2LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 1.0 OVERVIEW
1.00 | Contents
1.01 Introduction pg 03
2.00 Design Elements pg 04
3.00 External Signs pg 10
4.00 Internal Signs pg 33
5.00 Door Signs pg 42
6.00 Ordering Process pg 53
7.00 Technical Drawings pg 56
8.00 Annual Maintenance pg 66
3LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 1.0 INTRODUCTION
1.01 | Introduction
These guidelines have been carefully developed
to ensure that :-
a) Visitors to campus can navigate to their chosen
location quickly and efficiently.
b) Sign specifications and graphic content align
to our brand guidelines.
c) Stakeholders use this manual as a reference
guide for the procurement of new and the
refurbishment of existing signs.
Section 6 of this document outlines the best way of
procuring new signage; including sample forms for
orders of small value and contact details within the
Facilites Department.
This document will be regularly updated to reflect
changing circumstances.
4LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 2.0 DESIGN ELEMENTS
2.00 | Design Elements
The following chapter specifies visual elements
of the new sign family that comply with
Lancaster University brand guidelines and
best practice for accessability.
It includes details of correct colour, font and arrow
useage, as well as a range of internal and external
symbols to cover most requirements.
To retain a consistent identity and clear wayfinding
message it is important that no other fonts, symbols,
arrows or colours are used for signage other than
those in this document.
5LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 2.0 DESIGN ELEMENTS
2.01 | Colour Use
The colours shown opposite are to be used for
all primary sign applications. The palette takes
inspiration from the existing corporate guidelines
with accent colours specific to particular
buildings.
To promote a vibrant feel the University logo should
always sit on a white background. Wayfinding
information should be white on a dark grey or black
background which offers strong contrast.
Corporate red pms 485 should only be used as an
accent colour and to identify accessible routes.
Colour systems
The colours are specified in two finishing systems
which are appropriate to sign manufacture; either
RAL (paint) or Pantone (print).
Paint Systems
All exterior and interior signage should be painted
using two pack acrylic isocyanate thin film paint
system with a gloss lacquer finish on exterior signs
and a matt lacquer finish on interior signs. Due to
the effective and long lasting capabilities of this paint
system powder coated paint systems should not
be used. In addition, signs located in areas of
campus susceptible to vandalism should be covered
in a non-visible, anti-graffiti coating.
Primary External Colours
Corporate Colours
Primary Internal Colours
Secondary Colours
informationdark grey
informationdark grey
highlight / accessibleaccessible red
highlightcorporate red
highlight / textwhite
highlight / textwhite
highlight / textwhite
headercorporate grey
headercorporate grey
informationblack
parking / informationblue
highlight / accessibleaccessible red
warningyellow
accessible WCorange
headersilver
recyclinggreen
airman 3 nero(specifically
matched for LU)
airman 3 nero(specifically
matched for LU)
RAL 9005pms black c
pms process blue
RAL 3028pms 485
pms 1807
RAL 3028pms 485
pms 340
pms 429c
pms 429c
RAL 9006pms 877
pms process yellow pms process orange
RAL 9003white
pms 429c30% tnt
RAL 9003white
6LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 2.0 DESIGN ELEMENTS
2.02 | Font Use
To maintain the highest levels of visual
consistency, all signage uses the
typeface Frutiger Roman 55.
Frutiger is a sans serif font that is clean,
distinctive and easily legible, specifically
designed for wayfinding.
Bold and light Frutiger fonts should be
used sparingly as they reduce legibility.
No other typefaces or fonts should
be used.
An Equality Act compliant arrow to
ISO 7000 standard has been used to
accompany the Frutiger font. The arrow
should always be positioned in close
proximity to the appropriate text using
the hierarchy illustrated across the page.
Frutiger Roman 55 - body text
Frutiger Bold 65 - header text
Arrow design and hierarchy
left aligned text
right aligned text
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz1234567890
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz1234567890
1.
5.
2.
6.
3.
7.
4.
8.
7LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 2.0 DESIGN ELEMENTS
01. 02. 07.
08. 10.
CCTV
17. 18.
2.03 | Symbol Use
This page shows a range of symbols for use
with signage that have been developed to
accompany the Frutiger font. The symbols
utilise internationally recognisable
pictograms wherever possible.
Symbols should be used where possible to enhance
text content but must be positioned consistently as
detailed later in this document to maintain legibility.
01. Pedestrians
02. No pedestrians
03. Accessible Route
04. Non-accessible
05 Cycle store
06. No cycles
07. Parking
08. No parking
09. Accessible parking
10 CCTV
11. Vehicular entrance
12. Deliveries
13. Bus / Coach drop-off
14. Recycling
15. Caution
16. Information / Reception
17. Restaurant
18. Café
19. Unisex Toilets
20. Male Toilets
21. Female Toilets
22. Accessible Toilets
23. Accessible Showers
24. Showers
25. Babychange
26. Stairs
27. Lifts
28. Induction Loop
29. Public Telephone
30. First Aid
31. Weightlifting
32. Fitness Studio
33. Viewing Terrace
34. Lecture Theatre
35. Sports Viewing
36. Squash Courts
37. Swimming Pool
38. Sports Hall
39. Climbing Wall
40. Bouldering Cave
41. Sauna / Steam Room
42. Meeting Room
19.
14.
03.
09.
05.
15.
13.
16.
04. 06.
12.
20. 21.
22.
36.
26.
33.
27.
34. 35.
25.
39.
32.
23.
37. 40.
30.
24.
38. 41. 42.
31.29.
28.
11.
8LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 2.0 DESIGN ELEMENTS
2.04 | Campus Maps
A map of Lancaster University has been
designed to help direct visitors around
Campus. Map signs are located at pedestrian
hot spots in order to orientate the user
and guide them to their final destination.
There are currently two orientation artworks
developed, namely East and West.
The map includes vehicular, pedestrian, bicycle
and accessible routes. *Every building and car
park is clearly identified so that navigation is
quick and easy*.
Maps follow best practice for accessability,
reinforce the University brand and are always
orientated to the user.
quantity increased to x2 as per architect drawings
Visitor Orientation
ITEM 1_EAST_S/S_1270x1200mm
BigforthFarm
University Main Entrance
Gre
en L
ane
(no
acce
ss to
U
nive
rsit
y)
A
CB
D
E
F
HI
K
J
Lib
rary
Ave
nu
e
Bo
wla
nd
Ave
. So
uth
Farr
er A
ven
ue
Gill
ow
Ave
nu
e
Pend
le A
venu
e
Graduate East Avenue
A6 South (to M6 Junction 33)
A6 North (to Lancaster City Centre)
M6 Motorway
Lon
sdal
e So
uth
Ave
.
Car
tmel
Wes
t A
ve.
Cartmel South Ave.
Sou
th D
rive
Furn
ess
Ave
nu
e
Fyld
e A
ven
ue
Tow
er A
ven
ue
Un
der
pas
s (B
us
Sto
p)
Big
fort
h D
rive
Un
der
pas
s (B
us
Sto
p)
Ale
xan
dra
Sq
uar
e
North East Drive
Co
un
ty A
ve.
Ro
ssen
dal
e A
ve.
No
rth
Dri
ve
Cycle routeto town
Barker HouseSports Pitches
North West Drive
Bowland Ave. East
Bow
land
Ave
. Nor
th
Joh
n C
reed
Ave
.
South Spine
North Spine
Lancaster Square
South East Drive
Geo
rge
Fox
Ave
nue
Phys
ics
Ave
.
South West Drive
Alexandra Park Drive
Alexandra Park D
rive
Hazelrigg Lane
Bar
kers
Dri
ve (
A6
Sou
th E
ntr
ance
)
Gra
du
ate
Sou
th A
ve.
Alexandra Park
Gra
du
ate
Lan
e
Grass Playing PitchGrass Playing Pitch
Grass Playing PitchGrass Playing Pitch
Sports Field Car Parkports Field Car Park
Astro Turf Pitch
Grass Playing Pitch
Grass Playing PitchGrass Playing Pitch
Grass Playing Pitch
Astro Turf PitchTennis Courts
Gra
du
ate
No
rth
Ave
.
Cycle route to Ellel & Galgate
Gri
zeda
le A
ve.
G
L
11
3930
37
38
31
2823
34
32 36
55
60
61
58
63
64
65
66
67 68
52
57
54
16
2510
14 15a
15
1312
917
7
27
19
3
4
18
21
20
29
40
4149
49
24
33
45
50
47
48
41
42
8
62
59
35
6
5
44
43
51
2S
W
N
E
1
31 Alexandra Square (Shops & Banks)15 ASH House15a Islamic Prayer Room1 Bailrigg Conference Centre65 Barker House Farm6 Bigforth Farm14 Bowland Annexe28 Bowland Main & College12 Bowland Hall23 Bowland North30 Bowland Tower East37 Bowland Tower South66 Cartmel College
68 Cartmel Family housing40 Central Workshops and Stores13 CETAD24 Chaplaincy Centre54 Charles Carter 25 Conference Centre3 County Field Residences7 County Main & College18 County South20 County South Residences38 Edward Roberts Court51 Engineering Building27 Faraday Building
21 FASS Building42 Furness College41 Furness Residences47 Fylde College49 Fylde Residences55 George Fox63 Graduate College 67 Graduate Townhouses11 Great Hall57 Grizedale College58 Grizedale College Residences62 InfoLab2160 ISS Building
16 Jack Hylton Music Rooms19 John Creed Building43 Lancaster Environment Centre59 Lancaster House Hotel2 LEC Remote Workshops36 Library4 LICA Building64 Lonsdale College52 Management School45 Medical Centre10 Music Building9 Nuffield Theatre61 Pendle College
17 Peter Scott Gallery29 Physics Building48 Postgraduate Statistics Centre44 Pre-School Centre8 Round House35 Ruskin Library34 Security Lodge39 Slaidburn House (Students' Union)5 Sports Centre33 University House32 University Reception 50 Whewell Building
CCTV in operation for your personal safety and protection.
A
Principal route withwheelchair access
Key
Roads
Bus Stops
Woodland Trail
Campus buildings
Walkways
Visitor Car Parks A - L
Pay and Display Machines
Car parking for peoplewith disabilities
Water
Cycle Route
Designated BBQ Area
One Way system
A
Youare
here
EAST ORIENTATION
Maps need updating
to reflect highlighted
point
quantity increased to x2 as per architect drawings
ITEM 2_WEST_S/S_1270x1200mm
31 Alexandra Square (Shops & Banks)15 ASH House15a Islamic Prayer Room1 Bailrigg Conference Centre65 Barker House Farm6 Bigforth Farm14 Bowland Annexe28 Bowland Main & College12 Bowland Hall23 Bowland North30 Bowland Tower East37 Bowland Tower South66 Cartmel College
68 Cartmel Family housing40 Central Workshops and Stores13 CETAD24 Chaplaincy Centre54 Charles Carter 25 Conference Centre3 County Field Residences7 County Main & College18 County South20 County South Residences38 Edward Roberts Court51 Engineering Building27 Faraday Building
21 FASS Building42 Furness College41 Furness Residences47 Fylde College49 Fylde Residences55 George Fox63 Graduate College 67 Graduate Townhouses11 Great Hall57 Grizedale College58 Grizedale College Residences62 InfoLab2160 ISS Building
16 Jack Hylton Music Rooms19 John Creed Building43 Lancaster Environment Centre59 Lancaster House Hotel2 LEC Remote Workshops36 Library4 LICA Building64 Lonsdale College52 Management School45 Medical Centre10 Music Building9 Nuffield Theatre61 Pendle College
17 Peter Scott Gallery29 Physics Building48 Postgraduate Statistics Centre44 Pre-School Centre8 Round House35 Ruskin Library34 Security Lodge39 Slaidburn House (Students' Union)5 Sports Centre33 University House32 University Reception 50 Whewell Building
CCTV in operation for your personal safety and protection.
Visitor Orientation Adjacent toLICA Building
University Main Entrance
Gre
enLa
ne (n
o a
cces
s to
Uni
vers
ity)
A
CB
D
E
F
H I
K
J
Lib
rary
Ave
nu
e
Bo
wla
nd
Ave
. So
uth
Farr
er A
ven
ue
Gill
ow
Ave
nu
e
Pendle AvenueGraduate East A
venue
A6 South (to M6 Junction 33)
A6 North (to Lancaster City Centre)
M6 Motorway
Lon
sdal
e So
uth
Ave
.
Car
tmel
Wes
t A
ve.
Cartmel South Ave.
Sou
th D
rive
Furn
ess
Ave
nu
e
Fyld
e A
ven
ue
Tow
er A
ven
ue
Big
forth
Drive
Un
der
pas
s (B
us
Sto
p)
Ale
xan
dra
Sq
uar
e
North East Drive
Co
un
ty A
ve.
Ro
ssen
dal
e A
ve.
No
rth
Dri
ve
Cycle routeto town
Barker HouseSports Pitches
North West Drive
Bowland Ave. East
Bow
land
Ave
. Nor
th
Joh
n C
reed
Ave
.
South Spine
North Spine
Un
der
pas
s (B
us
Sto
p)
South East Drive
Geo
rge
Fox
Ave
nu
e
Phys
ics
Ave
.
South West Drive
Alexandra Park Drive
Alexandra Park D
rive
Hazelrigg Lane
Bar
kers
Dri
ve (
A6
Sou
th E
ntr
ance
)
Gra
du
ate
Sou
th A
ve.
Alexandra Park
Gra
du
ate
Lane
Grass Playing Pitch
Grass Playing Pitch
Grass Playing Pitch
Grass Playing Pitch
Sports Field Car Parkports Field Car Park
Astro Turf Pitch
Grass Playing Pitch
Grass Playing Pitch
Grass Playing PitchGrass Playing Pitch
Astro Turf Pitch Tennis Courts
Gra
du
ate
No
rth
Ave
.
Cycle route to Ellel & Galgate
Grizedale A
ve.
G
L
Lancaster Square
11
39 30
37
38
31
28 23
34
3236
55
60
61
58
63
64
65
66
6768
52
57
54
16
2510
1415a
15
1312
917
7
27
19
3
4
18
21
20
29
40
4149
49
24
33
45
50
47
48
41
42
8
62
59
35
6
5
44
43
51
2 S
W
N
E
1
A
Principal route withwheelchair access
Key
Roads
Bus Stops
Woodland Trail
Campus buildings
Walkways
Visitor Car Parks A - L
Pay and Display Machines
Car parking for peoplewith disabilities
Water
Cycle Route
Designated BBQ Area
One Way system
A
Youare
here
WEST ORIENTATION
*
9LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 2.0 DESIGN ELEMENTS
2.05 | Content Guidelines
a) The correct arrow hierarchy is demonstrated in fig. A
b) Standard spacing (leading) between lines of text
must always be applied (see fig. A).
c) Extended spacing must always be applied when
a change of alignment occurs (see fig. B).
d) Lines of text must always be justified left or right
dependant upon arrow direction and arranged
in alphabetical order.
e) Only list destinations that are in reasonable
proximity to the sign, in order to avoid information
overload.
f) Abreviations should not be used on directional signs.
g) Only those logos specified within this manual can be
used on external signs. Under no circumstances should
other logos be incorporated into the University’s
directional signage.
h) The height of letters must be consistently applied across
each sign type. Lines of information that extend beyond
one short line are to be avoided or only used in
exceptional circumstances.
i) The University’s signage supplier will be responsible for
policing the correct use of the University brand and the
graphic content contained on each sign.
1. Straight ahead
2. Forward & left
3. Left
4. Back & left
5. Straight ahead
6. Forward & right
7. Right
8. Back and right
fig. A fig. B
CAMPUS WATCH www.lancs.ac.uk/campuswatch
CAMPUS WATCH www.lancs.ac.uk/campuswatch
Great Hall(Nuffield Theatre & Peter Scott Gallery)
University House Reception
Visitor Car Parks A - C
Alexandra Park
Visitor Car Parks D - J
10LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
3.00 | External Signs
The following chapter details a family of external
signs that are designed to navigate users across
campus to a building entrance.
This is achieved by placing clearly visible signs with
consistent and concise messages along all major
routes across campus.
When signs are installed into soft ground the base
should be protected from cutting equipment by
a 200mm exclusion zone. The material used to
create an excluson zone should match the
surrounding landscape and be one of the following:
Waterford gravel surround, resin
bound with weed membrane
Forest bark mulch with weed
membrane
Square granite sets with weed membrane
11LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
4500 250
illuminated ‘logo and lettering’
front
rear
2700
3.01 | Main Entrance Sign EX1
The main campus entrance is identified by a
large branded monolith which is visible to
passing traffic from both directions. It ensures a
sense of arrival and a positive first impression.
The face of the sign includes an edge illuminated
built up logo and lettering which highlights the
entrance after dark. The rear of the sign includes
simple directional information plus a ‘thank you’
message.
The sign is bordered by a resin bound gravel
surround to protect against grass cutting equipment.
Construction principles_3mm aluminium
cladding panels with fully welded and dressed
returns. Mounted to heavy duty fabricated aluminium
frame using hidden security fixings. Built up logo to
be edge illuminated using white chainlinked LED’s
through clear acrylic spacer panels. Full construction
specification can be found at rear of this document
(Section 7).
Size a)_4500x2700mm (Main campus entrance)
Size b)_2500x1500mm (Alexandra Park entrance)
EventsEvents:Postgrad Visit Day19th June 2013
Undergrad Visit Day28th August 2013
Register atlancaster.ac.uk
www.lancaster.ac.uk
Welcome to our Campus
We hope that you enjoyed your visitand we look forward to seeing you again.
M6 Motorway City Centre
100 cap ht
25mm deep
shouldered clear
acrylic logo and let-
tering with blockout
vinyl on face and
white ‘LED’ illumi-
nation from clear
returns.
vinyl graphics
only on revese
of sign.
12LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
70 70 140
140
3.02 | Main Entrance Events Sign EX2
To promote important University events and
achievements it is important to have promotional
signage at the campus entrances. The Event
Signs serve to be informative whilst promoting
the University to visitors and the local
community.
The signs consist of interchangeable trays
that carry temporary digitally printed messages
to facilitate regular updates. There is also
updateable LED message board included for
temporary event information.
Construction principles_140mm stainless steel
posts and fabricated frame supporting 3mm
aluminium panels. Lower x4 panels to be easily
removable to facilitate regular updates. x4 additional
panels to be stored for roll-off / on. Graphics to
be digitally printed labels. Posts to extend below
ground level to bolt onto rag bolt cage. Size of
foundation subject to Structural Engineers report.
Size)_1800x5000mm
140 cap ht
1500x1350mm
ultrabright LED
display board with IP65
rated case,
GSM modem with remote
programming
capability via a
Windows based PC.
100mm cap ht letters
x16 characters/line
300
450
450removable
450removable
450removable
450removable
1100
EventsPG Visit Day19th Jun 2013
UG Visit Day28th Aug 2013
EVENTS
1500x1350mmultrabright LED display board with IP65 rated case, GSM modem with remote programming capability via a Windows based PC.100mm cap ht letters x16 characters/line
13LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
3.03 | Campus Perimeter Signs EX3
The University borders the A6 dual carriageway
and M6 motorway. Signage along these
perimeters offer a sense of arrival and
raise the University profile.
The signs are made from flex face boxes with
tensioned PVC skins, with the option of internal
illumination if required.
Graphics should always be simple branded
messages that are clearly visible to fast
moving traffic.
Construction principles_extruded aluminim flex
face frame mounted to painted 140mm mild steel
posts. Flex face to be tensioned, digitally printed
PVC, silk lacquered for UV and wipe clean
protection. Full construction specification can
be found at rear of this document (Section 7).
Size a)_4500x4700mm (M6 South)
Size b)_3500x4000mm (M6 North_x1 or A6_x3)
2900/2200
1800
4500/3500
14LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
1200
800
1270
100
Visitor OrientationOn Route to
Barker House Farm
quantity increased to x2 as per architect drawings
Visitor Orientation
ITEM 1_EAST_S/S_1270x1200mm
BigforthFarm
University Main Entrance
Gre
en L
ane
(no
acce
ss to
U
nivers
ity)
A
CB
D
E
F
HI
K
J
Lib
rary
Ave
nu
e
Bo
wla
nd
Ave
. So
uth
Farr
er A
ven
ue
Gill
ow
Ave
nu
e
Pend
le A
venu
e
Graduate East Avenue
A6 South (to M6 Junction 33)
A6 North (to Lancaster City Centre)
M6 Motorway
Lon
sdal
e So
uth
Ave
.
Car
tmel
Wes
t A
ve.
Cartmel South Ave.
Sou
th D
rive
Furn
ess
Ave
nu
e
Fyld
e A
ven
ue
Tow
er A
ven
ue
Un
der
pas
s (B
us
Sto
p)
Big
fort
h D
rive
Un
der
pas
s (B
us
Sto
p)
Ale
xan
dra
Sq
uar
e
North East Drive
Co
un
ty A
ve.
Ro
ssen
dal
e A
ve.
No
rth
Dri
ve
Cycle routeto town
Barker HouseSports Pitches
North West Drive
Bowland Ave. East
Bo
wla
nd
Ave
. No
rth
Joh
n C
reed
Ave
.
South Spine
North Spine
Lancaster Square
South East Drive
Geo
rge
Fox
Ave
nue
Phys
ics
Ave
.
South West Drive
Alexandra Park Drive
Alexandra Park D
rive
Hazelrigg Lane
Bar
kers
Dri
ve (
A6
Sou
th E
ntr
ance
)
Gra
du
ate
Sou
th A
ve.
Alexandra Park
Gra
du
ate
Lan
e
Grass Playing PitchGrass Playing Pitch
Grass Playing PitchGrass Playing Pitch
Sports Field Car Parkports Field Car Park
Astro Turf Pitch
Grass Playing Pitch
Grass Playing PitchGrass Playing Pitch
Grass Playing Pitch
Astro Turf PitchTennis Courts
Gra
du
ate
No
rth
Ave
.
Cycle route to Ellel & Galgate
Gri
zeda
le A
ve.
G
L
11
3930
37
38
31
2823
34
32 36
55
60
61
58
63
64
65
66
67 68
52
57
54
16
2510
14 15a
15
1312
917
7
27
19
3
4
18
21
20
29
40
4149
49
24
33
45
50
47
48
41
42
8
62
59
35
6
5
44
43
51
2S
W
N
E
1
31 Alexandra Square (Shops & Banks)15 ASH House15a Islamic Prayer Room1 Bailrigg Conference Centre65 Barker House Farm6 Bigforth Farm14 Bowland Annexe28 Bowland Main & College12 Bowland Hall23 Bowland North30 Bowland Tower East37 Bowland Tower South66 Cartmel College
68 Cartmel Family housing40 Central Workshops and Stores13 CETAD24 Chaplaincy Centre54 Charles Carter 25 Conference Centre3 County Field Residences7 County Main & College18 County South20 County South Residences38 Edward Roberts Court51 Engineering Building27 Faraday Building
21 FASS Building42 Furness College41 Furness Residences47 Fylde College49 Fylde Residences55 George Fox63 Graduate College 67 Graduate Townhouses11 Great Hall57 Grizedale College58 Grizedale College Residences62 InfoLab2160 ISS Building
16 Jack Hylton Music Rooms19 John Creed Building43 Lancaster Environment Centre59 Lancaster House Hotel2 LEC Remote Workshops36 Library4 LICA Building64 Lonsdale College52 Management School45 Medical Centre10 Music Building9 Nuffield Theatre61 Pendle College
17 Peter Scott Gallery29 Physics Building48 Postgraduate Statistics Centre44 Pre-School Centre8 Round House35 Ruskin Library34 Security Lodge39 Slaidburn House (Students' Union)5 Sports Centre33 University House32 University Reception 50 Whewell Building
CCTV in operation for your personal safety and protection.
A
Principal route withwheelchair access
Key
Roads
Bus Stops
Woodland Trail
Campus buildings
Walkways
Visitor Car Parks A - L
Pay and Display Machines
Car parking for peoplewith disabilities
Water
Cycle Route
Designated BBQ Area
One Way system
A
(EAST FACING)
3.04 | Campus Map Post Signs EX4
Campus map post signs are positioned at key
wayfinding points across campus. They help
to orientate the user and direct them to a final
destination.
The signs are be single sided. The map should
always be orientated to match the users viewpoint
(East or West). Campus maps should not be supple-
mented with other directional information.
Construction principles_10mm thick aluminium
panel with hidden locking device, 100mm square
section aluminium posts (5mm wall) with 3mm
radiused corners. High definition digitally printed vinyl
graphics to be applied to painted aluminium surface,
finished with protective clear satin finish
UV resistant vinyl. Full construction specification
can be found at rear of this document (Section 7).
Size_1270x2000mm
Youare
here
40mm cap ht
Each map should have a‘You are here’
marker
The Key should list buildings
in alphabetical order only
75
5075
75 75
15LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
1200
1270
Visitor OrientationEntrance to
Barker House Farm
quantity increased to x2 as per architect drawings
ITEM 2_WEST_S/S_1270x1200mm
31 Alexandra Square (Shops & Banks)15 ASH House15a Islamic Prayer Room1 Bailrigg Conference Centre65 Barker House Farm6 Bigforth Farm14 Bowland Annexe28 Bowland Main & College12 Bowland Hall23 Bowland North30 Bowland Tower East37 Bowland Tower South66 Cartmel College
68 Cartmel Family housing40 Central Workshops and Stores13 CETAD24 Chaplaincy Centre54 Charles Carter 25 Conference Centre3 County Field Residences7 County Main & College18 County South20 County South Residences38 Edward Roberts Court51 Engineering Building27 Faraday Building
21 FASS Building42 Furness College41 Furness Residences47 Fylde College49 Fylde Residences55 George Fox63 Graduate College 67 Graduate Townhouses11 Great Hall57 Grizedale College58 Grizedale College Residences62 InfoLab2160 ISS Building
16 Jack Hylton Music Rooms19 John Creed Building43 Lancaster Environment Centre59 Lancaster House Hotel2 LEC Remote Workshops36 Library4 LICA Building64 Lonsdale College52 Management School45 Medical Centre10 Music Building9 Nuffield Theatre61 Pendle College
17 Peter Scott Gallery29 Physics Building48 Postgraduate Statistics Centre44 Pre-School Centre8 Round House35 Ruskin Library34 Security Lodge39 Slaidburn House (Students' Union)5 Sports Centre33 University House32 University Reception 50 Whewell Building
CCTV in operation for your personal safety and protection.
Visitor Orientation Adjacent toLICA Building
University Main Entrance
Gre
enLa
ne (n
o a
cces
s to
Uni
vers
ity)
A
CB
D
E
F
H I
K
J
Lib
rary
Ave
nu
e
Bo
wla
nd
Ave
. So
uth
Farr
er A
ven
ue
Gill
ow
Ave
nu
e
Pendle AvenueGraduate East A
venue
A6 South (to M6 Junction 33)
A6 North (to Lancaster City Centre)
M6 Motorway
Lon
sdal
e So
uth
Ave
.
Car
tmel
Wes
t A
ve.
Cartmel South Ave.
Sou
th D
rive
Furn
ess
Ave
nu
e
Fyld
e A
ven
ue
Tow
er A
ven
ue
Big
forth
Drive
Un
der
pas
s (B
us
Sto
p)
Ale
xan
dra
Sq
uar
e
North East Drive
Co
un
ty A
ve.
Ro
ssen
dal
e A
ve.
No
rth
Dri
ve
Cycle routeto town
Barker HouseSports Pitches
North West Drive
Bowland Ave. East
Bow
land
Ave
. Nor
th
Joh
n C
reed
Ave
.
South Spine
North Spine
Un
der
pas
s (B
us
Sto
p)
South East Drive
Geo
rge
Fox
Ave
nu
e
Phys
ics
Ave
.
South West Drive
Alexandra Park Drive
Alexandra Park D
rive
Hazelrigg Lane
Bar
kers
Dri
ve (
A6
Sou
th E
ntr
ance
)
Gra
du
ate
Sou
th A
ve.
Alexandra Park
Gra
du
ate
Lane
Grass Playing Pitch
Grass Playing Pitch
Grass Playing Pitch
Grass Playing Pitch
Sports Field Car Parkports Field Car Park
Astro Turf Pitch
Grass Playing Pitch
Grass Playing Pitch
Grass Playing PitchGrass Playing Pitch
Astro Turf Pitch Tennis Courts
Gra
du
ate
No
rth
Ave
.
Cycle route to Ellel & Galgate
Grizedale A
ve.
G
L
Lancaster Square
11
39 30
37
38
31
28 23
34
3236
55
60
61
58
63
64
65
66
6768
52
57
54
16
2510
1415a
15
1312
917
7
27
19
3
4
18
21
20
29
40
4149
49
24
33
45
50
47
48
41
42
8
62
59
35
6
5
44
43
51
2 S
W
N
E
1
A
Principal route withwheelchair access
Key
Roads
Bus Stops
Woodland Trail
Campus buildings
Walkways
Visitor Car Parks A - L
Pay and Display Machines
Car parking for peoplewith disabilities
Water
Cycle Route
Designated BBQ Area
One Way system
A
(WEST FACING) 800
3.05 | Campus Map Wall Signs EX5
Campus map wall signs are positioned onto
walls along key wayfinding routes across
campus. They help to orientate the user
and direct them to a final destination.
The map should always be orientated to match
the users viewpoint (East or West). Campus maps
should not be supplemented with other directional
information.
The signs have been highly specified to be durable.
Construction principles_10mm thick aluminium
panel with hidden locking device for easy removal,
high definition digitally printed vinyl graphics applied
to painted aluminium surface, finished with clear
satin finish UV resistant vinyl. Hidden security screw
fixings along to and bottom edge of sign
secure it to machined aluminium wall straps.
Size_1270x1200mm
Each map should have a‘You are here’
marker
The Key should list buildings
in alphabetical order only
Youare
here
40mm cap ht75
5075
75 75
16LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
1430
1875
350
3838
3.06 | Directional Monolith EX6
Along the campus perimeter road are wayfinding
monolith signs.
Directional Monoliths are single or double sided and
should have content restricted to buildings or
facilities in close proximity to the sign to prevent
information overload.
Directional content should always be displayed as
per the content guidlines in section 2.5.
Construction principles_3mm thick rolled (curved
face), folded, welded and dressed panels, mounted
onto an aluminium box section frame with 6mm
thick internal ribbing sections to protect against
distortion. Two internal 150mm square box section
posts welded to internal framework to extend below
ground level. Side capping sections to hide fixings
where panels mount onto framework - these
sections are to be secured in place by a single
security screw on the top. Full construction
specification can be found at rear of this
document (Section 7).
Size_1506x2225mm
CAMPUS WATCH www.lancs.ac.uk/campuswatch
CAMPUS WATCH www.lancs.ac.uk/campuswatch
Great Hall(Nuffield Theatre & Peter Scott Gallery)
University House Reception
Visitor Car Parks A - C
Alexandra Park
Visitor Car Parks D - J
220
55
35
140
140
220
40
220 220
17LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
150
150
80 80
200
250
150
150
150
150
150
800
1340
Accessible Route
Great Hall(Nuffield Theatre & Peter Scott Gallery)
Rossendale Avenue East
Lancaster Square
Round House
County Main & College
Recycling Point
LICA
150
3.07 | Directional Twin Post and Panel EX7
Directional post and panel signs are located
along major vehicular and pedestrian routes
around campus.
They can be single or double sided and should have
content restricted to buildings or facilities in close
proximity to the sign to prevent information overload.
If the sign is located at near to a road then the road
title should appear in the white header section.
Directional content should always be displayed as
per the content guidlines in section 2.5.
Construction principles_80mm square section
Stax aluminium posts with finishing cap and 20mm
deep extruded aluminium panels. All coloured bands
to be masked and sprayed , all graphics to be
applied vinyl. No plastic fixings of any kind. Full
construction specification can be found at rear of
this document (Section 7).
Size_1500 x various mm
800to lower
plank
accessible route markers should always appear
at the bottom of the sign (in red)
If a road name is required it
should always be on the white header at the top of the sign
Standard Panel Heights
a)_50mm
b)_100mm
c)_150mm
d)_200mm
e)_250mm
f)_300mm
200 70 cap ht
55 cap ht
30 cap ht
18LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
3.08 | Directional Wall Sign EX8
Directional tray signs are to be mounted to walls
at major intersections along pedestrian
walkways. Content is restricted to key
destinations in close proximity to prevent
information overload.
The height of wall signs vary depending upon the
amount of directional content although four standard
sizes are suggested to maintain a degree of
uniformity across campus.
A standard height of 2100mm to top of sign is
recommended although signs may also align to
architectural features to ensure they look like a
considered part of the facade.
Construction principles_3mm aluminium tray with
45mm fully welded and dressed returns. Mounted
to hidden brackets using colour matched security
fixings along top and bottom returns. All coloured
bands to be masked and sprayed, all graphics to
be computer cut applied vinyl. Polystyrene infill to
be used to resist impact damage. Full construction
specification can be found at rear of this document
(Section 7).
Size_1000 x various mm
Standard Sizes
a)_1000x500mm
b)_1000x750mm
c)_1000x1000mm
d)_1000x1250mm
1000
125
750
125
Furness College
Fylde College
Grizedale College
Pendle College
Edward Roberts Court
Accessible Route
45
2100to top of
sign
accessible route markers should always appear
at the bottom of the sign (in red)
38 cap ht
170
125
70
19LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
Faraday Building
Welcome to
ChemistryMain Entrance
51
750 6
1100
3.09 | Building Occupancy Sign EX9
Building occupancy wall signs are used to iden-
tify main entrances at ground level. They sign the
building title and list major departments, schools
or facilities within.
Signs should align to architectural features to ensure
they look like a considered part of the facade
although a standard height of 2100mm to top
of sign is recommended.
Construction principles_6mm deep white painted
aluminium frame with modular interchangeable
painted aluminium directory panels set flush within
surface. Panels to have hidden locking mechanism
and surface printed graphics with clear protective
lacquer finish. Full construction specification can be
found at rear of this document (Section 7).
Size a)_750 x 1100mm
Size b)_500 x 725mm
2100to top of
sign
modularinterchangeable
panelswith hidden
locking mechanism
replacement panel
(with non-term opening times)
building reference
(as detailedon map signs)
35 cap ht
30
20
120
100
25 cap ht
3030
Open Access7.30am to 8pm
Student Library Card Swipe Access 8pm to 10pm, Monday to Friday9am to 6pm, Saturday and Sunday
Staff/PhD Library Card Swipe Access24 hours/ 7 days per week
Welcome to
ChemistryMain EntranceOpen Access9am to 5pm
Student Library Card Swipe Access 5pm to 7pm, Monday to Friday9am to 8pm, Saturday and Sunday
Staff/PhD Library Card Swipe Access24 hours/ 7 days per week
20LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
Building Name signs are used to identify building
main entrances from distance. These signs are
to include the building title only.
Signs should align to architectural features to ensure
they look like a considered part of the facade
although standard sizes are suggested below.
The width to height ratio should remain 4:1
where possible although this may be extended
to accommodate long titles.
If building title needs to be sensitive to a building
facade individual letters may be used (EX10b).
Construction principles EX10a_3mm aluminium
tray with 45mm fully welded and dressed returns.
Mounted to hidden brackets using colour matched
security fixings along top and bottom returns. All
coloured bands to be masked and sprayed, all
graphics to be computer cut applied vinyl.
Polystyrene infill to be used to resist impact damage.
Construction principles EX10b_built up stainless
steel letters with 20mm returns and satin polish DP1
(vertical grain) and 10mm spacer studs on rear
3.10 | Building Naming / Occupancy High Level EX10a / 10b
University House
University House
1000
200
4000
Size 10a1)_4000 x 1000mm
Size 10a1)_3000 x 750mm
Size 10a2)_2000 x 500mm
Size 10a3)_1200 x 300mm (residences)
Size 10b1)_200mm cap ht
Size 10b2)_300mm cap ht
EX10a
EX10b
20mm
polished stainless steel
with 20m returns
21LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
3.11 | High Level Signs EX11
High level signs raise brand profile around
campus. The use of this sign type is currently
restricted to just University House and The
Sports Centre although this may change.
They are positioned onto buildings that align with
the road and pedestrian routes around campus or
near main entrances. They should always be aligned
to an architectural feature where possible to look a
considered part of the facade. Each sign should be
sized appropriately to its location but retain the
proportions set opposite.
The University logo is the combination of the text in
grey Frutiger typeface positioned to the left of the
red symbol. These elements must never be
separated or adjusted in either size relationship.
Construction principles_built-up descaled steel
lettering and logo with painted finish all round and
60mm returns. Rear of letter to be 5mm clear
polycarbonate fixed into face through side return.
Letters to be ‘Halo’ illuminated using white
chainlinked LED’s. Letters to be stood 20mm
from wall surface.
Size a)_5000 x 3000mm
Size b)_4000 x 2250mm
Size c)_3000 x 1690mm
logo for dark walls (with white lettering)
logo for dark walls (with grey lettering)
descaled steel face with insetpolycarbonate
back panel
60mm
NEW LOGO TBC
22LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
Monday to Friday08:00 - 18:00
Terms & Conditions
Have you payed and displayed?
Visitors must clearly display a valid pay
and display ticket or visitor scratch card.
car share permits are also valid.
All vehicles and contents are parked at
owners risk.
ParkingVisitor
B
side A side B
1600
835
600
5015
Vis
ito
rs
BParkingVisitor
3.12 | Gateway Visitor Car Parks EX12
Car parks A - L are clearly identified on directional
and campus map signs. The entrance to each visitor
car park should be clearly identifed so users know
they’ve reached their nominated destination.
The signs are double sided with large identification
graphics on the front and disclaimer / regulatory
information on the rear.
Signs need to be positioned so that they are visible
to traffic from all directions without causing physical
obstruction to pedestrian users.
Construction principles_3mm aluminium panels
with rolled vertical edges mounted onto 90mm
round section posts using channel and clip system.
Digitally printed graphics onto optically clear vinyl
applied edge to edge of each panel. Full
construction specification can be found at
rear of this document (Section 7).
Size_600 x 3000mm500
Gateway Visitor Parking Areas = to be confirmed
390 cap ht
50 cap ht
220 cap ht
20 cap ht
520
130
85
165
60
200
200
350
30
30
60 60
480
23LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
45
545
600
VisitorParking
G
car park Kalternative
plan view
car park Jalternative
3.13 | Ring Road Visitor Parking Bays EX13
Visitor parking bays around the campus
perimeter road are clearly identified using
lamp post mounted notices.
The signs are single sided with large identification
graphics at the top and disclaimer / regulatory
information at the bottom.
Signs should be positioned so that they are visible
to traffic from all directions above the height of
parked cars.
Construction principles_3mm aluminium panels
with rolled vertical edges mounted EXISTING lamp
columns using channel and clip system. All corners
to have 15mm radius to avoid pointed edges.
Digitally printed graphics onto optically clear
vinyl applied edge to edge of each panel.
Size_450 x 600mm
450
1400to bottom of
sign
Perimeter road visitor parking bays = areas to be confirmed
240 cap ht
40 cap ht
40 40370
Monday to Friday 08:00 - 18:00 Monday to Friday 08:00 - 18:00
Monday to Friday 08.00 - 18.00 hours
Visitors must clearly display a valid pay and display ticket or visitor scratch card. Car share
permits are also valid.
All vehicles and contents are parked at owners risk.
Monday to Friday 08.00 - 18.00 hours
Visitors must clearly display a valid pay and display ticket or visitor scratch card. Car share
permits are also valid. All vehicles and contents are parked at owners risk.
Alexandra Park Pay and Display tickets also valid.
Monday to Friday 08.00 - 18.00 hours
Visitors must clearly display a valid pay and display ticket or visitor scratch card. Car share
permits are also valid. All vehicles and contents are parked at owners risk.
This car park is for pay and display and construction permit holders only
and is locked daily at 23:45.
VISITORParking Zone
VISITORParking Zone
VISITORParking Zone
24LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
450 450
600
450
EX14a EX14b
450Visitor parking bays around the campus
perimeter road should be clearly identified
using lamp post mounted notices.
The signs are single sided with large identification
graphics at the top and disclaimer / regulatory
information at the bottom.
Signs should be positioned so that they are visible
to traffic from all directions above the height of
parked cars.
Construction principles_3mm aluminium panels
with rolled vertical edges mounted EXISTING lamp
columns using channel and clip system. Graphics to
be digitally printed vinyl. All corners to have 15mm
radius to avoid pointed edges. Full construction
specification can be found at rear of this document
(Section 7).
EX14a Size_450 x 600mm
EX14b Size_450 x 600mm
3.14 | Ring Road Visitor, Staff, Student Parking Bays EX14
Monday to Friday 08.00 - 18.00 hours
Staff Permit holders only.All vehicles and contents
are parked at owners risk.
STAFFParking Zone
Monday to Friday 08.00 - 18.00 hours
Student and Staff Permit holders only. Residential Conference
Permits valid in vacations.
Alexandra Park pay and display tickets also valid here.
STUDENTParking Zone
30 cap ht
14 cap ht
25LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
SIDE A SIDE B
150
470
80
1100
700 150
Main Campus
Start of Accessible Route
Look for the signs with the red band
Accessible Route
Main Campus
End of Accessible Route
Visitor Car Park M
Accessible Route
3.15 | Accessibe Route Totems EX15
Accessible routes run from one end of campus
to the other. They start at busy wayfinding points
such as University House reception and visitor
car parks.
The signs are double sided and clearly visible
without causing physical obstruction. They highlight
direct accessible routes to major car parks and
campus facilites.
Construction principles_3mm thick folded, welded
and dressed panels, mounted onto an aluminium
box section frame. Two internal 125mm square
box section posts welded to internal framework to
extend below ground level. Panels to be secured
in place by a single security screw on the top.
Coloured bands to be masked and sprayed, all
other graphics to be applied vinyl. Full construction
specification can be found at rear of this document
(Section 7).
Size_700 x 1800mm
38 cap ht
30 cap ht
26LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
2880 500
15 1510 10
10
2000 500
Our Departments• Chemistry• Computing and Communications• Engineering• Lancaster Environment Centre• Mathematics and Statistics• Physics• Psychology
For all enquiries please contactour faculty office, Room 123.
Faculty of Science and Technology
before after
toughened glass panel with stain-less steel fixings
2300
Welcome
digitally printed
contravision
etch effectmanifestation
3.16 | Faculty Entrance Signage EX16
Each faculty entrance is promoted using large
feature signage. Each entrance varies in size and
content but the material specification should
remain consistent.
A 10mm toughened glass panel with digitally printed
graphics on rear and bespoke heavy duty stainless
steel fixings. Glazing around the entrance doors has
have digitally printed contravision vinyl applied to the
glazed surface.
Construction principles_10mm toughened glass
panel with full colour digitally printed graphics on
rear. Stainless steel bracket along bottom edge and
stainless steel barrels at top. Side windows have
‘one way’ contravision digitally printed vinyl graphics.
Etch effect manifestation applied to doors.
Size_2880 x 2300mm (glass panel)
Size_500 x 2500mm (contravision)
Size_2000 x 300mm (etched manifestation)
27LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
1400
3240
340
3.17 | Building Development Signs EX17
Temporary Building Development Signs highlight
improvements on campus when there is no
hoarding surfaces available. They promote and
direct people to new facilities and departments
while building work takes place. They are meant
to supplement temporary hoarding graphics
used by construction companies.
The signs should be positioned where they are clearly
visible from major thoroughfares to identify temporary
routes due to construction.
Construction principles_ 5mm composite aluminium
panels fixed to 100mm painted mild steel posts using
channel and clip system. 5mm composite aluminium
panels to have surface printed graphics protected
with clear protective overlay.
Size_1400x3580mm
80 cap ht
New Engineering Building
28LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
500
EX17a EX17b
40 20 50
674A2cabinet
200
200
200
50
3.18 | Small Events Sign EX18
To promote important University events
and achievements it is important to
have promotional signage near pedestrian
circulation routes.
There are two options; a permanant ground fixed
cabinet (EX17a) and a portable A1 poster display
unit (EXT17b). Both types consist of exterior
poster holders which display paper inserts
produced by the University.
Construction principles EX18a_50mm painted
aluminium posts with 30mm deep A2 poster
cabinet (onthecase) with aluminium frame and
toughened glass window mounted flush into
40mm painted aluminium tray sign. Header to
be surface printed and lacquered.
Construction principles EX18b_A1
‘windjammer’ poster cabinet with weighted base
and built in wheels for easy movement. Frame
to be snap shut with clear PVC window.
Size 18a)_500x1274mm
Size 18b)_720x1140mm
Postgraduate Visit Day19th June 2013
EVENTS
586
833 1140A1cabinet
Postgraduate Visit Day19th June 2013
EVENTS
29LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
3.19 | Hoarding Signs EX19
New campus developments are surrounded
by safety hoardings which can be used to
support promotional graphic panels.
The graphics should be carefully formatted to
match our University brand. Content should be
simple and informative with careful attention to
text heights and reading distances.
To ensure that hoarding signage conforms to
University standards approval should be gained
from one or more of the following people:
• Senior Projects Manager
• Facilities Marketing & Communications
Manager
Size EX19)_individually assessed.
Construction principles EX19_
OPTION A
Material: Dibond
Use for “front of house’ projects where
heavy footfall & close up viewing
occurs. Screw fixings, covered by
colour matched caps. Lasts 18-24
months with protective film.Dibond is a composite sheet material made
from a plastic core sandwiched between
aluminium with a high gloss white finish, which
makes it ideal for high resolution digital surface
printing. Dibond exibits minimal expansion and
contraction which means that sheets can be
butted together, with no gaps, for maximum
visual impact.
The addition of an optional clear protective
overlay film protects the printed graphics and
adds to the longevity and durability of the print.
Construction principles EX19_
OPTION B
Material: Forex
Use for the majority of projects on
campus where medium footfall and mid
range viewing occurs. Screw fixings,
covered by colour matched caps.Forex is a closed cell, lightweight rigid PVC sheet
material with a silky matt surface that is ideal for
digital printing onto the surface. Forex exhibits
some expansion and contraction which means
that large sheets need a 2mm gap between them
to allow for this. The panels to be screw fixed
and covered using colour matched caps.
Construction principles EX19_
OPTION C
Material: Corex
Use for the minimum footfall and long
distance viewing occurs, for example,
hoardings located on the outer
campus/ring road. Fixed using stainless
steel staples. Lasts approximately 12
months.Corex is a corrugated hollow core polypropylene
sheet material with a satin white finish. For best
results, print direct onto treated surface, but
printed vinyl can also be applied. Corex exhibits
some expansion and contraction, meaning it
requires a 2mm gap between panels. Due to it’s
lightweight srtructure, is best fixed to wooden
hoarings with industrial grade stainless steel
staples.
See options A, B & C below
‘X’ assess on the basis of each
project
Your library is being refurbished to provide an
outstanding research and learning space
Library RefurbishmentPhased refurbishmentcompleting early 2016
To find out more visit www.lancaster.ac.uk/library/refurbishment facebook.com/LancasterUniversityLibrary @LancasterUniLib #lulibraryrefurb To find out more visit www.lancaster.ac.uk/library/refurbishment facebook.com/LancasterUniversityLibrary @LancasterUniLib #lulibraryrefurb
We are creating
a place to studyProviding spaces to meetall your study needs ‘Y’ assess on
the basis of each project
30LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
3.20 | Temporary Banners EX20
Promotional banners advertise events and
achievements across the University.
The graphics should be carefully formatted to match
the University brand. Content should be simple and
informative with careful attention to text heights and
reading distances.
To ensure that banner signage conforms to University
standards approval should be gained from:
• Facilities Marketing & Communications
Manager
Construction principles EX20_heavy duty welded
and stiched PVC banner material with full colour
digital print to both sides. Support system to be
EN40 compliant ‘Airspring’ banner system with spring
loaded fibre glass arms and aluminium
brackets to deflect windloadings from lamp columns.
Size EX20a)_750x2500mm
Size EX20b)_600x3000mm
2500to bottom of
sign minimum
Airspring banner system with
carbon fibre arms connected to
aluminium support brackets is fully compliant with
the Government’s EN40 Regulation about maximum
wind-load on any type of street
lighting column
31LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
3.21 | Window Graphics EX21
Promotional window graphics highlight
achievements and events whilst emphasizing
entrance areas in a vibrant manner.
The graphics should be carefully formatted to
match the University brand whilst ensuring a
cohesive, campus wide strategy.
To make sure window signage conforms to
University standards approval should be gained
from one or more of the following people:
• Senior Projects Manager
• Facilities Marketing & Communications
Manager
Construction principles EX21_3M 8173 PWGF
series UV print compatible, perforated window
vinyl for one way viewing; 1 - 5 year-life.
Size EX21)_individually assessed
digitally printed perforated window vinyl with black on rear for one-way viewing.
Vinyl must be completely removable (including all adhesive) using mild cleaning solvent spray.
All promotional window graphics must display the University brand and not clash with adjacent building signage
32LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 3.0 EXTERNAL SIGNS
3.22 | Temporary Diversion Signs EX22
When construction is taking place, temporary
diversion signs direct pedestrians along
alternative routes. They should be mounted
onto existing posts where possible.
The directional arrows should be displayed on a
yellow background to highlight it as a temporary
route. Directional information should be at the top
of the sign with additional text detailed below.
To make sure diversion signage wording conforms
to University standards approval should be gained
from one or more of the following people:
• Landscape Manager
• Maintenance Manager
• Projects Manager
• Travel and Environment Manager
• Marketing & Communications Manager
Construction principles EX22_3mm painted
aluminium panel with printed graphics. Fixed
to existing posts using channel and clip system
with countersunk rivets.
Size EX22)_450x600mm
600
450
Temporary route to Alexandra Park& Pitches 5 & 6
Installation of new 3rd Generation PitchFeb - Jun 2014
30 cap ht
10mm radiused corners cap ht
2100to bottom
of sign
Temporary route to Alexandra Park& Pitches 5 & 6
Installation of new 3rd Generation PitchFeb - Jun 2014
33LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 4.0 INTERNAL SIGNS
4.00 | Internal Signage
The following chapter details a family of slim
(6mm) modular, interchangeable painted
aluminium signs that are designed to navigate
users from building entrance to a specific room.
This is achieved by placing clearly visible signs with
consistent and concise messages at decision points
along all major corridors and wayfinding routes.
34LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 4.0 INTERNAL SIGNS
20
24@40
450
10
150
500100
Faculty of Health & Medicine
Health Research
Toilets & Showers
DFlats 1 to 9
Seminar Rms Computer Labs Lecture Theatres
Furness College
Toilets & Showers
Faculty of Health & Medicine
This is a no smoking building
Toilets
Furness Bar
Furness College Offices
Furness Porter’s Lodge
Furness JCR & TV Room
Lecture Theatres 1, 2 & 3
Lancaster Medical School
CETAD
Faculty Offices
Biomedical & Life Sciences
Lancaster Medical SchoolC
This level
B
A
Faculty of Health & Medicine
Health Research
Toilets & Showers
DFlats 1 to 9
Seminar Rms Computer Labs Lecture Theatres
Furness College
Toilets & Showers
Faculty of Health & Medicine
This is a no smoking building
Toilets
Furness Bar
Furness College Offices
Furness Porter’s Lodge
Furness JCR & TV Room
Lecture Theatres 1, 2 & 3
Lancaster Medical School
CETAD
Faculty Offices
Biomedical & Life Sciences
Lancaster Medical SchoolC
This level
B
A
4.01 | Entrance Directory IN1
A floor level directory detailing all levels and
departments of a building should be located
within each building entrance.
The building title should appear on the top left of the
sign. Directory information should be listed in floor
order with the top floor at the top of the directory.
Room titles for each floor are listed alphabetically
with toilets listed last.
Signs should be positioned on walls where there is
room to stop and view the sign without causing
obstruction at a height of 2100mm to top of sign or
align to an architectural feature (doorway).
Construction principles_6mm deep modular
painted aluminium sign directory with
interchangeable, digitally printed panels and hidden
locking mechanism. Map to be digitally printed direct
to surface. Plastic sign systems are not to be used.
Final clear protective layer (100% matt) to be added
protect the printed surfaces from damage.
Size a)_600mm x various (building specific)
2100
62.5
25
62.5
60 cap ht
16 cap ht
50 50 35
35LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 4.0 INTERNAL SIGNS
500
20
100
150
10
18@40
4.02 | Stair & Lift Directory IN2
Stair / Lift Directories should be positioned in
the lobby of all major stairs and lifts.
The building title should appear on the top left of the
sign. Directory information should be listed in floor
order with the top floor at the top of the directory.
Room titles for each floor are listed alphabetically
with toilets listed last.
Signs should be positioned on walls where there is
room to stop and view the sign without causing
obstruction to walkways at a height of 2100mm to
top of sign or align to an architectural feature
(doorway).
Construction principles_6mm deep modular
aluminium sign directory with interchangeable,
digitally printed panels and hidden locking
mechanism. Plastic sign systems are not to
be used.
Size a)_600mm x various (building specific)
2100
C
BThis level
Synthetic Research C18
Synthetic Teaching C05
Offices C13 - C15
Lift & Stairs
Offices B18 - B20
Lifts & Stairs
Non Synthetic Research B04
Non Synthetic Teaching B25
AData Analysis Laboratories A41
Offices A03 - A40
Lift & Stairs
Computational Research A10
NMR Suite A58
Lockers & Showers
Toilets
Faraday Building
C
BThis level
Synthetic Research C18
Synthetic Teaching C05
Offices C13 - C15
Lift & Stairs
Offices B18 - B20
Lifts & Stairs
Non Synthetic Research B04
Non Synthetic Teaching B25
AData Analysis Laboratories A41
Offices A03 - A40
Lift & Stairs
Computational Research A10
NMR Suite A58
Lockers & Showers
Toilets
Faraday Building
62.5
25
62.5
60 cap ht
16 cap ht
50 50 35
36LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 4.0 INTERNAL SIGNS
AThis level
15
300
285
4.03 | Level Indicator IN3
Floor level indicators should be positioned within
all stairwells immediately opposite the stairs.
Mount at 1700mm to top of sign.
Construction principles_6mm deep modular
aluminium signage board with digitally printed
graphics and hidden release mechanism.
Size a)_300 x 300mm
1700 AThis level
130
30
30
25
30
37LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 4.0 INTERNAL SIGNS
20
1@1205@75
600
Offices A03 - A17
Data Analysis Labs A40 - A41
Offices A22 - A39
Lockers & Showers
Computational Research Laboratory A10
Offices A03 - A17
Data Analysis Labs A40 - A41
Offices A22 - A39
Lockers & Showers
Computational Research Laboratory A10
4.04 | Wall Mounted Directional IN4
Directional signs should be positioned at key
wayfinding decision points to navigate the
building.
Content should be restricted to departments and
facilities in the near vicinity using the stipulated
arrow hierarchy.
Where plenty of wall space is available an additional
blank plank should be included at the bottom of
each sign to allow for future additions.
Wall signs should be positioned 1700mm to top of
sign and should always be 600mm wide unless long
reading distances dictate larger text; then 900mm
planks should be used.
Construction principles_6mm deep modular
aluminium directional sign with interchangeable
locking panels and surface printed graphics.
Plastic sign systems are not to be used.
Size a)_600mm x various (sign specific)
1700
28
100 100
45
38LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 4.0 INTERNAL SIGNS
20
20
4@75
600
NMR Suite A58
Lockers & Showers
Data Analysis Labs A40 - A41
NMR Suite A58
Lockers & Showers
Data Analysis Labs A40 - A41
4.05 | Suspended Directional IN5
Suspended directional signs should be
positioned at key wayfinding decision points
when there is no wall space available.
They can be single or double sided. Content should
be restricted to departments and facilities in the near
vacinity and listed using the stipulated arrow
hierarchy.
Where ceiling heights allow, a blank plank should
be included at the bottom of sign to allow for future
additions.
Wall signs should be positioned 2200mm to under-
side of sign and should always be 600mm wide
unless long reading distances dictate larger text;
then 900mm planks should be used.
Construction principles_6mm deep modular
aluminium directional sign with interchangeable
locking panels and surface printed graphics.
Plastic sign systems are not to be used. Suspend
from ceiling using stainless steel wire suspension kit.
Size a)_600mm x various (sign specific)
2200
28
100
45
39LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 4.0 INTERNAL SIGNS
900
20
20
160Centre for Medical Education
Centre for Medical Education
Centre for Medical Education
4.06 | Wall Mounted Locational IN6
Locational signs are located above or next to
key department and facility entrances.
These signs offer limited space for text. With
clarity and legibility the priority of any sign, additional
descriptive words will not be included in the text.
Wall signs next to entrances should always be
positioned 1700mm to top of sign whilst those
above entrances should be centred in the available
space.
The sign sizes are dictated by line length with
standard widths being 900mm or 1200mm.
Construction principles_6mm deep modular
aluminium locational sign with interchangeable
locking panels and applied vinyl graphics.
Plastic sign systems are not to be used.
Size_900 x 160mm
centred above door(100mm above door if
high ceiling)
1700mmto top if wall
mounted
CL
40
CL
40LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 4.0 INTERNAL SIGNS
15
180
165
4 20 4
4.07 | Projecting Locational IN7
Projecting signs should always be positioned so
that the bottom of the sign aligns to the top of a
door frame, be at least 2200mm above floor level
and used where entrances are approached
side on.
Signs can be double or single side. Symbols should
be used where possible and text should be
simplified so that maximum cap heights can
be used.
Construction principles_modular aluminium
projecting sign with interchangeable sign panels
and applied vinyl graphics.
Size_300 x 330mm
PhysicsReception
alternativegraphiclayouts
2200mm to bottom of sign
hiddensecurity fixing
fabricatedsign sleeve
machinedwall bracket
100
75
45
CL
41LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 4.0 INTERNAL SIGNS
14
ReceptionReception 200
4.08 | Locational Lettering IN8
Some locational signs need to be sensitive to
their architectural surroundings, these tend to be
entrances to flagship buildings or major facilities
such as lecture theatres.
In these locations 10mm thick individual letters
should be screw fixed direct to the wall using 10mm
spacers. Cap heights should be appropriate to
available wall space and reading distances but
200 / 300mm is recommended as a standard.
Construction principles_10mm waterjet cut
stainless steel with horizontal brush finish DP1.
Screw fix flush to wall using hidden fixings.
Size_200mm cap height
10mm
10mm stainless steel letter with satin polish DP1
surafce finish
42LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 5.0 DOOR SIGNS
5.00 | Door Signs
The following pages detail a family of door signs
that are designed to clearly identify a room.
Cotent comprises of number and title, it’s
function and important details relating to the
occupants or safety.
Fixed room names such as Lecture Theatres,
Stores etc should have printed name panels. All
changeable information such as occupant names
should be printed onto an paper insert; protected
against tampering and damage by a clear acylic
panel.
For additional security, these acrylic panels are
lockable using a hidden steel pin that can be
unlocked by designated persons using a
magnetic key fob.
Signs bonded to glass doors require black vinyl
backing on rear of glazing to hide adhesive.
43LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 5.0 DOOR SIGNS
15
180
12
22
25
18
20
165
A13LV Switch
1700
10050
Signs may be door fixed or wall fixed (opening side) as above. Either option should be consis-tent throughout a building.
5.01 | Standard Door Signs D1
Sign type D1 is for non-occupied rooms such as
kitchens, stores etc.
Room numbers should always be printed in the top
left hand corner at 25mm cap height. Where
appropriate, a room name can be printed beneath.
Signs should always be mounted at a height of
1700mm to top of sign unless there is an obvious
door feature to align with at a similar height.
Signs bonded to glass doors require black vinyl
backing on rear of glazing to hide adhesive.
Construction principles - 6mm modular painted
aluminium door sign system with printed graphics.
Plastic sign systems are not to be used.
Size_180 x 180mm
A13LV Switch
A13LV Switch
44LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 5.0 DOOR SIGNS
15
180
70
47.5
C/L
165
D2b_female
D2e_unisex
D2a_male D2c_accessible
D2f_accessible / baby change
D2d_baby change
1700
10050
Signs may be door fixed or wall fixed (opening side) as above. Either option should be consis-tent throughout a building.
5.02 | Toilet Door Signs D2
Sign type D2 is a toilet or baby changing
door sign.
Signs consist of a 70mm tactile symbol centred on
the main panel.
Signs should always be mounted at a height of
1700mm to top of sign unless there is an obvious
door feature to align with at a similar height.
Signs bonded to glass doors require black vinyl
backing on rear of glazing to hide adhesive.
Construction principles - 6mm modular painted
aluminium door sign system with tactile graphics
protected by a clear lacquer. Plastic sign systems
are not to be used.
Size_180 x 180mm
45LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 5.0 DOOR SIGNS
Mr A Nother
15
30
180
165
1700
10050
Signs may be door fixed or wall fixed (opening side) as above. Either option should be consis-tent throughout a building.
5.03 | Single Occupancy Door Signs D3
Sign type D3 is for single occupancy rooms.
Room numbers should always be printed in the
top left hand corner with room descriptions printed
beneath.
Occupant names should be printed onto paper and
inserted behind a locking acrylic window to
prevent tampering. To produce your own paper
inserts please contact Facilities, Marketing &
Communications Manager in the Facilities team for
a copy of the Graphics CD.
Signs should always be mounted at a height of
1700mm to top of sign unless there is an obvious
door feature to align with at a similar height.
Construction principles - 6mm modular painted
aluminium door sign system with digitally printed
graphics and locking window feature. Plastic sign
systems are not to be used.
Size_180 x 210mm
A03Director’s Office
Mr A Nother
A03Director’s Office
Mr A Nother
12
22
25
18
20
A13Director’sOffice
46LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 5.0 DOOR SIGNS
B09Research Students
Mr A NotherMr A Nother
B04Administration Office
Mr A NotherMr A NotherMr A NotherMr A Nother
15
15
60
90
180
165
sign type D4
sign type D5
165
1700
10050
Signs may be door fixed or wall fixed (opening side) as above. Either option should be consis-tent throughout a building.
5.04 | Multiple Occupancy Door Signs D4 / D5
Sign types D4 & D5 are for multi-occupancy
rooms.
Room numbers should always be printed in the
top left hand corner with room descriptions printed
beneath.
Occupant names should be printed onto paper and
inserted behind a locking acrylic window to
prevent tampering. To produce your own paper
inserts please contact Facilities, Marketing &
Communications Manager in the Facilities team
for a copy of the Graphics CD.
Signs should always be mounted at a height of
1700mm to top of sign unless there is an obvious
door feature to align with at a similar height.
Construction principles - 6mm modular painted
aluminium door sign system with digitally printed
graphics and locking window feature. Plastic sign
systems are not to be used.
Size D4_180 x 240mm
Size D5_180 x 270mm
12
22
25
18
20
B09Research Students
Mr A NotherMr A Nother
B09Research Students
Mr A NotherMr A Nother
47LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 5.0 DOOR SIGNS
A65Electrical ServicesPlantroom
15
40
180
165
1700
10050
Signs may be door fixed or wall fixed (opening side) as above. Either option should be consis-tent throughout a building.
5.05 | Laboratory / Plantroom Door Signs D6
Sign type D6 is for laboratory and plant rooms
where warning or safety notices need to be
displayed.
Room numbers should always be printed in the
top left hand corner with room descriptions printed
beneath.
Safety notices should be printed onto paper and
inserted behind a locking acrylic window to
prevent tampering. To produce your own paper
inserts please contact Facilities, Marketing &
Communications Manager in the Facilities team
for a copy of the Graphics CD.
Signs should always be mounted at a height of
1700mm to top of sign unless there is an obvious
door feature to align with at a similar height.
Construction principles - 6mm modular painted
aluminium door sign system with digitally printed
graphics and locking window feature. Plastic sign
systems are not to be used.
Size_180 x 220mm
12
22
25
18
20
Danger400 volts
No unauthorisedentry
No naked flames
Dangerof death
A65Electrical ServicesPlantroom
Danger400 volts
No unauthorisedentry
No naked flames
Dangerof death
A65Electrical ServicesPlantroom
Danger400 volts
No unauthorisedentry
No naked flames
Dangerof death
48LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 5.0 DOOR SIGNS
Free In Use
A02Meeting Room 1
15
30
180
165
1700
10050
Signs may be door fixed or wall fixed (opening side) as above. Either option should be consis-tent throughout a building.
5.06 | Slider Door Signs D7
Sign type D7 is for meeting and conference
rooms.
Room numbers should always be printed in the
top left hand corner with room descriptions printed
beneath.
A vacancy slider that finishes flush to the top surface
of the sign highlights if the room is in use.
Signs should always be mounted at a height of
1700mm to top of sign unless there is an obvious
door feature to align with at a similar height.
Construction principles - 6mm deep painted
aluminium modular door sign system with digitally
printed graphics and vacancy slider.
Size_180 x 210mm
12
22
25
18
20
A13Meeting Room
Free In Use
A02Meeting Room 1
Free In Use
A02Meeting Room 1
49LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 5.0 DOOR SIGNS
20
260
350
Training Room 1 50
Ed diam iure eugiate mincill
Aliquat, corper alismol endiam, quis do odolore magnit luptatin velit utatet aliquam nit am ipsum et ullaore rciliquis ercipsum vel iriure dolor si bla accum quat. Ex et vullutat, qui te del digna faccum volobore dolobore el in ex eummy nos esed tat,
Quissi blamet aci blaortionsed magna atuer at vel ing et amconse feugiamcon henim dolor ad magna consed dignim ipit numsandiamet lore molore dio dolenim ver in ut dolorer iure diamet ent alis acin ulluptatum dolortion et praessenibh et adio et lor ipis num alit vulla faccumsan vendipit augait, commy nulla facing el dit, quamcon sequam, vullam, sum in utat, quat.
Im zzrilla ad magnim etumsandre miniscinim dignisit, sustrud duisl utat. Ut ex et nit aci tie essit laorem zzriusc iduipis am, se minim velit dit niam ad min ex elendio odolor accum veliqua tueriurer sum vel ut eumsandit el il dolore erat ea facidunt vel ullaorperos dolore te el ulla feuisisl
1700
10050
Signs may be door fixed or wall fixed (opening side) as above. Either option should be consis-tent throughout a building.
5.07 | A4 Notice Holder D8
Type D8 notice holders are for all rooms where
external notices are displayed.
The signs feature a hinged acrylic face with hidden
magnetic locking pin and surface printed graphics.
Signs should always be mounted at a height of
1700mm to top of sign unless there is an obvious
door furniture feature to align to at a similar height.
Signs bonded to glass doors require a black vinyl
blank for rear of glazing to hide adhesive.
Templates for branded A4 notices can be found on:
www.lancaster.ac.uk/current-staff/communications-
toolkit/templates
Signs bonded to glass doors require black vinyl
backing on rear of glazing to hide adhesive.
Construction principles - 6mm modular painted
aluminium door sign system with hinged acrylic face,
hidden locking pin and printed graphics.
Size_260 x 420mm
18
20
12
Training Room 1 Training Room 1
50LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 5.0 DOOR SIGNS
Stairs toLevels B, C & D
16
15
180
12
12
16
16
24
24
22
22
18
18
C/L
Sign type D9b
Sign type D9a
165
1700
10050
Signs may be door fixed or wall fixed (opening side) as above. Either option should be consis-tent throughout a building.
5.08 | Stairwell Signs D9
Sign type D9 is for stair or lift lobbies to identify
access points to other floors.
A large symbol should always be included at the top
of the sign with text beneath to highlight which floors
are accessible
Signs should always be mounted at a height of
1700mm to top of sign unless there is an obvious
door feature to align with at a similar height.
Construction principles - 6mm modular, painted
aluminium door sign system with printed graphics.
Size_180 x 180mm Stairs toLevels B, C & D
Stairs toLevels B, C & DLifts to
Levels B, C & D
51LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 5.0 DOOR SIGNS
18
35
35
sign type D10a
sign type D10b
A25
A26d1
A26d2
1700
50
50
Signs may be door fixed or wall fixed (opening side) as above. Either option should be consis-tent throughout a building.
5.09 | Door Tags D10
Sign type D10 is a circular tag that allows
the Facilities Team to identify every door
within a building. The tags must always align
to the University’s room numbering policy.
When a room has more than one entrance each
door should be independently identified using a
D10b door tag.
Signs should always be positioned at the top of the
door, 50mm in from the corner.
Construction principles - 2mm silver anodised
aluminium roundel with bevelled edge and
engraved and infilled text.
Size_35 x 35mm
A25d1
52LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 5.0 DOOR SIGNS
5.10 | Graphics CD
The Graphics CD software contains templates
for each type of door sign which enables you to
produce paper inserts to a professional standard
with minimum effort.
Note - please contact Facilities Marketing and
Communications Manager in the Facilities team for
a copy of the Graphics CD.
Graphics CD to include a library of statutory symbols - laboratory signs
CD to include templates for all insert door signs Final output is an A4 print with trim marks for each insert
riser symbols
First Person
First Person
First Person
First Person
53LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 6.0 SIGN ORDERING
6.00 | Sign Ordering Process
The Lancaster University Sign Guidelines are
available for download on the University Intranet
for Building Managers (and others) to use when
ordering signs.
It is the responsibility of the Lancaster University
sign supplier to monitor individual requests from end
users to ensure that only the approved sign types,
appearing within the sign guidelines are ordered.
Any requests by end users for deviations from the
approved standard are to be avoided and ultimately
passed to the Lancaster University Supervising
Officer for determination, if necessary.
1) Initial Enquiry
It is the responsibility of the sign supplier to
provide individual, full colour illustrated scheduling
and quotation services for every enquiry; and site
surveys when requested.
Each enquiry may vary in size from one door sign
to several external signs or internal directories for a
building. Upon receipt of each enquiry a schedule
and quotation must be provided by the sign supplier
within 3 working days.
2) Amendments to Enquiries
End user amendments to a draft illistrated
schedule should not take the sign supplier longer
than 3 working days to update. This schedule and
quotation service, within these 3 day timescales, is
a fundamental part of our Service Ethos and we
shall monitor the performance levels achieved by
the sign supplier.
3) Order Approval
Following an official order number, the sign supplier
must provide the fully manufactured and installed
signs within approximately 20 working days.
Any large or complex orders, where manufacturing
may take longer, are to be highlighted by the sign
supplier at the initial enquiry stage; but these would
not normally be expected to take longer than 25
working days. The client will monitor the
performance levels achieved.
4) Reporting
The sign supplier is required to maintain a monthly
log in the form of a spreadsheet, which highlights the
following information:
• Date of each enquiry received
• Brief description of work to be undertaken
• Date of submission of schedule and quote
• Dates of submission of revised costs etc
• Date of order
• Date of installation and final order completion
The completed log to be submitted to the
Universities Supervising Officer, electronically
on the last calender day of each month.
On a regular basis, the Supervising Officer will
request a meeting with the sign supplier, to
discuss Service Levels achieved and individual
queries and issues arising.
To assist Building Managers (and others) in
ordering signs order form templates are provided
on the following pages.
54LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 6.0 SIGN ORDERING
type arrow content location symbols qty comment
In4 ~ Rooms A01 - A31 lift 1 directional
~ Instrument Laboratory -
~ Toilets m / f / a
In6 - Lecture Theatre above door - 1 150mm max ht
In8 - Instrument Laboratory above reception desk - 1 d.sided suspended
In2 - Rooms A01 - A31 - 1 level A directory
Centre for Lifelong Learning - Line 1
Research & Knowledge Exchange - “ 2
Residences (Facilities) - “ 3
Toilets m / f / a “ 4
contact - MR A N OTHER
building - Faraday Buildinglevel - A
6.01 | FORM A_Wayfinding Signs
55LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 6.0 SIGN ORDERING
type room no. line 1 / line 2 symbols qty comments
D1 A01 LV Switch - 1
“ A02 - - 1
“ A03 Cleaner’s Store - 1
D2 A04 Male toilets male 1
D3 A05 Office - Mr A N Other - 1
“ A06 Office - Mr A N Other - 1
D6 A08 Laboratory L1, L2, L3 2
contact - MR A N OTHER
building - Faraday Buildinglevel - A
6.02 | FORM B_Door Signs
56LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 7.0 DRAWINGS
7.00 | Technical Drawings
The following pages provide construction detail
for external signs. The purpose of the drawings
are as follows:
• Ensure long term consistancy
• Deliver long term quality and durability
• Offer sustainable materials
• Allow for adaptation and change
These drawings show design intent only. Engineering
intent and structural statements to be prepared by
approved sign manufacturer for review and approval
by Lancaster University.
57LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 7.0 DRAWINGS
DIMENSIONS ARE IN mm
TO 2 DECIMAL PLACES
DRAWING NAME Landmark_Entrance Mono
DRAWING NO. LAdwg_MO_L01
DRAWN
CHECKED Copyright c WSi 30.10.12-
DB 30.01.12
-
FINISH
REV.
NAME DATE
00
aluminium / mild steel
-
TOLERANCES +/- 0.2mm
MATERIAL COMMENTS - all surfaces front & rear to be painted using 2-pac high solids paint system and clear hard lacquer finish & i-line ‘x’ guard, label/graffiti protection system or similar
- all steel parts to be hot-dipped glavanised
- ALL part and foundation specifications subject to full review by Structural Engineer
estimated
foundation size:
5x1.2x1.2m = 7.2m3
frame manufactured in two parts with 240x100mm folded aluminium ‘U’ section.
U section to be resin anchored onto concrete foundations to provide additional support to posts
163mm shs aluminium box section (3mm wall) welded to ‘U’ section frame to slot frame over
150mm square mild steel fixing posts
4mm aluminium cladding panels with folded, welded and dressed returns. Secure to frame through
top return only using stainless steel countersunk security fixings
folded aluminium joggle brackets bonded to inside of cladding panels hook into
horizontal ‘U’ section
20mm diameter mild steel ragbolt cage. Hot dip galvanise.
Built up logo with 60mm returns spaced using 20mm clear acylic (no spacer barrels to protect against vandalism)
with LED halo illumination
1
2
3
4
5
6
Resin bound gravel surround with stainless steel frame7
125
125
5
7
1
3
2
4
6
1500 1500 1500
2700
900
900
7575
4500
7.01 | Main Entrance Sign EX1
NEW LOGO TBC
58LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 7.0 DRAWINGS
140 50 140
30013001300 1300300
DIMENSIONS ARE IN mm
TO 2 DECIMAL PLACES
DRAWING NAME Landmark Sign_L4 flex face (A6)
DRAWING NO. LAdwg_LM_F02
DRAWN
CHECKED Copyright c WSi 30.10.12-
DB 30.01.12
-
FINISH
REV.
NAME DATE
00
aluminium / mild steel
-
TOLERANCES +/- 0.2mm
MATERIAL COMMENTS - all surfaces front & rear to be painted using 2-pac high solids paint system
- all steel parts to be hot-dipped glavanised
- ALL part and foundation specifications subject to full review by Structural Engineer
GL
140
3
5
4
6
1
2
extruded aluminium flex face box
heavy duty PVC tensioned skin with digitally printed graphics
extruded aluminium flex face frame constructed in x2 parts
100x25mm mild steel frame fabricated in two sections and bolted
together at site. Hot dip galvanised
140mm mild steel posts with 8mm wall welded to 500x500x40mm feet
and chamfered top face (30degrees), all parts to be hot dip galvanised
38mm mild steel fabricated rag bolt cages bolted to post feet
and sunk into concrete foundations
1
2
3
4
5
6
4500
2900
1800
estimated
foundation size:
EX3a - 5.5x1.5x1.2m = 9.9m3
7.02 | Campus Perimeter EX3
59LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 7.0 DRAWINGS
140 50 140
50012501250500
DIMENSIONS ARE IN mm
TO 2 DECIMAL PLACES
DRAWING NAME Landmark Sign_L4 flex face (A6)
DRAWING NO. LAdwg_LM_F02
DRAWN
CHECKED Copyright c WSi 30.10.12-
DB 30.01.12
-
FINISH
REV.
NAME DATE
00
aluminium / mild steel
-
TOLERANCES +/- 0.2mm
MATERIAL COMMENTS - all surfaces front & rear to be painted using 2-pac high solids paint system
- all steel parts to be hot-dipped glavanised
- ALL part and foundation specifications subject to full review by Structural Engineer
GL
140140140
3
5
4
6
1
2
extruded aluminium flex face box
heavy duty PVC tensioned skin with digitally printed graphics
extruded aluminium flex face frame constructed in x2 parts
100x25mm mild steel frame fabricated in two sections and bolted
together at site. Hot dip galvanised
140mm mild steel posts with 8mm wall welded to 500x500x40mm feet
and chamfered top face (30degrees), all parts to be hot dip galvanised
38mm mild steel fabricated rag bolt cages bolted to post feet
and sunk into concrete foundations
1
2
3
4
5
6
3500
2200
1800
estimated
foundation size:
EX3b - 4.5x1.2x1.2m = 6.5m3
7.03 | Campus Perimeter EX3
60LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 7.0 DRAWINGS
600
600
1270 330
15
GL
1200
800
100 10
100 100 3301070
DIMENSIONS ARE IN mm
TO 2 DECIMAL PLACES
DRAWING NAME Pedestrian Post and Panel Map
DRAWING NO. LAdwg_PM_P01
DRAWN
CHECKED Copyright c WSi 30.10.12-
DB 20.02.12
-
FINISH
REV.
NAME DATE
02
aluminium
-
TOLERANCES +/- 0.2mm
MATERIAL COMMENTS all surfaces front & rear to be painted using 2-pac high solids paint system
security fixings to be colour matched to panel return
upright posts to include 3mm radius on all vertical edges
750
100x100mm shs
aluminium post
with welded and
dressed cap.
Post to extend
750mm below
ground level.
5x30mm locking
grub screws
(top and bottom)
100x100mm shs aluminium brace welded to upright post
8mm aluminium
strap riveted
to face of x2 postsand x2 horiz. braces
1600x1200x10mm
aluminium panel
with machined
recess on rear to
lock flush onto
upright postsand horiz. braces
foundation size (per leg):
600x600x900mm
upright posts
to have 3mm
radius on all
edges
15
7.04 | Campus Map (Post) EX4
61LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 7.0 DRAWINGS
800
150
150
150
150
8080 1340
20
1400
500/
750
80
DIMENSIONS ARE IN mm
TO 2 DECIMAL PLACES
DRAWING NAME Pedestrian Directional Post&Panel
DRAWING NO. LAdwg_PD_PP01
DRAWN
CHECKED Copyright c WSi 30.10.12-
DB 30.01.12
-
FINISH
REV.
NAME DATE
00
aluminium
-
TOLERANCES +/- 0.2mm
MATERIAL COMMENTS all surfaces front & rear to be painted using 2-pac high solids paint system
security fixings to be colour matched to post cap
upright posts to include 3mm radius on all vertical edges
500/750
foundation size (per leg):
a) height < 1750mm
500x500x800mm
b) height > 1750mm
750x750x1000mm
upright posts
to have 3mm
radius on all
edges
countersunk & colour
matched stainless steel
security fixings
extruded heavy duty
aluminium post (STAX)
600mm below ground
level into concrete
foundations
extruded aluminium
channel locks into
upright post
(no pastic parts)
4mm painted
aluminium cap locks
panels in place
using st.steel
security fixings
double sided
20mm extruded
aluminium panels
with internal
strengthening supports
extruded aluminium
infill strip (colour
matched to post)
GL
600
7.05 | Directional (Post) EX7
62LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 7.0 DRAWINGS
38x50x3mm
aluminium angle
screw fixed to wall
DIMENSIONS ARE IN mm
TO 2 DECIMAL PLACES
DRAWING NAME Pedestrian Directional Tray Sign
DRAWING NO. LAdwg_PD_TR01
DRAWN
CHECKED Copyright c WSi 30.10.12-
DB 30.01.12
-
FINISH
REV.
NAME DATE
00
aluminium / polystyrene
-
TOLERANCES +/- 0.2mm
MATERIAL COMMENTS all surfaces front & rear to be painted using 2-pac high solids paint system
security fixings to be colour matched to panel return
all folded returns to have 3mm radius
38mm thick impact
resistant polystyrene
block to be fitted to
inside face of each tray sign
3mm aluminium tray sign with
45mm folded, welded and
dressed returns. Secure along
top and bottom returns. All painted detail to extend around return edges of each sign.Block vinyl banding prohibited, onlyletters and arrows to be applied vinyl.
countersunk & colour
matched stainless steel
security fixings
(top and bottom)
vario
us
45
1000
230 23023040 230 40
7.06 | Directional (Wall) EX8
63LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 7.0 DRAWINGS
90mm diametermild steel post with3mm wall, painted finish as specified and colour matched caps
885
1516
00
600
500R60R60
90
DIMENSIONS ARE IN mm
TO 2 DECIMAL PLACES
DRAWING NAME Car Park Post Sign (large)
DRAWING NO. LAdwg_CP_LP01
DRAWN
CHECKED Copyright c WSi 30.10.12-
DB 30.01.12
-
FINISH
REV.
NAME DATE
00
aluminium / mild steel
-
TOLERANCES +/- 0.2mm
MATERIAL COMMENTS all surfaces to be deburred unless otherwise specified
750
750
extruded sign channel
that allows sign to be
secured to 90mm post
using stainless steel
straps and clips.
Heavy duty channel to be countersunk
riveted to aluminium panel.
3mm aluminium panel
with rolled vertical edges
(45mm radius). All surfaces front and rear to be painted to specified colour
foundation size:
750x750x1000mm
1000
GL
90
7.07 | Car Park Gateway EX12
64LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 7.0 DRAWINGS
extruded sign channel
that allows sign to be
secured to existing lamp
columns using stainless
steel straps and clips.
Heavy duty channel to be
countersunk riveted to aluminium panel. All surfaces front and rear to be painted in specified colours
450
600
100
100
R45
DIMENSIONS ARE IN mm
TO 2 DECIMAL PLACES
DRAWING NAME Car Park Post Sign (small)
DRAWING NO. LAdwg_CP_SP01
DRAWN
CHECKED Copyright c WSi 30.10.12-
DB 30.01.12
-
FINISH
REV.
NAME DATE
00
aluminium
-
TOLERANCES +/- 0.2mm
MATERIAL COMMENTS all surfaces to be painted using automotive system
3mm aluminium panel
with rolled vertical edges
(45mm radius).
7.08 | Parking Bay EX13 / EX14
65LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 7.0 DRAWINGS
A
3mm aluminium tray panels with
fully folded, welded and dressed
returns. Hook onto to frame and
secure using x2 security fixings in
top face. All painted detail to extend around return edges of each sign.Block vinyl banding prohibited, onlyletters and arrows to be applied vinyl.
3mm aluminium folded joggle
bracket bonded to inside face
of tray panel
700
1800
100
20
575
100
100
400
100
500
100
250
100 GL
25
75 75
250
250330250
3019
030
30 190 30 20
A (1 : 6)
DIMENSIONS ARE IN mm
TO 2 DECIMAL PLACES
DRAWING NAME Pedestrian Directional Totem
DRAWING NO. LAdwg_PD_T01
DRAWN
CHECKED Copyright c WSi 30.10.12-
DB 30.01.12
-
FINISH
REV.
NAME DATE
00
aluminium
-
TOLERANCES +/- 0.2mm
MATERIAL COMMENTS all surfaces front & rear to be painted using 2-pac high solids paint system
security fixings to be colour matched to panel return
all folded returns to have 3mm radius
3mm aluminium folded ‘U’
section ribs bonded to frame
to locate joggle brackets
20mm thru holes to allow sign to
be chemically anchored to
concrete foundation
welded aluminium lugs with
drilled and tapped holes to
locate security fixings (detail A)
100x100mm shs aluminium frame
with 20mm welded plate feet. Painted on all surfaces.
countersunk & colour matched
stainless steel security fixings
foundation size:
1100x600x600mm
7.09 | Accessible Totem EX15
66LANCASTER UNIVERSITY | SIGNAGE DESIGN GUIDELINES | V1.12 8.0 MAINTENANCE
8.00 | Annual Sign Maintenance
All external campus signage should be
refurbished annually to ensure a high quality
finish is maintained.
The appointed sub-contractor will be required to
clean all signs to a professional standard, remove all
tape and graffiti and check lighting performance. A
guide to best practice is detailed across the page.
In addition, signs located in areas of campus
susceptible to vandalism should be covered in a
non-visible, anti-graffiti coating and a separate cost
should be provided by the appointed sub-contractor
for supplying this service.
All cleaned signs should be photographed and a
photographic record provided to the University. A
separate report should detail all damage to
existing signs and highlight all repair costs.
This exercise should be completed during
the summer holiday months of July and August.
Cleaning Instructions
Exterior signs are painted aluminium panels with self
adhesive vinyl applied to the surfaces. Therefore,
for best cleaning results, use a proprietary car
shampoo and warm water only.
Never use methylated spirit, polish, white spirit, turps
or any other agressive solvent.
Always use a clean soft lint-free cloth.
Graffiti/Tape Removal Instructions
For removal of vinyl or tape use a proprietary 3M
vinyl removal agent.
For removal of graffiti, apply mild panel wipe solution
to a clean soft lint-free cloth and rub gently . To
avoid dulling the gloss lacquers do not rub too hard.