sepev @passiexpo 2013
DESCRIPTION
Zero Energy and Passive House Association of TURKEY Tugba Salman Gurcan Certified Passive House Designer President of BoardTRANSCRIPT
![Page 1: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/1.jpg)
![Page 2: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/2.jpg)
Tugba Salman Gurcan
Certified Passive House Designer
President of Board
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 3: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/3.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
SEPEV – Zero Energy and Passive House Association of TURKEY
- a young organization- founded in 2012 December- has 32 members by day
- Promotion of the Passive House Standard and Zero-Energy Buildings in Turkey.
- Platform for architects, engineers and contractors, students, for all who concerned with build environment.
![Page 4: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/4.jpg)
Passivhaus =
FUTURE
+ cost optimized-----------------------
+ healthy
energy efficiency
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 5: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/5.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
Obstacles of Passive House in Turkey
![Page 6: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/6.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
•„passive“ doesn`t make sense in Turkish and doesn‘t sound very sexy • Private idea – no legal standard (confusion, …)• No abundant component market (lack of rivalry, aligned) • Experts needed (costs,…)• Missing quality of craftsmanship (costs, …)• All this certifications (fears, costs, …)• PHPP (no interest, fee, …)• Limited design freedom and new technologies (fears, …)• Thermal bridge free construction (costs, …)• Optimized building services (costs, …)
![Page 7: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/7.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
The greater the obstacle, the more glory in overcoming it.
Moliere
![Page 8: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/8.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
GAZIANTEP - The town of Baklava and Kebap
is calling for Passive House
![Page 9: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/9.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
37°04'01"N and 37°23'00”E
Mediterranean climate with influences of continental climate during winter with very hot summers and cold, wet occasionally snowy winters
GAZIANTEP
![Page 10: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/10.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
While designing a building in Gaziantep with Passive House measures, special care had to be taken to the summer protection and to the avoidance of overheating.
Questioning ‘how Passive House should be in hot/dry climates?’
![Page 11: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/11.jpg)
Human Resources Centre of Gaziantep Metropolitan Municipality
1st Passive House Building of Turkey
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 12: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/12.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
In 2010….
The Mayor of Gaziantep was convinced to build a prototype Passive House Building
The Human Resources Centre
- with 315m2 treated floor area - a training center for the employment of the architectural and construction professionals in Gaziantep
![Page 13: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/13.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
German Experience comes to Turkey
since 1999 to 2013More than 350 Passive House buildings were designed by r-m-p architects all over Europe
![Page 14: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/14.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 15: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/15.jpg)
Zero Energy and Passive House Association - TURKEY
U-value (wall) : 0.085 W/m2K
Highly Insulated Building Fabric
PASS
IVE
HO
USE
U-value (Ground): 0,105 W/m2K
U-value : 0.112 W/m2K
![Page 16: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/16.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
Triple GlazedPHI certified Aluminium and PVC window system
![Page 17: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/17.jpg)
- a ground-air heat exchanger system (earth tubes) for pre-tempering ventilation air
- the system is linked up with a high performance mechanical ventilation unit with heat recovery (MVHR) – (%92 efficiency rate) to offer a full ventilation solution
Heat recovery for energy efficiency and comfort
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
GEA Isisan
Rehau EcoAir
![Page 18: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/18.jpg)
Water Source Heat Pump
South Façade Solar shading
Aluminum Triple Glazing
PV Array
Green Roof
Grey water and rain water collection
ECO Friendly Interior Materials
Zero Energy and Passive House Association - TURKEY
PASS
IVE
HO
USE
![Page 19: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/19.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
Energy Performance of the building:
PHPP model
![Page 20: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/20.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
Certified Passivhaus
LEED Platinum
Candidate for
![Page 21: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/21.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 22: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/22.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
The construction started...
2012 Summer
![Page 23: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/23.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 24: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/24.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 25: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/25.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 26: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/26.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 27: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/27.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 28: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/28.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
Achieving AIRTIGHTNESS….
Quality of workmanship is even more
important than careful planning!!!
![Page 29: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/29.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 30: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/30.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 31: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/31.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 32: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/32.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 33: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/33.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
![Page 34: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/34.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
DIALux Day-lighting Analysis
Cases with and without tress & without solar shading:
Figure 1 both with trees and solar shading
Figure 2 solar shading only
Figure 3 trees only
![Page 35: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/35.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
Final cost: 1,200 € / m2
application was done in Oct, 2013waiting to be certified by PHI.....
![Page 36: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/36.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
Next challenge of Passive Housein Gaziantep
1st Energy efficient renovation
- 283m2 (total floor area) - old building from 1970s
- project is founded by UNDP – Ministry of Development
![Page 37: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/37.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
Very poor conditions and too many leakages on building fabric….
![Page 38: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/38.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
Blower Door Test (Pre-retrofit conditions) 28.09.2013
![Page 39: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/39.jpg)
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
New Passive House Projects on board
Office Building / Ankara
Single Family House / Ankara
University Building / Ankara
Office Building / Balikesir
![Page 40: SEPEV @PassiEXPO 2013](https://reader038.vdocument.in/reader038/viewer/2022110118/554a43e1b4c905293a8b527b/html5/thumbnails/40.jpg)
Tugba Salman Gurcan
PASS
IVE
HO
USE
Zero Energy and Passive House Association - TURKEY
Thank you