shaping a bright future - stryker meded
TRANSCRIPT
Shaping a bright future
Illuminated Instruments for plastic and reconstructive surgery
Restoring shape and hopeOur Illuminated Instruments enable greater visualisation, ability
and precision during breast reconstruction. The impact is equally beneficial for your patients, providing life-changing results with high satisfaction and minimal trace of surgery.
Common applications include:
+ Breast reconstruction; including immediate or delayed,biologic or implant based, and pre- or sub-pectoral
- Placement of tissue expander- Exchange of tissue expander to implant- Direct to implant- Autologous reconstruction/flaps (TRAM, DIEP)
+ Revisions, capsulectomies/exchanges
+ Augmentation/reduction procedures
Illuminated Retractor System: for broad illumination
Eikon LT + Bright, thermally-cool light
and non-conductive materialprotect against thermalhazards
+ Volumetric spread provideseven intracavity lightingwithout washing outtissue colour
+ Microlenses shape lightto reduce shadowsor backward glare
+ Ergonomic, low-profile designfor use in deep cavities orthrough small incisions
+ Elevated tip and smooth edgesenable movement andminimise pressure
+ Ultra-lightweight design
+ 45+ reusable styles
+ Compatible with commerciallyavailable light sources withACMI connection, LEDrecommended
DeaverAll the same benefits as Eikon LT plus:
+ “Question mark” shape to retract,expose and hold back tissue,muscle and organs
+ Adjustable illumination anywherealong entire retractor length
+ Used with flexible PhotonGuideAdapt illuminators
Eikon LT
Deaver
PhotonGuide and Adapt
PhotonGuide Adapt+ Adjustable illumination
anywhere along entireretractor length
+ Slide to adjust throughoutyour case
+ Can be removed and reinsertedinto other Adapt retractorsperioperatively
+ For single use with Adapt-styleretractors
PhotonGuide+ Narrow and wide styles
+ For single use with Eikon LT
retractors
Energy options: for soft tissue dissection
Multi-tasking aspirator: enhances efficiency
PhotonSaber Y+ Aspirates fluid, retracts soft tissue, evacuates smoke and provides
bright, thermally-cool illumination
+ Low-profile design for use in deep cavities or through small incisions
+ Metal and bulb tip styles, as well as standard or pistol grip
SafeAir electrosurgical smoke pencil
SafeAir electrosurgical smoke pencil+ CUT/COAG for less challenging cases
(simple/radical mastectomy, simplelumpectomy)
+ “On-tip” integrated smoke evacuation
+ Compatible with commerciallyavailable monopolar ESUs
Reconstruct what’s possible
+ Access any quadrant ofthe breast through remoteincisions
+ See clearly in deep spaces suchas breast, axillary, or pectoralcavities containing messy orunknown challenges
+ Differentiate tissue planesto harvest flap with greaterprecision, efficiency and safety
“Being modifiable makes it better. I can adjust the light to exactly where I need it depending on the depth of my dissection. Sometimes the light is too close to the tissue with a tebbetts retractor and can wash out the tissue, which affects the quality of my visualisation. I chose to use the Eikon line because the retractor is designed for breast procedures and is gentle on the tissue due to the rounded shape and smooth edges.”
Will Schleicher, MDPlastic and Reconstructive SurgeryUniversity Hospitals, Cleveland
“The technology enables me to control bleeding by identifying perforators on the chest wall and accurately cauterise these vessels under direct visualisation.”
Abhishek Chatterjee, MD, MBA Chief, Division of Plastic Surgery Tufts Medical Center
+ Assess flap thickness via trans-illumination to help gauge flapand nipple integrity
+ Reduce risk of skin or nipplenecrosis due to low thermalspread and high precision
+ Work gently on radiated tissue
+ Spot bleeders that can lead topost-op hematoma or re-operation
+ Using advanced energy andlower settings, work around thepectoralis muscle with reducedpotential for muscle activation
+ See surgical sponges or otheritems that could result inretained objects
+ In many cases, use single-incision approaches to performcomplex procedures
+ Reduce cost and logisticalstress associated withproprietary equipment
+ Work more comfortably,without head lights or constantadjustments to overhead lights
Your complete solution To demo or learn more about our
Illuminated Instruments and Hidden
Scar breast reconstruction program
call your Surgical Technologies sales
representative, customer service at
+61 29467 1000 or visit
www.strykermeded.com.
Surgical Technologies
A25D 25mmx 133mm
A38D 38mmx 134mm
Eikon LT illuminated retractors (without teeth) Heane s le
C40XN 40mm x 12mm, extra narrow
C40N 40mm x 20mm, narrow
C50 50mmx30mm
C90N 90mm x 20mm, narrow
C90 90mmx30mm
C90W 90mm x 60mm, wide
Cl35N 135mm x 20mm, narrow
Cl35 135mm x 30mm
Cl35W 135mm x 60mm, wide
Cl35SH 135mm x 60mm, sweetheart
Cl75 175mm x 30mm
Eikon LT illuminated retractors (with teeth) Heaney style
C50T 50mmx30mm
C90NT 90mm x 20mm, narrow
C90T 90mmx30mm
C90WT 90mm x 60mm, wide
Cl35NT 135mm x 20mm, narrow
Cl35T 135mm x 30mm
Cl35WT 135mm x 60mm, wide
Cl75T 175mm x 30mm
Stryker or its affiliated entities own, use, or have applied for the following trademarks or service marks: Eikon, Hidden Scar, Intelligent Photonics, PhotonBlade, PhotonGuide, PhotonSaber, Stryker and Visionary Surgery. All other trademarks are trademarks of their respective owners or holders.
The absence of a product, feature, or service name, or logo from this list does not constitute a waiver of Stryker's trademark or other intellectual property rights concerning that name or logo.
A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery.
D0000015933 Rev. AA SSP G55/PS Copyright © 2019 Stryker
stryker
104008 Narrow
104015 Wide
PGA! Adapt
PhotonSaber Y (Yankauer style) sterile, single use device; includes optional pistol grip
ES!Y Bulb tip
ES3Y Taper tip
ES4Y Metal tip
Retractor accessories
FC!S
FC!SP
FC!B
ST2B
ST!C
Single fiber optic cable, blue; 10ft, ACM!
Single fiber optic cable, pink; !0ft,ACMI
Bifurcated fiber optic cable; 11. 5 ft, ACMI
Two-level sterilisation
tra ; 14in x !0in x 5.2in
Light Box
Retractors and associated slats are non-sterile,
reuasable instruments. Slats are not interchangeable.
Each retractor includes 2 reusable slats.
• Non -sterile options for procedure p acks available through distributors
Stryker Australia Pty Ltd
8 Herbert Street, St Leonards NSW 2065 T: 61 2 9467 l000 F: 61 2 9467 l010
Stryker New Zealand Ltd 515 Mt Wellington Highway, Mt Wellington Auckland T: 64 9 573 1890 F: 64 9 573 1891
For more information contact your local Stryker Sales
Representative
www .strykermeded.com
I. Bennett, H. et al. "Energy-based Tre atment of Tissue and Assessment IX.• SPIE Journal (2017): 10066
2. Ryan, E . et al. ·comp arison of Later al Penetr ating Therm al Tissue Injury Associ ated with the PhotonBlade and Plasm aBlade 3.0S." Invuity
INVLLS2000HPAK LED Turbo Light Source