signature hinged door (125mm)

13
Installation Details Signature Hinged Door (125 m m )

Upload: others

Post on 08-May-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Signature Hinged Door (125mm)

Installation Details

SignatureHinged Door(125mm)

Page 2: Signature Hinged Door (125mm)

THICKNESS TO SUIT(BY BUILDER - 300mm LENGTH)

CAVITY FIXING PACKER

(BY BUILDER)

STEEL LINTEL

TIMBER LINTEL

SARKING

SEALANT

HEAD FLASHING

(DO NOT PACK FIXING)

REVEAL TO SUIT

10mm MIN. CLEARANCE

(BY BUILDER - SEE NOTE)HEAD REVEAL FIXING

(BY BUILDER)

JAMB STUD

JAMB FLASHING

(BY BUILDER - AT FIXING POINTS)JAMB PACKER TO SUIT

(BY BUILDER - SEE NOTE)AT HINGE POINTS & CENTRES TO SUIT

NOTE:

JAMB REVEAL FIXING

300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE ATFOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT

2.2mm STEEL NAIL MIMIMUM.

(200mm LENGTHS - AT HINGE POINTS)EXTENDER FIN 100BA543 (3964)

(BY BUILDER - 1 PER HINGE)

(BY BUILDER - 2 PER FIN EXTENDER)

ARCHITRAVE

INTERIOR LINING

10G x 65mm SCREWFIN EXTENDER FIXING

(2 PER FIN EXTENDER)SCREW SQ 10G x 1.18 WAFER SD SS #283761

ADDITIONAL HINGE FIXINGREMOVE EXISTING & RELACEWITH 10G x 100mm SCREW

HINGE TO SUIT

SIG-HD-02-01 B

Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

ABN 78 010 409 819

SIG 125 HD

CDJH 1 : 3

COPYRIGHT 2017

PRODUCT NO:

SCALE:

DRAWING NO:

DRAWN:

DATE:

ISSUE:

01/02/17

BRICK VENEER CONSTRUCTION - OPEN IN - HEAD & JAMB DETAIL

Signature Hinged Door (125mm )Installation Details

02-01

Page 3: Signature Hinged Door (125mm)

(BY BUILDER - 1 PER HINGE)

NOTE:

300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT

2.2mm STEEL NAIL MIMIMUM.

(BY BUILDER)JAMB FLASHING

(BY BUILDER)

BRICKWORK

REVEAL TO SUIT

SILL FLASHING

(AS PER B.C.A.)

FOOTING

DRAIN SLOTS

(NON-SHRINKING)

INTERNAL FLOOR FINISH

SEALANT

GROUT

(BY BUILDER - AT FIXING POINTS)JAMB PACKER TO SUIT

FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT

(BY BUILDER - SEE NOTE)AT HINGE POINTS & CENTRES TO SUITJAMB REVEAL FIXING

(BY BUILDER - 300mm LENGTH)THICKNESS TO SUITCAVITY FIXING PACKER

(2 PER FIN EXTENDER)SCREW SQ 10G x 1.18 WAFER SD SS #283761

(200mm LENGTHS - AT HINGE POINTS)EXTENDER FIN 100BA543 (3964)

(BY BUILDER - 2 PER FIN EXTENDER)10G x 65mm SCREWFIN EXTENDER FIXING

ADDITIONAL HINGE FIXINGREMOVE EXISTING & RELACEWITH 10G x 100mm SCREW

HINGE TO SUIT

B

Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

ABN 78 010 409 819 COPYRIGHT 20171 : 3

SIG 125 HD

DRAWN:

DRAWING NO:

PRODUCT NO:

SCALE:C

ISSUE:

DATE:

DJH

SIG-HD-02-02

01/02/17

BRICK VENEER CONSTRUCTION - OPEN IN - SILL & JAMB DETAIL

Signature Hinged Door (125mm )Installation Details

02-02

Page 4: Signature Hinged Door (125mm)

450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT

SARKING

(200mm LENGTHS - AT HINGE POINTS)

300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.

EXTERIOR CLADDING

TIMBER LINTEL

EXTERIOR TRIM

HEAD FLASHING(BY BUILDER)

BA543 (3964)EXTENDER FIN 100

(DO NOT PACK FIXING)

REVEAL TO SUIT

INTERIOR LINING

ARCHITRAVE

JAMB STUD

10mm MIN. CLEARANCE

FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT

(BY BUILDER - SEE NOTE)AT HINGE POINTS & CENTRES TO SUIT

(BY BUILDER - SEE NOTE)

HINGE TO SUIT

HEAD REVEAL FIXING

JAMB REVEAL FIXING

NOTE:

(BY BUILDER - 1 PER HINGE)WITH 10G x 100mm SCREW

(BY BUILDER - AT FIXING POINTS)JAMB PACKER TO SUIT

(BY BUILDER)JAMB FLASHING

REMOVE EXISTING & RELACE

(BY BUILDER - 2 PER FIN EXTENDER)10G x 65mm SCREWFIN EXTENDER FIXING

ADDITIONAL HINGE FIXING

83761SCREW SQ 10G x 1.18 WAFER SD SS #2(2 PER FIN EXTENDER)

B

Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

ABN 78 010 409 819 COPYRIGHT 20171 : 3

ESS 100 HD

DRAWN:

DRAWING NO:

PRODUCT NO:

SCALE:C

ISSUE:

DATE:

DJH

ESS-HD-02-03

01/02/17

CLADDING CONSTRUCTION - OPEN IN - HEAD & JAMB DETAIL

Signature Hinged Door (125mm )Installation Details

02-03

Page 5: Signature Hinged Door (125mm)

ISSUE:SIG-HD-02-04 B

Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

C COPYRIGHT 2016

DATE:SIG 125 HD

ABN 78 010 409 819

PRODUCT NO:

SCALE: 1 : 3DJHDRAWN:

DRAWING NO:

20/09/16

CLADDING CONSTRUCTION - OPEN IN - SILL & JAMB DETAIL

BA543 (3964)EXTENDER FIN 100

2.2mm STEEL NAIL MIMIMUM.450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT

(200mm LENGTHS - AT HINGE POINTS)

INTERNAL FLOOR FINISH

(AT FIXING POINTS)

HINGE TO SUIT

(BY BUILDER - 2 PER FIN EXTENDER)

(BY BUILDER)

FOOTING

(BY BUILDER)

300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A

SEALANT

(BY BUILDER)

SILL FLASHING

GROUT

EXTERIOR TRIM

JAMB REVEAL FIXING

(BY BUILDER - SEE NOTE)AT HINGE POINTS & CENTRES TO SUIT

10G x 65mm SCREWFIN EXTENDER FIXING

JAMB PACKER

SILL SUPPORT

FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE ATNOTE:

(BY BUILDER - 1 PER HINGE)WITH 10G x 100mm SCREWREMOVE EXISTING & RELACEADDITIONAL HINGE FIXING

83761SCREW SQ 10G x 1.18 WAFER SD SS #2(2 PER FIN EXTENDER)

Signature Hinged Door (125mm )Installation Details

02-04

Page 6: Signature Hinged Door (125mm)

B

Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

ABN 78 010 409 819 COPYRIGHT 20171 : 3

SIG 125 HD

DRAWN:

DRAWING NO:

PRODUCT NO:

SCALE:C

ISSUE:

DATE:

DJH

SIG-HD-02-05

01/02/17

CAVITY BRICK CONSTRUCTION - OPEN IN - HEAD & JAMB DETAIL

300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.

(BY BUILDER)HEAD FLASHING

INTERNAL LINING ADHESIVE

STEEL LINTEL

(BY BUILDER)JAMB FLASHING

INTERNAL LINING

(TO PINCH FIN)

BRICKWORK

NOTE:FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT

HINGE TO SUIT

86716TIE BRICK FLAT CAVITY SIG LASEROR85856TIE FLAT BRICK 100/166(AT COURSE NEAREST HINGE &EVERY FOURTH COURSE MAX.)

86716 (TRIMMED)TIE BRICK FLAT CAVITY SIG LASER(AT COURSE NEAREST HINGE &EVERY FOURTH COURSE MAX.)

Signature Hinged Door (125mm )Installation Details

02-05

Page 7: Signature Hinged Door (125mm)

1 : 3

DRAWING NO: ISSUE:SIG-HD-02-06 B

DJH Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

ABN 78 010 409 819 COPYRIGHT 2017

PRODUCT NO:

SCALE:C

DRAWN:

DATE:SIG 125 HD 01/02/17

CAVITY BRICK CONSTRUCTION - OPEN IN - SILL & JAMB DETAIL

FOOTING

INTERNAL LINING ADHESIVE

SILL FLASHING

(NON-SHRINKING)

(BY BUILDER)

BRICKWORK

(AS PER B.C.A.)

(BY BUILDER)

450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT

ARCHITRAVE

SEALANT

DRAIN SLOTS

INTERNAL LINING

JAMB FLASHING

2.2mm STEEL NAIL MIMIMUM.300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A

INTERNAL FLOOR FINISH

NOTE:FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT

GROUT

HINGE TO SUIT

86716TIE BRICK FLAT CAVITY SIG LASEROR85856TIE FLAT BRICK 100/166(AT COURSE NEAREST HINGE &EVERY FOURTH COURSE MAX.)

86716 (TRIMMED)TIE BRICK FLAT CAVITY SIG LASER(AT COURSE NEAREST HINGE &EVERY FOURTH COURSE MAX.)

Signature Hinged Door (125mm )Installation Details

02-06

Page 8: Signature Hinged Door (125mm)

B

Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

ABN 78 010 409 819 COPYRIGHT 20171 : 3

SIG 125 HD

DRAWN:

DRAWING NO:

PRODUCT NO:

SCALE:C

ISSUE:

DATE:

DJH

SIG-HD-02-07

01/02/17

BLOCKWORK CONSTRUCTION - OPEN IN - HEAD & JAMB DETAIL

(SEAL TO OPENING & FRAME)

300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.

(SEE NOTE)

REINFORCING BAR

BLOCKWORK

(INISDE ANGLE ONLY - SEE NOTE)

AND FREE FROM ANY CONTAMINANTS BEFORE SEALING.

HEAD ANGLE FIXINGS ATREQUIRED CENTRES

HINGE TO SUIT

SEALANT

ANGLE 40 x 25 x 2.7mmBX336 (2304)

INTERNAL LINING ADHESIVE

450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE ATFOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT

ANCHOR FIXING

INTERNAL LINING

ANGLE 25 x 20 x 1.5(SEAL TO OPENING & FRAME)

BX123 (2369)

(SEE NOTE)

NOTE:SURFACE OF BLOCKS TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TOPREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRY

JAMB ANGLE FIXINGS ABOVE& BELOW HINGE LOCATIONSAND AT REQUIRED CENTRES(SEE NOTE)

Signature Hinged Door (125mm )Installation Details

02-07

Page 9: Signature Hinged Door (125mm)

BX336 (2304)

(SEE NOTE)

FOR SITE CLASSIFICATIONS OF UP TO AND INCLUDING 'N6' OR SIMILAR, FIXINGS ARE TO BE AT

BX123 (2369)ANGLE 25 x 20 x 1.5(SEAL TO OPENING & FRAME)

AND FREE FROM ANY CONTAMINANTS BEFORE SEALING.

300mm CENTRES MAXIMUM. FIXING SIZE TO BE EQUIVALENT TO A 2.2mm STEEL NAIL MIMIMUM.

INTERNAL LINING

ANGLE 40 x 25 x 2.7mm

(INISDE ANGLE ONLY - SEE NOTE)

INTERNAL LINING ADHESIVE

450mm CENTRE MAXIMUM, FOR SITUATIONS IN EXCESS OF THIS THE FIXINGS ARE TO BE AT

(SEE NOTE)

REINFORCING BAR

BLOCKWORK

FOOTING

INTERNAL FLOOR FINISH

(NON-SHRINKING)

(SEAL TO OPENING & FRAME)

ANCHOR FIXING

GROUT

SEALANT

(AS PER B.C.A. SEE BELOW)TANKING ON ALL OPENING SURFACES

NOTE:SURFACE OF BLOCKS TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TOPREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRY

JAMB ANGLE FIXINGS ABOVE& BELOW HINGE LOCATIONSAND AT REQUIRED CENTRES

HINGE TO SUIT

ISSUE:SIG-HD-02-08 B

Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

C COPYRIGHT 2017

DATE:SIG 125 HD

ABN 78 010 409 819

PRODUCT NO:

SCALE: 1 : 3DJHDRAWN:

DRAWING NO:

01/02/17

BLOCKWORK CONSTRUCTION - OPEN IN - SILL & JAMB DETAIL

Signature Hinged Door (125mm )Installation Details

02-08

Page 10: Signature Hinged Door (125mm)

1 : 3

DRAWING NO: ISSUE:SIG-HD-02-09 B

DJH Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

ABN 78 010 409 819 COPYRIGHT 2017

PRODUCT NO:

SCALE:C

DRAWN:

DATE:SIG 125 HD 01/02/17

CONCRETE CONSTRUCTION - OPEN IN - HEAD & JAMB DETAIL

ANGLE 25 x 20 x 1.5

BX336 (2304)

INTERNAL LINING

(SEAL TO OPENING & FRAME)

PREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRY

ANGLE 40 x 25 x 2.7mm

(SEE NOTE)

(SEAL TO OPENING & FRAME)

BX123 (2369)

HEAD ANGLE FIXINGS ATREQUIRED CENTRES

SURFACE OF CONCRETE TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TO

CONCRETE PANEL

FIXING TYPES & CENTRES TO BE PROJECT SPECIFIC, REFER TO SPECIFICATION AND/OR ENGINEEER.

AND FREE FROM ANY CONTAMINANTS BEFORE SEALING.

INTERNAL LINING ADHESIVE

HINGE TO SUIT

NOTE:

(SEE NOTE)

JAMB ANGLE FIXINGS ABOVE& BELOW HINGE LOCATIONSAND AT REQUIRED CENTRES(SEE NOTE)

Signature Hinged Door (125mm )Installation Details

02-09

Page 11: Signature Hinged Door (125mm)

PREVENT INGRESS OF MOISTURE. ENSURE SURFACES TO BE SEALED ARE SOUND, CLEAN, DRY

NOTE:SURFACE OF CONCRETE TO WINDOW OPENING MUST BE TANKED WITH A SUITABLE SEALER TO

INTERNAL LINING ADHESIVE

PACKER

(INSIDE ANGLE ONLY - SEE NOTE)

HINGE TO SUIT

BX123 (2369)

FIXING TO SUIT

FIXING TYPES & CENTRES TO BE PROJECT SPECIFIC, REFER TO SPECIFICATION AND/OR ENGINEEER.

AND FREE FROM ANY CONTAMINANTS BEFORE SEALING.

BACKING ROD

ANGLE 40 x 25 x 2.7mm

SUBSILL '15' 100

INTERNAL LINING

BX336 (2304)

(SEAL TO OPENING & FRAME)

ANCHOR FIXING

ANGLE 25 x 20 x 1.5(SEAL TO OPENING & FRAME)

SILL SEALED TO SUBSILL

SEAL SUBFRAME

URETHANE SEALANT

CONCRETE PANEL

83353

(SEE NOTE)

BE015 (3353)

(SEAL OVER FIXING HEAD - SEE NOTE)

JAMB ANGLE FIXINGS ABOVE& BELOW HINGE LOCATIONSAND AT REQUIRED CENTRES(SEE NOTE)

ISSUE:SIG-HD-02-10 B

Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

C COPYRIGHT 2017

DATE:SIG 125 HD

ABN 78 010 409 819

PRODUCT NO:

SCALE: 1 : 3DJHDRAWN:

DRAWING NO:

01/02/17

CONCRETE CONSTRUCTION - OPEN IN - SILL & JAMB DETAIL

Signature Hinged Door (125mm )Installation Details

02-10

Page 12: Signature Hinged Door (125mm)

(FIT INTO SUBSILL BEFORE FIXING)

TANKING APPLIED TO OPENING SURFACE

SUBSILL FIXING

PACKING AT FIXING POINTS

DAM ANGLE TO SUIT

(TYPE & QUANTITY PROJECT SPECIFIC)

1. INSTALL SUBSILL INTO OPENING WITH DAM ANGLE FITTED. PACK SUBSILL LEVELTHEN FIX TO STRUCTURE. SEAL SUBSILL ENDS TO STRUCTURE.

(BY BUILDER)

SUBSILL TO SUIT(SEAL ENDS TO OPENING)

1 : 4

DRAWING NO: ISSUE:SIG-HD-02-11 A

DJH Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

ABN 78 010 409 819 COPYRIGHT 2012

PRODUCT NO:

SCALE:C

DRAWN:

DATE:SIG 125 HD 20/11/12

SUBSILL DAM ANGLE INSTALLATION

(SEAL TO OPENING & SUBSILL)

SEAL ALL JOINTS BETWEEN ANGLE AND SUBSILL. SEAL OVER FIXINGS AND UNDER SUB SILL TO STRUCTURE.

BACKING ROD

SEAL OVER FIXINGS

DAM ANGLE TO SUIT

SEAL

2.APPLY SEALANT TO VERTICAL FACE OF DAM ANGLE AND ALSO TO THE FLOOR OF THE SUBSILL.POSITION DAM ANGLE AGAINST STRUCTURE. SEAL ALL JOINTS BETWEEN ANGLE AND SUBSILL.

TANKING APPLIED TO OPENING SURFACE(BY BUILDER)

Signature Hinged Door (125mm )Installation Details

02-11

Page 13: Signature Hinged Door (125mm)

BX336 (2304)ANGLE 40 x 25 x 2.7mm(FIXING ANGLE - SEAL TO OPENING & WINDOW)

Q2481 (2111)ANGLE 25 x 20 x 1.4(TRIM ANGLE - SEAL TO OPENING & WINDOW)

BE015 (3353)SUBSILL '15' 100

83353SEAL SUBFRAME

ANGLE DAM 100(SEAL TO OPENING & SUBSILL)

83611

SILICONE SEAL ALL EXPOSED GAPSBETWEEN SUBSILL, DAM ANGLE & ANGLES

SIG-HD-02-12 A

Phone (07) 3131 3777 Fax (07) 3131 3838136 Zillmere Road, Boondall, Q 4034, Australia

ABN 78 010 409 819

SIG 125 HD

CDJH 1 : 1.5

COPYRIGHT 2012

PRODUCT NO:

SCALE:

DRAWING NO:

DRAWN:

DATE:

ISSUE:

20/11/12

SUBSILL DAM ANGLE INSTALLATION WITHE FIXING & TRIM ANGLES

Signature Hinged Door (125mm )Installation Details

02-12