8
NEW Sigma Series Multi-screen polymeric, self-cleaning filter combining Amiad’s suction-scanning screen technology with an innovative compact design 4” 6” 8” flowrate 132-528 gpm (30-120 m 3 /h) 220-792 gpm (50-180 m 3 /h) (220-1,233 gpm (50-280 m 3 /h) inlet/outlet diameter 4” (100 mm) 6” (150 mm) 8” (200 mm) filtration degrees 80-300 micron min. operating pressure during flush cycle 22 psi/1.5 bar (electrical controller) 32 psi/2.2 bar (hydraulic controller) max. working pressure 145 psi (10 bar) Highlights: * Patent pending Compact design and small footprint Easy installation and maintenance Diverse open-field irrigation, landscaping, greenhouse and aquaculture applications AC/DC electronic controller (optional) Increased reliability and durability Suction-scanning screen technology Large filtration area Polymeric housing - Corrosion and fertilizer resistant Low water and energy consumption

Upload: lycong

Post on 22-Sep-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Sigma Series - Amiadamiad.com/landing-sigma/Sigma_Family_Letter_USA_Irig_2015.pdf · Sigma models Amiad’s Sigma Series consists of the following models: • Sigma 4” - for up-to

NEW

Sigma SeriesMulti-screen polymeric, self-cleaning filter combining Amiad’s suction-scanning screen technology with an innovative compact design

4” 6” 8”

flowrate 132-528 gpm(30-120 m3/h)

220-792 gpm(50-180 m3/h)

(220-1,233 gpm(50-280 m3/h)

inlet/outlet diameter

4”(100 mm)

6”(150 mm)

8”(200 mm)

filtration degrees

80-300 micron

min. operating pressure during flush cycle

22 psi/1.5 bar (electrical controller)32 psi/2.2 bar (hydraulic controller)

max. working pressure

145 psi(10 bar)

Highlights:

* Patent pending

• Compact design and small footprint

• Easy installation and maintenance

• Diverse open-field irrigation, landscaping, greenhouse and aquaculture applications

• AC/DC electronic controller (optional)

• Increased reliability and durability

• Suction-scanning screen technology

• Large filtration area

• Polymeric housing - Corrosion and fertilizer resistant

• Low water and energy consumption

Page 2: Sigma Series - Amiadamiad.com/landing-sigma/Sigma_Family_Letter_USA_Irig_2015.pdf · Sigma models Amiad’s Sigma Series consists of the following models: • Sigma 4” - for up-to

How the Sigma Filter Works

General

The Amiad Sigma Filters are automatic filters, with multiple screens operated by a single hydraulic turbine mechanism,

with a capacity up to 1,232 gpm (280 m3/h) and from 80-300 micron filtration degree. Inlet/Outlet connections available:

4” (100 mm), 6” (150 mm), 8” (200 mm) diameter, and exhaust valve is 2” (50 mm).

The Filtration Process

Raw water enters from the filter inlet and passes through the multi-screens. Clean water flows through the filter outlet.

The gradual dirt buildup on the screen inner surface causes a filter cake to develop, with a corresponding increase

in the pressure differential across the multi-screens. A pressure differential switch (hydraulic or electric) senses the

pressure differential and when it reaches a pre-set value, the self-cleaning process begins.

The Control System

The Sigma operation and cleaning cycle is controlled and monitored by a hydraulic rinse control or an electronic battery /AC

controller. During the self-cleaning cycle the rinse control operates the exhaust valve by means of an hydraulic command,

and when the cycle is complete, it automatically closes the exhaust valve and waits for the next cycle. In the case of the

electronic controller, the self-cleaning cycle is triggered by the DP switch, then the AC or DC controller switches the

solenoid to open or close the exhaust valve by means of a hydraulic command; When cycle is complete, the controller

will shut the exhaust valve and wait for another cleaning command.

The self-cleaning cycle begins under any one of the following conditions:

1. Receiving a signal from the Pressure Differential Device - which is preset at 0.5 bar.

2. Time interval parameter set at the controller (electronic controller only).

3. Manual Start, triggered by 3 way ball valve or via electronic controller keypad.

The electronic controller also provides:

• Flush cycles counter

• Alerts output – low battery, DP cycle

Sigma models

Amiad’s Sigma Series consists of the following models:

• Sigma 4” - for up-to 528 gpm (120 m3/h)

• Sigma 6” - for up-to 792 gpm (180 m3/h)

• Sigma 8” - for up-to 1,233 gpm (280 m3/h)

Page 3: Sigma Series - Amiadamiad.com/landing-sigma/Sigma_Family_Letter_USA_Irig_2015.pdf · Sigma models Amiad’s Sigma Series consists of the following models: • Sigma 4” - for up-to

Unique Inlet-Outlet Configurations

180000 900

Page 4: Sigma Series - Amiadamiad.com/landing-sigma/Sigma_Family_Letter_USA_Irig_2015.pdf · Sigma models Amiad’s Sigma Series consists of the following models: • Sigma 4” - for up-to

Sigma 4”

Sigma 6”

Sigma 8”

62”

(158

3)

11.5” (293)

8” (

205)

50”

(125

8)

7” (180)

26” (672)

4” OUT

4” IN

Wed

nesd

ay, J

anua

ry 21

, 201

5 9:22

:00 A

M

D

E

F

C

1 2 3 4

B

A

321 54 6 7 8

A

B

SHEET 1 OF 1

65 7 8PATH-T: \ MASTERS \M+19620SOLID\ FILTERS COMPLETE \ SIGMA \

6 SIGMA FILTER FOR CUSTOMER

SUBJECT/PROJECT:

PART NAME/TITLE:

CAT. NO:DRAWNCHECKED

APPROVED

B.O.M.

NAME DATE

ELENA 15/12/2014

Confidential property information.

DRW. NO:6'' SIGMA

ASSEMBLY DRAWING

DATE DESCRIPTION NAMEREV.

SIZE: A3Ref.

Backup Drawing:

Rev.0

C

D

E

F

SCALE: NOAmiad Water Systems Ltd.reserves the rights to make changes.

All copy rights reserved toAmiad Water Systems Ltd.

6'' SIGMA FILTER

* SUBJECTED TO CHANGESMATERIAL:

10.

7" (2

72) 6" IN

6" OUT

30.8

" (7

84)

75"

(190

5)

7" (180)

62.5

" (1

589)

26.5" (674)

10.7

" (2

72) 8" IN

8" OUT

30.9

" (7

84)

75"

(190

5)26.5" (674)

7" (180)

62.6

" (1

589)

Dim: in inch (mm)

Page 5: Sigma Series - Amiadamiad.com/landing-sigma/Sigma_Family_Letter_USA_Irig_2015.pdf · Sigma models Amiad’s Sigma Series consists of the following models: • Sigma 4” - for up-to

Head Loss Graph (in clean water)

62”

(158

3)

11.5” (293)

8” (

205)

50”

(125

8)

7” (180)

26” (672)

4” OUT

4” IN

Wed

nesd

ay, J

anua

ry 21

, 201

5 9:22

:00 A

M

D

E

F

C

1 2 3 4

B

A

321 54 6 7 8

A

B

SHEET 1 OF 1

65 7 8PATH-T: \ MASTERS \M+19620SOLID\ FILTERS COMPLETE \ SIGMA \

6 SIGMA FILTER FOR CUSTOMER

SUBJECT/PROJECT:

PART NAME/TITLE:

CAT. NO:DRAWNCHECKED

APPROVED

B.O.M.

NAME DATE

ELENA 15/12/2014

Confidential property information.

DRW. NO:6'' SIGMA

ASSEMBLY DRAWING

DATE DESCRIPTION NAMEREV.

SIZE: A3Ref.

Backup Drawing:

Rev.0

C

D

E

F

SCALE: NOAmiad Water Systems Ltd.reserves the rights to make changes.

All copy rights reserved toAmiad Water Systems Ltd.

6'' SIGMA FILTER

* SUBJECTED TO CHANGESMATERIAL:

10.

7" (2

72) 6" IN

6" OUT

30.8

" (7

84)

75"

(190

5)

7" (180)

62.5

" (1

589)

26.5" (674)

10.7

" (2

72) 8" IN

8" OUT

30.9

" (7

84)

75"

(190

5)

26.5" (674)

7" (180)

62.6

" (1

589)

0.11.4

0.02

0.080.06

0.04

0.4

0.2

0.3

0.7

0.5

0.2

2.0

psi/bar

m3/hrgpm

200

40

100

20

60

200

1000 600

60 100

400

300 10 0.01

0.45.0

3.04.0

0.11.4

0.02

0.080.06

0.04

0.4

0.2

0.3

0.7

0.5

0.2

2.0

psi/bar

m3/hrgpm

200

40

100

20

60

200

1000 600

60 100

400

300 10 0.01

0.45.0

3.04.0

0.11.4

0.02

0.080.06

0.04

0.4

0.2

0.3

0.7

0.5

0.2

2.0

psi/bar

m3/hrgpm

200

40

100

20

60

200

1000 600

60 100

400

300 10 0.01

0.45.0

3.04.0

Dim: in inch (mm)

Page 6: Sigma Series - Amiadamiad.com/landing-sigma/Sigma_Family_Letter_USA_Irig_2015.pdf · Sigma models Amiad’s Sigma Series consists of the following models: • Sigma 4” - for up-to

Sigma 4” installation of 3 units with manifold,flow up to 1,584 gpm (360 m3/h)

Sigma 6” installation of 2 units with manifold,flow up to 1,584 gpm (360 m3/h)

DRAIN

IN

OUT

OUT

DRAIN

IN

Page 7: Sigma Series - Amiadamiad.com/landing-sigma/Sigma_Family_Letter_USA_Irig_2015.pdf · Sigma models Amiad’s Sigma Series consists of the following models: • Sigma 4” - for up-to

Technical Specifications

General data Sigma 4” Sigma 6” Sigma 8”

Max. flowrate* (100µ) in average water quality 528 gpm (120 m3/h) 792 gpm (180 m3/h) 1,233 gpm (280 m3/h)

Min. operating pressure when cleaning

22 psi (1.5 bar) - Electrical controller32 psi (2.2 bar) - Hydraulic Controller

Max. operating pressure 145 psi (10 bar)

Filtration area 930 in2 (6,000 cm2) 1240 in2 (8,000 cm2) 1240 in2 (8,000 cm2)

Inlet/Outlet diameter 4" (100 mm) Flange & Victaulic 6” (150 mm) 8” (200 mm)

Weight Empty: 110 lb (75 kg) Full: 213 lb (145 kg)

Empty: 242 lb (110 kg) Full: 496 lb (225 kg)

Empty: 264 lb (120 kg) Full: 518.3 lb (235 kg)

Standard Filtration Degrees

micron 300 200 130 100 80

mm 0.3 0.2 0.13 0.1 0.08

Hydraulic control

Rinse control PP (Polypropylene), PA (Polyamide)

DP switch Built-in rinse controller set at 0.5 bar (7 psi)

Operation mode 3 way ball valve, indicate: Automatic & Manual

Optional electronic control

Control voltage 6 VDC or 24 VAC

Control power supply 4 D type 1.5V batteries / AC power

Solenoid operation data 12-9 VDC latching solenoid or 24VAC solenoid

DP switch Dry contact switch

* Amiad’s flow recommendation per water quality.

Flushing data

Exhaust valve 2" (50 mm)

Flushing time 20 sec 10 sec at 22 psi (1.5 bar)

Reject water volume per flush cycle

approx. 40-53 gallons(150-200 liters) 50 gallons (90 liters)

Construction materials

Filter housing & lid RPP (Reinforced Polypropylene) RPA (Reinforced Polyamide)

Screens Molded Weave wire 316L, screen mesh

Cleaning mechanism PBT (Polybutylene)

Exhaust valve Polymeric actuator

Seals EPDM

Control command tubing PE (Polyethylene)

Page 8: Sigma Series - Amiadamiad.com/landing-sigma/Sigma_Family_Letter_USA_Irig_2015.pdf · Sigma models Amiad’s Sigma Series consists of the following models: • Sigma 4” - for up-to

910101-000000/02.2015

W A T E R S Y S T E M S

www.amiad.com

Copyright © 2013 Amiad Water Systems Ltd. All rights reserved. The contents of this catalogue including without limitation all information and materials, images, illustrations, designs, icons, photographs, graphical presentations, designs, literary works, data, drawings, slogans, phrases, names, trademarks, tittles and any other such materials that appear in this catalogue (collectively, the “Contents”) are the sole and property of Amiad Water Systems Ltd. (“Amiad”). Amiad has sole and exclusive right, title and interest in the Contents, including any intellectual property rights, whether registered or not, and all know-how contained or embodied therein. You may not reproduce, publish, transmit, distribute, display, modify, create derivative works from, sell or participate in any sale of, or exploit in any way, in whole or in part, any of the Contents or the catalogue. Any use of the catalogue or the Contents, other than for personal use, requires the advanced written permission of Amiad.

Amiad Water Systems Ltd. D.N. Galil Elyon 1, 1233500, Israel,Tel: 972 4 690 9500, Fax: 972 4 814 1159,E-mail: [email protected]

Headquarters

Europe

Australia

Asia

America Amiad USA Inc. Main Office and Manufacturing: 120-J Talbert Road, Mooresville, NC 28117,Tel: 1 704 662 3133, Fax: 1 704 662 3155, Toll Free: 1 800 24 FILTER, E-mail: [email protected] www.amiadusa.com

West Coast Sales Office and Warehouse:2220 Celsius Avenue, Oxnard, California 93030Tel: 805 988 3323, Fax: 805 988 3313, Toll Free: 1 800 969 4055

BrazilAmiad Sistemas de Água Ltda., Av. Funchal, 411, Conj. 42, Vila Olimpia, São Paulo, CEP 04551-060Tel: +55 11 31923824, E-mail: [email protected] Oil & Gas, E-mail: [email protected]

MexicoAmiad Mexico SA DE CV, Vialidad de la Barranca 6 Piso 4Col. Ex Hacienda de Jesus del Monte. 52772. Huixquilucan (Interlomas), Edo de MexicoTel/Fax: +52 55 636 28122, E-mail: [email protected]

IndiaAmiad Filtration India Pvt Limited, 305 Sai Commercial Building, Govandi St Rd, Govandi Mumbai 400 088, Tel: 91 22-67997813/14, Fax: 91 22-67997814, Email: [email protected] China (Yixing Taixing Environtec Co., Ltd.) 70 Baihe Chang, Xingjie Yixing Jiangsu, 214204,Tel: 86 510 87134000, Fax: 86 510 87134999, E-mail: [email protected] AsiaFiltration & Control Systems Pte. Ltd., 22 Sin Ming Lane #07-88 Midview City, Singapore 573969, Tel: 65 6 337 6698, Fax: 65 6 337 8180, E-mail: [email protected]

Amiad Australia Pty Ltd. 138 Northcorp Boulevard, Broadmeadows, Victoria 3047,Tel: 61 3 93585800, Fax: 61 3 93585888, E-mail: [email protected]

Amiad Water Systems Europe SAS, Ilot No4 ZI La Boitardière, 37530 Chargé, France,Tel: 33 (0) 2 47 23 01 10, Fax: 33 (0) 2 47 23 80 67, E-mail: [email protected] Water Systems Europe SAS (Irrigation Division) 100 avenue de l’Anguillon, Z.I. des Iscles, 13160 Chateaurenard, Tel: +33 (0) 4 32 60 10 01, Fax +33 (0) 4 32 60 60 85

GermanyAmiad Water Systems SAS Europe (German branch office) Zweigniederlassung Deutschland Prinz-Regent-Str. 68 a 44795 Bochum,Tel: 49 (0) 234 588082-0, Fax: 49 (0) 234 588082-10, E-mail: [email protected] – Filtration & Treatment Systems, Istanbul yolu 26 Km, Yurt Orta Sanayii, Saray, Ankara, Tel: 90 312 8155266/7, Fax: 90 312 8155248, E-mail: [email protected]