sinus m

2
Powe ranges: 0.37~7.5Kw 380-480Vac, 3 phase IP20 enclosure IGBT Inverter 2 Control modes: V/F and Sensorless Vector Control Serial port RS 485 with protocol MODBUS RTU Remotable smart keyboard Overload 150% of In for 60 sec. Overload 200% for short time span Maximum torque 180% Cn Maximum output frequency 400Hz MOTOR AUTO TUNING FOR OPTIMUM PERFORMANCE Anti-Stalling and antitrip algorithm 8 speed sets 3 frequency jumps (skip) 8 NPN PNP Programmable digital inputs 2 analog inputs 0-10Vdc and 4-20mA 1 programmable open collector output 1 analog output 0-10Vdc Adjustable carrier 1-10KHz Incorporated braking unit Automatic and manual torque boost Speed search PID function 'S" ramps Fire Mode function Standard Features Full digital 380 - 480 Vac power supply Power range 0,37 - 7,5 5kW Full compatibility with teleservice software, "Remote Drive" on Internet. Options Kit remote keyboard operation (3 meters) EMC filters EN 55011 CL.A1 and B Braking resistors Analog converter V/1 (0/10/4-20mA) Relay for open collector output "Remote Drive" software Converter for MODBUS/Profibus/ DP-CanBus-Device Net etc. RS 485/232 converter Applications Fan Textile machinges Pumps Machines for handling materials Food processing machines Centrifuges Dryers Doors for elevators Industrial washing machines Tooling machinery Grinders Hoist R E M O T E D R I V E

Upload: gianmarco-castillo

Post on 19-Feb-2016

28 views

Category:

Documents


0 download

DESCRIPTION

catalogo del variador

TRANSCRIPT

Page 1: Sinus M

Powe ranges:0.37~7.5Kw 380-480Vac, 3 phaseIP20 enclosureIGBT Inverter2 Control modes: V/F and Sensorless Vector ControlSerial port RS 485 with protocol MODBUS RTURemotable smart keyboardOverload 150% of In for 60 sec.Overload 200% for short time spanMaximum torque 180% CnMaximum output frequency 400Hz

MOTOR AUTO TUNING FOR OPTIMUM PERFORMANCE

Anti-Stalling and antitrip algorithm8 speed sets3 frequency jumps (skip)8 NPN PNP Programmable digital inputs2 analog inputs 0-10Vdc and 4-20mA1 programmable open collector output1 analog output 0-10VdcAdjustable carrier 1-10KHzIncorporated braking unitAutomatic and manual torque boostSpeed searchPID function'S" rampsFire Mode function

Standard Features Full digital 380 - 480 Vac power supplyPower range 0,37 - 7,5 5kWFull compatibility with teleservice software, "Remote Drive" on Internet.

OptionsKit remote keyboard operation (3 meters)EMC filters EN 55011 CL.A1 and B Braking resistorsAnalog converter V/1 (0/10/4-20mA)Relay for open collector output"Remote Drive" softwareConverter for MODBUS/Profibus/DP-CanBus-Device Net etc.RS 485/232 converter

Applications

Fan Textile machinges Pumps Machines for handling materialsFood processing machines CentrifugesDryers Doors for elevatorsIndustrial washing machines Tooling machineryGrinders Hoist

REMOTE

D R I VE

Page 2: Sinus M

AU

T/S

INU

S M

/300

0/JA

N. '

06

RP

/ AU

T/S

INU

S M

/500

0/JA

N '0

8

Power Ratings

Max capacityMotor power380-415 VAC

Outputratings

Inputratings

0001 002 0003 0005 0007 0011 0014

[HP] 0.5 1 2 3 5 7.5 10 [kW] 0.4 0.75 1.5 2.2 4 5.5 7.5 Capacity [kVA] 0.95 1.9 3.0 4.5 6.9 9.1 12.2 Fla [A] 1.25 2.5 4 6 9 12 16 Max Frequency 400[Hz] Max Voltage 3 380 ~ 480 V Rated Voltage 3 380~480 VAC (+10%,-15%) Rated Frequency 50~60 [Hz] (+/-5%) Natural Cooling method convec- Forced cooling tion Weight [kg] 0.76 0.77 1.12 1.84 1.89 3.66 3.66

SINUS M 4TBA2K2

Control

DyanmicBraking

Control method V/F, Sensorless vector control

Frequency setting resolution Digital command: 0.01Hz Analog command: 0.06Hz (Max freq.: 60Hz

Frequency accuracy Digital command: 0.01% of Max output frequency Analog command: 0.1% of Max output frequency

V/F pattern Linear, Squared, User V/F

Overload capacity 150% per 1 min.

Torque boost Manual/Auto torque boost

Max bracking

torque

20% WITH DEACCLERATING RAMP without resistor

Time%ED 150% BY USING EXTERIAL RESISTOR

Operation

Operation mode Keypad / Terminal / Communication option / Remote keypad selectable

Freqency setting Analog : 0 - 10 [V], 10 - 10 [V], 0 - 20 [mA]

Digital: Keypad

Operation features PID, Up-down, 3-wire

NPN / PNP selectable

FWD/REV RUN, Emergency stop, Fault reset, Jog operation, Multi-step Frequency-High, Mid, Low, Multi-step Accel/Decel-High, Mid, Low,

DC braking at stop, 2nd motor select, Frequency UP/Down, 3-wire operation, External trip A,B, PID-inverter (v/f), operation bypass, Analog Hold,

Accel/Decel stop, Up/Down Save Freq.

Fault output and Less than DC 24V 50mA

inverter status output (N.O., N.C.) Less than AC 250V 1A,

Less than DC 30V 1A,

0 ~ 10 Vdc (less than 10mA): Output Freq. Output Current, Output Voltage, DC link selectable

Multi-function terminalP1 ~ P8

Open collector terminal

Multi-function relay

Analog output

Input

Output

Environment

Protection degreee IP 20

Ambient temp -10o C ~ 50o C

Storage temp -20o C ~ 65o C

Humidity Below 90% RH (no condensation)

Altitude/Vibration Below 1,000m. 5.9m/sec2 (0.6G)

Atmospheric pressure 70 ~ 106 kPa

Location Protected from corrosive gas, combustible gas, oil mist or dust

Protective function

Trip Over Voltage, Under Voltage, Over Current, Ground Fault current detection, Inverter

Overheat, Motor Overheat, Output Phase Open, Overload Protection,

Communication Error, Loss of Speed Command, Hardware Fault, Fan trip

Alarm Stall prevention, overload

Momentary Below 15 msec: Continuous operation (should be within rated input voltage, rated ouput power.) Power Loss Above 15 msec: Auto restart enable

4T B A2/X K 2

Input Brake Filter Keypad Enclosure

W H D

kW

power [mm] [mm] [mm]

SINUS M 0001 4T 0.4 3 Phase B= A2= X= K= 2=IP20

70 128 130

SINUS M 0002 4T 0.75 380-480 IN IN EX IN 70 128 130

SINUS M 0003 4T 1.5 VAC C C C C 100 128 130

SINUS M 0005 4T 2.2 L L L L 140 128 155

SINUS M 0007 4T 4.0 U U U U 140 128 155

SINUS M 0011 4T 5.5 D D D D 180 220 170

SINUS M 0014 4T 7.5 E E E E 180 220 170

D D

Dimension

Inverter

0001

Ahmedabad-98256-07601 Bangalore-98455-46105 Bhubaneswar-98610-81767 Chandigarh-98554-87089 Chennai-98402-85500 Cochin-98477-43393 Coimbatore-98430-53555 Faridabad-98180-10700Gurgaon-99101-55464 Guwahati-94354-07024 Hospet-98459-30782 Hubli-98802-90471 Hyderabad-98493-99240 Indore-98266-66091 Jaipur-98290-10813 Jamshedpur-98351-82109 Kolkata-98303-36101Lucknow-98399-12034 Ludhiana-98765-87088 Madural-98431-33990 Mumbai-98923-00706 Nagpur-99701-80877 New Delhi-98102-12502 Pune-98220-11086 Raipur-98266-66092 Surat-98256-07617 Trichy-99406-76502 Vadodara-0265-6548444 Vishakapatnam-98493-99238 Western UP & Uttarakhand-97600-05793 Agartala-94361-28939 Kolhapur-98906-26205 Kota-98290-14899 Mangalore-98457-31944 Tirupathi-98661-30930 Haldwani-99970-12643 Nashik-98900-12944 Navi Mumbai-98923-00701 Pondichery-98942-22033 Warangal-98495-51691 Kanpur-98392-34539 Salem-98433-19533 Silchar-94354-04033 Silliguri-98320-11433 Muzaffarnagar-98970-73741 Udaipur-98292-44085 Vijayawada-98662-20504 Bhilai-98266-12907 Renukoot-98399-55117 Bhopal-98266-66093 Baddi-93187-78975 Gwalior-98268-03658 Ambala-93541-18839 Ghaziabad-98107-44937 Gorakhpur-98392-24988 Jodhpur-98292-18618 Durgapur-97320-03364 Jabalpur-98268-03656 Jalandhar-98763-47188 Rajkot-98256-04709