sgt300 md marketing rev1-moehlen
TRANSCRIPT
![Page 1: Sgt300 md marketing rev1-moehlen](https://reader038.vdocument.in/reader038/viewer/2022100508/55c54a5dbb61eb4e6d8b45a6/html5/thumbnails/1.jpg)
Copyright © Siemens Industrial Turbomachinery Ltd 2011. All rights reserved.
SGT-300 Industrial Gas Turbinefor Mechanical Drive Applications
![Page 2: Sgt300 md marketing rev1-moehlen](https://reader038.vdocument.in/reader038/viewer/2022100508/55c54a5dbb61eb4e6d8b45a6/html5/thumbnails/2.jpg)
Page 2 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.
CM
Siemens range of gas turbines for mechanical drive applications SGT-300 8.2MW
Proven units for mechanical drive applications, widely used in the oil and gas industry, offering outstanding reliability, efficiency and
maintainability
33.7
38
![Page 3: Sgt300 md marketing rev1-moehlen](https://reader038.vdocument.in/reader038/viewer/2022100508/55c54a5dbb61eb4e6d8b45a6/html5/thumbnails/3.jpg)
Page 3 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.
CM
SGT-300 Industrial gas turbineKey performance data
Power 8.2 MW (intro)Speed rated 11500 rpmEfficiency 34.6% incl. in/out p
![Page 4: Sgt300 md marketing rev1-moehlen](https://reader038.vdocument.in/reader038/viewer/2022100508/55c54a5dbb61eb4e6d8b45a6/html5/thumbnails/4.jpg)
Page 4 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.
CM
SGT-300-2S Key Benefits Reliable: through field proven designs
Core engineCompressor: as used in the SGT-300, fleet operating hours >3.9millionCombustion: generic DLE combustion >8.5 million operating hoursTurbine: proven design & materials as used in SGT-100 through to SGT-800, conservative firing temperatureAll backed up by extensive validation programme
PackageGeneric package design, common modules across SGT-100 to SGT-400Focus on safety during operations and maintenance
Field proven designsSGT-300
![Page 5: Sgt300 md marketing rev1-moehlen](https://reader038.vdocument.in/reader038/viewer/2022100508/55c54a5dbb61eb4e6d8b45a6/html5/thumbnails/5.jpg)
Page 5 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.
CM
SGT-300-2S, SGT-200-2S,Taurus 70 & Mars 90Mechanical Drive, Full Load Output
5
6
7
8
9
10
11
12
-40 -30 -20 -10 0 10 20 30 40 50 60Tamb (degC)
Shaf
t Out
put (
MW
)
SGT300-2S introductory rating withhigh ambient power turbineSGT300-2S design rating with highambient power turbineT70 mechanical drive 2012
M90 mechanical drive 2012
SGT-200-2S (7.68MW rating)
SGT300-2S potential operation
Nominal outputzero inlet and exhaust lossesnatural gas fuelsea level T70 & M90 mechanical drive data from 2012 brochure
SGT-200-2S average engine from SIT_perf
SGT-300-2S Key Benefits High power at high ambient temperatures
SGT-300 can out perform Solar T70 over all ambient operating conditions
![Page 6: Sgt300 md marketing rev1-moehlen](https://reader038.vdocument.in/reader038/viewer/2022100508/55c54a5dbb61eb4e6d8b45a6/html5/thumbnails/6.jpg)
Page 6 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.
CM
SGT-300-2S, SGT-200-2S, Taurus 70 & Mars 90 Mechanical Drive, Full Load Efficiency
0.29
0.3
0.31
0.32
0.33
0.34
0.35
0.36
0.37
-40 -30 -20 -10 0 10 20 30 40 50 60Tamb (degC)
Ther
mal
Effi
cien
cy
SGT300-2S introductory rating
SGT300-2S introductory rating withhigh ambient power turbineSGT300-2S design rating with highambient power turbineT70 mechanical drive 2012
M90 mechanical drive 2012
SGT-200-2S (7.68MW rating)
Nominal outputzero inlet and exhaust lossesnatural gas fuelsea level T70 & M90 mechanical drive data from 2012 brochure
SGT-200-2S average engine from SIT_perf
SGT300-2S potential operation
SGT-300-2S Key Benefits High Efficiency
SGT-300 can match or beat Solar T70 efficiency over all ambient operating conditions
![Page 7: Sgt300 md marketing rev1-moehlen](https://reader038.vdocument.in/reader038/viewer/2022100508/55c54a5dbb61eb4e6d8b45a6/html5/thumbnails/7.jpg)
Page 7 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.
CM
SGT-300-2S Key BenefitsHigh Availability
Maintenance ProfileA-service (1 day) B-service (4 days)C-service (6 days)
> 99% availability
0 34 68 102 136
AA A
BB
AA A AA A AA A
C
OperatingHoursX 1,000
Modular Design Allows Service Flexibility
![Page 8: Sgt300 md marketing rev1-moehlen](https://reader038.vdocument.in/reader038/viewer/2022100508/55c54a5dbb61eb4e6d8b45a6/html5/thumbnails/8.jpg)
Page 8 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.
CM
SGT-300-2S Key BenefitsFuel Flexibility
Medium Calorific Value (MCV) High Calorific Value (HCV)‘’Normal’’
Wobbe Index (MJ/Nm³)
Low Calorific Value (LCV)
Pipeline Quality NG
37(86%CH4/14%N2)
49100%CH4)
Initial DLE Release Range
ExtensionHCV Fuels
ExtensionMCV Fuels
Fuel Capability Extension of standard fuel system
Planned Fuel Flexibility read across from Common Combustion Design
![Page 9: Sgt300 md marketing rev1-moehlen](https://reader038.vdocument.in/reader038/viewer/2022100508/55c54a5dbb61eb4e6d8b45a6/html5/thumbnails/9.jpg)
Page 9 March/April 2014 Energy SectorCopyright © Siemens AG 2014. All rights reserved.
CM
SGT-300 Industrial gas turbineKey benefits
High reliability (evolutionary proven technology)Competitive power rating and efficiencyApplication flexibility –Mech. driveInherent fuel flexibility and low emissionsService friendly with high availability