silentium company profile
TRANSCRIPT
![Page 1: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/1.jpg)
Company Overview
Joel(Yoel) Naor, Director of Products
T: +972-8-9468664
C: +972-542-320409
F: +972-8-9468604
Email: [email protected]
www.silentium.com
![Page 2: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/2.jpg)
2 Oct-10
The “Pain”
• Equipment/Products generate Noise
• Noise is Pollution, annoying, harmful and
reduces productivity and “Quality of Life”
• Noisy products are inferior
• Regulations
• Market demand
![Page 3: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/3.jpg)
3 Oct-10
Silentium – Spatial & Broadband Active
Acoustic
Canceling emitted noise by counter noise
• Physics of Spatial Active Acoustics
• DSP – Proprietary Prediction Algorithms
![Page 4: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/4.jpg)
4 Oct-10
Noise Reduction Methodology
Reduces Effectively
Low-frequency noise
Reduces Effectively
High-frequency noise
![Page 5: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/5.jpg)
5 Oct-10
Noise Sources-Spectrum
Air flow spectrum example
Active Noise Control => effective in the low frequency band
Passive absorption => effective in the high frequency band
Broad band Noise => Requires a combination of
Passive and Active Noise Control
![Page 6: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/6.jpg)
6 Oct-10
Technology – Silentium’s ANC
Canceling the emitted noise
at the source
Embedded in Products (OEM&ODM
oriented)
Vs.
Engineering each target zone/space
(Environment)
![Page 7: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/7.jpg)
7 Oct-10
OEM - S-Cube™ Kit
Reference Design
![Page 8: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/8.jpg)
8 Oct-10
Active Acoustics Fields
AVC
Active Vibration Control
S-Cube™SoC - Reference Design
ANC
Active Noise Control
ASAC
Active Structural Acoustic Control
ASAC
Active Structural Acoustic Control
![Page 9: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/9.jpg)
9 Oct-10
Hot Swap ANC- Fan for CRAY CX1
Design Win
![Page 10: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/10.jpg)
10 Oct-10
Blower application example
Blower
Microphone
Speaker
Inlet
![Page 11: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/11.jpg)
11 Oct-10
ActiveSilencer™ Duct
![Page 12: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/12.jpg)
12 Oct-10
AcoustiRACK™ Active - ARA™
• The first rack mount cabinet with ANC- reducing
fan generated noise
• Ideally designed for office environment
• Up to 30dBA reduction
![Page 13: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/13.jpg)
13 Oct-10
- Silentium Remote Site Solution
c3000 with UPS & local KVM in a small 15U (usable) AcoustiRACK™
![Page 14: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/14.jpg)
14 Oct-10
ASE™ for Intel® Modular Server
![Page 15: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/15.jpg)
15 Oct-10
Business Model
Collaborations
with
OEM’s & ODM’s
![Page 16: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/16.jpg)
16 Oct-10
Reference Design Methodology
Acoustic
Development
Mechanical Design Production phase
HW Design (based on
SILENTIUM’s Reference
Design)
S-Cube™ Controller
Gate
Silentium Provides:
1. SCDK™
2. Technical Coaching
Silentium Provides:
1. S-Cube™ Controller \ Reference Design Notes
2. Technical Coaching
Silentium Provides:
1. S-Cube Controller or Silentium
components S/W
2. SEK™ (Calibration units)
3. Technical Coaching
![Page 17: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/17.jpg)
17 Oct-10
Silentium Products
SCK™
S-cube™ Kit
ARA™
AcoustiRACK™ Active
SCDK™
S-cube™ Development Kit
ASFT™
Active Silencer Fan
Tray
ASE™
Acoustic Silencer Enclosure
for Intel® Modular Server
![Page 18: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/18.jpg)
18 Oct-10
The S-Barrier™ Panel
• Components:
• 2 PZTs (sensor + actuator)
• S-Chip™ microcontroller
• Panel: Aramid Honeycomb core with Epoxy Glass Fiber skin
• Thickness: 6 mm
• Weight: 2.3 Kg/m2
• Fire: Fire-resistant and self extinguishing.
• Service Temperature: -20o-90o C
The S-Barrier is aiming at reducing 10 dB(A) structure borne
noise on top of the passive reduction.
![Page 19: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/19.jpg)
19 Oct-10
Applications
Technology/
Market
SegmentationANC ASAC Z-2-Z
Home appliances
IT
Transportation - Ventilation System -Engine noise reduction
- Road/wind noise reduction
Industrial
Quiet
zone
![Page 20: Silentium Company Profile](https://reader031.vdocument.in/reader031/viewer/2022020123/55b550fabb61ebd1438b4594/html5/thumbnails/20.jpg)
20 Oct-10
Thank you!