september 27, 20041 ultrasonic flowmeters m-flow series
TRANSCRIPT
![Page 1: September 27, 20041 Ultrasonic Flowmeters M-Flow Series](https://reader036.vdocument.in/reader036/viewer/2022083008/56649d145503460f949e94ef/html5/thumbnails/1.jpg)
September 27, 2004 1
Ultrasonic Flowmeters
M-Flow Series
![Page 2: September 27, 20041 Ultrasonic Flowmeters M-Flow Series](https://reader036.vdocument.in/reader036/viewer/2022083008/56649d145503460f949e94ef/html5/thumbnails/2.jpg)
September 27, 2004 2
Ultrasonic Flowmeter, M-Flow
Development Concepts:
1. Economical pricing
2. Easy installation
3. Plastic housing, IP65
4. Fast response
M-Flow
Performance
Single-path Multi-path/channel
LP
$6,000
$4,70
0
$3,00
0
$2,000
Accuracy3% 2% 1%
Universal use UFMs
FLC/FLD
FLV/FLW
FLH/FLW
(TIME DELTA-F)
(TIME DELTA-S)
(PORTAFLOW-X)
Objectives:To develop the clamp on type of ultrasonic flowmeter for middle range markets.
![Page 3: September 27, 20041 Ultrasonic Flowmeters M-Flow Series](https://reader036.vdocument.in/reader036/viewer/2022083008/56649d145503460f949e94ef/html5/thumbnails/3.jpg)
September 27, 2004 3
Features
1. Easy to useClamp-On, no trouble for piping work
2. Compact and light weightAdopting of LSI technology & plastic housing
3. Superior temperature effectSound velocity measurement system
4. Quick responseSystem response is 0.2 seconds
5. MultilingualEnglish, Japanese, French, German & Spanish
![Page 4: September 27, 20041 Ultrasonic Flowmeters M-Flow Series](https://reader036.vdocument.in/reader036/viewer/2022083008/56649d145503460f949e94ef/html5/thumbnails/4.jpg)
September 27, 2004 4
M-Flow Technical SpecificationsApplicable Pipe Ø Plastic pipe: 25~225mm (1~9 inches)
Metal pipe: 50~225mm (2~9inches)Pipe Material Plastics such as PVC, PVDF, PEEK, PP, etc. and Metals
Velocity Range 0 to 0.3~10m/s
Accuracy 2% of rate (more than 2m/s), 0.04m/s (less than 2m/s)
Response Time Dead time 0.2s or less & damping 0.1s
Fluid Temperature -20 to +100 C
Thermal Stability +140 C, 30minutes
Ambient Temperature -20 to +50 C for converter & -20 to +50 C for detector
Analog Output 4to 20mA, 1Point (Maximum Load Resistance 600Ω)
Digital Output Relay & transistor, each 1 point (Scaled Pulse, Alarm, etc.)Scaled pulse: 1pulse/day to 100pps for transistor output 1pulse/day to 1pps for relay output Communication RS-232C/RS-485
Display LCD with 2 lines of 16 characters and backlight
Keyboard 4 Keys 0f escape, down, shift and entry
Power Supply 20 to 30Vdc, 100 to 120Vac or 200 to 240Vac, 50/60Hz
Enclosure Plastic housing, IP65
![Page 5: September 27, 20041 Ultrasonic Flowmeters M-Flow Series](https://reader036.vdocument.in/reader036/viewer/2022083008/56649d145503460f949e94ef/html5/thumbnails/5.jpg)
September 27, 2004 5
Ultrasonic Flowmeter, M-Flow
Compact M-Flow:
Converter Detector
![Page 6: September 27, 20041 Ultrasonic Flowmeters M-Flow Series](https://reader036.vdocument.in/reader036/viewer/2022083008/56649d145503460f949e94ef/html5/thumbnails/6.jpg)
September 27, 2004 6
The End