series 9000 , avenir , kick & ap40 base power-in · base power-in breakaway base power-in *...

7
System Flag Color -3-Circuit, Shared Neutral and System Ground (SHN) Black -4-Circuit, 3 with Shared Neutral and System Ground and 1- Isolated Circuit and Ground (3+D) Black Optional Wiring Schematics: System Flag Color -2-General Circuits with Shared Neutral & System Ground and 2-Isolated circuits with Shared Neutral and Isolated Ground (2+2) Grey -3-Separate Circuits - 2 with own Neutral and Isolated Ground, 1 with own Neutral and System Ground (SPN) White -4-Circuit - 3 with Shared Neutral and Isolated Ground, 1-Circuit with System Ground (3I+1) Tan Base Power-In Breakaway Base Power-In * Available as replacement parts only. WARNING: All electrical installations should be done by a qualified person in accordance with codes and regulations applicable at the installation site. Circuits should be checked for proper voltages. Page 1 of 7 939503131 Rev R If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for immediate action by people who want to help you. (Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: 1.616.247.2500) Or visit our website: www.steelcase.com © 2004 Steelcase Inc. Grand Rapids, MI 49501 U.S.A. Printed in U.S.A. Series 9000 ® , Avenir ® , kick ® & ap40 Base Power-In Models: 5-WIRE (98669, TSAE98669) 8-WIRE (98669-4, TSAE986694) 5 & 8-WIRE (TKBPI) Models: 5-WIRE (98669-C, TSAE98669C) 8-WIRE (98669-4-C, TSAE986694C) 5 & 8-WIRE (TKBBPI) NOTE: The electrician can cut conduit and wire to length if needed.

Upload: others

Post on 28-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Series 9000 , Avenir , kick & ap40 Base Power-In · Base Power-In Breakaway Base Power-In * Available as replacement parts only. WARNING: All electrical installations should be done

System Flag Color

-3-Circuit, Shared Neutral and System Ground (SHN) Black

-4-Circuit, 3 with Shared Neutral and System Ground

and 1- Isolated Circuit and Ground (3+D) Black

Optional Wiring Schematics: System Flag Color

-2-General Circuits with Shared Neutral & System Ground

and 2-Isolated circuits with Shared Neutral and Isolated Ground (2+2) Grey

-3-Separate Circuits - 2 with own Neutral and Isolated Ground,

1 with own Neutral and System Ground (SPN) White

-4-Circuit - 3 with Shared Neutral and Isolated Ground,

1-Circuit with System Ground (3I+1) Tan

Base Power-In Breakaway Base Power-In

* Available as replacement parts only.

WARNING: All electrical installations should be done by a qualifiedperson in accordance with codes and regulations applicable at the

installation site. Circuits should be checked for proper voltages.

Page 1 of 7939503131 Rev R

If you have a problem, question, or request, callyour local dealer, or Steelcase Line 1 at888.STEELCASE (888.783.3522)for immediate action by people who want to help you.

(Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: 1.616.247.2500)Or visit our website: www.steelcase.com© 2004 Steelcase Inc. Grand Rapids, MI 49501 U.S.A.

Printed in U.S.A.

Series 9000®, Avenir®, kick® & ap40™

Base Power-In

Models:5-WIRE (98669, TSAE98669)8-WIRE (98669-4, TSAE986694)

5 & 8-WIRE (TKBPI)

Models:5-WIRE (98669-C, TSAE98669C)8-WIRE (98669-4-C, TSAE986694C)

5 & 8-WIRE (TKBBPI)

NOTE: The electrician can cut conduit and wire to length if needed.

Page 2: Series 9000 , Avenir , kick & ap40 Base Power-In · Base Power-In Breakaway Base Power-In * Available as replacement parts only. WARNING: All electrical installations should be done

Page 2 of 7939503131 Rev R

Wiring Schematic

GROUND

P-1 P-2 P-3

NEUTRAL

LINE 1

LINE 1

LINE 3

LINE 2

SHARED NEUTRAL

SYSTEM GROUND

ISOLATED GROUND

LINE 2 LINE 3

LINE 4

SHARED NEUTRAL

NOTE:L-1, L-2, & L-3 are connected to P-1, P-2 & P-3 respectively.L-4 is connected to P-1 or P-2 only and not to the samephase as L-3.

NOTE:L-1, and L-2 must be connected to different phases.L-3 and L-4 must be connected to different phases.

NEUTRAL A

NEUTRAL

GROUND

GROUND

GROUND

NEUTRAL BNEUTRAL C

ISOLATED GROUND

P-1 P-2 P-3

NEUTRAL

LINE 1

LINE 1Red

Black

Red

Blue

Red

BluePink

White/Red LettersGray

White/Black LettersGreen/YellowGreen

Black

Red

PinkBlue

Blue

Pink

LINE 2

SHARED NEUTRA LWhite/ Black Letters

White/Red Letters

Gray

Green/Yellow

Green

Whi

te/R

ed L

ette

rs

Whit

e/Blac

k Let

ters

Whit

e/Red

Let

ters

Green

Green

/Yell

ow

Gre

en/Y

ello

w

Whi

te/B

lack

Let

ters

Gre

en

SYSTEM GROUNDLINE 3

LINE 4

SHARED NEUTRAL

ISOLATED GROUND

LINE 2

P-1 P-2 P-3

NEUTRAL

LINE 3 LINE 4

SYSTEM GROUND

P-1 P-2 P-3LINE A

LINE A

LINE C

LINE B

LINE B LINE C

2+2 - Powered by Separate Panels

GROUND

GROUND

P-1 P-2 P-3

NEUTRAL

NEUTRAL

LINE A

LINE A

LINE B

NEUTRAL ANEUTRAL B

ISOLATED GROUND LINE C

NEUTRAL C

SYSTEM GROUND

LINE B

P-1 P-2 P-3LINE C

3 Circuit, Separate Neutrals Powered by Separate Panels 3 Circuit, Separate Neutrals Powered by Single Panels

WARNING:

Risk of Fire or Electric Shock: This office furnishing systemmay be connected to more than one source of supply. All

sources must be disconnected prior to any servicing.No single circuit may be powered by more than one source.

2+2 - Powered by Single Panels

ELECTRICAL DATA:125 V 60 HZ 20 Amp USA/CANADA

208Y/120 VAC 3-Phase Service250/125 VAC 1-Phase Service

Wiring schematics must be followedto prevent overloading of the neutrals.

Pink

Page 3: Series 9000 , Avenir , kick & ap40 Base Power-In · Base Power-In Breakaway Base Power-In * Available as replacement parts only. WARNING: All electrical installations should be done

Wiring Schematic

GROUND

GROUND

GROUND

GROUND

P-1 P-2 P-3

NEUTRAL

LINE 1

LINE 1Red

Pink

Black

Blu e LINE 3

LINE 2

SHARED NEUTRALWhite/Black Letters

Whi

te/R

ed L

ette

rs

Gre

en

Green/Yellow

SYSTEM GROUND

LINE 4

NEUTRAL

ISOLATED GROUND

LINE 3

SHARED NEUTRAL

SYSTEM GROUND

LINE 2

P-1 P-2 P-3

NEUTRAL

LINE 3

LINE 4

P-1 P-2 P-3

NEUTRAL

LINE 1

LINE 1Red

Black

Pink

Gray

Blue LINE 3

3+D - Powered by Separate Panels 3+D Powered by Single Panel

LINE 2

SHARED NEUTRALWhite

Green SYSTEM GROUNDLINE 4

NEUTRAL

ISOLATED GROUND

LINE 2

P-1 P-2 P-3

NEUTRAL

LINE 3

LINE 4

GROUND

P-1 P-2 P-3

NEUTRAL

LINE 1

LINE 1Red

BlackBluePink

Whit

e

Gray

Green

Green

/Yell

ow

LINE 3

LINE 2

NEUTRAL

SYSTEM GROUND

ISOLATED GROUND

LINE 2 LINE 3

LINE 4

SHARED NEUTRAL

GROUND

P-1 P-2 P-3

NEUTRAL

LINE 1

LINE 1Red

BlackBlue

White

Green

White

Green

LINE 2

LINE 2 LINE 3

3I+1 - Powered by Separate Panels

LINE 3

SHARED NEUTRAL

SYSTEM GROUNDGROUND

P-1 P-2

NEUTRAL

LINE 1

LINE 1Red

Black

BlueLINE 2

LINE 2

3I+1 - Powered by Single Panel

NOTE:L-4 may be connectedto P-1, P-2, or P-3

NOTE:L-4 may be connectedto P-1, P-2, or P-3

NOTE:L-3 must be omitted or connected to the load side of L-1 or L-2.

NOTE:L-4 should alternate between P-1, P-2, and P-3 to balance circuit loading.

GROUND

P-1 P-2 P-3

NEUTRAL

LINE 1

LINE 1Red

BlackBluePink

Whit

e/Blac

k Let

ters

Whit

e/Red

Let

ters

Green

Green

/Yell

ow

LINE 3

LINE 2

NEUTRAL

SYSTEM GROUND

ISOLATED GROUND

LINE 2 LINE 3

LINE 4

SHARED NEUTRAL

NOTE:L-4 should alternate between P-1, P-2, and P-3 to balance circuit loading.

WARNING:

Risk of Fire or Electric Shock: This office furnishing systemmay be connected to more than one source of supply. All

sources must be disconnected prior to any servicing.No single circuit may be powered by more than one source.

ELECTRICAL DATA:125 V 60 HZ 20 Amp USA/CANADA

208Y/120 VAC 3-Phase Service250/125 VAC 1-Phase Service

Wiring schematics must be followedto prevent overloading of the neutrals.

Gre

en/Y

ello

w

3 Circuit, Shared Neutral 3 Circuit, Shared Neutral Powered by Split Phase Panel

Page 3 of 7939503131 Rev R

Page 4: Series 9000 , Avenir , kick & ap40 Base Power-In · Base Power-In Breakaway Base Power-In * Available as replacement parts only. WARNING: All electrical installations should be done

Page 4 of 7939503131 Rev R

For duplex opening, removeknockout plate shown bystriking from the backside of the base trimin indicated area withchannel lock pliers.

For Triplex opening afterremovingduplex, remove theremaining knockout plate bystriking from the back side ofthe base trim in the indicatedarea with the channel lockpliers.

NOTE: If knockoutplate does not fullydisengage, grasp platewith pliers from frontside and gently moveback and forth tocomplete removal.

1. Remove base trim.

2. Remove access cover. Series 9000 / ap40 Avenir / kick

Page 5: Series 9000 , Avenir , kick & ap40 Base Power-In · Base Power-In Breakaway Base Power-In * Available as replacement parts only. WARNING: All electrical installations should be done

3. 3a.

Power-in

Conduit end

Base trim

NOTE: Loosen nut andside as indicated

Page 5 of 7939503131 Rev R

NOTE: When Base Power-in is alreadywired to the building power system,feed into base trim as shown below.

Page 6: Series 9000 , Avenir , kick & ap40 Base Power-In · Base Power-In Breakaway Base Power-In * Available as replacement parts only. WARNING: All electrical installations should be done

Green end

Right side of powerway

Base power-in

Page 6 of 7939503131 Rev R

4. Attach base power-in to powerway.

NOTE: Base Power-in can only be connected togreen end of powerway.

NOTE: THE QUALIFIED ELECTRICIAN CAN CUT THEHARNESS TO LENGTH (WIRE END), MAKING SURETHE UL LABEL IS INSTALLED ON HARNESS.

Page 7: Series 9000 , Avenir , kick & ap40 Base Power-In · Base Power-In Breakaway Base Power-In * Available as replacement parts only. WARNING: All electrical installations should be done

5. 6.

NOTE: Reposition nut and hand tighten.

Page 7 of 7939503131 Rev R

Series 9000 / ap40 Avenir / kick