series 3000 xpis - honeywellanalitik.com · the series 3000 xpis provides comprehensive monitoring...
TRANSCRIPT
Series 3000 XPIS
2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres
The Series 3000 XPIS provides comprehensive monitoring of toxic and Oxygen gas hazards in potentially explosive atmospheres, both in and out of doors. This low powered gas detector operates on an industry standard 2-wire 4-20mA loop, making it ideal for both new and retrofit applications. Users can configure the detector without the need of a ‘hot work permit’ by using the LCD and magnetic switches. Fault diagnostic software and programmable calibration due frequency simplifies maintenance procedures.
The intrinsically safe smart sensors are suppliedpre-configuredandcanbe‘hotswapped’withouthavingtoremovepowertothe detector, saving time and money during commissioning and routine servicing. A remote sensor mounting kit is available that allows the sensortobemountedupto50’(15m)fromthe transmitter, making it ideal for operation in areas that are difficult to access.
Series 3000 XPIS is supplied with all necessary accessories for easy installation. The detector can be mounted on a wall or support pole using the universal bracket provided. Electrical installation can be made using either conduit or cable with suitable mechanicalprotection.A¾”NPTentryandM20 adaptor are included as standard. A weatherproof cap is also included for use in the harshest outdoor conditions.
Reliable detection• Provenelectrochemicalsensing technology • UsesSurecell™electrochemicalcells, idealforhotandhumidenvironments• Longlifesensingelements (typical>2years)• Patented‘Reflex’sensingelement verificationdiagnostics
Reduced installation costs• Universalmountingbracketincluded suppliedasstandard• Flameprooftransmitterallowsfieldwiring toberunalongwithothernonIS instruments• Plug-insensorremoveswiring
Reduced commissioning costs• Sensorrecognitionsoftwareauto configurestransmitter• Non-intrusiveconfiguration• Plugandplayfactoryconfiguredsensors
Reduced maintenance costs• ISsensorconnectionpermitshotswap, reducingdowntime• Userprogrammablecalibration frequency• Integralfaultdiagnosticsoftware• Menu/icondrivencalibration procedure
Regulatory compliance• European(ATEX)• US(UL)• Canadian(c-UL)• International(IECEx)
Range of optional accessories • Remotesensormountingkit• Ductmountingkit(forH2,CO andH2Sonly)• Calibrationcuptoapplytestgas• Collectingcone(forH2andCOonly)
Typical applications• Explorationanddrillingplatform• Productionplatforms• Onshoreoilandgasterminals• Refineriesandchemicalplants• Powerplants• Wastewaterfacilities• Utilities
Series 3000 XPIS
"3.7 / mm0 .581
150.0mm / 5.9"
"1.3 / mm0 .0850
.0mm
124.0mm
52.0m
m15
15
M5 Screw
M4 Screw
Earth Ground
Installation
Dimensions
Mechanical Installation Options
Pipe Mounting Wall MountDuct Mount Remote Mounting
Series 3000 XPIS is designed for use in potentially explosive atmospheres. As such, installation should follow national guidelines using suitable mechanically protected cable and glands(M20or¾”NPT)orconduit(¾”NPT).Use 0.5mm2 (20AWG) to 2.0mm2 (~14AWG) cross sectional area cable as needed to ensure minimum operating voltage at the detector, depending on installed cable length. Various accessories are available for different applications.
Electrical Connections
Detector supply Vd
• Assumedtobe17Vdc
Maximum detector signal Im
• Assumedtobe22mA (overrange)
Cable resistance Rc • Subjecttocabletype
Load resistor of control panel RL
• Assumed33Ω(min) or250Ω(max)• Subjecttocontroller manufacturer
Controller supply voltage Vc
• Subjecttocontroller manufacturer• Assumednominalof 24Vdc
Wiring Schematics
Terminal Detector Controller Number Terminal Connection
1 + +VE 2 - Signal
Typical Maximum Installed Cable Lengths
The maximum cable length between a controller and detector is dependent upon:
• Theminimumguaranteedsupplyvoltagetothedetectorat the controller (VC).• Theminimumoperatingvoltageofthedetector(Vd)• Themaximumcurrentdrawofthedetector(Im)• Theinputimpedanceofthecontroller(RL)• Theresistanceofthecable(RC)
Using the example values opposite, the table below shows typical cable lengths.
Foraspecificapplication,thecablemanufacturer’sresistancedatafor a specific cable type must be used.
Acablelengthcalculationformulacanbefoundinthedetector’sproduct technical manual.
1
2
3
1
2
3
+VE
Controller Detector
-VE
Signal Signal
+VERc
Im
Vc
RL
Vd
1
2
1
2
+VE
Controller
Detector
-VE -VE
Signal
+VERc
Im
Vc
RL
Vd
Remote Mounting Arrangement
Maximum Cable Length km (m)
Cable Size Cable Cable distance km (m) Cable distance km (m) Resistance where the Input where the Input Rc Ω/km Impedance Impedance (Ω/m) RL = 33Ω RL = 250Ω0.5mm2(20AWG*) 36.8(59.2) 3.9(6.3) 0.9(1.0)1.0mm2(17AWG*) 19.5(31.4) 7.3(11.7) 1.7(2.7)1.5mm2(16AWG*) 12.7(20.4) 11.2(18.0) 2.7(4.3)2.0mm2(14AWG*) 10.1(16.3) 14.1(22.7) 3.4(5.5)
* Nearest equivalent
Series 3000 XPIS Detector
Use Ruggedandreliablegasdetectorfortheprotectionofpersonnelfromtoxicand Oxygengashazards.SuitableforuseinZone1or2hazardousareasand NorthAmericanClassIandIIDivision1or2areas.
Detectable Gases
Gas Selectable full Default range scale range
Oxygen 25.0%/Volonly 25%Vol
CarbonMonoxide 100to1,000ppm 300ppm
HydrogenSulphide 10to50ppm 15ppm
HydrogenSulphide 50to500ppm 100ppm
Chlorine 5to20ppm 5ppm
Ozone 0to0.4ppmonly 0.4ppm
SulphurDioxide 5.0to20.0ppm 15ppm
ChlorineDioxide 0to1ppmonly 1ppm
NitrogenMonoxide 0to100ppm 100ppm
NitrogenDioxide 5to50ppm 10ppm
Hydrogen 0to1000ppmonly 1000ppm
Hydrogen 0to10,000ppmonly 10,000ppm
HydrogenChloride 10to20ppm 10ppm
HydrogenCyanide 0to20ppmonly 20ppm
HydrogenFluoride 0to12ppmonly 12ppm
Ammonia* 50to200ppm 200ppm
Ammonia* 200to1,000ppm 1,000ppm
Phosphine 0to1.2ppmonly 1.2ppm
Electrical
Connections and Power 2-wirelooppowered 17Vdc(+/-10%)to24Vdc(max)operation 22mAmax.overrange
Recommended Cable 2-wirewithscreen(90%coverage)orconduit 0.5mm2(20AWG)to2.0mm2(14AWG)
Signal 0-100%FSD4-20mA Fault=3mA Calibrationdueselectableoffor3mA Max.overrange22mA Inhibit(toxicsensors)=Selectable3mAor4mAInhibit (Oxygensensors)=Selectable3mAor17.4mA
Construction
Material Transmitter:PaintedaluminiumADC12,Sensor:316stainlesssteelwithPTFEfilter
Maximum Dimensions 150x185x80mm 5.9x7.3x3.2inches(excludingmountingbracket)
Weight 1450g(3.3lbs)
Environmental
IP Rating IP66(EN60529:1992),NEMA4X
Operating Temperature -20°Cto+55°C(-4°Fto131°F) -20OCto+40OC(-4OFto+104OF)NH3Sensor
Operating Humidity Continuous20-90%RH(non-condensing) Intermittent0-99%RH(non-condensing)
Operating Pressure 90-110kPa
Storage Conditions 15°Cto30°C(59°Fto86°F) 30-70%RH(non-condensing)
Certification UL/c-ULClasslDiv1&2,GroupsB,C&D-40°Cto+55°C UL/c-ULClassllDiv1&2,GroupsE,F&G-40°Cto+55°C ATEXII2GExd[ia]IIB+H2T4(Tamb-20°Cto+55°C/-4°Fto131°F) IECExExd[ia]IIB+H2T4
Approvals CEcompliantinaccordancewith: EMCDirective89/336/EECasamendedby92/31/EEC ATEXDirective94/9/EC
* Suitable for applications without NH3 ambient background concentrations only.
Technical Summary
Ordering Information
Ordering Information
A complete assembly consists of two parts, a transmitter and sensor which must be ordered separately.
• Transmitter PN#: Two certified versions are available: - S3KAX ATEX and IECEx certified S3KUX UL and CSA (c-UL) certified • Sensor PN#: All certified ATEX, IECEx, UL, CSA (c-UL) with two digits to specify gas type and range: - e.g. S3KXXC1SS (C1 denotes Carbon Monoxide, with a default range of 0-300ppm and user configurable for ranges from 0-100ppm to 0-999ppm)
Transmitter
S3KXX Series3000XPIStransmitterissuppliedcompletewithwallorpipemountingbracket,1x¾”NPTcable entry,1x¾”NPTtoM20adaptor,1xhexwrenchset,weatherproofcover,operatingmagnet, configuration/testcertificateandinstructionmanual.Unitsare100%inspectedpriortodespatchfromthe factory.Ordertherequiredsensorseparately.
Sensor Part Numbers and Available Gases
S3KXSO1SS Oxygen0-25%VOL
S3KXSC1SS CarbonMonoxide0-300ppm(default)0-100to0-999ppmselectable
S3KXSH1SS HydrogenSulphide0-15ppm(default)0-10to0-50ppmselectable
S3KXSH2SS HydrogenSulphide0-100ppm(default)0-50to0-500ppmselectable
S3KXSL1SS Chlorine0-5ppm(default)0-5to0-20ppmselectable
S3KXSZ1SS Ozone0-0.4ppm(default)0-0.4only
S3KXSS1SS SulphurDioxide0-15ppm(default)0-5to0-20ppmselectable
S3KXSX1SS ChlorineDioxide0-1ppm(default)0-1ppmselectable
S3KXSM1SS NitrogenMonoxide0-100ppm(default)0-100ppmselectable
S3KXSN1SS NitrogenDioxide0-10ppm(default)0-5to0-50ppmselectable
S3KXSG1SS Hydrogen0-1000ppm(default)0-1000ppmselectable
S3KXSG2SS Hydrogen0-10,000(default)0-10,000selectable
S3KXSR1SS HydrogenChloride0-10ppm(default)0-10to0-20ppmselectable
S3KXSY1SS HydrogenCyanide0-20ppm(default)0-20ppmselectable
S3KXSF1SS HydrogenFluoride0-12ppm(default)0-12ppmselectable
S3KXSA1SS Ammonia0-200ppm(default)0-50to0-200ppmselectable
S3KXSA2SS Ammonia0-1000ppm(default)0-200to0-1,000ppmselectable
S3KXSP1SS Phosphine0-1.2ppm(default)0-1.2ppmselectable
Shipping Details
Shippingcartondimensions:L315mm(12.4”)xW230mm(9.0”)xD115mm(4.5”) Approximateweight:1.5kg(3.3lbs)
Optional Accessories
S3KCAL Calibrationgasflowhousing
SPPPCC Collectingconeforusewithlighterthanairgases(H2andCOonly**)
S3KDMK Ductmountingkit(H2,CO&H2Sonly**)
S3KRMK Remotesensormountingkitincludes:enclosurewithsensor socket,15mofdigitalcableandglands,transmittercable plug,mountingscrews
CalibrationGases ContactHoneywellAnalyticsrepresentative
Note: ** Contact a Honeywell Analytics representative for the suitbalitiy of accessories for other gases.
1211
3H_Series 3000_DS01057_V1_EMEA
10/07
© 2007 Honeywell Analytics
Find out more
Contact Honeywell Analytics:
www.honeywellanalytics.com
Europe, Middle East, Africa
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
Americas
Honeywell Analytics Distribution, Inc. 405 Barclay Blvd.Lincolnshire, IL 60069USATel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 [email protected]
www.honeywell.com
Technical [email protected]
Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (1) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050, Korea Tel: +82 (0)2 2025 0307 Fax: +82 (0)2 2025 [email protected]
Please Note:Whileeveryefforthasbeenmadetoensureaccuracyinthispublication,noresponsibilitycanbeacceptedforerrorsoromissions.Datamaychange,aswellaslegislation,andyouarestronglyadvisedtoobtaincopiesofthemostrecentlyissuedregulations,standards,andguidelines.Thispublicationisnotintendedtoformthebasisofacontract.
Technical ServicesAt Honeywell Analytics, we believe in the value of great service and customer care. Our key commitment is providing complete and total customer satisfaction. Here are just a few of the services we can offer:
Full technical support
Expert team on hand to answer questions and queries
Fully equipped workshops to ensure quick turnaround on repairs
Comprehensive service engineer network
Training on product use and maintenance
Mobile calibration service
Customised programmes of preventative/corrective maintenance
Extended warranties on products
»»
»
»»»»
»
Our Product Range
Fixed Gas MonitoringHoneywell Analytics offers a wide range of fixed gas detection solutions for a diverse array of industries and applications including: Commercial properties, industrial applications, semiconductor manufacturers, energy plants and petrochemical sites.
Detection of flammable, oxygen and toxic gases (including exotics)
Innovative use of 4 core sensing technologies–papertape, electrochemical cell, catalytic bead and infrared
Capability to detect down to Parts Per Billion (ppb) or Percent by Volume (%v/v)
Cost effective regulatory compliance solutions
»
»
»
»
Portable Gas MonitoringWhen it comes to personal protection from gas hazards, Honeywell Analytics has a wide range of reliable solutions ideally suited for use in confined or enclosed spaces. These include:
Detection of flammable, oxygen and toxic gases
Singlegaspersonalmonitors–wornby the individual
Multi-gasportablegasmonitors–used for confined space entry and regulatory compliance
Multi-gastransportablemonitors–used for temporary protection of area during site construction and maintenance activities
»
»
»
»Find out more
Contact Honeywell Analytics:
www.honeywellanalytics.com
Europe, Middle East, Africa
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
Americas
Honeywell Analytics Distribution, Inc. 405 Barclay Blvd.Lincolnshire, IL 60069USATel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 [email protected]
www.honeywell.com
Technical [email protected]
Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (1) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050, Korea Tel: +82 (0)2 2025 0307 Fax: +82 (0)2 2025 [email protected]
Find out more
Contact Honeywell Analytics:
www.honeywellanalytics.com
Europe, Middle East, Africa
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
Americas
Honeywell Analytics Distribution, Inc. 405 Barclay Blvd.Lincolnshire, IL 60069USATel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 [email protected]
www.honeywell.com
Technical [email protected]
Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (1) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050, Korea Tel: +82 (0)2 2025 0307 Fax: +82 (0)2 2025 [email protected]
Find out more
Contact Honeywell Analytics:
www.honeywellanalytics.com
Europe, Middle East, Africa
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
Americas
Honeywell Analytics Distribution, Inc. 405 Barclay Blvd.Lincolnshire, IL 60069USATel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 [email protected]
www.honeywell.com
Technical [email protected]
Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (1) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050, Korea Tel: +82 (0)2 2025 0307 Fax: +82 (0)2 2025 [email protected]