Copyright © Siemens Industrial Turbomachinery Ltd 2011. All rights reserved.

SGT-300 Industrial Gas Turbinefor Mechanical Drive Applications

Page 2: Sgt300 md marketing rev1-moehlen

Page 2 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.

CM

Siemens range of gas turbines for mechanical drive applications SGT-300 8.2MW

Proven units for mechanical drive applications, widely used in the oil and gas industry, offering outstanding reliability, efficiency and

maintainability

33.7

38

Page 3: Sgt300 md marketing rev1-moehlen

Page 3 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.

CM

SGT-300 Industrial gas turbineKey performance data

Power 8.2 MW (intro)Speed rated 11500 rpmEfficiency 34.6% incl. in/out p

Page 4: Sgt300 md marketing rev1-moehlen

Page 4 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.

CM

SGT-300-2S Key Benefits Reliable: through field proven designs

Core engineCompressor: as used in the SGT-300, fleet operating hours >3.9millionCombustion: generic DLE combustion >8.5 million operating hoursTurbine: proven design & materials as used in SGT-100 through to SGT-800, conservative firing temperatureAll backed up by extensive validation programme

PackageGeneric package design, common modules across SGT-100 to SGT-400Focus on safety during operations and maintenance

Field proven designsSGT-300

Page 5: Sgt300 md marketing rev1-moehlen

Page 5 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.

CM

SGT-300-2S, SGT-200-2S,Taurus 70 & Mars 90Mechanical Drive, Full Load Output

5

6

7

8

9

10

11

12

-40 -30 -20 -10 0 10 20 30 40 50 60Tamb (degC)

Shaf

t Out

put (

MW

)

SGT300-2S introductory rating withhigh ambient power turbineSGT300-2S design rating with highambient power turbineT70 mechanical drive 2012

M90 mechanical drive 2012

SGT-200-2S (7.68MW rating)

SGT300-2S potential operation

Nominal outputzero inlet and exhaust lossesnatural gas fuelsea level T70 & M90 mechanical drive data from 2012 brochure

SGT-200-2S average engine from SIT_perf

SGT-300-2S Key Benefits High power at high ambient temperatures

SGT-300 can out perform Solar T70 over all ambient operating conditions

Page 6: Sgt300 md marketing rev1-moehlen

Page 6 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.

CM

SGT-300-2S, SGT-200-2S, Taurus 70 & Mars 90 Mechanical Drive, Full Load Efficiency

0.29

0.3

0.31

0.32

0.33

0.34

0.35

0.36

0.37

-40 -30 -20 -10 0 10 20 30 40 50 60Tamb (degC)

Ther

mal

Effi

cien

cy

SGT300-2S introductory rating

SGT300-2S introductory rating withhigh ambient power turbineSGT300-2S design rating with highambient power turbineT70 mechanical drive 2012

M90 mechanical drive 2012

SGT-200-2S (7.68MW rating)

Nominal outputzero inlet and exhaust lossesnatural gas fuelsea level T70 & M90 mechanical drive data from 2012 brochure

SGT-200-2S average engine from SIT_perf

SGT300-2S potential operation

SGT-300-2S Key Benefits High Efficiency

SGT-300 can match or beat Solar T70 efficiency over all ambient operating conditions

Page 7: Sgt300 md marketing rev1-moehlen

Page 7 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.

CM

SGT-300-2S Key BenefitsHigh Availability

Maintenance ProfileA-service (1 day) B-service (4 days)C-service (6 days)

> 99% availability

0 34 68 102 136

AA A

BB

AA A AA A AA A

C

OperatingHoursX 1,000

Modular Design Allows Service Flexibility

Page 8: Sgt300 md marketing rev1-moehlen

Page 8 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.

CM

SGT-300-2S Key BenefitsFuel Flexibility

Medium Calorific Value (MCV) High Calorific Value (HCV)‘’Normal’’

Wobbe Index (MJ/Nm³)

Low Calorific Value (LCV)

Pipeline Quality NG

37(86%CH4/14%N2)

49100%CH4)

Initial DLE Release Range

ExtensionHCV Fuels

ExtensionMCV Fuels

Fuel Capability Extension of standard fuel system

Planned Fuel Flexibility read across from Common Combustion Design

Page 9: Sgt300 md marketing rev1-moehlen

Page 9 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.

CM

SGT-300 Industrial gas turbineKey benefits

High reliability (evolutionary proven technology)Competitive power rating and efficiencyApplication flexibility –Mech. driveInherent fuel flexibility and low emissionsService friendly with high availability