SIKAGARD®-706 THIXO
Thixotropic consistency, Non-drip Low volatility, Outstanding
penetration Low evaporation, water-based, Low VOC, High alkaline
resistance Freeze and thaw with de-icing
salt stress resistant
Silane based, cream type
May 3, 20233
SIKAGARD®-706 THIXO
Immediately after application 30 minutes after application
Silane based, cream type
Problem-free “overhead” application
Already treated areas are clearly visible
Low operation cost Problem-free cleaning of
equipment Application by airless spray
brush or rollerMay 3, 20234
SIKAGARD®-706 THIXO
Low wastage when working overhead
No visible traces after application
Loss-free application High coverage rates Single step application
up to 400 / 500 g/m²
Silane based, cream type
May 3, 20235
SIKAGARD®-706 THIXO
Silane based, cream type
May 3, 20236 New Product Showcase / BCRAO Skagard 706 Thixo
SIKAGARD®-706 THIXO
Corporate Brochures Technology & Concept, for
Designer & Contractor
Technical ArticlesSika & Third Parties
Technical & Commercial Presentations
Silane based, cream type
Hydrophobic Impregnations
8Marketing & Technical Tools
Technical Articles(Sika & Third Parties)
Corporate Brochures (Technology & Concept, for
Designer & Contractor)
Technical & commercial presentations
9Value Selling for Specifiers
Hydrophobic engineering
Specification support
Supporting documentation
Compatible systems (coatings and corrosion inhibitor)
Sika references
Long term experience (>15 years)
10Value Selling for Contractors
Application engineering
Method statement
Job site support
Testing facilities
Compatible systems (coatings and corrosion inhibitor)
Sika references
11
12
Influence of Cracks[3]
• Objective of the Study:• To show the influence of crack in the effectiveness
of hydrophobic treatment using different types of product (high active content silane liquid or cream, low active content silane/siloxane)
• Summary of the results: Importance of the type of product used in the durability
behaviour Best performance achieved with cream Silane No long term protection achieved with low active
silane/siloxane Effective protection achieved even if the treatment occurs
before the crack appears
13For Different Substrates
Concrete Brick Natural & Artificial Stone
14
15
Standard Tests (Alberta B388)Requirement (example)
Sealer Type Water uptake in % to a control non treated
Before Abrasion After Abrasion
Type 1a 82,5% 75%
Type 1b - 86%
Type 1c - 85%*
Note*: 144 grams abrasion instead of usual 72 grams for type 1a & 1b
16
StandardsCanada (Alberta B388):
Requirements: Reduction of water uptake after surface abrasion Reduction of water uptake after alkali exposure Water vapour transmission Etc.
Other Standards: Quebec Department of Transport MTQ Standard 3601
17
In general, there are three different levels of these Sika protection systems:
System 1:Durable concrete protection
System 2:Durable concrete andreinforcement protection
System 3:High performance protectionfor extreme conditions
Sikagard deep penetratinghydrophobic impregnation
Sika FerroGard corrosion inhibitorSikagard deep penetratinghydrophobic impregnation
Sika FerroGard corrosion inhibitorSikagard deep penetratinghydrophobic impregnationSikagard protective coating
Sika Competence in Complete Concrete Protection
For exposed concrete structuresshowing no visible concrete defects(crack width < 0.3 mm)
For severely exposed or weakconcrete with a high risk of steelcorrosion
For severely exposed or weakconcrete with a high risk of cracking
1
1
2
1
23
12
12
3
1
18
Standard Tests (Alberta B388)Classification:
Type 1: Penetrating sealers for use of traffic bearing exposed to abrasion
Type 1a: for sheltered conditions – relative moisture content of substrate not
exceeding 55% Type 1b: for outdoor condition where the relative
moisture content of substrate not exceeding 70%
Type 1c: low VOC, high performance. For application in outdoor
conditions to new bridges and overlays cast with low water cement ratio
(0,30 – 0,45) where the relative moisture content is maximum 80%