sensing module and BNC connector
Calcium Activity Standard (01 M CaCl2) 475 mL bottle
Replacement sensing module for Model 93-20 Electrode
Calcium Ionic Strength Adjuster (ISA) 475 mL bottle
CalciumMagnesium Reagent 475 mL bottle
Replacement Sensing Module for Model 97-20 Calcium ionplus electrode
Optimum Resultstrade ldquoArdquo Filling Solution for Calcium electrode
Chloride Analysis
Chloride ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoBrdquo Filling Solution for ionplus combination electrode five 60 mL bottles
Chloride Solid-state epoxy body electrode with BNC connector Use with 900200 Double Junction reference electrode
Chloride Ionic Strength Adjuster 475 mL bottle
Chloride Activity Standard (01M NaCl) 475 mL bottle
Chloride Activity Standard (1000 ppm as Cl -) 475 mL bottle
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration use with 900200 Double Junction reference electrode
Chlorine Analysis
Residual Chlorine Combination Solid-state epoxy body electrode with BNC connector
Iodide Reagent for residual Chlorine electrode
Acid Reagent for residual Chlorine electrode
Cupric (Copper) Analysis
Cupric Solid-state epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Cupric Activity Standard 01M Cu(NO3)2 475 mL bottle
Cupric ionplus Sure-Flow Combination Epoxy body electrode with BNC Connector
Optimum Resultstrade ldquoDrdquo Filling Solution for ionplus combination electrodes
Fluoride Analysis
Optimum Results ldquoArdquo Filling Solution for ionplus combination electrodes
Fluoride Solid-state epoxy body half-cell electrode with BNC connector Use with 900100 single junction reference electrode
Fluoride Activity Standard (01M NaF) 475 mL bottle
TISAB II - Total Ionic Strength Adjustor 1 gallon
TISAB II - Total Ionic Strength Adjustor 4 x 1 gallon
TISAB III - Total Ionic Strength Adjustor (concentrated) 475 mL bottle
Fluoride ionplus Sure-Flow Solid-state Combination epoxy body electrode with BNC connector
Continue to next page
Electrodes and SolutionsTable of Contents | Applications | 960 | AS3000 | 950 | 930 | 15
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Electrodes and Solutions
Cat No
948206
9482BN
9682BN
900062
920706
930701
930710
9307BN
9707BN
900046
930711
970701
8102BN
8104BN
815600
8172BN
8165BN
9102BN
9104BN
9166SC
9172BN
930101
910104
910105
910107
910110
910199
921906
931901
931911
9319BN
9719BN
900065
971901
Lead Analysis
Lead Activity Standard [01M Pb(ClO4)2] 475 mL bottle
Lead Solid-state Combination epoxy body half-cell electrode with BNC connector Use with 900200 Double Junction reference electrode
Lead ionplusreg Sure-Flowreg Combination Epoxy body electrode with BNC connector
Optimum Resultstrade ldquoBrdquo Filling Solution for Lead electrode
Nitrate Analysis
Nitrate Activity Standard (01M) 475 mL bottle
Replacement Sensing Module for 9307 electrode pkg of 3
Nitrate Interference Suppresser 475 mL bottle
Nitrate Liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Nitrate ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoFrdquo Filling Solution for ionplus series
Nitrate Ionic Strength Adjuster (ISA) 475 mL bottle
Replacement Sensing Module for Model 97-07 ionplus combination electrode
pH Analysis
ROSStrade Combination glass pH electrode with BNC connector
ROSS Glass body rugged bulb combination pH electrode with connector general-purpose use
ROSS Epoxy body with bulb gaurd combination pH electrode with BNC connector rugged general purpose use
ROSS Sure-Flow Combination glass body pH electrode with BNC connector Recommended for all sample types especially dirty viscous-type samples
ROSS Sure-Flow Combination epoxy body pH electrode with BNC connector Recommended for soil samples viscous samples field and plant use
Glass body AgAgCl internal combination pH electrode with BNC connectorRecommended for general purpose and precision measurements
Easy-to-clean hard-nose bulb Glass body combination pH electrode for routine measurements AgAgCl internal with BNC connector
pH Electrode for use with most titrators use in thick viscous samples
Glass body AgAgCl Sure-Flow Combination pH electrode with BNC connector
For pH determinations in hydrofluoric or other acid fluorides
pH 401 buffer (color-coded pink) 475 mL bottle
pH 500 buffer (color-coded orange) 475 mL bottle
pH 700 buffer (color-coded yellow) 475 mL bottle
pH 1001 buffer (color-coded blue) 475 mL bottle
pH ldquoAll in Onerdquo buffer kit includes one pint bottle of the 401 700 1001 buffers electrode storage solution 475 mL and electrode storage bottle
Potassium Analysis
01M KCl Standard 475 mL bottle
Replacement Sensing Module for 9319 Electrode
Ionic Strength Adjuster 475 mL bottle
Potassium liquid membrane PVC body electrode with two sensing modules and BNC connector Use with 900200 Double Junction reference electrode
Potassium ionplus Sure-Flow Combination Epoxy body electrode with BNC connector
Optimum Results ldquoErdquo Filling Solution for Potassium electrode
Replacement Sensing Module for Model 97-19 ionplus combination electrode
Continue to next page
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 16
Customer Service and Support 8002251480 - 9782326015 (fax)
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Electrodes and Solutions
Cat No
800300
800500
810007
900100
900200
650700
8411BN
8611BN
841111
900010
841109
841101
841113
9342BN
654201
654202
654203
654204
654205
900001
900011
9164SC
9416BN
948207
951011
9678BN
977010
977011
977900
090048
9780SC
9781SC
9778SC
Reference Electrodes
ROSStrade Sure-Flowreg Reference Electrode Glass body with pin-tip connector For all sample types Use with ROSS Model 8101 pH Sensing Half Cell and ROSS Model 8411 Sodium Sensing Half Cell
ROSS General purpose reference pin-tip connector for use with ROSS Model 8101 pH Sensing Half Cell
3M KCl filling solution used with all ROSS pH Electrodes five 60 mL bottles
Single Junction Epoxy Body AgAgCl internal easy-to-clean sleeve junction The recommended reference electrode for precise pH measurement and for many ISE measurements Shipped with 900001 Filling Solution
Double junction epoxy body easy-to-clean sleeve junction Recommended for all ISE measurements Shipped with two filling solutions 900002 and 900003 uses a variety of filling solutions
Sodium Analysis
Sodium Standard Solution three 475 mL bottles (1M NaCl with ISA) one 475 mL Sodium ISA and instruction sheet
ROSStrade Sodium Half-cell glass body electrode with BNC connector includes one bottle each of Sodium Reconditioning Solution (841113)Sodium ISA (841111) Sodium Known Addition Standard (841109) Sodium Standard 1000 ppm (841108) Reference Electrode Filling Solution(900010) instruction manual and application sheet Use with ROSS Sure-Flow Reference Electrode Cat No 800300
ROSS Sure-Flow Sodium Combination glass electrode with BNC connectorIncludes the same accessories as Cat No 8411BN
Ionic Strength Adjuster 475 mL bottle
Internal Fill Solution (2M NH4Cl) For use with 8003 or 9002 Reference Electrode when used with 8411 Sodium Electrode and for use with 8611Combination Sodium Electrode (five 50 mL bottles) Recommended fill solution for sodium measurements above 02 ppm (10-5 M)
Known Addition Standard (1000 ppm Na+ for sodium analysis plusmn 00435 M Na+ with ISA) 475 mL bottle
Sodium Electrode Storage Solution 475 mL bottle
Reconditioning Solution for sodium electrodes 9811 8411 and 8611
Surfactant Analysis
Surfactant Electrode with BNC connector includes Hyaminereg 1622 005M (475 mL) Sodium Lauryl Sulfate standard 001M (60 mL) SampleAdditive (475 mL) and instruction manual Use with 900200 Double Junction reference electrode
Hyamine 1622 titrant 005M 475 mL bottle
Sodium Lauryl Sulfate 001M (SLS) standard 60 mL
Sample Additive diluted Tritonreg X-100 475 mL
Non-Ionic Surfactant Reagent 475 mL bottle
Non-Ionic Surfactant Titrant 475 mL bottle
Special Tests and Analysis
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of less than 02 M
Internal Fill Solution for 9678 Electrode Five 60 mL bottles Use for samples with total ionic strength of greater than 02 M
AgAgCl Glass Combination Electrode for many titrators or vessel requiring standard tapered joint
SilverSulfide Solid-state epoxy body electrode BNC connector Use with 900200 Double Junction reference electrode
Sulfate Standard (01M Na2SO4) 475 mL bottle
Alkaline Reagent (10M NaOH) 475 mL bottle
Redox Sure-Flow Combination easy-to-clean junction epoxy body electrode with BNC connector Recommended for dirty viscous or oily samples sample fill solution included
Iodide Reagent five 60 mL bottles
Acid Reagent 475 mL bottle
Glass Karl Fischer Double Platinum Electrode (KF adapter 090048 required)
Karl Fischer Adapter
Combination Silver Billet Electrode for use in silver as well as chloride titration
Silver Billet Half-Cell for silver as well as chloride titration
Glass Combination RedoxORP for Redox titrations
Table of Contents | Applications | 960 | AS3000 | 950 | 930 | 17
Customer Service and Support 8002251480 - 9782326015 (fax)
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Blending Volumetric Karl Fischer Titrator
bull Sample Blending at 7500 rpm - complete moisture extraction from sample into solution with little or no sample preparation
bull 50 ppm to 100 Moisture Measurement Range - handle wide range of sample moisture levels with one instrument
bull Large 750 ml Titration Vessel - allows multiple sample analyses to be run using same solvent(s)
bull ldquoSEARCHrdquo Titration Mode - find the optimum blending time for new samples with unknown moisture levels
bull High Precision Titrant Delivery System - uninterrupted titrant delivery system with peristaltic pump and internal calibration menu for validation
bull Water Jacket Vessel - use with circulating bath to help warm solvent enhances moisture extraction in difficult samples
Combine the standard technique of Karl Fischer moisture analysis with a high speedblender revolving at 7500 rpm and you have the TURBO2 This technique eliminatesthe problem of moisture loss or gain associated with standard sample preparationprocedures When linked to an analytical balance the TURB02 becomes a semi-automatic analyzer capable of handling a continuous throughput of samples Toaccommodate a wide range of materials a large access port in the vessel top platepermits the introduction of samples up to 28 mm (1-18rdquo) in diameter In additionthe end-point detection electrode is built into the vessel sidewall giving it completeprotection from the movement of solids during blending Electronic monitors andsafety interlocks ensure that the user is protected from unsafe instrument operationThe TURBO2 is an excellent way to analyze moisture in pharmaceutical
confectionery or solid samples that typically require a lot ofsample preparation Sample preparation has been a greatsource of error in moisture determination in pharmaceuticalproducts such as tablets gelcaps or caplets The TURB02 willblend the sample extract and analyze the moisture in thesame vessel then printout a report containing resultsmethods amp statistics for FDA compliance Simply weigh andintroduce any solid or semi-solid sample such as tablets pillscandy or gum into the vessel and obtain an accurate moistureresult in minutes
Cat No
319050001
319050000
319015012
319045010
319050012
319050014
319050016
319050018
319050020
319050024
319050026
319050028
319050030
319050046
Description of Instruments
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
TURBO2sbquo Blending Volumetric Karl Fischer Titrator Complete with built-in printer 750 mL titration vessel dual RS-232 interface line cord spare silicone pump tubing and extra roll of printer paper 220V
Description of Accessories and Consumables
TURBO2 Drying Tubes for protection against moisture ingress emission pkg of 3
TURBO2 Printer Paper Rolls pkg of 3
TURBO2 750 mL Glass Titration Vessel
TURBO2 Platinum End-Point Detection Electrode
TURBO2 Blender Drive Belt
TURBO2 Water-Jacketed Titration Vessel
TURBO2 Silicone Pump Tubing 10 mm bore pkg of 5
TURBO2 Marprene Pump Tubing 10 mm bore pkg of 5
TURBO2 Shaft Seal Replacement Kit
TURBO2Teflon Stopper and Teflon Encapsulated O-Ring
TURBO2 35 Ft Extension Cable From Console to Titration Vessel
TURBO2 Maintenance and Consumables Kit
TURBO2reg
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 18
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
bull Broad Operating Range - 50 ppm to 100 moisture
bull Special Reagent Delivery - stepper motor-controlled high precision peristaltic pump
bull Unique Glass-to-Glass Vessel - sealing design ensures there is always a moisture tight seal to the reaction vessel no rubber gaskets that can be attacked by organic solvents
bull RS232 Interfaces - connection with balances and computers
bull Built-in Thermal Printer - hard copy printout provides a comprehensive record of results method and statistics
bull Visible Bar Graph ndash easily indicates vessel solution moisturestatus from across the laboratory
Cat No
319045001
319045000
319015012
319016000
319016400
319016800
319017200
319045010
319045012
319045046
319050030
Description of Instruments
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 105-120 VAC 50-60 Hz
Model AF8 Karl Fischer Volumetric Titrator Complete with built-in printer large amp small titration vessels small vessel adaptor dual RS-232 interface large amp small stir bars reagent amp waste bottles spare silicone pump tubing and extra roll of printer paper 210-240 VAC 50-60 Hz
Description of Accessories
AF8 Drying Tubes for protection against moisture ingress and sulfur dioxide emission pkg of 3 (Also fits AF5 KF Titrator)
AF8 Small Titration Vessel 100 mL capacity (Also fits AF5 KF Titrator)
AF8 Large Titration Vessel 275 mL capacity (Also fits AF5 KF Titrator)
AF8 Silicone Pump Tubing 10 mm bore pkg of 5
AF8 Marprene Pump Tubing 10 mm bore pkg of 5
AF8 Printer Paper rolls pkg of 3
AF8 Platinum Electrode Module for titration end-point and solution level detection
AF8 Maintenance and Consumables Kit
AF8 35 Ft Extension Cable From Console to Titration Vessel
The Model AF8 sets international standards for rapid determination of moisture in awide range of materials Push button convenience with the highest accuracy andprecision are all designed into the Model AF8 Operating reagent solvent and wastecontainers are plumbed directly to the titration vessel creating a fully sealedchemical handling system The Model AF8rsquos peristaltic pump unique continuoustitrant dispensing system eliminates the inconvenience of refilling burettes Themodular design has the advantage of keeping corrosive chemicals away from theelectronics providing maximum long-term reliability A top-entry opening of thevessel can be opened to the width of a syringe needle for liquids or wider toaccommodate solid samples up to 23 mm across The complete titration procedurefrom the introduction of a sample to the presentation of results is carried out by amicroprocessor-control led routine which can be pre-programmed by the operatorto optimize conditions best suited to the particular material being analyzed
Calibration confidence is assured because thestandardization routine automatically rejects flawed resultsStatistics can be performed on up to 25 sequential samplesand may calculate the mean moisture level standarddeviation the coefficient of variance and the number ofsamples analyzed An extract time can be programmed tooccur between adding the sample to the vessel and carryingout the titration There is a choice of two modes for sampleanalysis The more common option is ldquosample onlyrdquo wheremiscible liquids or soluble solids are titrated directly afteraddition to the vessel The ldquobackgroundrdquo mode is most usefulfor insoluble solids where a delayed titration is necessary tofully extract the enclosed moisture
Volumetric Karl Fischer Titrator
Model AF8
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 19
Customer Service and Support 8002251480 - 9782326015 (fax)
Specifications Accessories amp Consumables
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
bull Fastest Coulometric Titrator in the Industry - 20000 micrograms (20 mg) of water titrated per minute - (AF7 high current mode)
bull Completely Sealed Chemical Handling System - integral pump controlled from keypad easy safe replenishment of reagents without opening vessel to environmental humidity (AF7)
bull Instrument monitoring of anolytecatholyte life detecting and current generating electrodes - no need for operator monitoring (AF7 amp AF7LC)
bull Ion-permeable membrane separating anode and cathode chambers - eliminates the problem of clogged ceramic disks (AF7 amp AF7LC)
bull User-prompted methods with simple YESNO or numeric data entry - up to three methods stored in memory - (AF7 amp AF7LC)
bull Built-in GLPdoctrade printer - provides comprehensive record of results methods and statistics (AF7 amp AF7LC)
Utilizing the extremely accurate technique of coulometric iodine generation Thermo Orion coulometric titrators take moisture measurement to new limits ofperformance within a wide measuring range of 1 ppm to 100 H2O The Model AF7is a universal titrator for measuring both high and low moisture while the ModelAF7LC is specifically designed for optimum performance at low moisture levelsThese two titrators make coulometric titrations a routine measurement techniquegiving the user reliable results with unmatched speed and accuracy The AF7 is theuniversal answer for the widest range of moisture analyses offering coulometricaccuracy and precision at volumetric titrator speed You can even use the samesample size as you would for a volumetric titration The AF7rsquos flexibility is reflected inits ability to perform coulometric titrations at both low and high currents The AF7titration vessel has exceptionally large-area platinum electrodes which when usedwith high conductivity reagents provides the current necessary to operate at thetitration rate of 20 mg per minute analysis of water the typical rate of volumetrictitrators Reagent handling (AF7) titration control and auxiliary commands areclearly defined on the keypad zone
The AF7LC performs sample analyses in the 10 ppm moisture range routinely andcan operate at 1 ppm with CVrsquos of 03 It is an absolute method which eliminatesthe need for calibration of reagents Instrument set-up and titrations are simple toperform - just press the YESNO keys or enter numeric variables in response to
automatically generated questions on the 2 x 20 characterliquid crystal display Each entry is monitored out-of-rangeentries are rejected and the acceptable range is displayedThe ability to program and store up to three titration methods - eliminates the need to re-enter analysis parameters each time the instrument is turned on Titrationsare fully automatic with continuous indication of theirprogress The rate of titration and accumulated water analyzedare shown on the display and are regularly updated Themoisture status in the vessel is continuously presented on abar graph display Suspect results are flagged and ifrequested can be deleted from the final statisticalcalculations Interfaces directly with a compatible analyticalbalance making it possible to semi-automate the samplehandling process thus eliminating weight entry errors TheAF7LC vessel is compact and is specifically designed forrepetitive sample analysis at low moisture concentrations The use of ground glass joints completely eliminates moistureingress permitting the user to produce excellent CVrsquos whenworking at or near detection limits
Model AF7 amp AF7LC
Coulometric Karl Fischer Titrator
Model AF7
Model AF7LC
Table of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 20
Customer Service and Support 8002251480 - 9782326015 (fax)
Description of Instruments Accessories amp Consumables
Accessories amp Cables Specifications
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Cat No
319035001
319035002
319040001
319040000
319035008
319035010
319035012
319035014
319035016
319035018
319035020
319035022
319035024
319035026
319035028
319035029
319035030
319035032
319035034
319035036
319035046
319035030
319035032
319035034
319040008
319040010
319040012
319040014
319040016
319040020
319040022
319040046
Description of Instruments
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7 Karl Fischer Coulometric Titrator complete with special highlow current titration vessel and electrodes built-in vessel filldrain pumping system built-in printer (2) reagent and (2) waste bottles dual RS-232 interface and accessory kit 210-240 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 105-120 VAC 50-60 Hz
Model AF7LC Karl Fischer Coulometric Titrator complete with low current titration vessel built-in printer siphon bottle and funnel dual RS-232C interface and accessory kit 210-240 VAC 50-60 Hz
Description of Model AF7Accessories amp Consumables
AF7 Titration Vessel including anode cathode sensing electrode membrane kit stirrer bar and ring outer anode chamber inner cathode chamber and upper clamp ring
AF7 Anode Electrode
AF7 Cathode Electrode
AF7 End-Point Sensing Electrode
AF7 Titration Vessel Outer Chamber
AF7 Titration Vessel Inner ChamberTop Plate
AF7 Membrane Kit Includes one membrane and two O-rings
AF7 Cone Adapter for Anode amp End-Pt Electrode
AF7 Cone Adapter for Cathode Electrode
AF7 Cone Adapter for Vessel Outer Chamber (Anode FillDrain Cone)
AF7 Cone Adapter for Vessel Inner Chamber (Cathode FillDrain Cone)
AF7 Cone Adapter Washer pkg of 10
AF7 Desiccant Tubes pkg of 3
AF7 Titration Vessel Septum Discs pkg of 10
AF7 Printer Paper Rolls pkg of 3
AF7 Bottle Cap Assembly
AF7 Maintenance and Consumables Kit
Description of Model AF7LCAccessories amp Consumables
AF7LC Desiccant Tubes pkg of 3
AF7LC Titration Vessel Septum Discs pkg of 10
AF7LC Printer Paper Rolls pkg of 3
AF7LC Titration Vessel complete
AF7LC Anode Electrode includes anode electrode retaining cap assembly
AF7LC Vessel Inner ChamberCathode Electrode Includes inner chamber for catholyte cathode electrode and membrane mounted in membrane clamp assembly with O-ring
AF7LC End-Point Sensing Electrode
AF7LC Titration Vessel Outer Chamber
AF7LC Titration Vessel Top Plate
AF7LC Membrane Kit Includes one membrane mounted in membrane clamp assembly and O-ring
AF7LC Maintenance and Consumables Kit
Accessories and ConsumablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 21
Customer Service and Support 8002251480 - 9782326015 (fax)
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Cat No
319018201
319018202
225205-001
225206-001
225207-001
225208-001
225209-001
225210-001
225302-001
225303-001
225304-001
225305-001
225306-001
319035038
319035039
319035040
319035043
319035045
0KFDPU
0KFEPN
Description of Karl Fischer Moisture Vaporizer Accessory
Moisture Vaporizer extracts the moisture present in solid and other complex samples A built-in air pump introduces the vaporized moisture into the KF vessel for titration complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 110 VAC
Moisture Vaporizer complete with drying oven air pump instruction manual power cord and AF7 AF7LC and AF8 adapter connections 220 VAC
Glass sample stopper
Desiccant drying tubes
Inner drying tube
PTFE outlet tube
Sealing washer kit
Sample boat
Sample positioner assembly
Glass stopper with clip
Inlet tube assembly
Glass end module
AF8 PTFE vessel stopper
Description of Karl Fischer Balance and Printer Cables
Thermo OrionSartoriusOhaus G Series Balance Interface Cable
Ohaus AP Series Balance Interface Cable
Mettler AE Series Balance Interface Cable
Mettler AT Series Balance Interface Cable
Denver AA Series Balance Interface Cable
Karl Fischer to 55PR40 and 55PR49 Printer Cable
Karl Fischer to GLP30 and GLP 31 Printer Cable
Accessories and CablesTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 22
Customer Service and Support 8002251480 - 9782326015 (fax)
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Titration Method
Titration SpeedHigh CurrentLow Current
Moisture Range
Precision
End Point Potential
Calibration Range
End-Point TimeLevel
Background Correction
Factor Range
Blank Range
Programmable Methods
Result Unitppm - - mg
Display LCD 2 lines x 20 characters
Keyboard
Printer (Internal)
StatisticsUp to 25 Tests
Stirrer Speeds
Interfaces(2) RS232 for Balance and Computer
Balance RecognitionThermo Orion MettlerSartorius Ohaus Shimadzu AampDOertling Denver
Vessel Capacity
Reagent Handling
Dimensions
Electronic Console
Agency Approval
Ordering Information110V220V
TURBO2
Volumetric
50 ppm to 100 H2O
05 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods2 default method
radic
radic
Membrane 18-function
32 character thermal
radic
1000 to 7500 rpm
radic
radic
750 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319050001319050000
Model AF8
Volumetric
50 ppm to 100 H2O
04 at 25 mg H2O
Variable
1 to 100 mg H2O
1 to 30 seconds
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
Membrane 22-function
32 character thermal
radic
200 to 1400 rpm
radic
radic
100275 mL
Peristaltic Pump
H W D27 cm 23 cm 35 cm105 in 9 in 137 in
20 cm 37 cm 34 cm8 in 15 in 14 in
CE
319045001319045000
Model AF7
Coulometric
20 mgmin2 mgmin
1 ppm to 100 H2O
07 at 10 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 100 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Built in Pump
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319035001319035002
Model AF7LC
Coulometric
NA2 mgmin
1 ppm to 100 H2O
03 at 1 mg H2O
Fixed
0 to 50 microgmin
radic
01 to 100
0 to 10 mg
3 stored methods1 default method
radic
radic
24-function
24 character thermal
radic
200 to 1000 rpm
radic
radic
150200 mL
Manual fill amp Drain
H W D54 cm 33 cm 24 cm21 in 13 in 9 in
CE
319040001319040000
SpecificationsTable of Contents | Applications | Turbo2 | AF8 | AF7AF7LC | 23
Customer Service and Support 8002251480 - 9782326015 (fax)
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Minimum Order RequirementsThe minimum Dealer order requirement is $225 for Thermo Orion products(minimum Customer order is $40) An ldquoorderrdquo is considered to be a purchase orderfor products to be shipped to a single location International minimum orderrequirements may vary Contact your Thermo Orion International Customer ServiceSpecialist for details
Drop Shipments in US and CanadaDrop shipments for Thermo Orion Dealers will be made at a 5 penalty to currentdealer discount (5 loss of discount) for the items to be shipped Standard dropshipment orders will be shipped within five (5) business days of the order datesubject to stock availability For faster processing see rush orders below Dropshipment is only available to US and Canadian destinations
Rush OrdersCustomers and Dealers in the US Rush orders received before 12 Noon EasternTime will be shipped the same day Rush orders received after 12 Noon EasternTime will be shipped the next business day Customers and Dealers in CanadaRush orders will be shipped within two (2) business days Customers and Dealersoutside the US and Canada Contact your Thermo Orion International CCS for rushorder scheduling All rush orders carry a $50 incremental charge per order FOBBeverly Freight charges are prepaid and added or freight collect All rush orderprocessing is subject to stock availability
Restocking ChargePermission to return new excess inventory must be obtained prior to returnPhone 8002251480 or 9782326000 Fax 978232-6015 (US and Canada)or 978232-6031 (Outside US and Canada) If any item is authorized to bereturned for credit as a result of an incorrect purchase without a reorder a 25restocking charge of the price paid for the product will be made (InternationalCustomerrsquos restocking fee of 25 will be off the International price) Only new (in-the-box) goods may be returned within 30 days of shipment from Thermo OrionOlder items 9-digit parts and discontinued items cannot be returned for credit
Short ShipmentsThermo Orion must be notified within 30 days of receipt of invoice of any item orbilling discrepancies All substantiated claims of short shipments will be remediedby a credit memo and a new order placed for short shipment Any shipmentdiscrepancy claimed after 30 days of invoice date will not be honored and creditwill not be issued by Thermo Orion
To Return GoodsPermission to return merchandise purchased from Thermo Orion Beverly must be obtained prior to return Contact within 30 days of receipt of goods for a return authorization numberThermo Orion Toll Free 8002251480500 Cummings Center Phone 9782326000Beverly MA 01915 Fax 9782326015 (US amp Canada)
Fax 9782326031 (Outside US amp Canada)
Hazardous MaterialsSome materials are designated corrosive andor oxidizer by DOT and IATA SomeThermo Orion materials may require special labeling and handling Carriers mayadd additional freight charges for handlingtransporting these materialsConsolidating such material with other products may be prohibited Additionalfreight charges are billed to you per FOB terms Be sure to advise Thermo Orion ofshipping instructions for these hazardous materials to reduce your freight costs
Force MajeureThermo Orion shall not be liable for failure to perform or for delay in performancedue to fire flood strike or other labor difficulty act of God act of anygovernmental authority or of the purchaser riot embargo fuel or energy shortagewrecks or delays in transportation inability to obtain necessary labor materials ormanufacturing facilities from usual sources or due to any cause beyond itsreasonable control In the event of a delay in performance due to any such causethe date of delivery or time for completion of performance will be extended by aperiod of time reasonably necessary to overcome the effect of such delay
Approximate Shipping Weights
Instruments and Accessories
010600 010800 011000 011200 011400 011600 011800 20 lb09 kg
088100 088101 089100 089101 30 lb15 kg
010502 011502 012502 0210A2 0230A2 0250A2 0290A2 0410A2 0420A2 0520A2 0525A2 0607CA 0607CI 0610A2 0630A2 0650A2 PRT300 PRT301 PRT303 PRT304 rflinktrade 50 lb23 kg
0710A2 0720A2 0920A2 60 lb27 kg
All meter packages (except those listed above) for models 105 115 145 125 150 210A+ 230A+ 250A+ 290A+ 410A+ 420A+ 520A+ 525A+ 610A+ 620A+ 710A+ 720A+ 900A 920A+ 0PBLSK 026AKT 70 lb31 kg
All meter packages (except those listed above) for models 128 130 130A 131S 135 135A 136S 162A 260A 261S 265A 266S 310 320 330 350 370 535A 550A 555A 810 830 830A 835A 835 850 862A 55PR40 55PR49 80 lb36 kg
030100 OGLP02 OGLP03 120 lb55 kg
0GLP30 0GLP31 130 lb59 kg
SensorLinkreg systems PCM series card and electrode rflink 30 lb14 kg
DataPLUS2trade software 02 lb008 kg
Cahnreg microbalances C-33 C-34 C-35 250 lb114 kg
AS3000 Series Autosamplers 60 lb27 kg
094000 17 lb773 kg
093000 093001 095000 095001 30 lb1364 kg
096000 096002 43 lb1955 kg
096010 096011 17 lb773 kg
0960S1 0960S2 30 lb1364 kg
319035001 319035002 31904000 31904001 45 lb2045 kg
319045000 3190485001 319050000 319050001 80 lb3636 kg
319018201 319018202 16 lb64 kg
Electrodes and Accessories
Series 61 71 80 81 82 90 91 92 93 94 96 97 and 98 electrodes each 15 lb07 kg
Series 93 and 97 modules each 05 lb02 kg
Series 95 electrodes each 30 lb14 kg
Series 100 cells 800 probes 20 lb09 kg
Standardizing Solutions
Solutions 475 mL 15 lb07 kg
Solutions gallon 110 lb50 kg
Solutions 5 x 60 mL 10 lb04 kg
Solutions 4 x gallon 320 lb150 kg
Solutions 12 x 475 mL 180 lb84 kg
Standard kits 18 lb08 kg
Reagents
Titrants 51 lb23 kg
Standards 18 lb08 kg
Terms and ConditionsTable of Contents | 24
Customer Service and Support 8002251480 - 9782326015 (fax)
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
period of twenty-four (24) months from the date of purchase by the user or thirty (30) months from the date of shipment from Thermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accident alteration misuse or abuse
Waterproof meters (Models 630 635 830A 835A 260A 261S265A 266S 130A 131S 135A 136S 1230 142 and 842)Conductivity meters (Models 105Aplustrade 115Aplus 125Aplus145Aplus 150Aplus and 162A) pHuture MMStrade meters (Models 535A 555A) pHConductivity meter (Model 550A)Dissolved Oxygen meters (Models 810Aplus 850Aplus and 862A)are warranted to be free from defects in material and workmanshipfor a period of thirty-six (36) months from the date of purchase bythe user or forty-two (42) months from date of shipment fromThermo Orion whichever is earlier provided use is in accordancewith the operating limitations and maintenance procedures in theinstruction manual and when not having been subjected to accidentalteration misuse or abuse
DataCOLLECTtrade carry an ldquoout-of-boxrdquo warranty Should they fail towork when first used contact Thermo Orion immediately forreplacement
Thermo Orion Meter Electrode Analytical System AccessoriesSolutions AQUAfast Test Strips AQUAfast II and IV Reagent Kits andaccessories Series 800 Dissolved Oxygen Probe Membranes andCahn Balance Accessories such as cables printers and lineadapters carry an ldquoout-of-boxrdquo warranty Should they fail to workwhen first used contact Thermo Orion immediately for replacementShould Thermo Orion Solutions or Buffers be unusable when firstldquoout-of-boxrdquo contact Thermo Orion immediately for replacement
For products not listed in this warranty statement please visit ourwebsite thermoorioncom
THE WARRANTIES DESCRIBED ABOVE ARE EXCLUSIVE AND IN LIEUOF ALL OTHER WARRANTIES WHETHER STATUTORY EXPRESS ORIMPLIED INCLUDING BUT NO LIMITED TO ANY IMPLIED WARRANTYOF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSEAND ALL WARRANTIES ARISING FROM THE COURSE OF DEALING ORUSAGE OF TRADE THE BUYERrsquoS SOLE AND EXCLUSIVE REMEDY ISFOR REPAIR OR REPLACEMENT OF THE NON-CONFORMINGPRODUCT OR PART THEREOF OR REFUND OF THE PURCHASE PRICEBUT IN NO EVENT SHALL THERMO ORION (ITS CONTRACTORS ANDSUPPLIERS OF ANY TIER) BE LIABLE TO THE BUYER OR ANY PERSONFOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIALDAMAGES WHETHER THE CLAIMS ARE BASED IN CONTRACT IN TORT(INCLUDING NEGLIGENCE) OR OTHERWISE WITH RESPECT TO ORARISING OUT OF THE PRODUCT FURNISHED HEREUNDER
REPRESENTATION AND WARRANTIES MADE BY ANY PERSONINCLUDING ITS AUTHORIZED DEALERS REPRESENTATIVES ANDEMPLOYEES OF THERMO ORION WHICH ALTER OR ARE IN ADDITIONTO THE TERMS OF THIS WARRANTY SHALL NOT BE BINDING UPONTHERMO ORION UNLESS IN WRITING AND SIGNED BY ONE OF ITS OFFICERS
Note For in- or out-of-warranty repair or service contact Thermo Orion Technical Service (or its authorized dealer outside the United States and Canada) Technical Service will issue a Return Authorization (RA) for all repair services You must have an Thermo Orion RA prior to returningforwarding any product to Thermo Orion
The Thermo Orion warranty covers failures due to manufacturerrsquos workmanship or materialdefects from the date of purchase by the user User should return the warranty card to Thermo Orion and retain proof of purchase Warranty is void if product has been abusedmisused or repairs attempted by unauthorized persons
Warranties herein are for product soldinstalled by Thermo Orion or its authorized dealers
Any product sold by a US or Canadian distributor must be returned to Thermo Orion for anywarranty work A Return Authorization Number must be obtained from Thermo OrionLaboratory Technical Service before returning any product for in-warranty repair or replacement
In the event of failure within the warranty period Thermo Orion will at Thermo Orionrsquos optionrepair or replace product not conforming to this warranty There may be additional chargesincluding freight for warranty service performed in some countries For service call Thermo Orion (or its authorized dealer outside the United States and Canada) Thermo Orionreserves the right to ask for proof of purchase such as the original invoice or packing slip
Laboratory pH Meters (Models 611 and 301) SensorLinkreg PerpHecTreg pHISE MeterspHuturetrade pH Meters (Models 610 and 620) Sagetrade Pumps Cahnreg Balances 930 Ionalyzertrade950 ROSStrade FAST QCtrade Titrator 960 Titrator PLUSreg Karl Fischer Titrators Autosamplers Liquid Handling Devices pHuture Conversion Box Wine Mastertrade 607 Switchbox rf linktradeAQUAfastreg II Colorimeters Vacuum Degasser Flowmeter are warranted to be free fromdefects in material and workmanship for a period of twelve (12) months from the date ofpurchase by the user or eighteen (18) months from date of shipment from Thermo Orionwhichever is earlier provided use is in accordance with the operating limitations andmaintenance procedures in the instruction manual and when not having been subjectedto accident alteration misuse or abuse
The warranty period for 960 Titrator PLUS 950 Fast QC Titrator Wine Master and 930 Ionalyzer pumps is three (3) months from date of purchase
Economy Line Electrodes Models 91-05 91-06 91-15 91-16 91-25 91-26 91-35 91-36 92-06 are warranted to be free from defects in material and workmanship for a period of three (3) months from date of purchase by customer or six (6) months from date ofshipment from Thermo Orion whichever is earlier Warranty also includes failure for anyreason (excluding breakage) except abuse provided the electrode is not used in solutionscontaining silver sulfide perchlorate or hydrofluoric acid or in solutions more than one (1)Molar in strong acid or base at temperatures above 50 ˚C
Ion Selective Electrodes ionplusreg Electrodes ROSStrade Electrodes Sure-Flowreg ElectrodesPerpHecTreg Electrodes AquaPro Professional Electrodes Standard Line pH Electrodes Tris pH Electrodes ORP Triode (Cat No 9180BN) pHuturetrade pH Probes (Cat No 616500) and pHuture MMStrade Quatrodetrade and Triode (Cat Nos 616600 and 617900) Model 97-08 DO Probe Series 100 Conventional Conductivity Cells temperature probes and compensators(except those models noted) are warranted to be free from defects in material andworkmanship for a period of twelve (12) months from the date of purchase by the customer or eighteen (18) months from date of shipment from Thermo Orion whichever is earlierexcept for abuse or breakage of electrodes 93 and 97 ionplus Series sensing modules arewarranted to give six (6) months of operation if placed in service before the date indicated onthe package except 93-07 and 97-07 Nitrate modules are warranted to give ninety (90) daysof operation if placed in service before the date indicated on the package
Thermo Orion pHuturetrade (Cat No 615700) and pHuture MMStrade Pentrodetrade (Cat No 617500)Quatrodetrade (Cat No 617800) and Triode (Cat No 615800) Low Maintenance Triodetrade
(Cat No 9107BN) ORP Low Maintenance Triode (Cat No 9179BN) and PerpHecT LowMaintenance Triode (Cat No 9207BN) Waterproof Triode (Cat No 9107WP 9107WL9109WL 9109WP) QuiKcheKtrade Meters Micro Electrodes are warranted to be free fromdefects in material and workmanship for a period of six (6) months from date of purchase bythe customer or twelve (12) months from date of shipment from Thermo Orion whichever isearlier when used in accordance with the operating limitations and maintenance procedurein the instruction manual and when not having been subjected to accident alteration misuseor abuse
AQUAfast IV colorimeters Series 100 DuraProbetrade Conductivity Cells and Series 800 DissolvedOxygen Probes are warranted to be free from defects in material and workmanship for a
WarrantyTable of Contents | 25
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
Thermo OrionCat No
095000
095001
095003
095004
093000
093001
093003
093004
096000
096002
96050A
96150A
96250A
SC0960
AS3050
AS3150
AS3250
ASB050
ASB150
ASB250
096S22
ASR050
ASR150
ASR250
0960S1
0960S2
9342BN
096010
096011
096014
096016
096017
For Fisher Cross Reference Please Click Here
International Customers Contact Your Favorite Thermo Orion Dealer
For VWR Canlab Cross Reference Please Click Here
Page No
9 12 24
9 12 24
9 12 24
9 12 24
10 12 24
10 12 24
10 12 24
10 12 24
7 12 24
7 12 24
8 24
8 24
8 24
8 24
8 24
8 24
8 24
8
8
8
8
8
8
8
24
24
17 24
13 24
13 24
13
13
13
Thermo OrionCat No
096019
096021
096025
096035
096038
096050
0960AE
0960KF
0960PC
096G12
096SRT
096ZXA
0GLP05
0GLP07
0GLP08
0GLP10
0GLP30
0GLP31
0GLP35
960DPU
950DPU
950EPN
DTPL20
DTPL21
DTPL22
096039
096045
650700
652012
654201
654202
654203
Cross Reference
Page No
13
13
13
13
13
13 14
14
13
14
14
14
14
14
14
14
14
13 24
13 24
14
14
14
14
14
14
14
13
13
17
15
17
17
17
Table of Contents | 26
Customer Service and Support 8002251480 - 9782326015 (fax)
Thermo OrionCat No
654204
654205
319040001
319040000
319035001
319035002
319045001
319045000
319050001
319050000
319035010
319035012
319035014
319040010
319040012
319040014
319045012
319050014
319018201
225205-001
225206-001
225207-001
225208-001
225209-001
225302-001
225303-001
225304-001
225305-001
225306-001
319016000
319016400
319035008
Page No
17
17
21 23 24
21 23 24
21 23 24
21 23 24
19 23 24
19 23 24
18 23 24
18 23 24
21
21
21
21
21
21
19
18
22 24
22
22
22
22
22
22
22
22
22
22
19
19
21
Thermo OrionCat No
319035016
319035018
319035022
319035024
319035026
319035028
319035029
319035032
319035038
319035039
319035040
319035043
319035045
319040008
319050012
319050018
0KFDPU
319050028
319050030
319015012
319016800
319017200
319045010
319040022
319035034
319035030
319035020
319050016
319050020
319050024
319050026
Page No
21
21
21
21
21
21
21
21
22
22
22
22
22
21
18
18
22
18
18 19
18
19
19
19
21
21
21
21
18
18
18
18
CanlabA COMPANY
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc
228684-001 rev C
Thermo Orion Customer Support Toll Free 800-225-1480 wwwthermoorioncom Dom e-mail domcs1thermoorioncomIntrsquol e-mail intcs1thermoorioncom
Thermo Orion 500 Cummings CenterBeverly MA 01915-6199 USATel 978-232-6000Dom Fax 978-232-6015Intrsquol Fax 978-232-6031
Thermo Orion Europe 12-16 Sedgeway Business ParkWitchford CambridgeshireEngland CB6 2HYTel 44-1353-666111Fax 44-1353-666001
Thermo Orion Far East Room 904 Federal Building369 Lockhart RoadWanchai Hong KongTel 852-2836-0981Fax 852-2834-5160
A Thermo Electron businessFormerly Orion Research Inc