sensit technologies industrial safety product guide
DESCRIPTION
SENSIT® gas monitors alert personnel of hazardous gases in their working environment. SENSIT® gas leak detectors are used during gas pipe system purging, service and maintenance.TRANSCRIPT
Innovative Detection SolutionsInnovative Detection Solutions
www.gasleaksensors.comwww.gasleaksensors.com
PRODUCT GUIDE
INDUSTRIAL hEALTh & SAFETY
Gas Leak Detectors
Gas Monitors
Calibration Stations
Data Management
The Company:SENSIT Technologies is an ISO 9001:2008 compliant, family-owned business located in Valparaiso, Indiana. Since 1980, we have manufactured gas leak detection products that help protect life and property.
Today, as a result of continuous innovation and commitment to customer satisfaction, the company has grown to become a global supplier to several markets:
•Energy:NaturalandPropaneGasIndustries •EmergencyResponse:FireServices •Industrial:Health,SafetyandMaintenance •Municipal:WaterworksandInfrastructure •ServiceContractors:HVACandPlumbing
The Products:SENSIT gas detection products are best known for quickly and easily locating gas leaks and accurate measurement of toxic gases. Durability and low cost of ownership have added to our product popularity. SENSIT instruments can be found in many forms:
•GasLeakDetection •PersonalGasMonitors •InfrastructureDetection
OurinstrumentsmeetapprovalagencystandardsfromUL,ATEX,andCSA.Virtuallyallofourinstrumentscanbe linked to compliance reportingwith theuseofourSmart-Cal calibrationanddatamanagementsystem.Itisthefinallinkforanytotalinstrumentprogram.
The People:The most important asset we have to offer is our incredible people. Our dedicated team of gas detection experts have centuries of combined experience in product development, production, sales and service. Completecustomersatisfactionisournumberoneobjective:
•Providetheexactproducttomeetyourrequirements •Exceedyourexpectationsforservice •Offerthelowestcostofownershipoverthelifeoftheproduct
The Future:SENSIT Technologies is committed to bringing new and innovative detection products to the global marketplace.
SENSIT Technologies851 Transport DriveValparaiso, IN 46383-8432
Phone:8884736748 2194652700
Fax: 2194652701Email: [email protected]: www.gasleaksensors.com
INDUSTRIAL hEALTh & SAFETY
PRODUCT GUIDE
SENSIT® GOLD Multi-Function Gas Detector ............................4
SENSIT® GOLD 100 Multi-Function Gas Detector ....................5
SENSIT® hXG-3 / hXG-3P Gas Leak Detector ....................6
SENSIT® hXG-2d Gas Leak Detector .....................................7
SENSIT® CO Carbon Monoxide Analyzer .................................8
TRAK-IT® IIIa Combustible Gas Indicator ..................................9
SENSIT® P400 Multi-Gas Personal Monitor ............................10
SCAL-400 Calibration Station for SENSIT® P400 .......................11
SENSIT® P100 Single-Gas Personal Monitor ............................12
SCAL-100 Calibration Station for SENSIT® P100 .........................13
SMART-CALTM Calibration Station ............................................14
SCAL-D / SCAL-N Data Management Software ......................15
LUERPROBECONNECTOR
WATER/DIRTFILTER
LEL/PPMSENSOR
INFRAREDCOMMUNICATIONS
BACKLITLCDDISPLAY
ALARMLEDs
OPERATIONBUTTONS
TICKADJUST
FLEXIBLEGOOSENECK
BATTERYCOMPARTMENT
Patented
1. Press Power2. Wait 45 Seconds for Automatic Zeroing3. Begin to Use
TO OPERATE:
SENSOR SPECIFICATIONSTYPE RESOLUTION RANGE ACCURACYLEAK(CSA) N/A 50-50,000ppm N/ALEAK(UL) N/A 10-50,000ppm N/APPM*(CSA) 1or10ppm 0-2,000ppm ±10%PPM*(UL) 1or10ppm 0-2,000ppm ±10%LEL 0.1%upto2.0% 0-100%LEL ±10%O2 0.1% 0-25% ±0.2%or10%**CO 1ppm 0-2000ppm ±5ppmor5%**H2S 1ppm 0-100ppm ±2ppmor5%**HCN 1ppm 0-30ppm ±1ppmor2.5%***PPMOptional **Whicheverisgreater
PRODUCT SPECIFICATIONSSize: 11.5”x3”x2.32”(29.2x7.6x6.9cm)Weight: 1.2lb.(0.5kg)OperationalTemp: 0to120F(-17.78to48.9°C)BatteryLife: Alkaline:Approximately12hrs.Continuous
Designed to help you find the source of combustible gases fast!SENSIT® GOLD
Displays Up To4 Gases Simultaneously•LEL(PPMOptional)•Oxygen•CarbonMonoxide•HydrogenSulfide•HydrogenCyanide(Optional)
Standard Features•IntrinsicallySafeDesign(Certified)•LowestCost,LongLifeSensors•InternalPump•Water/DustFilter•PushButtonOperation•FieldCalibration•Date/TimeDisplay•CalibrationAlert•OperationMemory•CalibrationMemory•InfraredDownload•Audible/VisualAlarms•BrightLCDDisplay•ProgrammableAutoShutOff
Applications•CombustibleGasLeakDetection•GasLeakSurvey•UndergroundLeakPinpointing•CarbonMonoxideInvestigations•ConfinedSpaceMonitoring•CombustibleGasMeasurements•PipelinePurging•Method21EmissionsTesting
Partial List of Gases Sensed•Butane •CarbonMonoxide•Gasoline •HydrogenSulfide•Methane •NaturalGas•Oxygen •Propane
STANDARD KIT•HardCarryingCase•3“C”Batteries•ExtraSensorCap
•WristStrap•InstructionManual
4
LUERPROBECONNECTOR
WATER/DIRTFILTER
LEL/PPMSENSOR
INFRAREDCOMMUNICATIONS
BACKLITLCDDISPLAY
ALARMLEDs
OPERATIONBUTTONS
TICKADJUST
FLEXIBLEGOOSENECK
BATTERYCOMPARTMENT
Patented
1. Press Power2. Wait 45 Seconds for Automatic Zeroing3. Begin to Use
TO OPERATE:
SENSOR SPECIFICATIONSTYPE RESOLUTION RANGE ACCURACYLEAK N/A 10-50,000ppm N/APPM* 1or10ppm 0-2,000ppm N/ALEL 0.1% 0-100%LEL ±10%%NATGAS 0.1% 5-100%GAS ±5%O2 0.1% 0-25% ±0.2%or10%**CO 1ppm 0-2000ppm ±5ppmor5%**H2S 1ppm 0-100ppm ±2ppmor5%**HCN 1ppm 0-30ppm ±1ppmor2.5%**
*PPMOptional **Whicheverisgreater
PRODUCT SPECIFICATIONSSize: 11.5”x3”x2.32”(29.2x7.6x6.9cm)Weight: 1.2lb.(0.5kg)OperationalTemp: 0to120F(-17.78to48.9°C)BatteryLife: Alkaline:Approximately12hrs.Continuous
A multi-function gas detector ideal for inert and purging applications.SENSIT® GOLD 100
Displays Up To4 Gases Simultaneously•LELand%Volume(PPMOptional)•Oxygen•CarbonMonoxide•HydrogenSulfide•HydrogenCyanide(Optional)
Selectable Gas Type•Methane(NaturalGas)•Propane
Standard Features•IntrinsicallySafeDesign(Certified)•LowestCost,LongLifeSensors•InternalPump•Water/DustFilter•PushButtonOperation•FieldCalibration•Date/TimeDisplay•CalibrationAlert•OperationMemory•CalibrationMemory•InfraredDownload•Audible/VisualAlarms•BrightGraphicDisplay•ProgrammableAutoShutOff
Applications•CombustibleGasLeakDetection•GasLeakSurvey•UndergroundLeakPinpointing•CarbonMonoxideInvestigations•ConfinedSpaceMonitoring•CombustibleGasMeasurements•PipelinePurging(NFPA54Compliant)•Method21EmissionsTesting•InertGasOperations•ReplacementforBiosystemsCannonball3
Partial List of Gases Sensed•Butane •CarbonMonoxide•Gasoline •HydrogenSulfide•Methane •NaturalGas•Oxygen •Propane
STANDARD KIT•HardCarryingCase•3“C”Batteries•ExtraSensorCap
•WristStrap•InstructionManual
5
Patented
SENSOR
BACKLITLCDDISPLAY
WARNINGLEDS
OPERATIONBUTTONS
TICKCONTROL
FLEXIBLEGOOSENECK
BATTERYCOMPARTMENT
1. Press Power2. Wait 45 Seconds for Automatic Zeroing3. Begin to Use
TO OPERATE:
PRODUCT SPECIFICATIONSSize: 11.5”x3”x2.2”(29.21x7.62x5.89cm)Weight: 1.2lb.(0.54kg)OperationalTemp: -4to122F(-20to50°C)BatteryLife: Alkaline:Approximately25hrs.Continuous
SENSOR SPECIFICATIONSTYPE RESOLUTION RANGE ACCURACYPPM* 1or10ppm 0-50,000ppm ±10%LEL 0.1% 0-100%LEL ±10%
*PPMOptional
Displays LEL and PPM readings simultaneously for accurate leak detection and analysis.SENSIT® HXG-3/3P
STANDARD KIT•HardCarryingCase•3“C”Batteries
•WristStrap•InstructionManual
HXG-3 Standard Features•IntrinsicallySafeDesign(Certified)•DisplaysLELandPPM•Audible/VisualAlarms•InfraredDownloading•Long-life,Low-CostSensor•SimpleCalibration
HXG-3P Standard Features•IntrinsicallySafeDesign(Certified)•InternalPump•Water/DustFilter•DisplaysLELandPPM•InfraredDownloading•Long-life,Low-CostSensor•SimpleCalibration
Applications•LocateSmallGasLeaks•AreaMonitoring•GasLeakSurveying•GasLinePurging•Arson/AccelerantDetection
Partial List of Gases Sensed•Acetone•Alcohol•Ammonia•Butane•Gasoline•Halon•Hydrogen
•IndustrialSolvents•JetFuel-2610•EthyleneOxide-2610•LacquerThinner•Methane•NaturalGas•Propane•Refrigerants
6
PRODUCT SPECIFICATIONSSize: 3.5”x10”x1.6”(8.9x25x4cm)Weight: 1.2lb.(0.544kg)OperationalTemp: -4to104°F(-20to40°C)BatteryLife: Alkaline:Approximately50hrs.Continuous
SENSOR SPECIFICATIONSTYPE RESOLUTION RANGE ACCURACYPPM* 10ppm 0-990ppm ±10%LEL 0.1% 0-100%LEL ±10%
*PPMOptional
Gas leak detector with digital display for accurate measurement of gases.SENSIT® HXG-2d
STANDARD KIT•CarryingPouch•3“C”Batteries•T10AllenWrench•InstructionManual
Standard Features•IntrinsicallySafeDesign•Push-ButtonOperation•FieldCalibration•BacklitDisplay•AdjustableAlarms•Long-life,Low-CostSensor
Applications•LocateSmallGasLeaks•AreaMonitoring•GasLeakSurveying•GasLinePurging•ChemicalDetection•Arson/AccelerantDetection
Partial List of Gases Sensed•Acetone•Alcohol•Ammonia•Butane•EthyleneOxide•Gasoline•Halon•Hydrogen•IndustrialSolvents•JetFuel•LacquerThinner•Methane•NaturalGas•Propane•Refrigerants
The SENSIT® HXG-2dcannotbeusedtocheckforcarbonmonoxide(CO)leakage.
PatentPending
SENSOR
ALARMLED
GRAPHICDISPLAY
OPERATIONBUTTONS
ELECTRONICTICKCONTROL
FLEXIBLEGOOSENECK
BATTERYCOMPARTMENT
1. Press Power2. Wait 45 Seconds for Automatic Zeroing3. Begin to Use
TO OPERATE:
7
PRODUCT SPECIFICATIONSSize: 3”x10”x2.4”(7.6x25.4x6cm)Weight: 1.1pounds(0.5kg)OperationalTemp: -4to104°F(-20to40°C)BatteryLife: Alkaline:Approximately30hrs.Continuous
SENSOR SPECIFICATIONSTYPE RESOLUTION RANGE ACCURACY
CO 1ppm 0-2,000ppm ±5ppmor5%**
CO“AirFree”* 1ppm 0-5,000ppm ±5ppmor5%**
O2* 0.1% 0-25% ±0.2%or10%**
*OptionalConfiguration **Whicheverisgreater
Use SENSIT® CO for Carbon Monoxide testing in residential and commercial buildings.SENSIT® CO
Withitspowerfulrotarypump,hotairprobeandbrightLCDdisplay,theSENSIT® CO is perfect for testing ambient air and hot gas samples.
Infrared communication allows printing of test resultstoacompactprinter(accessory)orPCsimple and convenient.
Applications•COInvestigations•FlueGasTesting•EquipmentInspection&Testing
Standard Features•InternalPump•FlueProbewithWaterTrap•Audible/VisualAlarms•BacklitLCDDisplay•AutomaticZeroing•FieldCalibration•CalibrationAlerts•MemoryStorage•InfraredDownload•HardCarryingCase
Optional Features
Oxygen Sensing:DisplayOxygenandCOSimultaneously
Air-FreeCOReading:AutomaticallyCalculatesCOBasedonAir-FreeCalculation
STANDARD KIT•HardCarryingCase•3“C”Batteries•FlueProbe•5FootFlexibleTubing •ParticleFilter•WristStrap•InstructionManual
WATER/DIRTFILTER
HOTAIRPROBE
INFRAREDCOMMUNICATIONS
BACKLITLCDDISPLAY
ALARMLEDs
OPERATIONBUTTONS
BATTERYCOMPARTMENT
Patented
1. Press Power2. Wait 45 Seconds for Automatic Zeroing3. Begin to Use
TO OPERATE:
8
PRODUCT SPECIFICATIONSSize: 6.5”x4”x4.25”(16.5x10.2x10.8cm)Weight: 2.8lb.(1.27kg)OperationalTemp: -4to104F(-20to40°C)BatteryLife: Alkaline:Approximately40hrs.Continuous
SENSOR SPECIFICATIONSTYPE RESOLUTION RANGE ACCURACYPPM* 5ppm 0-2,000ppm ±10%LEL 0.1%upto2% 0-100%LEL ±10%%NATGAS 0.1% 5.0-100%GAS ±5%O2 0.1% 0-25% ±0.2%or10%**CO 1ppm 0-2000ppm ±5ppmor5%**H2S 1ppm 0-100ppm ±2ppmor5%**HCN 1ppm 0-30ppm ±2ppmor5%**
*PPMOptional **Whicheverisgreater
Combustible Gas Indicator designed for extreme working conditions.TRAK-It® IIIa
Displays Up To4 Gases Simultaneously•LEL(%VolumeandPPMOptional)•Oxygen•CarbonMonoxide•HydrogenSulfide
Standard Features•IntrinsicallySafeDesign(Certified)•2-SpeedInternalPump•IdentifiesNaturalGasvsPropaneGas•LowestCost,LongLifeSensors•LEDWarningLights•LargeBrightGraphicDisplay•LoudAudibleAlarm•Optional1600EventAutoLog•ExceptionalWaterProtection•LongBatteryLife•CostEffectiveAsAnAreaMonitor•InfraredDownloading•Built-inNaturalGasandPropaneGasCalibration•StainlessSteelHousing
Applications•GasLinePurge•UndergroundLeakPinpointing•GasLeakInvestigations•CarbonMonoxideInvestigations•ConfinedSpaceMonitoring•CombustibleGasMeasurements
Partial List of Gases Sensed•Butane •CarbonMonoxide•Gasoline •HydrogenSulfide•Methane •NaturalGas•Oxygen •Propane
STANDARD KIT•PaddedCarryingPouch•4“C”Batteries•NeckStrap•ExternalWater/DirtFilter •InstructionManual•ChoiceofBarHoleProbeorConfinedSpaceProbe
PatentPending
SPEAKER
NECKSTRAP
OPERATIONALBUTTONS
PADDEDCARRYINGPOUCH GRAPHICDISPLAY
IRWINDOW
STATUS/ALARMLEDs
PROBEASSEMBLY
1. Press Power2. Wait 45 Seconds for Automatic Zeroing3. Begin to Use
TO OPERATE:
9
PRODUCT SPECIFICATIONSSize: 5.2”x3.2”x1.7”(13.2x8.1x4.0cm)Weight: 12oz.(340g)OperationalTemp: -4to122F(-20to50°C)Humidity: 10-90%RH(Non-condensing)PowerSource: 4“AA”AlkalineorNiMHRechargerPackBatteryLife: 24Hr.Alkalineor15Hr.NiMHTypicalResponseTime: Initial<2Sec T90<10Sec(LEL)Sound: 98db @ 15cm
SENSOR SPECIFICATIONS RESPONSETYPE RESOLUTION RANGE ACCURACY T90 TIMESLEL 0.1% 0-100 ±10% <10SecO2 0.1% 25% ±2%or10%** <10SecCO 1ppm 0-999* ±5ppmor10%** <10SecH2S 1ppm 0-100 ±2ppmor10%** <20SecHCN 0.1ppm 0-30 ±1ppmor10%** <20Sec NO2 1ppm 0-250 ±2ppmor10%** <20SecPH3 0.1ppm 0-10 ±1ppmor10%** <20Sec SO2 0.1ppm 0-20 ±1ppmor10%** <20SecETO 0.1ppm 0-10 ±1ppmor10%** <20Sec
*COExtendedRangeAvailable0ppm-1999ppm. **Whicheverisgreater
Multi-gas personal monitor designed to warn the user of hazardous gases in their working environment.SENSIT® P400
P400 can be configured with 1 to 5 sensors.
Standard Features•ExtremelyRugged,IntrinsicallySafeDesign•LowestCost,LongLifeSensors•AudibleAlarm-3Tone•VisualAlarm-360°View•VibrationAlarm•STELandTWAAlarms•Compliance/StatusIndicator•DataLogging•EasyFieldCalibration•EasyCleanDustPre-Filter•Easy-AccessReusableDustFilter•Alkalineand/orNiMHBattery•Limited2-YearWarranty(IncludingSensors)•ExtendedWarrantyAvailable
P400 Optional FeatureImmediateDetectionSystem(IDS)Early warning to changes in gas concentrations
Available Sensors•Oxygen(O2)•CarbonMonoxide(CO)•HydrogenSulfide(H2S)•HydrogenCyanide(HCN)•NitrogenDioxide(NO2)•SulfurDioxide(SO2)•CombustibleGases
COMPLIANCE/
STATUSINDICATOR
ALARMLEDs
SENSORAREA
SENSORFILTER
FUNCTIONBUTTONS
SOUNDER
GRAPHICDISPLAYw/BACKLIGHT
BELTCLIP(ONBACK)
Patented
TOOPERATE:1. PressPower2. Wait30SecondsforAutomaticZeroing3. Begin to Use
STANDARD KIT•BeltClip•InstructionManual•CalibrationAdapter•DustPre-Filter•AlkalineBatteries
KIT OPTIONS• Confined-SpaceEntryKit• CalibrationStation• CalibrationKit• RechargerBatteryPack• RechargerStation
10
PRODUCT SPECIFICATIONSSize: 24”x7”x3”(61cmx17.8cmx7.6cm)Weight: 5.75lb.(2.6kg)OperationalTemp: 40–122F(5to50°C)Max.InletPressure: 20PSIPower: 100-240VAC
SCAL-400
All calibration data, time, date, andsensor performance data is stored in the calibrator for download to your computer. Data management software allows automatic uploading from calibrator, creates compliance reports and alerts selected personnel of overdue or failed calibrations.
Standard Features:•Touchscreenoperation•Testupto5instrumentssimultaneously•Autooperationwheninstrumentisinstalled•Indicationofpassorfail•RJ45intranetconnection•CompatiblewithWindows7andWindowsXPNetwork
SCAL-400Reporting Features:•InstrumentTestPastDue•InstrumentFailureAlerts•MonthlyComplianceReport•SensorPerformanceData•OptionalNetworkingSystem•Compatiblewith:SCal-DTM(Desktop)SCal-NTM(Network)DataManagementSoftware
SOFTWARE REQUIREMENTS30MBHardDriveSpaceWindows® XP,Vista,7OperatingSystemMicrosoft® Outlook(Preferred.NotRequired)Microsoft®Excel(Preferred.NotRequired)Microsoft®SQLServer(SQLServerExpressIncluded)
Automatically charges, bump tests and calibrates up to five SENSIT® P400 Gas Monitors simultaneously.
POWERCONNECTION USBRJ45SERIAL
TOUCHSCREEN STATUSINDICATORS
GASCONNECTIONS
CHARGINGPINS
COMMUNICATIONPIN
GASOUTLET
SCAL-400 is designed for use withSENSIT® P400 Gas Monitors
•CH4 •CO •O2 •H2S
•HCN •NO2 •SO2 •CombustibleGases
11
PRODUCT SPECIFICATIONSSize: 3.81”x2.31”x0.8”(9.67x5.87x2cm)Weight: 3.6oz.(105g)OperationalTemp: -4to104F(-20to40°C)Humidity: 15-90%RH(Non-condensing)PowerSource: 3.6VLithiumBatteryBatteryLife: 2+Years
SENSOR SPECIFICATIONSTYPE RESOLUTION RANGEO2 0.1% 25%
CO* 1ppm 0-999*
H2S 1ppm 0-100
HCN 0.1ppm 0-30
NO2 0.1ppm 0-20
SO2 0.1ppm 0-20
Single gas personal monitor designed to warn the user of hazardous gases in their working environment.SENSIT® P100
Standard Features•IntrinsicallySafeDesign(Certified)•OneButtonOperation•AudibleAlarm•VisualAlarm•VibrationAlarm•STELandTWAAlarms•AlarmEventMemory•EasyFieldCalibration•2-YearOperation•RefurbishProgramAvailableAfter2-yearsOfOperation•Limited2-YearWarranty(IncludingSensor)•ExtendedWarrantyAvailable•ForusewithSCAL-100TestStations
Available Sensors•HydrogenSulfide(H2S)•HydrogenCyanide(HCN)•Oxygen(O2)•CarbonMonoxide(CO)•NitrogenDioxide(NO2)•SulfurDioxide(SO2)
STANDARD KIT•BeltClip•InstructionManual
ALARMLEDs
SENSOR
SOUNDER
ON/OFF
GRAPHICDISPLAY
ZERO/CALIBRATE
BELTCLIP(ONBACK)
Patented
TO OPERATE:1. Press Power2. Wait 30 Seconds for Automatic Zeroing3. Begin to Use
*CO Extended Display Option:
DetectionRange:0ppm-.2%Volume(2000ppmequivalent)
Resolution:1ppm for 0 – 999ppm01%Volumefor1000ppm–2000ppm
12
PRODUCT SPECIFICATIONSSize: 6”x6”x1.75”(15.24cmx15.24cmx4.5cm)Weight: 2lb.(0.9kg)OperationalTemp: 40–120F(5to50°C)Max.InletPressure: 20PSIPower: 100-240VAC50/60Hz0.2Ainputwith2VDC0.5Aoutput
SCAL-100All calibrationdata; time, date, sensor andpump performance data is stored in the calibrator for download to your computer. Data management software allows automatic uploading from calibrator, creates compliance reports and alerts selected personnel of overdue or failed calibrations.
Design to Test/CalibrateSENSIT® P100 Monitors•O2•CO•H2S•HCN •NO2•SO2
Standard Features:•Indicatespropergaspressure•Automaticoperation when instrument is installed•Indicationofpassorfail•RJ45intranetconnection•Wallordeskmount•CompatiblewithWindows7andWindowsXPNetwork
SMART-CALTM
Reporting Features:•InstrumentTestPastDue•InstrumentFailureAlerts•MonthlyComplianceReport•SensorPerformanceData•OptionalNetworkingSystem•Compatiblewith:SCal-DTM(Desktop)SCal-NTM(Network)DataManagementSoftware
Available Test Gases*•Oxygen-O2•CarbonMonoxide-CO•HydogenSulfide-H2S•HydrogenCyanide-HCN•NitrogenDioxide-NO2•SulfureDioxide-SO2
*ContactSensitTechnologiesformoreinfo.
SOFTWARE REQUIREMENTS30MBHardDriveSpaceWindows® XPorLaterOperatingSystemMicrosoft® OutlookMicrosoftExcel
LANCONNECTION POWERCONNECTION
IRCOM
GASOUTLET
MOUNTINGPLATE
GASINLET
RETAININGCLIP
Calibrates SENSIT® P100 Single Gas Monitors, stores data and manages instrument testing compliance.
For use with Black P100 Models Only.
13
PRODUCT SPECIFICATIONSSize: 10.75”x6.75”x4.5”(27.3cmx17.1cmx11.4cm)Weight: 2.5lb.(1.13kg)OperationalTemp: 32to120F(0to48.9°C)Max.InletPressure: 20PSIPower: 100-240VACInputwith12VDCOutput
Calibrates SENSIT® and Trak-It® instruments, stores data and manages instrument testing compliance.SMART-CALTM
All calibrationdata; time, date, sensor andpump performance data is stored in the calibrator for download to your computer. Data management software allows automatic uploading from calibrator, creates compliance reports and alerts selected personnel of overdue or failed calibrations.
SMART-CALTM
Designed for use with:•SENSIT®CO•SENSIT®GOLD•SENSIT®GOLDCGI•SENSIT®GOLDG2•SENSIT®HCN•SENSIT®HXG-3•SENSIT®HXG-3P•SENSIT®PMD•Trak-It®IIICGI•Trak-It® IIIa
SMART-CALTM
Standard Features:•PushButtonOperation•BacklitLCDDisplay•LineofSightIRCommunication•Date/TimeDisplay•AutomaticDateAdjustment•AutomaticUpload•CalibrationMemory•BottlePressureMonitoring•CompatiblewithWindows7andWindowsXPNetwork
SMART-CALTM
Reporting Features:•InstrumentTestPastDue•InstrumentFailureAlerts•MonthlyComplianceReport•SensorPerformanceData•OptionalNetworkingSystem•Compatiblewith:SCal-DTM(Desktop)SCal-NTM(Network)DataManagementSoftware
Available Test Gases*•PPM(Methane)•LEL(Methane)•LEL(Propane)•%Volume•CarbonMonoxide-CO•HydrogenCyanide-HCN•HydogenSulfide-H2S•Oxygen-O2
*ContactSensitTechnologiesformoreinfo.
SOFTWARE REQUIREMENTS30MBHardDriveSpaceWindows® XPorLaterOperatingSystemMicrosoft® OutlookMicrosoftExcel
9-PINSERIALINTERFACE
FRESHAIRINPUTS
COLORCODEDGASCONNECTIONS
1/4TURNLUERCONNECTION
12VDCINPUTINCLUDINGWALLTRANFORMER
INSTRUMENTCRADLES REFERENCEINSTRUCTIONSOPERATIONBUTTONSBACKLITLCDDISPLAY
14
PRODUCT SPECIFICATIONSSCAL-DorSCAL-NSoftwareCD(UserGuideIncludedonDisc)PrintedInstallationGuide
SCAL-D / SCAL-NSCal is the Data Management Software used to download data from Calibration Stations.
Various reports and alerts can be viewed, printed, emailed or stored as an Excel spreadsheet. When configured it willautomatically alert operators and supervisors of important data depending on their preference. SCal provides an easy to useinterface and content sensitive help with FAQ’sforquickresponse.
SCal-D is the Desktop version of the software. This single-user software application comes standardwithCalibrationStations.
SCal-N is the Network version of the software. SCal-N is sold separately with amulti-year license.Use SCal-N to downloaddata from remotely located CalibrationStation(s).DataisstoredinSQLServer.
SCal-N is divided into two categories:
Admin Application:
The Admin application is the host for theautomaticdownloadingofremoteCalibrationStations that have the proper communication hardware installed. This program is SQLServerbased.Youmust installanduseonlyonecopyofSCal-NasAdmin.
User Application:
The User Application allows viewing ofselected data stored in the Server databasefrom any computer that has access or privileges.Anauthorizedloginandpasswordto theSQLServer is required foreachUserapplication installed.
*ContactSensitTechnologiesformoreinfo.SOFTWARE REQUIREMENTS30MBHardDriveSpaceWindows® XPorLaterOperatingSystemMicrosoft® OutlookMicrosoftExcel
Data Management Software for use with SMART-CALTM & SCal-100 Calibration Stations
HARDWARE REQUIREMENTS
SMART-CALTM
Design for use with:•SENSIT®CO•SENSIT®GOLD•SENSIT®GOLDCGI•SENSIT®GOLDG2•SENSIT®HCN•SENSIT®HXG-3•SENSIT®HXG-3P•SENSIT®PMD•Trak-It®IIICGI•Trak-It® IIIa
SCAL-100Design for use with:•SENSIT®P100(BlackHousing)
15
Why Choose
SENSIT
Distributed by:
©2015SENSITTECHNOLOGIES
MADE IN USA
851 Transport DriveValparaiso, IN 46383-8432
Phone:8884SENSIT 8884736748 2194652700
Fax: 2194652701 www.gasleaksensors.com
SENSIT Technologies is in compliance with ISO 9001:2008
• User-Friendly, Durable Instruments• Lowest Cost of Ownership• Unmatched Service and Support• Made in USA
SENSIT Instruments Detect One Or More Of The Following Gases:
•NaturalGas-Blend•CarbonMonoxide-CO•HydrogenCyanide-HCN•HydrogenSulfide-H2S•Methane-CH4•NitrogenDioxide-NO2•Oxygen-O2•Propane-C3H8•SulfurDioxide-SO2•VolatileOrganicCompounds-VOCs
Calltoday,tolearnmoreaboutour30DayTry-ItOfferforqualifiedusers.
Toll-Free:888473.6748Sign-up Online at:
www.gasleaksensors.com/try.html
Try-ItSEE A PRODUCT THAT INTERESTS YOU?
30 Days FREE
View Our Entire Product Line:www.gasleaksensors.com