SERVICE BULLETIN. R&D/AC/SAC/. TV. WM. AC. Ref. MWO. No OF ISSUED :. 30/05/09. ISSUE DATE :. PROBLEMS DUE TO NO MEMORY BACKUP. SUBJECT. EA18SCRPA1. REMARKS :. Applicable Model. Applicable Sr. No. PROBLEM : WHEN COMPRESSOR STARTS, BLOWER MOTOR SPEED GOES VERY LOW. - PowerPoint PPT PresentationTRANSCRIPT
SERVICE BULLETINTV WM AC Ref. MWO No OF ISSUED :
ISSUE DATE :
SUBJECT
Applicable Model
Applicable Sr. No.
I/C : INTERCHANGEABILITY CODE N/C : NUMERAL CODEA Interchangeable:Old and new parts can be used in products 1 To improve performance
as the bulletin regardless of manufacture date 2 To improve productivity
R&D
BOld parts can be substituted for new parts : Old parts can be used in previous3 To improve reliability
products only. But new parts can be used regardless of manufacture date. 4 Change of material or dimension
CNew parts can be subtituted for old parts : Only new parts can be used5 Addition
in products regardless of manufacture date. 6 Deletion
Q.A.
D Not interchangeable : New pafts can be used in new products only. 7 Correction
PROBLEMS DUE TO NO MEMORY BACKUP
...
REMARKS :
30/05/09
R&D/AC/SAC/
PAGE 1
EA18SCRPA1
C.S.
PROBLEM: WHEN COMPRESSOR STARTS, BLOWER MOTOR SPEED GOES VERY LOW.
REASON: IT IS DUE TO DRY SOLDER AT MOTOR FEEDBACK CONNECTOR.
CORRECTIVE ACTION: RESOLDERING IS TO BE DONE AT 3& 5 PIN CONNECTORS.
STEP 1 DESOLDER THE CONNECTORS CN2,CN4 & CN6 (SEE FIG BELOW)
STEP 2 CLEAN CARBON WITH BRUSH/ PETROL
STEP3 RESOLDER CONNECTORS USING FLUX. (SEE FIG BELOW)
Applicable Model : EA18SCRPA1
CONNECTORS CN2 & CN4
STEP 1
STEP 3CONNECTOR CN6