shorter bunch length in atf dr and x band extraction circuit

10
Shorter bunch length in ATF DR and X band extraction circuit Vladimir Vogel KEK March 7, 2005 ATF2 meeting

Upload: devaki

Post on 05-Jan-2016

35 views

Category:

Documents


0 download

DESCRIPTION

Shorter bunch length in ATF DR and X band extraction circuit. Vladimir Vogel KEK March 7, 2005 ATF2 meeting. Accelerate voltage. Accelerate phase. 714 MHz. 714 MHz. Harmonic number. Present Bunch length. C band, 8mm-4mm. Start. F.J. Decker, and all. C band. L =1 m, P = 4 kW - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Shorter bunch length in ATF DR and X band extraction circuit

Shorter bunch length in ATF DR and X band extraction circuit

Vladimir VogelKEK

March 7, 2005ATF2 meeting

Page 2: Shorter bunch length in ATF DR and X band extraction circuit

714 MHz 714 MHz

Wave length (mm)0 5 10 15 20 25

-1.5

-1.0

-0.5

0.0

0.5

1.0

1.5

C band

20 0

0

0

*cos( )* ( ) 1

UUadd

N

U

N

Accelerate voltageAccelerate phase

Harmonic number

Present Bunch length

Start

Length (mm)

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110

Eef

f (k

V)

0

40

80

120

160

200

240

280

320

360

400

C band, 8mm-4mm

F.J. Decker, and all.

Page 3: Shorter bunch length in ATF DR and X band extraction circuit
Page 4: Shorter bunch length in ATF DR and X band extraction circuit
Page 5: Shorter bunch length in ATF DR and X band extraction circuit

*2* *shE R P

L =1 m, P = 4 kWU = 167 kV

Single cell cavityFor 150kV, P=60 kW !

Page 6: Shorter bunch length in ATF DR and X band extraction circuit

714 MHz 714 MHzWave length (mm)

0 5 10 15 20 25-1.5

-1.0

-0.5

0.0

0.5

1.0

1.5

C band P=4kW

Length (mm)

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110

Eef

f (k

V)

0

40

80

120

160

200

240

280

320

360

400

C + X band4mm-2mm

X band P=1kW

Page 7: Shorter bunch length in ATF DR and X band extraction circuit

X band 60 MW, 20nSec

Load

714 MHz

11.2 nSec

20 nSec RF11424MHz

714 MHz

Wave length (mm)0 5 10 15 20 25

-1.5

-1.0

-0.5

0.0

0.5

1.0

1.5

C band 8mm-4mm, 4kW - CW

Septum, or small voltage kicker

X band 4mm-2mm, 1kW CW

dE=1%

4 SET’s

Page 8: Shorter bunch length in ATF DR and X band extraction circuit

August 31, 2004

PPM#4a, U = 500kV, Tp= 30, 40, 100 nSec, Pin=-17dbm, -6dbm

Frequency (MHz) -11000MHz

320 340 360 380 400 420 440 460 480 500 520 540

Pou

t L1

, L2

0

50

100

150

200

250

300

350

L1 (Pin -17dbm) 40 nSec L2 (Pin -17dbm) 40nSec L1 (Pin -6dbm) 30 nSec L2 (Pin -6dbm) 30nSec L1 (Pin -8dbm) 100hSec L1 (Pin -8dbm) 100nSec (L1+L2)/2

Page 9: Shorter bunch length in ATF DR and X band extraction circuit

PPM#4A, F = 11424MHz, Pout ~ 30 MW

Time (Sec)

-1.0e-8 -5.0e-9 0.0 5.0e-9 1.0e-8 1.5e-8 2.0e-8 2.5e-8 3.0e-8 3.5e-8 4.0e-8

Pin

, Pou

t (V

)

-0.4

-0.3

-0.2

-0.1

0.0

PinPout L2Pout L1

Page 10: Shorter bunch length in ATF DR and X band extraction circuit

bunch spacing in DR = 11.2 (5.6) nS, DR circumference 4.76 (2.38) km

• Structure 4* L=0.4 m, Vgr~0.2, a/~ 0.3, E ~16 Mev

• Klystrons number 4 , pulse length ~ 100 nSec, Pout ~15 MW

• Repetition rate 2.65/4 MHz, (with delay lines), Pav.=4*15kW

• IGBT modulator for 4 klystrons, 270kV, 4*112A

• DR one turn time ~ 15.8 S, dam. ~ 25 mS, Ndr = 1580, (LC X-band N = ~12 000)