ShelterPro Chimney Systems
VENTING SOLUTIONS BUILT BETTER
Class A Chimney . . . . . . . . .2
Pellet Pipe . . . . . . . . . . . . . 14
Liner Systems . . . . . . . . . . .11
Installation Guide . . . . . . . . . . 9
Made in uSA & Canada
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-70762
ShelterPro Chimney SystemsShelterPro off ers the perfect solution for multiple venting needs. All parts are manufactured with the best materials available and are made in the USA and Canada. Whether you are venting a wood stove, pellet stove or lining a masonry chimney, you will fi nd practical and profi table solutions in the ShelterPro family of products.
ShelterPro incorporates the latest technology in factory-built chimney design; utilizing 304 stainless for the inside liner and the outside casing, providing superior performance, durability and safety. ShelterPro is designed to ser-vice today’s appliances, which are engineered to produce low emissions and high heat. ShelterPro is the choice of professionals who are looking for a better quality, factory-built chimney system.
ShelterPro is Safety Tested and Listed to applicable UL/ULC Standards, including:USA:UL103-HT Safety Standards for chimney serving solid fuel and liquid fuel appliances. This chimney system has been designed for use with wood stoves, fi replaces and residential furnaces.Allowable Flue Gas Temperatures are:Maximum Continuous 1000° F / 540° CBrief Forced Firing 1400° F / 760° C (60 min.)Creosote Burn Out 2100° F / 1150° C (3 x 10 min.)
The ShelterPro Smart Choice Lifetime Warranty applies to all Chimney components (not just insulated lengths) making a ShelterPro Chimney the smart choice every time (see written warranty for details).
Premium Grade 304 Stainless Steel construction of both the inner liner and the outer casing make ShelterPro extremely corrosion resistant. Embossed couplers do not allow moisture to penetrate the chimney’s outer wall. Sections simply ‘twist-lock’ together and may be secured with optional Lock-ing Bands. The ShelterPro product line features Deluxe Chimney Support Components that will enhance any installation.
enhanced featurescertifi cations & applications
smart choice lifetime warrantyAll ShelterPro Supports are designed to carry four times the combined weight of each system of maxi-mum allowable height.
supports/framing
Support and Framing Dimensions TableCeiling Support Wall Support Cathedral
Ceiling SupportRoof Support
Support 50’ 38’ 38’ 50’
Diameter Framing Dimensions
6” Dia 12-3/8” x 12-3/8” 14-3/8” x 14-3/8” 12” x 12” N/A
8” Dia 14-3/8” x 14-3/8” 14-3/8” x 14-3/8” 14” x 14” N/A
ShelterPro Class A Chimney
ShelterPro is Safety Tested and Listed to applicable
USA:UL103-HT Safety Standards for chimney serving solid fuel and liquid fuel appliances. This chimney system has been designed for use with wood stoves,
ShelterPro is Safety Tested and Listed to applicable UL/ULC Standards, including:USA:UL103-HT Safety Standards for chimney serving solid fuel and liquid fuel appliances. This chimney system has been designed for use with wood stoves, fi replaces and residential furnaces.Allowable Flue Gas Temperatures are:Maximum Continuous 1000° F / 540° CBrief Forced Firing 1400° F / 760° C (60 min.)Creosote Burn Out 2100° F / 1150° C (3 x 10 min.)
certifi cations & applications
UL/ULC Standards, including:USA:UL103-HT Safety Standards for chimney serving solid fuel and liquid fuel appliances. This chimney system has been designed for use with wood stoves, fi replaces and residential furnaces.Allowable Flue Gas Temperatures are:Maximum Continuous 1000° F / 540° CBrief Forced Firing 1400° F / 760° C (60 min.)Creosote Burn Out 2100° F / 1150° C (3 x 10 min.)
The ShelterPro Smart Choice Lifetime Warranty applies to all Chimney components (not just insulated lengths) making a ShelterPro Chimney the smart choice every time (see written warranty for details).
smart choice lifetime warranty
ShelterPro incorporates the latest technology in factory-built chimney design; utilizing 304 stainless for the inside liner and the outside casing, providing superior performance, durability and safety. ShelterPro is designed to ser-vice today’s appliances, which are engineered to produce low emissions and high heat. ShelterPro is the choice of
ShelterPro incorporates the latest technology in factory-built chimney design; utilizing 304 stainless for the inside liner and the outside casing, providing superior performance, durability and safety. ShelterPro is designed to ser-vice today’s appliances, which are engineered to produce low emissions and high heat. ShelterPro is the choice of professionals who are looking for a better quality, factory-built chimney system.
ShelterPro is Safety Tested and Listed to applicable UL/ULC Standards, including:USA:UL103-HT Safety Standards for chimney serving solid fuel and liquid fuel appliances. This chimney system has been designed for use with wood stoves,
certifi cations & applications
ShelterPro Class A Chimney
ShelterPro incorporates the latest technology in factory-built chimney design; utilizing 304 stainless for the inside liner and the outside casing, providing superior performance, durability and safety. ShelterPro is designed to ser-vice today’s appliances, which are engineered to produce low emissions and high heat. ShelterPro is the choice of professionals who are looking for a better quality, factory-built chimney system.
smart choice lifetime warranty
ShelterPro incorporates the latest technology in factory-built chimney design; utilizing 304 stainless for the inside liner and the outside casing, providing superior performance, durability and safety. ShelterPro is designed to ser-vice today’s appliances, which are engineered to produce low emissions and high heat. ShelterPro is the choice of professionals who are looking for a better quality, factory-built chimney system.
solid fuel and liquid fuel appliances. This chimney system has been designed for use with wood stoves, fi replaces and residential furnaces.Allowable Flue Gas Temperatures are:Maximum Continuous 1000° F / 540° CBrief Forced Firing 1400° F / 760° C (60 min.)Creosote Burn Out 2100° F / 1150° C (3 x 10 min.)
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-7076 3
All ShelterPro Twist-Lock Couplers are embossed (not lanced) and seams are weather-proofed to prevent moisture from entering the chimney. In addition, the 1” space between the inner/outer walls is solid packed with Mineral Wool Fiber insulation to provide superior insulating qualities, in a “slim-line” design. Solid pack design performs favorably to blanket type and air-cooled designs.
Construction
Embossed CouplerPrevents moisturepenetration
“Solid Pack” InsulationAugured in place for better insulating value (than blanket insulation) to keep outside temperatures low - for safety and inside temperatures high - for per-formance
Premium Grade 304 Stainless Steel Inner LinerHigh grade material heats up quickly to enhance draft
Premium Fiber Insulation100% Mineral Wool(No Chlorides)
Twist-LockConnectionEasy Assembly
Premium Grade 304 Stainless Steel Outer CasingMaterial prevents corrosion
The chimney must extend at least three feet above the highest point where it passes through the roof surface (not including the cap) and at least two feet higher than any part of the building within a horizontal distance of ten feet.
height requirements
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-70764
ShelterPro Chimney includes a LIFETIME WARRANTY
Stainless Steel Chimney
Chimney Pipe: available in both 6” and 8” diameters and in the following lengthsPart Number Description Length in inches
SHP*L6 SS Class “A” Chimney 6
SHP*L12 SS Class “A” Chimney 12
SHP*L18 SS Class “A” Chimney 18
SHP*L24 SS Class “A” Chimney 24
SHP*L36 SS Class “A” Chimney 36
Insulated TeePart Number Description
SHP*ITP Insulated Tee with Cap
SHP*ITPI Insulated Tee Cap Only
Locking BandPart Number Description
SHP*SLB Includes nut and bolt, 7/16” wide
* Both 6” and 8” available. Insert 6 or 8 for the part number.
ShelterPro Class A Chimney
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-7076 5
Supports and Adaptors
ShelterPro Chimney includes a LIFETIME WARRANTY
Decorator Ceiling SupportPart Number Description
SHP*CSB Sold as part of a kit only, see SHP*CSK on page 8
Cathedral Ceiling SupportPart Number Description
SHP*CCSB Sold as part of a kit only, see SHP*CCSK on page 8
Adjustable Wall SupportPart Number Description
SHP*AWS Supports up to 38’ of chimney
Roof SupportPart Number Description
SHP*RS Adjusts to any pitch, supports up to 50’ of chimney
Roof GuyPart Number Description
SHP*URK Universal, fits any diameter
Adaptor PlatePart Number Description
SHP*AP To be used with specifically listed factory built fireplaces
Stainless Wall BandPart Number Description
SHP*WB Maintains the mandatory clearance to combustibles
Black Stove Pipe AdaptorPart Number Description
SHP*ASE For an easy transition from black stove pipe to factory built chimney
ShelterPro Class A Chimney
* Both 6” and 8” available. Insert 6 or 8 for the part number.
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-70766
ShelterPro Chimney includes a LIFETIME WARRANTY
Flashings and Rain Caps
Galvalume Flashing Part Number Description
SHP*AAF Adjustable 1/12 to 6/12, includes storm collar
SHP*AF Adjustable 6/12 to 12/12, includes storm collar
SHP*ATC 6” Flat, includes storm collar
Dead Soft Aluminum Base Flashing Part Number Description
SHP*TDSF For corrugated metal roofs, includes storm collar
Galvalume Storm Collar Part Number Description
SHP5*ASC-1 Installed above roof flashing
Deluxe Stainless Steel Rain Cap Part Number Description
SHP*DRC Premium quality stainless steel, twist-lock connection
Spark Arrestor Part Number Description
SHP*SPAR Stainless steel mesh, fits inside Deluxe Rain Cap
ShelterPro Class A Chimney
* Both 6” and 8” available. Insert 6 or 8 for the part number.
SHP*ATC
SHP*AF
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-7076 7
Supports and Adaptors
ShelterPro Chimney includes a LIFETIME WARRANTY
Black Wall Thimble Part Number Description
SHP*WTB Black matte finish with brass trim
Attic Insulation ShieldPart Number Description
SHP*AIS Designed to keep insulation away from chimney, and to maintain the mandatory 2” clearance to combustibles
Firestop Radiation Shield Part Number Description
SHP*FRC Also known as Firestop Joist Shield; maintains mandatory 2” clearance to combustibles
Rafter Radiation ShieldPart Number Description
SHP*RRS The RRS must be installed where the chimney is enclosed immediately below the roof line
Galvalume Fire Stop Part Number Description
SHP*FP Also known as a finishing plate
ShelterPro Class A Chimney
* Both 6” and 8” available. Insert 6 or 8 for the part number.
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-70768
ShelterPro Chimney includes a LIFETIME WARRANTY
Ceiling, Wall and Elbow Kits
ShelterPro Class A Chimney
Standard Ceiling Support KitPart Number Description
SHP*CSK Includes 1 each - Deluxe Ceiling Support; Deluxe Rain Cap; Stove Pipe to Chimney Adaptor; Attic Insulation Shield
Cathedral Ceiling Support KitPart Number Description
SHP*CCSK Includes 1 each - Cathedral Ceiling Support;Stove Pipe to Chimney Adaptor; Deluxe Rain Cap
Wall Support KitPart Number Description
SHP*WSK Includes 1 each- Wall Support Bracket; Stove Pipe to Chimney Adaptor; Wall Thimble; Deluxe Rain Cap; Insulated Tee; Locking Band; and 2 Wall Bands
Elbow KitPart Number Description
SHP*15ELK 15° Kit; Includes 2 Elbows; 1 Elbow Support; 4 Locking Bands
SHP*30ELK 30° Kit; Includes 2 Elbows; 1 Elbow Support; 4 Locking Bands
* Both 6” and 8” available. Insert 6 or 8 for the part number.
SHP*30ELK
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-7076 9
Installation
ShelterPro Class A Chimney
1 Before you begin, determine the inside diameter of your chimney. This is usually the same size (6” or 8”) as the flue collar on your wood stove or furnace.
2 Select type of installation by determining where your chimney will run. See illustrations of different installation types below.
STANDARD CEILING SUPPORT INSTALLATIONS
WALL SUPPORT INSTALLATIONS CEILING SUPPORT
One Story Two Story Elbow Installation
One Story Through a Soffit With Cathedral Ceiling Support Box
Deluxe Rain Cap
Chimney Sections
Storm Collar
Adjustable RoofFlashing
Stove Pipe Adaptor
Firestop/AtticInsulation Shield
Decorator Ceiling Support
Double WallStove Pipe
Deluxe Rain Cap
Chimney Sections
Storm Collar
Adjustable RoofFlashing
Chimney Sections
Stove Pipe Adaptor
Firestop/AtticInsulation Shield
Decorator Ceiling Support
Double WallStove Pipe
Chimney must be enclosed in living space
Deluxe Rain Cap
Chimney Sections
Storm Collar
Adjustable RoofFlashing
Stove Pipe Adaptor Decorator Ceiling
Support
Double WallStove Pipe
Firestop/AtticInsulation Shield
Stainless SteelElbow
Deluxe Rain Cap
Deluxe Rain Cap
Chimney Sections
Wall Band
Wall Thimble
Stainless SteelTee
Adjustable WallSupport
12” Length orInsulated Tee Plug
Stove Pipe Adaptor
Double WallStove Pipe
Stainless SteelTee
Adjustable WallSupport
12” Length orInsulated Tee Plug
Wall Thimble
Stove Pipe Adaptor
Adjustable RoofFlashing
Wall Band
Storm Collar
Deluxe Rain Cap
Chimney Sections
Storm Collar
Adjustable RoofFlashing
Stove Pipe Adaptor
CathedralCeiling Support
Double WallStove Pipe
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-707610
Installation
ShelterPro Class A Chimney
Min. 3 ft.
Attic Insulation Shield
Firestop Radiation Shield (Joist Shield) must be installed when the chimney passes from a lower living space into an upper living space.Note: You must enclose all sections of the chimney when it passes through accessible living areas. ShelterPro chimney requires ONLY 2” of clearance to combustibles.
A minimum of 9” clearance from the Ceiling/Wall is required when using Double Wall Black Stove Pipe or 18” Single Wall Stove Pipe.
If the Chimney extends 5 feet or more above the roof, you must install a Universal Roof Guy Kit.
Install first Wall Band 3 feet above Wall Support, and add one Wall Band every 8 feet there after.
Tee requires a chimney length to go through the wall, and it must extend a minimum of 3” into the room.
3 Determine the number of Chimney lengths required. ShelterPro Chimney lengths are avail-
able in 36”, 24”, 18”, 12”, and 6” lengths. The chimney must extend at least 3 feet above the highest point where it passes through the roof surface and at least 2 feet higher than any part of the building within a horizontal distance of 10 feet.
NOTE: When calcu-lating the installed length of your chimney subtract 11/8” for each joint and include the height require-ments as shown in this illustration.
HEIGHT REQUIREMENTS
3’ min. 10’2’
2’3’ min.
4 Choose the proper Roof Flashing required for your installation.
To determine which Roof Flashing you require, work out the pitch of your roof.0/12 - 6/12 Roof Pitch = SHP*AAF (Low Slope)6/12 - 12/12 Roof Pitch = SHP*AF2 (Steep Slope)NOTE - for Metal Roofs use:Dead Soft Aluminum Base Flashing - SHP*TDSF
To calculate your roof pitch use two 12” rulers to mea-sure the number of inches (A) from the end of the other ruler down to the roof.
ROOF FLASHING SELECTION CHART
(A)
For example, if (A) equals 3”, then the roof pitch is 3/12.
5 Calculate the offset for Ceil-ing Support Installations.
If an offset is required to avoid rafters or other obstructions, measure the horizontal distance required and the vertical height available. Then refer to the Chimney Offset Chart in order to determine which Elbows and Chimney Lengths are required.
A: Offset
B: Height
CHIMNEY OFFSET CHART
6" Diameter 8" Diameter
2 x 15° no chimney length
2 x 15°2 x 15°
2 x 15°2 x 15°
6" chimney length12" chimney length
24" chimney length36" chimney length
2 x 30°2 x 30°
2 x 30°
2 x 30°
2 x 30°
1 1 " 10 "
2 " 14 15 "4" 20 21"
7" 32" 7" 32 "10 " 43 " 10 " 44 "
no chimney length6" chimney length
12" chimney length
24" chimney length
36" chimney length
2 " 11 " 14 "
21"
6"
9"
15"
21"
24"
5 "
8 "14 "
20 "
15 " 18 "
31 " 32 "
41 " 44 "
Elbow Chimney Lengths A B A B10”
2 1/2”4”
" 3
* Both 6” and 8” available. Insert 6 or 8 for the part number.
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-7076 11
ShelterPro Liner is made from 316L stainless steel and is designed to reline existing chimneys or to be used in new construction. ShelterPro liner is manufactured from the highest grade mill certifi ed stainless steel alloy. It is made from continuous strip of 7-ply stainless steel that is interlocked and crimped to produce a gas and watertight lining system of superior strength and durability. Its corrugated construction allows for expansion and contraction during heat up and cool down periods, removing any stress on the system.
ShelterPro Liner
ShelterPro Liner
• ShelterPro Liner is .006” thick steel, the industry standard.• It has a lifetime transferrable warranty that is valid if properly maintained by a chimney professional.• ShelterPro Liner is listed by Underwriters Laboratories to UL1777, UL64, UL441 standards for insulation. It is an all-fuel liner and can be used for wood, coal, oil, corn, and gas appliances.
Features
ShelterPro Universal Liner Kits
ShelterPro Universal Kits come with installation instructions and a lifetime warranty. This kit has been installed in venting applications since 1992 and continues to be the most popular “all fuels” kit being off ered. Other sizes are available including 3”-8” inside diameter (ID) in our .006” (CB) liners.
• Top kit which includes a rain cap, storm collar, top clamp and a 13”x13” top plate
• Two part tee with removable 10” length take off (snout) made of 316 stainless
• Tee end cap 316 stainless• Stove adaptor• Every job is unique,
therefore if you need a larger plate size top kit,
add $5 to the cost of the kit and specify when ordering.
• All universal tees have a snout length of 10”, if you need an extended snout for your tee, specify when ordering. For all fuel applications, call Customer Service with questions.
The ShelterPro uNIVERSAL Liner Kit Includes:
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-707612
ShelterPro Liner
3” 4” 5” 5.5” 6” 7” 8”
20’ NCCB320UK NCCB420UK NCCB520UK NCCB5520UK NCCB620UK NCCB720UK NCCB820UK 25’ NCCB325UK NCCB425UK NCCB525UK NCCB5525UK NCCB625UK NCCB725UK NCCB825UK 30’ NCCB330UK NCCB430UK NCCB530UK NCCB5530UK NCCB630UK NCCB730UK NCCB830U
35’ NCCB335UK NCCB435UK NCCB535UK NCCB5535UK NCCB635UK NCCB735UK NCCB835UK
40’ NCCB340UK NCCB440UK NCCB540UK NCCB5540UK NCCB640UK NCCB740UK NCCB840UK
45’ NCCB345UK NCCB445UK NCCB545UK NCCB5545KUK NCCB645UK NCCB745UK NCCB845UK
50’ NCCB350UK NCCB450UK NCCB550UK NCCB5550UK NCCB650UK NCCB750UK NCCB850UK
M A N u F A C T u R E D W I T h . 0 0 6 ” :
ShelterPro Universal Liner Kits
ShelterPro’s 2 ply 3003 Aluminum Liner can be used to vent Category 1 gas appliances with A.F.U.E. of 83% or lower.
In many cases, especially when only water heaters are vented into masonry flues, the gas appliances are vented into oversized flues. This practice may cause serious condensation and performance problems. By relining the chimney with ShelterPro Aluminum Liner you can reduce the condensation problem and improve the performance of the appliances.
Features
ShelterPro Aluminum Liner
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-7076 13
ShelterPro Liner
ShelterPro Aluminum Liner Kits
Each aluminum kit includes:• UL listed and tested 2 ply aluminum liner• Aluminum mortar collar for slipping the liner through the
thimble• Aluminum top plate with a 16”x 16” plate and a 2” high
collar around the hole diameter• Aluminum cap, and installation instructions
All ShelterPro Aluminum Liner Kits come with a 15 year warranty and are UL listed to UL441.
3” 4” 5” 5.5” 6” 7” 8”
10’ NCDB310EXT NCDB410EXT NCDB510EXT NCDB5510EXT NCDB610EXT NCDB710EXT NCDB810EXT Extension 25’ NCDB325KIT NCDB425KIT NCDB525KIT NCDB5525KIT NCDB625KIT NCDB725KIT NCDB825KIT 30’ NCDB330KIT NCDB430KIT NCDB530KIT NCDB5530KIT NCDB630KIT NCDB730KIT NCDB830KIT 35’ NCDB335KIT NCDB435KIT NCDB535KIT NCDB5535KIT NCDB635KIT NCDB735KIT NCDB835KIT 50’ NCDB350KIT NCDB450KIT NCDB550KIT NCDB5550KIT NCDB650KIT NCDB750KIT NCDB850KIT
3” 4” 5” 5.5” 6” 7” 8” 10’ NCDB310EXT NCDB410EXT NCDB510EXT NCDB5510EXT NCDB610EXT NCDB710EXT NCDB810EXT Extension
25’ NCDB325 NCDB425 NCDB525 NCDB5525 NCDB625 NCDB725 NCDB825 30’ NCDB330 NCDB430 NCDB530 NCDB5530 NCDB630 NCDB730 NCDB830 35’ NCDB335 NCDB435 NCDB535 NCDB5535 NCDB635 NCDB735 NCDB835 50’ NCDB350 NCDB450 NCDB550 NCDB5550 NCDB650 NCDB750 NCDB850
ShelterPro Aluminum Liner
M A N u F A C T u R E D W I T h . 0 0 6 ” :
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-707614
ShelterPro Pellet Pipe
• Available in 3” and 4” diameters• Full line of fittings and full range of pipe
lengths increase installation flexibility• Proven coupling joint connects in seconds
to assure joint integrity• Gasketed joint design• Painted pipe lengths available for interior
use• Double wall design with 1/4” airspace
• Inner wall 304 stainless steel, outer wall paintable galvanized steel
• Rolled-over male end eliminates sharp edges
• 1” clearance to combustibles• Removable tee cap for inspection and
cleaning• Internal spacing bead assures uniform
insulating airspace between pipe walls
ShelterPro gives you the safe, effi cient, and cost-eff ective venting system that’s engineered precisely for pellet burning stoves. Model VP Pellet Pipe has been tested and listed by Underwriters’ Laboratories, Inc., in accordance with UL-641 Standard for Low Temperature Venting Systems, as well as the applicable requirements from UL-103 Standard for Residential Type and Building Heating Appliance Chimneys. VP Pellet Pipe, when installed according to ShelterPro’s installation instructions, complies with National Safety Standards, such as NFPA 211. The system is rated for fl ue temperatures up to 570°F.
ShelterPro Pellet Pipe
Pellet Pipe Lengths: available in both 3” and 4” diameters and in the following lengthsPart Number Description Length in inches
*VP-12 12” Pellet Stove Pipe 12
*VP-24 24” Pellet Stove Pipe 24
*VP-36 36” Pellet Stove Pipe 36
*VP-EZADJ12 Adj. Pellet Stove Pipe adj
Pellet Pipe Tee Part Number Description
*VP-TSB Insulated Tee with Cap - Black
VP VP-EZADJ
* Both 3” and 4” available. Insert 3 or 4 in place of * for the part number.
Elbow Part Number Description
*VP-45EL 45° Elbow, factory sealed at couplers to prevent leakage
*VP-90EL 90° Elbow, factory sealed at couplers to prevent leakage
45° 90°
10950 Linpage Place, Saint Louis, MO 63132 • 800-325-7076 15
ShelterPro Pellet Pipe
Wall Bracket/SupportPart Number Description
*VP-WB Maintains clearance to combustibles
Storm CollarPart Number Description
*VP-SC Seal inner edge with hi-temp silicone sealant
Vertical TerminationPart Number Description
*VP-VC Vent termination for through-the-roof installations
horizontal TerminationPart Number Description
*VP-HC Vent termination for through-the-wall installations
Adjustable FlashingPart Number Description
*VP-AF Used to waterproof installations that penetrate the roof line
Wall ThimblePart Number Description
*VP-WT Maintains airspace clearance
3” to 4” IncreaserPart Number Description
3VP-I4 Used to adapt 3” pipe to 4” pipe
Pipe ConnectorPart Number Description
*VP-PC To connect pipes
Multi-Fit ConnectorPart Number Description
*VP-APC Connects 3” flue collar to 4” VP parts
Vacuum Cleanout CapPart Number Description
*VP-VCC Eliminates need to remove tee cap to clean pipe
hy-C.COM