series_dr_v1.50_hr
TRANSCRIPT
-
7/27/2019 series_dr_v1.50_hr
1/9
Datasheet
Proven Reliability
Designed for snap-on-back panel railmounting on either a 35mm x 7.5mm,or a 35mm x 15mm Symmetrical DinRail, allowing rapid and simple mountingand removal of the breaker. It featuresrecessed, wire-ready, touch-proof, shock-resistant terminals, suitable for automaticscrewdriver assembly, as well as "DeadFront" construction characteristics.
Features:
Blue housing
1-4 poles,
0.1 - 50 amps,up to 277VAC / 480VAC WYEor 65VDC
Precise, temperature independant,operation
Choice of time delays, terminals andactuator colors.
Our Circuit Breakers are designed accordingto railway regulations:
- IEC 60077 - 1/2/3
- NF F62-001 - 1/2/3
- EN 45545-2 & NF F16-101/102(fire and toxic regulations)
-
7/27/2019 series_dr_v1.50_hr
2/9
Genaral tecnical dats
ElectricalMaximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz, 65VDCStandard current coils 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0,
35.0, 40.0 & 50.0. Other ratings available - consult factory.Standard Voltage Coils DC - 6V, 12V; AC - 120V, other ratings available, see ordering scheme.Insulation Resistance Minimum: 100 Megohms at 500 VDCDielectric Strength 1960 V 50/60 Hz for one minute between all electrically isolated terminals.
DR-Series circuit breakers comply with the 8mm spacing and 3750V 50/60 Hzdielectric requirements from hazardous voltage to operator accessible surfacesand between adjacent poles.
MechanicalEndurance 10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage.
Trip Free All DR-Series Circuit Breakers will trip on overload, even when the actuator isforcibly held in the ON position.
Trip Indication The operating actuator moves positively to the OFF position when an overloadcauses the circuit breaker to trip.
PhysicalNumber of Poles 1 - 4 PolesInternal Circuit Configuration Switch Only and Series Trip with current or voltage trip coilsWeight Approximately 128 grams/pole (Approximately 4.57 ounces/pole)Standard Colors Housing - Blue; Actuator - White with dual legends.Mounting Mounts on a standard 35mm Symmetrical DIN Rail (35 x 7.5 or 35 x 15mm).
EnvironmentalShock Withstands 100 Gs, 6ms, sawtooth while carrying rated current.
Vibration Withstands 0.060" excursion from 10-55 Hz, and 10 Gs 55-500 Hz.Moisture Resistance Ten 24-hour cycles @ + 25C to +65C, 80-98% RH.Salt Spray 90-95% RH @ 5% NaCl Solution, 96 hrs.Thermal Shock Five cycles @ -55C to +25C to +85C to +25C.Operating Temperature -40 C to +85 C
16.67
Time in
Milliseconds
t
12xMultipleof
RatedCurrent
rI
4.165 8.33
25x
Time Delay Curves
22, 24 & 26
(50 Amps Max.)
60 Hz 1/2 Cycle
Inrush Pulse Tolerance
Time Delay Curves
42, 44 & 46
(50 Amps Max.) Time Delay Curves
42, 44 & 46
(50 Amps Max.)
5.0 20.0
Time in
Milliseconds
t
50 Hz 1/2 Cycle
Inrush Pulse Tolerance
Time Delay Curves
22, 24 & 26
(50 Amps Max.)
10.0
22x
10x
Multipleof
RatedCurrent
rI
Pulse Tolerance Curves
0.01
0.0010.01 0.1
1000
100
10
1
0.1
O
H
M
S
1 10 100
AMPERE RATING
RESISTANCE, IMPEDANCE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
CURRENT(AMPS)
0.10 - 5.05.1 - 20.0
15% 25%
TOLERANCE(%)
20.1 - 50.0 35%
Resistance, Impedance
2 http://www.morssmittrelais.com
General technical specifications - DR-Series
-
7/27/2019 series_dr_v1.50_hr
3/9
3http://www.morssmittrelais.com
3Current Rating
5Circuit
2Poles
DR 244
Frequency& Delay
1Series
1 6107
ActuatorColor
6Actuator
9Mounting/
Voltage
8Terminal
A 1 12B0
2 POLES
1 One 2 Two 3 Three 4 Four
4 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only105 DC Instantaneous11 DC Ultra Short12 DC Short14 DC Medium16 DC Long205 50/60Hz Instantaneous21 50/60Hz Ultra Short22 50/60Hz Short
24 50/60Hz Medium26 50/60Hz Long32 DC, 50/60Hz Short34 DC, 50/60Hz Medium36 DC, 50/60Hz Long426 50/60Hz Short, Hi-Inrush446 50/60Hz Medium, Hi-Inrush466 50/60Hz Long, Hi-Inrush
5 CIRCUIT
A0 Switch Only (No Coil) 4
B0 Series Trip (Current)C0 Series Trip (Voltage)
6 ACTUATOR 1
A2 Handle, one per poleB2 Handle, one per multipole unit
1 SERIES
DR
7 ACTUATOR COLOR & LEGEND
Actuator Color I-O Dual Legend Color White A 1 BlackBlack C 2 WhiteRed F 3 WhiteGreen H 4 WhiteBlue K 5 WhiteYellow M 6 BlackGray P 7 BlackOrange R 8 Black
Ordering Scheme - DR-Series
3 CURRENT RATING (AMPERES)
OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS) 5
210 0.100
215 0.150220 0.200225 0.250230 0.300235 0.350240 0.400245 0.450250 0.500255 0.550260 0.600265 0.650270 0.700275 0.750280 0.800285 0.850290 0.900295 0.950410 1.000
512 1.250
413 1.300414 1.400415 1.500517 1.750420 2.000522 2.250425 2.500527 2.750430 3.000532 1.300435 3.250436 3.600440 4.000445 4.500547 4.750450 5.000455 5.500460 6.000
465 6.500
470 7.000572 7.250475 7.500480 8.000485 8.500490 9.000495 9.500610 10.000710 10.500611 11.000711 11.500612 12.000712 12.500613 13.000614 14.000615 15.000616 16.000617 17.000
618 18.000
619 19.000620 20.000621 21.000622 22.000623 23.000624 24.000625 25.000626 26.000627 27.000628 28.000629 29.000630 30.000632 32.000635 35.000640 40.000645 45.000650 50.000
A06 6 DC, 5 DCA12 12 DC, 10 DCA18 18 DC, 15 DCA24 24 DC, 20 DCA32 32 DC, 25 DC
A48 48 DC, 40 DCA65 65 DC, 55 DC
J06 6 AC, 5 ACJ12 12 AC, 10 ACJ18 18 AC, 15 AC
J24 24 AC, 20 ACJ48 48 AC, 40 ACK20 120 AC, 65 ACL40 240 AC, 130 AC
9 MOUNTING/VOLTAGE
MOUNTING STYLE VOLTAGEThreaded Insert
1 6-32 x 0.195 inches < 3002 ISO M3 x 5mm < 300
8 TERMINAL
1 #10 Screw & Pressure Plate for Direct Wire Connection2 #10 Screw without Pressure Plate
10Agency
approval
1
* Other values on request
10 AGENCY APPROVAL
112 UL-Recognized, CSA, TUV to EN60077 and NF F62-001
Notes:1 Handle breakers available up to four poles.2 Actuator Code:
A: Multi-pole units factory assembled with common handle tie.B: Handle location as viewed from front of breaker:
2 pole - left pole3 pole - center pole4 pole - two handles at center poles
4 30A, select Current Rating code 630. 31-50A, select Current Rating code 650.5 Voltage coil only available with delay codes 10 & 20.6 Available to 50A max with circuit code BO only.8 Color shown is visi and legend with remainder of rocker black.12 Preliminary test results showed that the breakers comply to the EN60077 and NF F62-001.
Certificates for UL-Recognized and CSA are available on request. For the EN60077 andNF F62-001 the certificates will be available in short notice.
-
7/27/2019 series_dr_v1.50_hr
4/9
4 http://www.morssmittrelais.com
DELAY 100% 125% 135% 150% 200% 400% 600% 800% 1000% 1200%
10 No Trip May Trip --- .032 MAX .024 MAX .020 MAX .018 MAX .016 MAX .015 MAX .013 MAX
11 No Trip .013 - .125 --- .010 - .070 .008 - .032 .006 - .020 .005 - .020 .004 - .020 .004 - .020 .004 - .020
12 No Trip .500 - 6.50 --- .300 - 3.00 .130 - 1.20 .031 - .220 .011 - .120 .004 - .090 .004 - .060 .004 - .040
14 No Trip 2.00 - 60.0 --- 1.20 - 40.0 .600 - 20.0 .150 - 3.00 .030 - 1.30 .004 - .600 .004 - .100 .004 - .100
16 No Trip 45.0 - 345 --- 20.0 - 150 9.00 - 60.0 1.40 - 11.4 .150 - 5.80 .009 - 3.70 .005 - 1.70 .005 - .500
20 No Trip May Trip --- .040 MAX .035 MAX .030 MAX .025 MAX .020 MAX .017 MAX .015 MAX
21 No Trip .014 - .150 --- .011 - .095 .008 - .055 .006 - .035 .005 - .027 .005 - .021 .004 - .018 .004 - .017
TRIP 22 No Trip .700 - 12.0 --- .350 - 4.00 .130 - 1.30 .027 - .220 .008 - .130 .004 - .090 .004 - .045 .004 - .040
TIME 24 No Trip 10.0 - 160 --- 6.00 - 60.0 2.20 - 20.0 .300 - 3.00 .050 - 1.30 .007 - .500 .005 - .060 .005 - .040
(SECONDS) 26 No Trip 50.0 - 700 --- 32.0 - 350 10.0 - 90.0 1.50 - 15.0 .500 - 7.00 .020 - 3.00 .006 - 2.00 .005 - 1.00
32 No Trip May Trip .400 - 8.00 .300 - 4.00 .130 - 1.30 .027 - .220 .008 - .130 .004 - .090 .004 - .060 .004 - .040
34 No Trip May Trip 1.80 - 100 1.20 - 60.0 .600 - 20.0 .150 - 3.00 .030 - 1.30 .004 - .600 .004 - .110 .004 - .100
36 No Trip May Trip 35.0 - 520 20.0 - 350 9.00 - 90.0 1.40 - 15.0 .150 - 7.00 .009 - 3.70 .005 - 2.00 .004 - 1.00
42 No Trip .700 - 12.0 --- .400 - 6.00 .180 - 2.30 .050 - .600 .026 - .300 .018 - .200 .014 - .150 .012 - .130
44 No Trip 7.00 - 100 --- 3.00 - 50.0 1.10 - 18.0 .220 - 3.00 .120 - 1.70 .075 - 1.20 .050 - .850 .042 - .720
46 No Trip 50.0 - 700 --- 31.0 - 350 12.0 - 150 1.50 - 20.0 .700 - 10.0 .404 - 7.90 .260 - 6.50 .198 - 5.80
PERCENT OF RATED CURRENT
NOTES:Delay Curves 11,12,14,16,21,22,24,26,42,44,46: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve.
Delay Curves 32,34,36: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve.Delay Curves 10,20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve.All Curves: Curve data shown represents breaker response at ambient temperature of 25C (77F) with no preloading. Breakers are mounted in standard wall-mount position.On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 25 times the rated current on high inrush delays. These val-ues are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitiveloads and transformer loads.
High Inrush AC
Short Medium Long
Time Delay Values - DR-Series
700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 Hz - HI-INRUSHSHORT DELAYCURVE NO. 42
PERCENT OF RATED CURRENT
TRIPTIMEIN
SECONDS
150125
100 200 300 400 500 600 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 Hz - HI-INRUSHMEDIUM DELAYCURVE NO. 44
100 200 300 400 500 600 700
PERCENT OF RATED CURRENT
TRIPTIMEIN
SECONDS
150
125
900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 Hz - HI-INRUSHLONG DELAYCURVE NO. 46
150125
100 200 300 400 500 600 700 800
TRIPTIMEIN
SECONDS
PERCENT OF RATED CURRENT
AC
1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzINSTANTANEOUS
CURVE NO. 20
150
125
100 200 300 400 500 600 700 800 900
TRIPTIMEIN
SECONDS
PERCENT OF RATED CURRENT
Instantaneous Ultrashort Short
Medium Long
300 400 500 600 700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
TRIPTIMEIN
SECONDS
PERCENT OF RATED CURRENT150
125
100 200
50/60 HzULTRASHORT DELAY
CURVE NO. 21
800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzSHORT DELAYCURVE NO. 22
TRIPTIMEIN
SECONDS
PERCENT OF RATED CURRENT150125
100 200 300 400 500 600 700
700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzMEDIUM DELAYCURVE NO. 24
150
125
100 200 300 400 500 600
PERCENT OF RATED CURRENT
TRIPTIMEIN
SECONDS
700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
50/60 HzLONG DELAYCURVE NO. 26
150
125
100 200 300 400 500 600
PERCENT OF RATED CURRENT
TRIPTIMEIN
SECONDS
-
7/27/2019 series_dr_v1.50_hr
5/9
5http://www.morssmittrelais.com
DC
AC/DC
Short Medium Long
Medium Long
Instantaneous Ultrashort Short
1100 1200
10000
1000
100
10
1
.1
.01
.001
TRIPTIMEIN
SECOND
S
PERCENT OF RATED CURRENT
1000
D.C.
INSTANTANEOUSCURVE NO. 10
150
900800700600500400300200100
125
700 800 900 1000 1100 1200
TRIPTIMEIN
SECO
NDS
10000
1000
100
10
1
.1
.01
.001
PERCENT OF RATED CURRENT
100 200 300 400 500 600
D.C.ULTRASHORT DELAY
CURVE NO. 11
150
125
800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
PERCENT OF RATED CURRENT
D.C.SHORT DELAYCURVE NO. 12
125
100 200 300 400 500 600 700
TRIPTIMEIN
SECON
DS
150
Time Delay Values - DR-Series
600 700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001100 200 300 400 500
125
150
TRIPTIM
EIN
SECONDS
PERCENT OF RATED CURRENT
D.C.MEDIUM DELAYCURVE NO. 14
900 1000 1100 1200100 200 300
1000
100
10
1
.1
.01
.001
150
125
400 500 600 700 800
D.C.
LONG DELAYCURVE NO. 16
TR
IPTIMEIN
SECONDS
PERCENT OF RATED CURRENT
.1
.01
.001
150135
100 200 300 400 500 600 700 800 900 1000 1100 1200
D.C., 50/60 HzSHORT DELAYCURVE NO. 32
10000
1000
100
10
1
TRIPT
IMEIN
SECONDS
PERCENT OF RATED CURRENT
600 700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.001
.01
D.C., 50/60 HzMEDIUM DELAYCURVE NO. 34
PERCENT OF RATED CURRENT
TRIPTIMEIN
SECONDS
150135
100 200 300 400 500 700 800 900 1000 1100 1200
10000
1000
100
10
1
.1
.01
.001
TRIPTIMEIN
SECONDS
PERCENT OF RATED CURRENT
D.C., 50/60 HzLONG DELAYCURVE NO. 36
150135
100 200 300 400 500 600
-
7/27/2019 series_dr_v1.50_hr
6/9
All dimensions in inches and [mm]
6 http://www.morssmittrelais.com
Circuit & Terminal Diagrams - DR-Series
P0LE3
P0LE2
P0LE1
TABLE A
THREAD SIZE
#6-32 [M3] HARDWARE
#10-32 THD TERMINALSCREW
ON I
LINE
LOAD
.346 [8.79] TYP
(HANDLE ACTUATOR SHOWN)
HANDLE ACTUATORLINE
LOAD
SWITCH ONLY(2 TERM'S.)
2.920 [74.17] TYP
OFF
I
3.612 [91.75] TYP
TERMINALS ARE SUPPLIED WITH#10-32 SCREW AND PRESSURE
PLATE PER TERMINAL"
SERIES TRIP(2 TERM'S.)
LINE
LOAD
2.165 [54.99] TYP
1.240 [31.49] TYP
TORQUE
TIGHTENING TORQUE SPECIFICATIONS
LOAD
MULTI-POLE IDENTIFICATION SCHEME
LINE
15-20 IN-LBS[1.7-2.3 NM]
7-9 IN-LBS[0.8-1.0 NM]
-
7/27/2019 series_dr_v1.50_hr
7/9
7http://www.morssmittrelais.com
All dimensions in inches and [mm]
Form & Fit Drawings - DR-Series
LINE
TYP. PER POLE
#
#
MAX..755 [19.18]
DA1DB2DB3
TYP
ASSEMBLY
MAX.
.705 [17.91]
MAX.
.346 [8.79]
.775 [19.68]
LOAD
2.280 [57.91]
OFF
O
ONI
2-POLE(DA2)
MAX.
4-POLE(DA4)
2-POLE(DB2)
10-32 x .375 LONG SCREW(2 REQ'D) / POLE
3.040 [77.22]
.150 [3.81] TYP
1.681 [42.69]
.962 [24.43]
REMOVAL
TOLERANCES .005 [.12]
.750 [19.05]2.265 [57.53]
.750 [19.05]
MAX.
4-POLE(DB4)
SCREW DRIVER
1.410 [35.81]
1.438 [36.53] TYP
1-POLE(DA1)
.156 DIA [3.96]
2 PLC'S TYPPER POLE
30
60
.540 [13.72]
3.612 [91.75] TYP
DA4
DA3
DA2DB4
.750 [19.05]
1.515 [38.48]
2.165 [54.99] TYP
1.929 [49.00]
MULTI-POLE UNITSARE ASSEMBLED ATFACTORY WITHCOMMON HANDLE TIE
TYP. STANDARD 35mm SYMMETRICAL DIN RAIL(35 x 7.5 OR 35 x 15mm PER DIN EN50022).
.432 [10.97]
PANEL CUTOUT DETAIL
TYPICAL-OPTIONAL
6-32 [M3] THREAD x .195 [4.95] DEEP
2.920 [74.17] TYP
2.062 [52.37] TYP
(2 PLC'S.) / POLE
"ON-OFF, I-O" LEGEND
1.520 [38.61]
1.240 [31.49] TYP
.760 [19.30]
3.015 [76.58]
MAX.
1.515 [38.48]
.750 [19.05] 3.015 [76.58]
2.265 [57.53]
1.448 [36.78]
2.062 [52.37]
3-POLE(DA3)
3-POLE(DB3)
-
7/27/2019 series_dr_v1.50_hr
8/9
8Proven Reliability
MORS SMITT TECHNOLOGIES INC.
50 North New York AvenueHuntington, NY, 11743USATel. +1 (631) 271-8858Fax +1 (631) [email protected]
http://www.morssmittrelais.com
France USA
Your local distributor:
For further information please contact:
MS RELAIS SAS
Tour Rosny 2Avenue du Gnral de GaulleF - 93118 Rosny-sous-Bois CedexFranceTel. +33 (0)1 48 12 14 40Fax +33 (0)1 48 55 90 [email protected]
http://www.morssmittrelais.com
NIEAF-SMITT BV
Vrieslantlaan 6NL - 3526 AA, UtrechtThe NetherlandsTel. +31 (0)30 288 13 11Fax +31 (0)30 289 88 [email protected]
http://www.nieaf-smitt.nl/railway
The Netherlands
ComDocSolutions-2004
DS/GB DR-Series 1.50 / 04-04
-
7/27/2019 series_dr_v1.50_hr
9/9
Aust ral ian Dist ri bu to r
Relay Monitoring Systems Pty Ltd6 Anzed CourtMulgrave, Victoria, 3170, Australia
Phone: +61 3 8544 1200Fax: +61 3 8544 1201Email: [email protected]: www.rmspl.com.au
mailto:[email protected]://www.rmspl.com.au/http://www.rmspl.com.au/mailto:[email protected]